933 resultados para Newborn-infants
Resumo:
Objective: To assess the effect of reduced skin exposure in preterm infants receiving overhead phototherapy treatment on total serum bilirubin (TSB). Methods: Randomized controlled trial. Preterm infants (>1500 g birthweight and less than or equal to 36 weeks gestation) were randomized to being nursed either partially clothed with only disposable nappies and in posturally supported positions (n = 30) or naked without postural support (n = 29). Primary outcome was mean TSB percentage change at 24 h of completed conventional overhead phototherapy treatment (irradiance of 6 muWcm(-2)/nm at a wavelength of 425-475 nm). The incidence of rebound jaundice, number of infants continuing to receive phototherapy treatment at 24 h periods, parental stress, mother-infant interaction and mean TSB percentage change at 24 h of completed conventional overhead phototherapy treatment were examined. Results: Mean TSB percentage change at 24 h of completed treatment for the partially clothed group was 15.4% (+/-18) and for the naked group 19% (+/-15) (mean difference 3.6% 95% CI -5.1, 12.3). No other outcomes were significantly affected by reduced skin exposure to overhead phototherapy treatment. Conclusion: Our results show no statistically significant difference in TSB level change using either nursing practice.
Resumo:
This work has, as its objective, the development of non-invasive and low-cost systems for monitoring and automatic diagnosing specific neonatal diseases by means of the analysis of suitable video signals. We focus on monitoring infants potentially at risk of diseases characterized by the presence or absence of rhythmic movements of one or more body parts. Seizures and respiratory diseases are specifically considered, but the approach is general. Seizures are defined as sudden neurological and behavioural alterations. They are age-dependent phenomena and the most common sign of central nervous system dysfunction. Neonatal seizures have onset within the 28th day of life in newborns at term and within the 44th week of conceptional age in preterm infants. Their main causes are hypoxic-ischaemic encephalopathy, intracranial haemorrhage, and sepsis. Studies indicate an incidence rate of neonatal seizures of 0.2% live births, 1.1% for preterm neonates, and 1.3% for infants weighing less than 2500 g at birth. Neonatal seizures can be classified into four main categories: clonic, tonic, myoclonic, and subtle. Seizures in newborns have to be promptly and accurately recognized in order to establish timely treatments that could avoid an increase of the underlying brain damage. Respiratory diseases related to the occurrence of apnoea episodes may be caused by cerebrovascular events. Among the wide range of causes of apnoea, besides seizures, a relevant one is Congenital Central Hypoventilation Syndrome (CCHS) \cite{Healy}. With a reported prevalence of 1 in 200,000 live births, CCHS, formerly known as Ondine's curse, is a rare life-threatening disorder characterized by a failure of the automatic control of breathing, caused by mutations in a gene classified as PHOX2B. CCHS manifests itself, in the neonatal period, with episodes of cyanosis or apnoea, especially during quiet sleep. The reported mortality rates range from 8% to 38% of newborn with genetically confirmed CCHS. Nowadays, CCHS is considered a disorder of autonomic regulation, with related risk of sudden infant death syndrome (SIDS). Currently, the standard method of diagnosis, for both diseases, is based on polysomnography, a set of sensors such as ElectroEncephaloGram (EEG) sensors, ElectroMyoGraphy (EMG) sensors, ElectroCardioGraphy (ECG) sensors, elastic belt sensors, pulse-oximeter and nasal flow-meters. This monitoring system is very expensive, time-consuming, moderately invasive and requires particularly skilled medical personnel, not always available in a Neonatal Intensive Care Unit (NICU). Therefore, automatic, real-time and non-invasive monitoring equipments able to reliably recognize these diseases would be of significant value in the NICU. A very appealing monitoring tool to automatically detect neonatal seizures or breathing disorders may be based on acquiring, through a network of sensors, e.g., a set of video cameras, the movements of the newborn's body (e.g., limbs, chest) and properly processing the relevant signals. An automatic multi-sensor system could be used to permanently monitor every patient in the NICU or specific patients at home. Furthermore, a wire-free technique may be more user-friendly and highly desirable when used with infants, in particular with newborns. This work has focused on a reliable method to estimate the periodicity in pathological movements based on the use of the Maximum Likelihood (ML) criterion. In particular, average differential luminance signals from multiple Red, Green and Blue (RGB) cameras or depth-sensor devices are extracted and the presence or absence of a significant periodicity is analysed in order to detect possible pathological conditions. The efficacy of this monitoring system has been measured on the basis of video recordings provided by the Department of Neurosciences of the University of Parma. Concerning clonic seizures, a kinematic analysis was performed to establish a relationship between neonatal seizures and human inborn pattern of quadrupedal locomotion. Moreover, we have decided to realize simulators able to replicate the symptomatic movements characteristic of the diseases under consideration. The reasons is, essentially, the opportunity to have, at any time, a 'subject' on which to test the continuously evolving detection algorithms. Finally, we have developed a smartphone App, called 'Smartphone based contactless epilepsy detector' (SmartCED), able to detect neonatal clonic seizures and warn the user about the occurrence in real-time.
