960 resultados para Manifest refractive cylinder
Resumo:
This study aimed to determine the accuracy (and usability) of the Retinomax, a hand-held autorefractor, compared to measurements taken from hand-held retinoscopy (HHR) in a sample of normal 1-year-old children. The study was a method comparison set at four Community Child Health Clinics. Infants (n = 2079) of approximately 1 year of age were identified from birth/immunization records and their caregivers were contacted by mail. A total of 327 infants ranging in age from 46 weeks to 81 weeks (mean 61 weeks) participated in the study. The children underwent a full ophthalmic examination. Under cycloplegia, refraction was measured in each eye by streak retinoscopy (HHR) and then re-measured using the Retinomax autorefractor. Sphere, cylinder, axis of cylinder and spherical equivalent measurements were recorded for HHR and Retinomax instruments, and compared. Across the range of refractive errors measured, there was generally close agreement between the two examination methods, although the Retinomax consistently read around 0.3 D less hyperopic than HHR. Significantly more girls (72 infants, 47.7%), struggled during examination with the Retinomax than boys (52 infants, 29.5%) (P < 0.001). Agreement deteriorated between the two instruments if the patient struggled during the examination (P < 0.001). In general, the Retinomax would appear to be a useful screening instrument in early childhood. However, patient cooperation affects the accuracy of results and is an important con-sideration in determining whether this screening instrument should be adopted for measuring refractive errors in early infancy.
Resumo:
The cathodic and anodic characteristics of freshly polished and pre-reduced UNS S32550 (ASTM A479) super duplex stainless steel in a filtered and conductivity-adjusted seawater have been investigated under controlled flow conditions. A rotating cylinder electrode was used together with both steady and non-steady-state voltammetry and a potential step current transient technique to investigate the electrode reactions in the fully characterized electrolyte. Both oxygen reduction and hydrogen evolution were highly irreversible and the material exhibited excellent passivation and repassivation kinetics. Relative corrosion rates were derived and the corrosion mechanism of the alloy was found to be completely independent of the mass-transfer effects, which can contribute to flow-induced corrosion.
Resumo:
A recently developed whole of surface electroplating technique was used to obtain mass-transfer rates in the separated flow region of a stepped rotating cylinder electrode. These data are compared with previously reported mass-transfer rates obtained with a patch electrode. It was found that the two methods yield different results, where at lower Reynolds numbers, the mass-transfer rate enhancement was noticeably higher for the whole of the surface electrode than for the patch electrode. The location of the peak mass transfer behind the step, as measured with a patch electrode, was reported to be independent of the Reynolds number in previous studies, whereas the whole of the surface electrode shows a definite Reynolds number dependence. Large eddy simulation results for the recirculating region behind a step are used in this work to show that this difference in behavior is related to the existence of a much thinner fluid layer at the wall for which the velocity is a linear junction of distance from the wall. Consequently, the diffusion layer no longer lies well within a laminar sublayer. It is concluded that the patch electrode responds to the wall shear stress for smooth wall flow as well as for the disturbed flow region behind the step. When the whole of the surface is electro-active, the response is to mass transfer even when this is not a sole function of wall shear stress. The results demonstrate that the choice of the mass-transfer measurement technique in corrosion studies can have a significant effect on the results obtained from empirical data.
Resumo:
Turbulent flow around a rotating circular cylinder has numerous applications including wall shear stress and mass-transfer measurement related to the corrosion studies. It is also of interest in the context of flow over convex surfaces where standard turbulence models perform poorly. The main purpose of this paper is to elucidate the basic turbulence mechanism around a rotating cylinder at low Reynolds numbers to provide a better understanding of flow fundamentals. Direct numerical simulation (DNS) has been performed in a reference frame rotating at constant angular velocity with the cylinder. The governing equations are discretized by using a finite-volume method. As for fully developed channel, pipe, and boundary layer flows, a laminar sublayer, buffer layer, and logarithmic outer region were observed. The level of mean velocity is lower in the buffer and outer regions but the logarithmic region still has a slope equal to the inverse of the von Karman constant. Instantaneous flow visualization revealed that the turbulence length scale typically decreases as the Reynolds number increases. Wavelet analysis provided some insight into the dependence of structural characteristics on wave number. The budget of the turbulent kinetic energy was computed and found to be similar to that in plane channel flow as well as in pipe and zero pressure gradient boundary layer flows. Coriolis effects show as an equivalent production for the azimuthal and radial velocity fluctuations leading to their ratio being lowered relative to similar nonrotating boundary layer flows.
Resumo:
The optical forces in optical tweezers can be robustly modeled over a broad range of parameters using generalsed Lorenz–Mie theory. We describe the procedure, and show how the combination of experimental measurement of properties of the trap coupled with computational modeling, can allow unknown parameters of the particle—in this case, the refractive index—to be determined.
