999 resultados para Organs (Anatomy) Endoscopic surgery


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico(CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Postoperative endoscopic recurrence (PER) occurs in nearly 80% of patients 1 year after ileocecal resection in patients with Crohn's disease (CD). Biological agents were more effective in reducing the rates of PER in comparison with conventional therapy, in prospective trials. The aim of this study was to compare the PER rates of biological versus conventional therapy after ileocecal resections in patients with CD in real-world practice. The MULTIPER (Multicenter International Postoperative Endoscopic Recurrence) database is a retrospective analysis of PER rates in CD patients after ileocecal resection, from 7 referral centers in 3 different countries. All consecutive patients who underwent ileocecal resections between 2008 and 2012 and in whom colonoscopies had been performed up to 12 months after surgery, were included. Recurrence was defined as Rutgeerts' score ≥i2. The patients were allocated to either biological or conventional therapy after surgery, and PER rates were compared between the groups. Initially, 231 patients were evaluated, and 63 were excluded. Of the 168 patients in the database, 96 received anti-tumor necrosis factor agents and 72 were treated with conventional therapy after resection. The groups were comparable regarding age, gender, and perianal disease. There was longer disease duration, more previous resections, and more open surgical procedures in patients on biologicals postoperatively. PER was identified in 25/96 (26%) patients on biological therapy and in 24/72 (33.3%) patients on conventional therapy (P=0.310). In this retrospective observational analysis from an international database, no difference was observed between biological and conventional therapy in preventing PER after ileocecal resections in CD patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aims of the study were to measure endoscopically the retrolingual pharynx during wakefulness and sleep before and after maxillomandibular advancement surgery and to quantify the changes observed. Materials and Methods: Eighteen patients with mild to severe grade obstructive sleep apnea hypopnea were evaluated during wakefulness while sitting and lying down and during induced sleep in dorsal decubitus while breathing naturally. Images of the retrolingual region of the pharynx were captured with a nasofibroscope and recorded on a DVD using the Sony Vegas 8.0 software (Sony Creative Software, Madison, WI). The images captured in greater and smaller aperture were measured with the Image J software (produced by Wayne Rasband, United States National Institutes of Health, Bethesda, MD) in linear anteroposterior and linear laterolateral areas. A correction factor was then applied to equalize the size of the images and thus compare them to one another. Results: The postoperative dimensions of the pharynx always increased significantly in all measurements compared with the preoperative ones. During induced sleep in dorsal decubitus, there was a greater gain in the area of smaller aperture (201.33%). Conclusions: The proposed method showed that the dimensions of the pharynx always increased significantly after surgery for maxillomandibular advancement, although the gain was not homogeneous in all dimensions and also varied according to state of consciousness. The greatest gain was observed in the area of smaller aperture with the patient in induced sleep, thus reducing the collapse of the pharynx. (C) 2012 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives. Adductor spasmodic dysphonia (ADSD) is a focal laryngeal dystonia, which compromises greatly the quality of life of the patients involved. It is a severe vocal disorder characterized by spasms of laryngeal muscles during speech, producing phonatory breaks, forced, strained and strangled voice. Its symptoms result from involuntary and intermittent contractions of thyroarytenoid muscle during speech, which causes vocal fold to strain, pressing each vocal fold against the other and increasing glottic resistance. Botulinum toxin injection remains the gold-standard treatment. However, as injections should be repeated periodically leading to voice quality instability, a more definitive procedure would be desirable. In this pilot study we report the long-term vocal quality results of endoscopic laser thyroarytenoid myoneurectomy. Study Design. Prospective study. Methods. Surgery was performed in 15 patients (11 females and four males), aged between 29 and 73 years, diagnosed with ADSD. Voice Handicap Index (VHI) was obtained before and after surgery (median 31 months postoperatively). Results. A significant improvement in VHI was observed after surgery, as compared with baseline values (P = 0.001). The median and interquartile range for preoperative VHI was 99 and 13, respectively and 24 and 42, for postoperative VHI. Subjective improvement of voice as assessed by the patients showed median improvement of 80%. Conclusions. Because long-term follow-up showed significant improvement of voice quality, this innovative surgical technique seems a satisfactory alternative treatment of ADSD patients who seek a definite improvement of their condition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The fiber dissection technique provides unique 3-dimensional anatomic knowledge of the white matter. OBJECTIVE: To examine the optic radiation