949 resultados para Optimized cooling


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The magnet design, fabrication, and measurement of HIRFL-CSR (Heavy Ion Research Facility in Lanzhou Cooling Storage Ring) are presented. All magnets will be laminated And welded with an armor-coated surface between two big endplates made of sticking glue 0.5 mm-thick sheets. The dipole of CSRm was chosen an H type with an air circle on the pole to improve the field uniformity. The dipole of CSRe was chosen the C type with an air circle and two air slots on the pole to improve the field homogeneity. Its reproducibility of magnet to magnet was adjusted with inserting small laminating pieces before demountable pole ends to reach less than +/- 2 x 10(-4) at optimized field level. CSRm quadrupoles diameter is 170 mm and has two different lengths, and its endplates were made with punching pieces after coating with epoxy glue, there is chamfered directly on the pole ends to reduce 12th-order contribution of field and without the demountable pole ends. CSRe main quadrupoles diameter is 240 mm and has two different lengths, and its endplates were also made with punching pieces coated with epoxy glue, there is also chamfered directly on the pole ends to reduce 12th-order contribution of field like CSRm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Superconducting ECR ion source with Advanced design in Lanzhou (SECRAL) was successfully built to produce intense beams of highly charged ions for Heavy Ion Research Facility in Lanzhou (HIRFL). The ion source has been optimized to be operated at 28GHz for its maximum performance. The superconducting magnet confinement configuration of the ion source consists of three axial solenoid coils and six sextupole coils with a cold iron structure as field booster and clamping. For 28GHz operation, the magnet assembly can produce peak mirror fields on axis 3.6T at injection, 2.2T at extraction and a radial sextupole field of 2.0T at plasma chamber wall. A unique feature of SECRAL is that the three axial solenoid coils are located inside of the sextupole bore in order to reduce the interaction forces between the sextupole coils and the solenoid coils. During the ongoing commissioning phase at 18GHz with a stainless steel chamber, tests with various gases and some metals have been conducted with microwave power less than 3.2kW and it turned out the performance is very promising. Some record ion beam intensities have been produced, for instance, 810e mu A of O7+, 505e mu A of Xe20+, 306e mu A of Xe27+, 21e mu A of Xe34+, 2.4e mu A of Xe38+ and so on. To reach better results for highly charged ion beams, further modifications such as an aluminium chamber with better cooling, higher microwave power and a movable extraction system will be done, and also emittance measurements are being prepared.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on several facts of CSRrn, such as the layout of the ring, the lattice parameters, exiting Schottky noise diagnosis equipment and fund, the primary stochastic cooling design of CSRm has been carried out. The optimum cooling time and the optimum cooling bandwidth axe obtained through simulation using the cooling function. The results indicate that the stochastic cooling is quite a powerful cooling method for CSRm. The comparison of the cooling effects of stochastic cooling and electron cooling in CSR are also presented. We can conclude that the combination of the two cooling methods on CSRrn will improve the beam cooling rate and quality beam greatly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Application of electron-cooling upgrades the quality of ion beams in the storage rings and brings new problems. The transverse magnetic field distorts the ion orbit while guiding the intense electron beam. The closed-orbit distortion should be and can be localized and controlled well inside the ring acceptance. This paper deals with the field in the e-cool section and concomitant COD of ion orbit and shows the correction scheme.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

主环二极铁电源是兰州重离子加速器冷却储存环(HIRFL-CSR)工程的关键设备和指标要求最高的一台电源,采用了独特的拓扑和控制策略。为满足峰值功率3.15MW(3kA,1.45kV)的输出能力和快脉冲要求,采用了晶闸管整流并联脉宽调制补偿单元的主电路拓扑结构和特殊的控制方式,这套综合方案确保电源满足了全部技术指标。本文介绍了该拓扑结构的原理和优势,讨论了为满足±2×10-4的跟踪误差的要求而采用的控制拓扑和双基准给定的原理,并简介了调试过程和近年来的运行和改进情况。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