Resumo:
BACKGROUND: A pretrial clinical improvement project for the BOOST-II UK trial of oxygen saturation targeting revealed an artefact affecting saturation profiles obtained from the Masimo Set Radical pulse oximeter.
METHODS: Saturation was recorded every 10 s for up to 2 weeks in 176 oxygen dependent preterm infants in 35 UK and Irish neonatal units between August 2006 and April 2009 using Masimo SET Radical pulse oximeters. Frequency distributions of % time at each saturation were plotted. An artefact affecting the saturation distribution was found to be attributable to the oximeter's internal calibration algorithm. Revised software was installed and saturation distributions obtained were compared with four other current oximeters in paired studies.
RESULTS: There was a reduction in saturation values of 87-90%. Values above 87% were elevated by up to 2%, giving a relative excess of higher values. The software revision eliminated this, improving the distribution of saturation values. In paired comparisons with four current commercially available oximeters, Masimo oximeters with the revised software returned similar saturation distributions.
CONCLUSIONS: A characteristic of the software algorithm reduces the frequency of saturations of 87-90% and increases the frequency of higher values returned by the Masimo SET Radical pulse oximeter. This effect, which remains within the recommended standards for accuracy, is removed by installing revised software (board firmware V4.8 or higher). Because this observation is likely to influence oxygen targeting, it should be considered in the analysis of the oxygen trial results to maximise their generalisability.
Resumo:
Background: Noninvasive transcutaneous carbon dioxide monitoring has been shown to be accurate in infants and children, limited data are available to show the usefulness and limitations of partial transcutaneous carbon dioxide tension (PtCO2) value. Objectives: The current study prospectively determines the effectiveness and accuracy of PtCO2 measurements in newborns. Materials and Methods: Venous blood gas sampling and monitoring of the PtCO2 level (TCM TOSCA, Radiometer) were done simultaneously. All measurements are performed on mechanically ventilated infants. Partial venous carbon dioxide tension (PvCO2) values divided into three groups according to hypocapnia (Group 1: < 4.68 kPa), normocapnia (Group 2: 4.68–7.33 kPa), hypercapnia (Group 3: > 7.33 kPa) and then PvCO2 and PtCO2 data within each group were compared separately. Results: A total of 168 measurements of each PvCO2 and PtCO2 data were compared in three separated groups simultaneously (13 in Group 1, 118 in Group 2, and 37 in Group 3). A bias of more than ± 0.7 kPa was considered unacceptable. PtCO2 was related to PvCO2 with acceptable results between the two measurements in hypocapnia (mean difference 0.20 ± 0.19 kPa) and normocapnia (0.002 ± 0.30 kPa) groups. On the other hand in hypercapnia group PtCO2 values were statistically significant (P < 0.001) and lower than PvCO2 data (mean difference 0.81 ± 1.19 kPa) Conclusions: PtCO2 measurements have generally good agreement with PvCO2 in hypocapnic and normocapnic intubated infants but there are some limitations especially with high level of CO2 tension. Monitoring of PtCO2 is generally a useful non-invasive indicator of PvCO2 in hypocapnic and normocapnic infants.
Resumo:
Background: The most common reason of respiratory distress in the newborn is transient tachypnea of the newborn (TTN). There are some reports saying that TTN is associated with increased frequencies of wheezing attacks. Objectives: The aims of this study were to determine the risk factors associated with TTN and to determine the association between TTN and the development of wheezing syndromes in early life. Materials and Methods: In a historical cohort study, we recorded the characteristics of 70 infants born at the Shohadaye Kargar Hospital in Yazd between March 2005 and March 2009 and who were hospitalized because of TTN in the neonatal intensive-care unit. We called their parents at least four years after the infants were discharged from the hospital and asked about any wheezing attacks. Seventy other infants with no health problems during the newborn period were included in the study as the control group. Results: The rate of wheezing attacks in newborns with TTN was more than patients with no TTN diagnosis (P = 0.014). TTN was found to be an independent risk factor for later wheezing attacks (relative risk [RR] = 2.8). Conclusions: The most obvious finding of this study was that TTN was an independent risk factor for wheezing attacks. So long-term medical care is suggested for these patients who may be at risk, because TTN may not be as transient as has been previously thought.