Resumo:
PURPOSE: To examine the effect of uncorrected astigmatism in older adults. SETTING: University Vision Clinic METHOD: Twenty-one healthy presbyopes, aged 58.9±2.8 years, had astigmatism of 0.0 to -4.0 x 90?DC and -3.0DC of cylinder at 90?, 180? and 45? induced with spectacle lenses, with the mean spherical equivalent compensated to plano, in random order. Visual acuity was assessed binocularly using a computerised test chart at 95%, 50% and 10% contrast. Near acuity and reading speed were measured using standardised reading texts. Light scatter was quantified with the cQuant and driving reaction times with a computer simulator. Finally visual clarity of a mobile phone and computer screen was subjectively rated. RESULTS: Distance visual acuity decreased with increasing uncorrected astigmatic power (F=174.50, p<0.001) and was reduced at lower contrasts (F=170.77, p<0.001). Near visual acuity and reading speed also decreased with increasing uncorrected astigmatism power (p<0.001). Light scatter was not significantly affected by uncorrected astigmatism (p>0.05), but the reliability and variability of measurements decreased with increasing uncorrected astigmatic power (p<0.05). Driving simulator performance was also unaffected by uncorrected astigmatism (p>0.05), but subjective rating of clarity decreased with increasing uncorrected astigmatic power (p<0.001). Uncorrected astigmatism at 45? or 180? orientation resulted in a worse distance and near visual acuity, and subjective rated clarity than 90? orientation (p<0.05). CONCLUSION: Uncorrected astigmatism, even as low as 1.0DC, causes a significant burden on a patient’s vision. If left uncorrected, this could impact significantly on their independence, quality of life and wellbeing.
Resumo:
The distinct behaviour of femtosecond laser inscribed long period gratings, with a non-uniform index perturbation within the optical fibre core, has been studied experimentally. The non-uniform laser-induced perturbation results in light coupling from the core mode to a greater number of cladding modes than is the case with their UV laser inscribed counterparts, and this is made evident from the surrounding refractive index (SRI) grating response. Femtosecond inscribed long period gratings are shown to simultaneously couple to multiple sets of cladding modes. A 400μm LPG is shown to result in attenuation peaks that have both blue and red wavelength shifts over a 1250nm to 1700nm wavelength range. This gives rise to SRI sensitivities far greater than anything achievable by monitoring a single attenuation peak. The maximum sensitivity produced by monitoring a single attenuation peak was 1106nm/RIU, whereas monitoring opposing wavelength shifts resulted in a significantly improved sensitivity of 1680nm/RIU. © 2011 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).
Resumo:
Background There is a paucity of data describing the prevalence of childhood refractive error in the United Kingdom. The Northern Ireland Childhood Errors of Refraction study, along with its sister study the Aston Eye Study, are the first population-based surveys of children using both random cluster sampling and cycloplegic autorefraction to quantify levels of refractive error in the United Kingdom. Methods Children aged 6–7 years and 12–13 years were recruited from a stratified random sample of primary and post-primary schools, representative of the population of Northern Ireland as a whole. Measurements included assessment of visual acuity, oculomotor balance, ocular biometry and cycloplegic binocular open-field autorefraction. Questionnaires were used to identify putative risk factors for refractive error. Results 399 (57%) of 6–7 years and 669 (60%) of 12–13 years participated. School participation rates did not vary statistically significantly with the size of the school, whether the school is urban or rural, or whether it is in a deprived/non-deprived area. The gender balance, ethnicity and type of schooling of participants are reflective of the Northern Ireland population. Conclusions The study design, sample size and methodology will ensure accurate measures of the prevalence of refractive errors in the target population and will facilitate comparisons with other population-based refractive data.
Resumo:
To describe the prevalence of refractive error (myopia and hyperopia) and visual impairment in a representative sample of white school children.
Resumo:
Long-period fibre gratings (LPGs) have previously been used to detect quantities such as temperature, strain and refractive index (RI). The responsivity to surrounding refractive index means that, potentially, LPGs could be realised as optical biosensors for applications in biochemical and biomedical application areas. We report here to our best knowledge the first investigation on refractive index sensing properties of LPGs with sol-gel derived titanium and silicon oxide coatings. It is revealed that the RI sensitivity of an LPG is affected by both the thickness and the index value of the coating; the coating with higher index and thickness will enhance the LPG RI sensitivity significantly. The surrounding refractive index induced LPG resonance shift has been evaluated over the LPGs’ most sensitive RI region from 1.42 to 1.44. We have identified that, in this region, the uncoated LPG has an RI sensitivity of (-673.0±0.4)nm/uri (unit of refractive index) while the LPG coated with titanium oxide exhibits a sensitivity as high as (-1067.15±0.04)nm/uri.
Resumo:
To study the visual and refractive outcomes after laser-assisted subepithelial keratectomy (LASEK) performed with a 213 nm solid-state laser for a broad range of refractive errors.