anatomy and its important relationship with the temporal stem and to discuss its findings in relation to the approaches to temporal lobe lesions. METHODS: We studied 40 cerebral hemispheres of 20 brains that had been fixed in formalin solution for 40 days. After removal of the arachnoid membrane, the hemispheres were frozen, and the Klingler technique was used for dissection under magnification. Stereoscopic 3-dimensional images of the dissection were obtained for illustration. RESULTS: The optic radiations are located deep within the superior and middle temporal gyri, always above the inferior temporal sulcus. The mean distance between the cortical surface and the lateral edge of the optic radiation was 21 mm. Its fibers are divided into 3 bundles after their origin. The mean distance between the anterior tip of the temporal horn and the Meyer loop was 4.5 mm, between the temporal pole and the anterior border of the Meyer loop was 28.4 mm, and between the limen insulae and the Meyer loop was 10.7 mm. The mean distance between the lateral geniculate body and the lateral margin of the central bundle of the optic radiation was 17.4 mm. CONCLUSION: The white matter fiber dissection reveals the tridimensional intrinsic architecture of the brain, and its knowledge regarding the temporal lobe is particularly important for the neurosurgeon, mostly because of the complexity of the optic radiation and related fibers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although the occurrence of glandular trichomes is frequently reported for aerial vegetative organs, many questions still remain opened about the presence of such trichomes in underground systems. Here, we present, for the first time, a comparative study concerning the structure, ultrastructure and chemical aspects of both, the aerial and underground glandular trichomes of two different Chrysolaena species, C obovata and C platensis. Glandular trichomes (GTs) were examined using LM, SEM, and TEM and also analyzed by GC-MS and HPLC coupled to UV/DAD and HR-ESI-MS (HPLC-UV-MS). In both aerial (leaf and bud) and underground (rhizophore) organs, the GTs are multicellular, biseriate and formed by five pairs of cells: a pair of support cells, a pair of basal cells, and three pairs of secreting cells. These secreting cells have, at the beginning of secretory process, abundance of smooth ER. The same classes of secondary metabolites are biosynthesized and stored in both aerial and underground GTs of C platensis and C obovata. These GTs from aerial and underground organs have similar cellular and sub-cellular anatomy, however the belowground trichomes show a higher diversity of compounds when compared to those from the leaves. We also demonstrate by means of HPLC-UV-DAD that the sesquiterpene lactones are located inside the trichomes and that hirsutinolides are not artifacts. (C) 2012 Elsevier GmbH. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Smilax L. in Brazil is represented by 32 taxa and it is a taxonomically difficult genus because the plants are dioecious and show wide phenotypic variation. The analysis and use of leaf anatomy characters is recognized as a frequently successful taxonomic method to distinguish between individual taxon, when floral material is absent or minute differences in flowers and foliage exist such as in Smilax. The aim of this study was to characterize the anatomical features of the aerial organs in Smilax syphilitica collected from the Atlantic Rainforest, in Santa Teresa-ES and the Smilax aff syphilitica from the Amazon Rainforest, in Manaus, Brazil. For this, a total of three samples of Smilax were collected per site. Sample leaves and stems were fixed with FAA 50, embedded in historesin, sectioned on a rotary microtome, stained and mounted in synthetic resin. Additionally, histochemical tests were performed and cuticle ornamentation was analyzed with standard scanning electron microscopy. S. syphilitica and S. aff syphilitica differed in cuticle ornamentation, epidermal cell arrangement and wall thickness, stomata type and orientation, calcium oxalate crystal type, and position of stem thorns. Leaf blades of S. syphilitica from the Amazon Rainforest have a network of rounded ridges on both sides, while in S. aff syphilitica, these ridges are parallel and the spaces between them are filled with numerous membranous platelets. Viewed from the front, the epidermal cells of S. syphilitica have sinuous walls (even more pronounced in samples from the Amazon); while in S. aff syphilitica, these cells are also sinuous but elongated in the cross-section of the blade and arranged in parallel. Stomata of S. syphilitica are paracytic, whereas in S. aff syphilitica, are both paracytic and anisocytic, and their polar axes are directed towards the mid-vein. Calcium oxalate crystals in S. syphilitica are prisms, whereas in S. aff syphilitica, crystal sand. Thorns occur in nodes and internodes in S. syphilitica but only in internodes in S. aff syphilitica. These features have proven to be of diagnostic value and may support a separation into two species, but future studies are needed to confirm that S. aff syphilitica is indeed a new taxon. Rev. Biol. Trop. 60(3): 1137-1148. Epub 2012 September 01.