920 resultados para Monitoring of Structures


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper deals with the problem of stabilizing a class of structures subject to an uncertain excitation due to the temporary coupling of the main system with another uncertain dynamical subsystem. A Lyapunov function based control scheme is proposed to attenuate the structural vibration. In the control design, the actuator dynamics is taken into account. The control scheme is implemented by using only feedback information of the main system. The effectiveness of the control scheme is shown for a bridge platform with crossing vehicle

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The chemical contamination of natural waters is a global problem with a worldwide impact. Considering the relevance of this problem, this thesis is intended, on one hand, to develop different separation/preconcentration techniques based on membranes ability to permeate anions for the transport of toxic oxyanions of chromium(VI) and arsenic contained in aqueous matrices. In particular, we have investigated supported liquid membranes and polymer inclusion membranes, both of which contain the commercial quaternary ammonium salt Aliquat 336 as a carrier, as well as commercial anion exchange membranes. On the other hand, we have focused on the development of chemical sensors to facilitate the monitoring of several metals from different aqueous matrices. Thus, a selective optical sensor for Cr(VI) based on polymeric membranes containing Aliquat 336 as an ionophore has been designed. Additionally, mercury-based screen-printed electrodes have been evaluated for for cadmium, lead, copper and zinc detection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper discusses speech intelligibilty of hearing impaired children.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The reduction of indigo (dispersed in water) to leuco-indigo (dissolved in water) is an important industrial process and investigated here for the case of glucose as an environmentally benign reducing agent. In order to quantitatively follow the formation of leuco-indigo two approaches based on (i) rotating disk voltammetry and (ii) sonovoltammetry are developed. Leuco-indigo, once formed in alkaline solution, is readily monitored at a glassy carbon electrode in the mass transport limit employing hydrodynamic voltammetry. The presence of power ultrasound further improves the leuco-indigo determination due to additional agitation and homogenization effects. While inactive at room temperature, glucose readily reduces indigo in alkaline media at 65 degrees C. In the presence of excess glucose, a surface dissolution kinetics limited process is proposed following the rate law d eta(leuco-indigo)/dt = k x c(OH-) x S-indigo where eta(leuco-indigo) is the amount of leuco-indigo formed, k = 4.1 x 10(-9) m s(-1) (at 65 degrees C, assuming spherical particles of I gm diameter) is the heterogeneous dissolution rate constant,c(OH-) is the concentration of hydroxide, and Sindigo is the reactive surface area. The activation energy for this process in aqueous 0.2 M NaOH is E-A = 64 U mol(-1) consistent with a considerable temperature effects. The redox mediator 1,8-dihydroxyanthraquinone is shown to significantly enhance the reaction rate by catalysing the electron transfer between glucose and solid indigo particles. (c) 2006 Elsevier Ltd. All fights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To clarify the role of growth monitoring in primary school children, including obesity, and to examine issues that might impact on the effectiveness and cost-effectiveness of such programmes. Data sources: Electronic databases were searched up to July 2005. Experts in the field were also consulted. Review methods: Data extraction and quality assessment were performed on studies meeting the review's inclusion criteria. The performance of growth monitoring to detect disorders of stature and obesity was evaluated against National Screening Committee (NSC) criteria. Results: In the 31 studies that were included in the review, there were no controlled trials of the impact of growth monitoring and no studies of the diagnostic accuracy of different methods for growth monitoring. Analysis of the studies that presented a 'diagnostic yield' of growth monitoring suggested that one-off screening might identify between 1: 545 and 1: 1793 new cases of potentially treatable conditions. Economic modelling suggested that growth monitoring is associated with health improvements [ incremental cost per quality-adjusted life-year (QALY) of pound 9500] and indicated that monitoring was cost-effective 100% of the time over the given probability distributions for a willingness to pay threshold of pound 30,000 per QALY. Studies of obesity focused on the performance of body mass index against measures of body fat. A number of issues relating to human resources required for growth monitoring were identified, but data on attitudes to growth monitoring were extremely sparse. Preliminary findings from economic modelling suggested that primary prevention may be the most cost-effective approach to obesity management, but the model incorporated a great deal of uncertainty. Conclusions: This review has indicated the potential utility and cost-effectiveness of growth monitoring in terms of increased detection of stature-related disorders. It has also pointed strongly to the need for further research. Growth monitoring does not currently meet all NSC criteria. However, it is questionable whether some of these criteria can be meaningfully applied to growth monitoring given that short stature is not a disease in itself, but is used as a marker for a range of pathologies and as an indicator of general health status. Identification of effective interventions for the treatment of obesity is likely to be considered a prerequisite to any move from monitoring to a screening programme designed to identify individual overweight and obese children. Similarly, further long-term studies of the predictors of obesity-related co-morbidities in adulthood are warranted. A cluster randomised trial comparing growth monitoring strategies with no growth monitoring in the general population would most reliably determine the clinical effectiveness of growth monitoring. Studies of diagnostic accuracy, alongside evidence of effective treatment strategies, could provide an alternative approach. In this context, careful consideration would need to be given to target conditions and intervention thresholds. Diagnostic accuracy studies would require long-term follow-up of both short and normal children to determine sensitivity and specificity of growth monitoring.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Myoglobin has been studied in considerable detail using different experimental and computational techniques over the past decades. Recent developments in time-resolved spectroscopy have provided experimental data amenable to detailed atomistic simulations. The main theme of the present review are results on the structures, energetics and dynamics of ligands ( CO, NO) interacting with myoglobin from computer simulations. Modern computational methods including free energy simulations, mixed quantum mechanics/molecular mechanics simulations, and reactive molecular dynamics simulations provide insight into the dynamics of ligand dynamics in confined spaces complementary to experiment. Application of these methods to calculate and understand experimental observations for myoglobin interacting with CO and NO are presented and discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