Resumo:
Background: D-Lactate is normally present in the blood of humans at nanomolar concentrations due to methylglyoxal metabolism; millimolar D-lactate concentrations can arise due to excess gastrointestinal microbial production. Objectives: To examine the levels of plasma D-lactate in the necrotizing enterocolitis in premature infants. Patients and Methods: 128 premature infants were divided into control (group I, n = 69), feeding intolerance (group II, n = 42) and NEC (group III, n = 27) groups. Plasma D-lactate levels were measured at the onset of feeding intolerance or NEC and at weeks 2-3 in control infants (group I) by ELISA. Data were analyzed using descriptive statistics, non-parametric tests and Student’s t-test. Results: In groups I, II, III, median birth weights were 1845.7 ± 267.5 g, 1913.1 ± 306.5 g, and 1898.4 ± 285.3 g, median gestational ages were 34.3 ± 1.7 weeks, 33.9 ± 2.2 weeks and 35.1 ± 2.6 weeks, ages of sampling were 12.3 ± 2.9 days, 14.6 ± 3.7 days and 15.1 ± 1.8 days, respectively. The differences of median birth weights, median gestational ages and ages of sampling were not statistically significant (P > 0.05). The plasma D-lactate levels in groups I, II, III were 3.6 ± 1.9 μg/mL, 12.7 ± 8.3 μg/mL, and 35.4 ± 29.1 μg/mL, respectively, group III had higher plasma D-lactate level than groups I, II, and the difference among these groups was significant (x2 = 21.6, P < 0.01). Conclusions: Plasma D-lactate significantly increased early in NEC. Plasma D-lactate levels were associated with extensive disease in NEC infants. Therefore, it could be used as a diagnosis indicator in the early stage of NEC.
Resumo:
To analyze the effects of treatment approach on the outcomes of newborns (birth weight [BW] < 1,000 g) with patent ductus arteriosus (PDA), from the Brazilian Neonatal Research Network (BNRN) on: death, bronchopulmonary dysplasia (BPD), severe intraventricular hemorrhage (IVH III/IV), retinopathy of prematurity requiring surgical (ROPsur), necrotizing enterocolitis requiring surgery (NECsur), and death/BPD. This was a multicentric, cohort study, retrospective data collection, including newborns (BW < 1000 g) with gestational age (GA) < 33 weeks and echocardiographic diagnosis of PDA, from 16 neonatal units of the BNRN from January 1, 2010 to Dec 31, 2011. Newborns who died or were transferred until the third day of life, and those with presence of congenital malformation or infection were excluded. Groups: G1 - conservative approach (without treatment), G2 - pharmacologic (indomethacin or ibuprofen), G3 - surgical ligation (independent of previous treatment). Factors analyzed: antenatal corticosteroid, cesarean section, BW, GA, 5 min. Apgar score < 4, male gender, Score for Neonatal Acute Physiology Perinatal Extension (SNAPPE II), respiratory distress syndrome (RDS), late sepsis (LS), mechanical ventilation (MV), surfactant (< 2 h of life), and time of MV. death, O2 dependence at 36 weeks (BPD36wks), IVH III/IV, ROPsur, NECsur, and death/BPD36wks. Student's t-test, chi-squared test, or Fisher's exact test; Odds ratio (95% CI); logistic binary regression and backward stepwise multiple regression. Software: MedCalc (Medical Calculator) software, version 12.1.4.0. p-values < 0.05 were considered statistically significant. 1,097 newborns were selected and 494 newborns were included: G1 - 187 (37.8%), G2 - 205 (41.5%), and G3 - 102 (20.6%). The highest mortality was observed in G1 (51.3%) and the lowest in G3 (14.7%). The highest frequencies of BPD36wks (70.6%) and ROPsur were observed in G3 (23.5%). The lowest occurrence of death/BPD36wks occurred in G2 (58.0%). Pharmacological (OR 0.29; 95% CI: 0.14-0.62) and conservative (OR 0.34; 95% CI: 0.14-0.79) treatments were protective for the outcome death/BPD36wks. The conservative approach of PDA was associated to high mortality, the surgical approach to the occurrence of BPD36wks and ROPsur, and the pharmacological treatment was protective for the outcome death/BPD36wks.