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: Current data do not provide enough information on how quality of life (QoL) evolves over time in cases of endoscopic thoracic sympathectomy (ETS). The purpose of this study was to ascertain whether the immediate improvement in QoL after the surgery was sustained until the fifth postoperative year. Methods: This was a prospective, nonrandomized and uncontrolled study. From March 2001 to December 2003, 475 consecutive patients with hyperhidrosis submitted to ETS were included. A QoL questionnaire was applied at the preoperative day, around the 30th postoperative day, and after the fifth year. Results: After excluding 22 patients who did not answer all the questions, we analyzed 453 patients. Their ages ranged from 11 to 57 years old, with a mean of 25.3 + 7.9 years, including 297 female patients (65.6%). All patients were assessed on three occasions: before surgery, around the 30th postoperative day, and after the fifth postoperative year. The QoL before surgery was considered to be poor or very poor for all patients. The QoL around 30 days after surgery was better in 412 patients (90.9%), the same in 27 patients (6.0%), and worse in 14 patients (3.1%). After 5 years, 409 patients (90.3%) were better, 27 (6.0%) were the same, and 14 (3.1%) were worse. There were no differences between these postoperative times according to the McNemar statistical test. Conclusion:The patients had an immediate improvement in QoL after ETS, and this improvement was sustained until the fifth postoperative year. (J Vase Surg 2012;55:154-6.)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective Severe pulmonary hypoplasia and pulmonary arterial hypertension are associated with reduced survival in congenital diaphragmatic hernia (CDH). We aimed to determine whether fetal endoscopic tracheal occlusion (FETO) improves survival in cases of severe isolated CDH. Methods Between May 2008 and July 2010, patients whose fetuses had severe isolated CDH (lung-to-head ratio < 1.0, liver herniation into the thoracic cavity and no other detectable anomalies) were assigned randomly to FETO or to no fetal intervention (controls). FETO was performed under maternal epidural anesthesia supplemented with fetal intramuscular anesthesia. Tracheal balloon placement was achieved with ultrasound guidance and fetoscopy between 26 and 30 weeks of gestation. All cases that underwent FETO were delivered by the EXIT procedure. Postnatal therapy was the same for both treated fetuses and controls. The primary outcome was survival to 6 months of age. Other maternal and neonatal outcomes were also evaluated. Results Twenty patients were enrolled randomly to FETO and 21 patients to standard postnatal management. The mean gestational age at randomization was similar in both groups (P = 0.83). Delivery occurred at 35.6 +/- 2.4 weeks in the FETO group and at 37.4 +/- 1.9 weeks in the controls (P < 0.01). In the intention-to-treat analysis, 10/20 (50.0%) infants in the FETO group survived, while 1/21 (4.8%) controls survived (relative risk (RR), 10.5 (95% CI, 1.5-74.7), P < 0.01). In the receivedtreatment analysis, 10/19 (52.6%) infants in the FETO group and 1/19 (5.3%) controls survived (RR, 10.0 (95% CI, 1.4-70.6) P < 0.01). Conclusion FETO improves neonatal survival in cases with isolated severe CDH. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To evaluate the sulcus anatomy and possible correlations between sulcus diameter and white-to-white (WTW) diameter in pseudophakic eyes, data that may be important in the stability of add-on intraocular lenses (IOLs). SETTING: University Eye Hospital, Tuebingen, Germany. DESIGN: Case series. METHODS: In pseudophakic eyes, the axial length (AL) and horizontal WTW were measured by the IOLMaster device. Cross-sectional images were obtained with a 50 MHz ultrasound biomicroscope on the 4 meridians: vertical, horizontal (180 degrees), temporal oblique, and nasal oblique. Sulcus-to-sulcus (STS), angle-to-angle (ATA), and sclera-to-sclera (ScTSc) diameters were measured. The IOL optic diameter (6.0 mm) served as a control. To test reliability, optic measurements were repeated 5 times in a subset of eyes. RESULTS: The vertical ATA and STS diameters were statistically significantly larger than the horizontal diameter (P=.0328 and P=.0216, respectively). There was no statistically significant difference in ScTSc diameters. A weak correlation was found between WTW and horizontal ATA (r = 0.5766, P<.0001) and between WTW and horizontal STS (r = 0.5040, P=.0002). No correlation was found between WTW and horizontal ScTSc (r = 0.2217, P=.1217). CONCLUSIONS: The sulcus anatomy had a vertical oval shape with the vertical meridian being the largest, but it also had variation in the direction of the largest meridian. The WTW measurements showed a weak correlation with STS. In pseudophakic eyes, Soemmerring ring or a bulky haptic may affect the ciliary sulcus anatomy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Background Metastases to the pancreas are rare, and usually mistaken for primary pancreatic cancers. This study aimed to describe the histology results of solid pancreatic tumours obtained by endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) for diagnosis of metastases to the pancreas. Methods In a retrospective review, patients with pancreatic solid tumours and history of previous extrapancreatic cancer underwent EUS-FNA from January/1997 to December/2010. Most patients were followed-up until death and some of them were still alive at the end of the study. The performance of EUS-FNA for diagnosis of pancreatic metastases was analyzed. Symptoms, time frame between primary tumour diagnosis and the finding of metastases, and survival after