HIRFL-CSR工程对CSRe冷却装置电子冷却部分的控制系统在实时性和可靠性方面提出了非常高的要求。电子冷却工作环境复杂,各种干扰难以预测。从电子冷却的控制系统改进出发,以实现电子冷却的自动调束为目标,以高端FPGA和ARM嵌入式系统为基础,采用P2P通讯技术和神经元网络算法来实现对电子冷却的自动控制。该控制系统对电子冷却控制的完善提供了先进的硬件平台和软件实现方案。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

介绍了一种基于一线总线数字温度传感器的HIFRL-CSR循环冷却水温度远程测量系统,阐述了以DT400模块为核心的温度测量的硬件模块和软件设计。该系统具有测温精度高、易扩展性、低成本、低功耗、可靠性高、抗干扰能力强等特点,根据不同需要可应用于多种温度测量系统中。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

为测量重离子加速器冷却储存环(HIRFL-CSR)的外靶实验终端上不同能量的γ射线,一种用于探测γ射线的高能量分辨的探测装置正在中国科学院近代物理研究所建设,该探测器由中国科学院近代物理研究所自行生长的铊激活的碘化铯CsI(Tl)晶体组成。与日本Hamamatsu公司生产的S8664-1010型雪崩光二极管(APD)耦合,测试其光输出的非均匀性和能量分辨,从测试结果给出了所需CsI(Tl)晶体合格的标准。目前已完成该γ探测球计划的六分之一,所提供的晶体合格率达94%以上。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The 400 MeV/u C-12(6+) ion beam was successfully cooled by the intensive electron beam near 1 A in CSRe. The momentum cooling time was estimated near 15 s. The cooling force was measured in the cases of different electron beam profiles, and the different angles between the ion beam and electron beam. The lifetime of the ion beam in CSRe was over 80 h. The dispersion in the cooling section was confirmed as positive close to zero. The beam sizes before cooling and after cooling were measured by the moving screen. The beam diameter after cooling was about 1 mm. The bunch length was measured with the help of the signals from the beam position monitor. The diffusion was studied in the absence of the electron beam.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PCBM (a C-60 derivative) is so far the most successful electron acceptor for bulk-heterojunction polymer photovoltaic (PV) cells. Here we present a novel method epitaxy-assisted creation of PCBM nanocrystals and their homogeneous distribution in the matrix using freshly cleaved mica sheet as the substrate. The highly matched epitaxy relationship between the unit cell of PCBM crystal and crystallographic (001) surface of mica induces abundant PCBM nuclei, which subsequently develop into nanoscale crystals with homogeneous dispersion in the composite film.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ice crystal formation is assumed as the most lethal factor for the failure of fish embryo cryopreservation and intracellular ice formation (IIF) plays a central role in cell injury during cooling. The objectives were to observe the morphological changes of red seabream (Pagrus major) embryo during the cooling-thawing process, and to examine the effect of cryoprotectant and cooling rate on the temperatures of oil globule ice formation (T-OIF), extra-cellular ice formation (T-EIF) and intracellular ice formation (T-IIF) using cryomicroscope. After thawing, the morphological changes of embryos were observed and recorded by the video attachment and monitor under the microscope. During the cooling process, three representative phenomena were observed: oil globule gradually turned bright firstly, then the whole field of view flashed and the embryo blackened. Cooling rate affect the temperature of both extra- and intra-cellular ice formations. T-EIF and T-IIF at high cooling rate were much lower than that at low cooling rate. And the value of T-EIF - T-IIF increased from 0.45 to 11.11 degrees C with the increase of cooling rate from 3 to 130 degrees C/min. Taken together, our results suggested that high cooling rate with proper cryoprotectant would be a good option for red seabream embryo cryopreservation. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esta es la versión no revisada del artículo: Inmaculada Higueras, Natalie Happenhofer, Othmar Koch, and Friedrich Kupka. 2014. Optimized strong stability preserving IMEX Runge-Kutta methods. J. Comput. Appl. Math. 272 (December 2014), 116-140. Se puede consultar la versión final en https://doi.org/10.1016/j.cam.2014.05.011