Resumo:
The purpose of this study was to compare the behavior of full-term small-for-gestational age (SGA) with full-term appropriate-for gestational age (AGA) infants in the first year of life. We prospectively evaluated 68 infants in the 2nd month, 67 in the 6th month and 69 in the 12th month. The Bayley Scales of Infant Development-II were used, with emphasis on the Behavior Rating Scale (BRS). The groups were similar concerning the item interest in test materials and stimuli; there was a trend toward differences in the items negative affect, hypersensitivity to test materials and adaptation to change in test materials. The mean of Raw Score was significantly lower for the SGA group in the items predominant state, liability of state of arousal, positive affect, soothability when upset, energy, exploration of objects and surroundings, orientation toward examiner. A lower BRS score was associated with the SGA group in the 2nd month.
Resumo:
To assess binocular detection grating acuity using the LEA GRATINGS test to establish age-related norms in healthy infants during their first 3 months of life. In this prospective, longitudinal study of healthy infants with clear red reflex at birth, responses to gratings were measured at 1, 2, and 3 months of age using LEA gratings at a distance of 28 cm. The results were recorded as detection grating acuity values, which were arranged in frequency tables and converted to a one-octave scale for statistical analysis. For the repeated measurements, analysis of variance (ANOVA) was used to compare the detection grating acuity results between ages. A total of 133 infants were included. The binocular responses to gratings showed development toward higher mean values and spatial frequencies, ranging from 0.55 ± 0.70 cycles per degree (cpd), or 1.74 ± 0.21 logMAR, in month 1 to 3.11 ± 0.54 cpd, or 0.98 ± 0.16 logMAR, in month 3. Repeated ANOVA indicated differences among grating acuity values in the three age groups. The LEA GRATINGS test allowed assessment of detection grating acuity and its development in a cohort of healthy infants during their first 3 months of life.
Resumo:
To verify the methods used by the clinical trials that assessed the effect of tactile/kinesthetic stimulation on weight gain in preterm infants and highlight the similarities and differences among such studies. This review collected studies from two databases, PEDro and PubMed, in July of 2014, in addition to bibliographies. Two researchers assessed the relevant titles independently, and then chose which studies to read in full and include in this review by consensus. Clinical trials that studied tactile stimulation or massage therapy whether or not associated with kinesthetic stimulation of preterm infants; that assessed weight gain after the intervention; that had a control group and were composed in English, Portuguese, or Spanish were included. A total of 520 titles were found and 108 were selected for manuscript reading. Repeated studies were excluded, resulting in 40 different studies. Of these, 31 met all the inclusion criteria. There were many differences in the application of tactile/kinesthetic stimulation techniques among studies, which hindered the accurate reproduction of the procedure. Also, many studies did not describe the adverse events that occurred during stimulation, the course of action taken when such events occurred, and their effect on the outcome. These studies made a relevant contribution towards indicating tactile/kinesthetic stimulation as a promising tool. Nevertheless, there was no standard for application among them. Future studies should raise the level of methodological rigor and describe the adverse events. This may permit other researchers to be more aware of expected outcomes, and a standard technique could be established.
Resumo:
We studied the clinical aspects of 100 consecutive premature newborns with and without intraventricular and periventricular hemorrhage (IPVH).The diagnosis of IPVH was obtained by ultrasonic scans of the skull during the first week of life and at the age of one month. Forty eight percent of newborns with IPVH had abnormal results, and there was a significant correlation with the neurological evaluation in 85% of the infants. The probability of normality for a child with no associated brain abnormalities was 72%, whereas for a child of the same gestational age with associated brain abnormalities was 48.7%.
Resumo:
OBJECTIVE: To characterize the behavior of premature newborns in the first year of chronological age. METHODS: This is a cross-sectional descriptive study, bound to a longitudinal study titled: Comparison of visual behavior on the first quarter of year of life of premature nursling born at two maternities of Recife/PE. The sample was composed by 52 premature newborns selected from June, 2007 to June, 2008 from the Maternity of the Federal University of Pernambuco (UFPE). Biological, socioeconomic and demographic data was collected through medical records and interviews with progeny. Newborns were evaluated by the Assessment Guide of Visual Ability in Infants. RESULTS: Most of the newborns were male at a gestational period between 33 weeks and 36 weeks and 6 days, showed a good visual behavior development for the age researched, and most of the families showed good socioeconomical and demographic profile. Besides, it was possible to detect ocular signs in 19% of sample, that were referred to an Ophthalmology Service. CONCLUSION: This study results point out the method like an important key in the early detection and visual screening for premature nursling since the first month of life and it led us to believe that clinical view for occupational therapy intervention must be focused not only on biological risks but also at the influence environment in newborn performance.