diagnosis were also analyzed. Results 37 patients underwent EUS-FNA for probable pancreas metastases. Most cases (65%) presented with symptoms, especially upper abdominal pain (46%). Median time between detection of the first tumour and the finding of pancreatic metastases was 36 months. Metastases were confirmed in 32 (1.6%) cases, 30 of them by EUS-FNA, and 2 by surgery. Other 5 cases were non-metastatic. Most metastases were from lymphoma, colon, lung, and kidney. Twelve (32%) patients were submitted to surgery. Median survival after diagnosis of pancreatic metastases was 9 months, with no difference of survival between surgical and non-surgical cases. Sensitivity, specificity, positive and negative predictive values, and accuracy of EUS-FNA with histology analysis of the specimens for diagnosis of pancreatic metastases were, respectively, 93.8%, 60%, 93.8%, 60% and 89%. Conclusion EUS-FNA with histology of the specimens is a sensitive and accurate method for definitive diagnosis of metastatic disease in patients with a previous history of extrapancreatic malignancies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Primary stability of stems in cementless total hip replacements is recognized to play a critical role for long-term survival and thus for the success of the overall surgical procedure. In Literature, several studies addressed this important issue. Different approaches have been explored aiming to evaluate the extent of stability achieved during surgery. Some of these are in-vitro protocols while other tools are coinceived for the post-operative assessment of prosthesis migration relative to the host bone. In vitro protocols reported in the literature are not exportable to the operating room. Anyway most of them show a good overall accuracy. The RSA, EBRA and the radiographic analysis are currently used to check the healing process of the implanted femur at different follow-ups, evaluating implant migration, occurance of bone resorption or osteolysis at the interface. These methods are important for follow up and clinical study but do not assist the surgeon during implantation. At the time I started my Ph.D Study in Bioengineering, only one study had been undertaken to measure stability intra-operatively. No follow-up was presented to describe further results obtained with that device. In this scenario, it was believed that an instrument that could measure intra-operatively the stability achieved by an implanted stem would consistently improve the rate of success. This instrument should be accurate and should give to the surgeon during implantation a quick answer concerning the stability of the implanted stem. With this aim, an intra-operative device was designed, developed and validated. The device is meant to help the surgeon to decide how much to press-fit the implant. It is essentially made of a torsional load cell, able to measure the extent of torque applied by the surgeon to test primary stability, an angular sensor that measure the relative angular displacement between stem and femur, a rigid connector that enable connecting the device to the stem, and all the electronics for signals conditioning. The device was successfully validated in-vitro, showing a good overall accuracy in discriminating stable from unstable implants. Repeatability tests showed that the device was reliable. A calibration procedure was then performed in order to convert the angular readout into a linear displacement measurement, which is an information clinically relevant and simple to read in real-time by the surgeon. The second study reported in my thesis, concerns the evaluation of the possibility to have predictive information regarding the primary stability of a cementless stem, by measuring the micromotion of the last rasp used by the surgeon to prepare the femoral canal. This information would be really useful to the surgeon, who could check prior to the implantation process if the planned stem size can achieve a sufficient degree of primary stability, under optimal press fitting conditions. An intra-operative tool was developed to this aim. It was derived from a previously validated device, which was adapted for the specific purpose. The device is able to measure the relative micromotion between the femur and the rasp, when a torsional load is applied. An in-vitro protocol was developed and validated on both composite and cadaveric specimens. High correlation was observed between one of the parameters extracted form the acquisitions made on the rasp and the stability of the corresponding stem, when optimally press-fitted by the surgeon. After tuning in-vitro the protocol as in a closed loop, verification was made on two hip patients, confirming the results obtained in-vitro and highlighting the independence of the rasp indicator from the bone quality, anatomy and preserving conditions of the tested specimens, and from the sharpening of the rasp blades. The third study is related to an approach that have been recently explored in the orthopaedic community, but that was already in use in other scientific fields. It is based on the vibration analysis technique. This method has been successfully used to investigate the mechanical properties of the bone and its application to evaluate the extent of fixation of dental implants has been explored, even if its validity in this field is still under discussion. Several studies have been published recently on the stability assessment of hip implants by vibration analysis. The aim of the