1. Closed Ecological Systems (CES) are small manmade ecosystems which do not have any material exchange with the surrounding environment. Recent ecological and technological advances enable successful establishment and maintenance of CES, making them a suitable tool for detecting and measuring subtle feedbacks and mechanisms. 2. As a part of an analogue (physical) C cycle modelling experiment, we developed a non-intrusive methodology to control the internal environment and to monitor atmospheric CO2 concentration inside 16 replicated CES. Whilst maintaining an air-tight seal of all CES, this approach allowed for access to the CO2 measuring equipment for periodic re-calibration and repairs. 3. To ensure reliable cross-comparison of CO2 observations between individual CES units and to minimise the cost of the system, only one CO2 sampling unit was used. An ADC BioScientific OP-2 (open-path) analyser mounted on a swinging arm was passing over a set of 16 measuring cells. Each cell was connected to an individual CES with air continuously circulating between them. 4. Using this setup, we were able to continuously measure several environmental variables and CO2 concentration within each closed system, allowing us to study minute effects of changing temperature on C fluxes within each CES. The CES and the measuring cells showed minimal air leakage during an experimental run lasting, on average, 3 months. The CO2 analyser assembly performed reliably for over 2 years, however an early iteration of the present design proved to be sensitive to positioning errors. 5. We indicate how the methodology can be further improved and suggest possible avenues where future CES based research could be applied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Drake Passage is the narrowest constriction of the Antarctic Circumpolar Current (ACC) in the Southern Ocean, with implications for global ocean circulation and climate. We review the long-term sustained monitoring programmes that have been conducted at Drake Passage, dating back to the early part of the twentieth century. Attention is drawn to numerous breakthroughs that have been made from these programmes, including (a) the first determinations of the complex ACC structure and early quantifications of its transport; (b) realization that the ACC transport is remarkably steady over interannual and longer periods, and a growing understanding of the processes responsible for this; (c) recognition of the role of coupled climate modes in dictating the horizontal transport, and the role of anthropogenic processes in this; (d) understanding of mechanisms driving changes in both the upper and lower limbs of the Southern Ocean overturning circulation, and their impacts. It is argued that monitoring of this passage remains a high priority for oceanographic and climate research, but that strategic improvements could be made concerning how this is conducted. In particular, long-term programmes should concentrate on delivering quantifications of key variables of direct relevance to large-scale environmental issues: in this context, the time-varying overturning circulation is, if anything, even more compelling a target than the ACC flow. Further, there is a need for better international resource-sharing, and improved spatio-temporal coordination of the measurements. If achieved, the improvements in understanding of important climatic issues deriving from Drake Passage monitoring can be sustained into the future.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Optical characteristics of stirred curd were simultaneously monitored during syneresis in a 10-L cheese vat using computer vision and colorimetric measurements. Curd syneresis kinetic conditions were varied using 2 levels of milk pH (6.0 and 6.5) and 2 agitation speeds (12.1 and 27.2 rpm). Measured optical parameters were compared with gravimetric measurements of syneresis, taken simultaneously. The results showed that computer vision and colorimeter measurements have potential for monitoring syneresis. The 2 different phases, curd and whey, were distinguished by means of color differences. As syneresis progressed, the backscattered light became increasingly yellow in hue for circa 20 min for the higher stirring speed and circa 30 min for the lower stirring speed. Syneresis-related gravimetric measurements of importance to cheese making (e.g., curd moisture content, total solids in whey, and yield of whey) correlated significantly with computer vision and colorimetric measurements..

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The cheese industry has continually sought a robust method to monitor milk coagulation. Measurement of whey separation is also critical to control cheese moisture content, which affects quality. The objective of this study was to demonstrate that an online optical sensor detecting light backscatter in a vat could be applied to monitor both coagulation and syneresis during cheesemaking. A prototype sensor having a large field of view (LFV) relative to curd particle size was constructed. Temperature, cutting time, and calcium chloride addition were varied to evaluate the response of the sensor over a wide range of coagulation and syneresis rates. The LFV sensor response was related to casein micelle aggregation and curd firming during coagulation and to changes in curd moisture and whey fat contents during syneresis. The LFV sensor has potential as an online, continuous sensor technology for monitoring both coagulation and syneresis during cheesemaking.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to investigate a novel light backscatter sensor, with a large field of view relative to curd size, for continuous on-line monitoring of coagulation and syneresis to improve curd moisture content control. A three-level, central composite design was employed to study the effects of temperature, cutting time, and CaCl2 addition on cheese making parameters. The sensor signal was recorded and analyzed. The light backscatter ratio followed a sigmoid increase during coagulation and decreased asymptotically after gel cutting. Curd yield and curd moisture content were predicted from the time to the maximum slope of the first derivative of the light backscatter ratio during coagulation and the decrease in the sensor response during syneresis. Whey fat was affected by coagulation kinetics and cutting time, suggesting curd rheological properties at cutting are dominant factors determining fat losses. The proposed technology shows potential for on-line monitoring of coagulation and syneresis. 2007 Elsevier Ltd. All rights reserved..