Resumo:
A recomendação da Organização Mundial da Saúde é que todo recém nascido deva ser alimentado exclusivamente no seio materno até o sexto mês e, de forma complementar, até o segundo ano de vida. Assim, algumas técnicas são realizadas para facilitar a alimentação ao seio, dentre elas o uso do copo e, recentemente, a utilização da técnica "sonda-dedo". Tal prática é bastante controversa e há escassez de estudos na literatura sobre a descrição da técnica, sua indicação e uso. O objetivo do presente trabalho é relatar a experiência clínica para indicação e uso da técnica "sonda-dedo". A técnica "sonda-dedo" consiste no oferecimento do leite, de preferência humano, utilizando sonda gástrica conectada a uma seringa com êmbolo e fixada em dedo mínimo enluvado com fita adesiva. A sonda é posicionada na cavidade oral do recém nascido e deve servir como uma técnica de auxílio para adequação do padrão de sucção. Desta forma, sugere-se que sua indicação deve ser apenas nos casos em que seja caracterizada uma disfunção oral, seja em recém nascidos a termo ou pré-termo. Diante da avaliação específica, realizada pelo fonoaudiólogo, indica-se a técnica "sonda-dedo" com objetivo de adequar as alterações obtidas na avaliação da sucção não nutritiva ou em seio materno. Acredita-se que, para que a técnica "sonda-dedo" seja indicada como complemento do aleitamento materno, devam ser realizados novos estudos para esclarecer quais as repercussões da técnica "sonda-dedo" na prevalência do aleitamento materno e no desenvolvimento motor oral de recém nascidos.
Resumo:
Estudos populacionais sobre mortalidade neonatal de nascimentos de muito baixo peso ao nascer contribuem para identificar sua complexa rede de fatores de risco. Foi estudada uma coorte de 213 recém-nascidos com peso inferior a 1.500g (112 óbitos neonatais e 101 sobreviventes) na Região Sul do Município de São Paulo, Brasil, em 2000/2001. Foram realizadas entrevistas domiciliares e obtidos dados de prontuários hospitalares. Foi realizada análise de sobrevida e empregada regressão múltipla de Cox. A elevada mortalidade na sala de parto, no primeiro dia de vida e ausência de sobreviventes < 700g dos nascimentos < 1.000g e com menos de 28 semanas sugere que condutas mais ativas destinam-se a nascituros de maior viabilidade. Mães residentes em favela, com história anterior de cesárea e aborto provocado, adolescentes, com sangramento vaginal e ausência de pré-natal aumentaram o risco de óbito neonatal. Partos cesarianos e internação em berçários mostraram efeito protetor. O peso ao nascer abaixo de 1.000g e Apgar menor que 7 foram risco. A elevada mortalidade está associada às condições de vida, características maternas e dos nascimentos e condições assistenciais. A melhoria da atenção pré-natal e ao recém-nascido pode atuar na redução da mortalidade.
Resumo:
O objetivo foi descrever as características do recém-nascido, da mãe e da mortalidade neonatal precoce, segundo local de parto, na Região Metropolitana de São Paulo, Brasil. Utilizou-se coorte de nascidos vivos vinculados aos respectivos óbitos neonatais precoces, por técnica determinística. Identificou-se o parto domiciliar a partir da Declaração de Nascido Vivo e os ocorridos em estabelecimentos a partir da vinculação com o Cadastro Nacional de Estabelecimentos de Saúde. Foram estudados 154.676 nascidos vivos, dos quais 0,3% dos nascimentos ocorreram acidentalmente em domicílio, 98,7% em hospitais e menos de 1% em outro serviço de saúde. A mortalidade foi menor no Centro de Parto Normal e nas Unidades Mistas de Saúde, condizente com o perfil de baixo risco obstétrico. As taxas mais elevadas ocorreram nos prontos-socorros (54,4 óbitos por mil nascidos vivos) e domicílios (26,7), representando um risco de morte, respectivamente, 9,6 e 4,7 vezes maior que nos hospitais (5,6). Apesar da alta predominância do parto hospitalar, há um segmento de partos acidentais tanto em domicílios como em prontos-socorros que merece atenção, por registrar elevadas taxas de mortalidade neonatal precoce.