reported study was to develop and validate a prototype device based on the vibration analysis technique to measure intra-operatively the extent of implant stability. The expected advantages of a vibration-based device are easier clinical use, smaller dimensions and minor overall cost with respect to other devices based on direct micromotion measurement. The prototype developed consists of a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on four composite femurs implanted with a conventional stem. The results showed that the input signal was repeatable and the output could be recorded accurately. The fourth study concerns the application of the device based on the vibration analysis technique to several cases, considering both composite and cadaveric specimens. Different degrees of bone quality were tested, as well as different femur anatomies and several levels of press-fitting were considered. The aim of the study was to verify if it is possible to discriminate between stable and quasi-stable implants, because this is the most challenging detection for the surgeon in the operation room. Moreover, it was possible to validate the measurement protocol by comparing the results of the acquisitions made with the vibration-based tool to two reference measurements made by means of a validated technique, and a validated device. The results highlighted that the most sensitive parameter to stability is the shift in resonance frequency of the stem-bone system, showing high correlation with residual micromotion on all the tested specimens. Thus, it seems possible to discriminate between many levels of stability, from the grossly loosened implant, through the quasi-stable implants, to the definitely stable one. Finally, an additional study was performed on a different type of hip prosthesis, which has recently gained great interest thus becoming fairly popular in some countries in the last few years: the hip resurfacing prosthesis. The study was motivated by the following rationale: although bone-prosthesis micromotion is known to influence the stability of total hip replacement, its effect on the outcome of resurfacing implants has not been investigated in-vitro yet, but only clinically. Thus the work was aimed at verifying if it was possible to apply to the resurfacing prosthesis one of the intraoperative devices just validated for the measurement of the micromotion in the resurfacing implants. To do that, a preliminary study was performed in order to evaluate the extent of migration and the typical elastic movement for an epiphyseal prosthesis. An in-vitro procedure was developed to measure micromotions of resurfacing implants. This included a set of in-vitro loading scenarios that covers the range of directions covered by hip resultant forces in the most typical motor-tasks. The applicability of the protocol was assessed on two different commercial designs and on different head sizes. The repeatability and reproducibility were excellent (comparable to the best previously published protocols for standard cemented hip stems). Results showed that the procedure is accurate enough to detect micromotions of the order of few microns. The protocol proposed was thus completely validated. The results of the study demonstrated that the application of an intra-operative device to the resurfacing implants is not necessary, as the typical micromovement associated to this type of prosthesis could be considered negligible and thus not critical for the stabilization process. Concluding, four intra-operative tools have been developed and fully validated during these three years of research activity. The use in the clinical setting was tested for one of the devices, which could be used right now by the surgeon to evaluate the degree of stability achieved through the press-fitting procedure. The tool adapted to be used on the rasp was a good predictor of the stability of the stem. Thus it could be useful for the surgeon while checking if the pre-operative planning was correct. The device based on the vibration technique showed great accuracy, small dimensions, and thus has a great potential to become an instrument appreciated by the surgeon. It still need a clinical evaluation, and must be industrialized as well. The in-vitro tool worked very well, and can be applied for assessing resurfacing implants pre-clinically.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We propose a computationally efficient and biomechanically relevant soft-tissue simulation method for cranio-maxillofacial (CMF) surgery. A template-based facial muscle reconstruction was introduced to minimize the efforts on preparing a patient-specific model. A transversely isotropic mass-tensor model (MTM) was adopted to realize the effect of directional property of facial muscles in reasonable computation time. Additionally, sliding contact around teeth and mucosa was considered for more realistic simulation. Retrospective validation study with postoperative scan of a real patient showed that there were considerable improvements in simulation accuracy by incorporating template-based facial muscle anatomy and sliding contact.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Unrecognized reduction of blood supply to intestinal organs is associated with significant postoperative morbidity in abdominal surgery. The aim of this study was to determine whether--in the absence of hypovolemia--intestinal hypoperfusion as a result of blood flow redistribution occurs after abdominal surgery.