958 resultados para MAGNETIZATION STEPS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multi-parametric and quantitative magnetic resonance imaging (MRI) techniques have come into the focus of interest, both as a research and diagnostic modality for the evaluation of patients suffering from mild cognitive decline and overt dementia. In this study we address the question, if disease related quantitative magnetization transfer effects (qMT) within the intra- and extracellular matrices of the hippocampus may aid in the differentiation between clinically diagnosed patients with Alzheimer disease (AD), patients with mild cognitive impairment (MCI) and healthy controls. We evaluated 22 patients with AD (n=12) and MCI (n=10) and 22 healthy elderly (n=12) and younger (n=10) controls with multi-parametric MRI. Neuropsychological testing was performed in patients and elderly controls (n=34). In order to quantify the qMT effects, the absorption spectrum was sampled at relevant off-resonance frequencies. The qMT-parameters were calculated according to a two-pool spin-bath model including the T1- and T2 relaxation parameters of the free pool, determined in separate experiments. Histograms (fixed bin-size) of the normalized qMT-parameter values (z-scores) within the anterior and posterior hippocampus (hippocampal head and body) were subjected to a fuzzy-c-means classification algorithm with downstreamed PCA projection. The within-cluster sums of point-to-centroid distances were used to examine the effects of qMT- and diffusion anisotropy parameters on the discrimination of healthy volunteers, patients with Alzheimer and MCIs. The qMT-parameters T2(r) (T2 of the restricted pool) and F (fractional pool size) differentiated between the three groups (control, MCI and AD) in the anterior hippocampus. In our cohort, the MT ratio, as proposed in previous reports, did not differentiate between MCI and AD or healthy controls and MCI, but between healthy controls and AD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hippocampal formation (HF) of healthy control subjects and schizophrenic patients was examined using an MRI experiment that implements sequences for relaxometry and magnetization transfer (MT) quantification. In addition to the semi-quantitative magnetization transfer ratio (MTR), all of the observable properties of the binary spin bath model were included. The study demonstrates that, in contrast to the MTR, quantitative MT parameters (especially the T2 relaxation time of restricted protons, T2b) are capable to differentiate functionally significant subregions within the HF. The MT methodology appears to be a promising new tool for the differential microstructural evaluation of the HF in neuropsychiatric disorders accompanied by memory disturbances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative data obtained by means of design-based stereology can add valuable information to studies performed on a diversity of organs, in particular when correlated to functional/physiological and biochemical data. Design-based stereology is based on a sound statistical background and can be used to generate accurate data which are in line with principles of good laboratory practice. In addition, by adjusting the study design an appropriate precision can be achieved to find relevant differences between groups. For the success of the stereological assessment detailed planning is necessary. In this review we focus on common pitfalls encountered during stereological assessment. An exemplary workflow is included, and based on authentic examples, we illustrate a number of sampling principles which can be implemented to obtain properly sampled tissue blocks for various purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study describes the development of and results obtained from the first version of a new mindfulness scale: the Comprehensive Inventory of Mindfulness Experiences beta (CHIME-β). The aim of the present analysis was to investigate two relevant open questions in mindfulness assessment: (1) the coverage of aspects of mindfulness and (2) the type of interrelationships among these aspects. A review of the aspects of mindfulness assessed by eight currently available mindfulness questionnaires led to the identification of nine aspects of mindfulness. The CHIME-β was constructed in order to cover each of these aspects in a balanced way. Initially, principal component and confirmatory factor analyses, as well as reliability and validity analyses, were performed in the entire sample (n = 313) of individuals from the general population and mindfulness-based stress reduction (MBSR) groups. The factor structure that emerged from this analysis was further investigated in meditation-trained individuals (n = 144) who had just completed an MBSR intervention. Results suggested a four-factor structure underlying the nine aspects proposed. The relationship between these mindfulness factors appears to be influenced by the degree of meditation experience. In fact, the mindfulness factors showed a greater interconnectedness among mediation-trained participants. Finally, data suggest that a non-avoidant stance plays a central role in mindfulness, while the capacity to put inner experiences into words may be related to mindfulness rather than a component of the construct.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surface temperature is a key aspect of weather and climate, but the term may refer to different quantities that play interconnected roles and are observed by different means. In a community-based activity in June 2012, the EarthTemp Network brought together 55 researchers from five continents to improve the interaction between scientific communities who focus on surface temperature in particular domains, to exploit the strengths of different observing systems and to better meet the needs of different communities. The workshop identified key needs for progress towards meeting scientific and societal requirements for surface temperature understanding and information, which are presented in this community paper. A "whole-Earth" perspective is required with more integrated, collaborative approaches to observing and understanding Earth's various surface temperatures. It is necessary to build understanding of the relationships between different surface temperatures, where presently inadequate, and undertake large-scale systematic intercomparisons. Datasets need to be easier to obtain and exploit for a wide constituency of users, with the differences and complementarities communicated in readily understood terms, and realistic and consistent uncertainty information provided. Steps were also recommended to curate and make available data that are presently inaccessible, develop new observing systems and build capacities to accelerate progress in the accuracy and usability of surface temperature datasets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

MicroRNAs (miRNAs) silence the expression of their mRNA targets mainly by promoting mRNA decay. The mechanism, kinetics and participating enzymes for miRNA-mediated decay in mammalian cells remain largely unclear. Combining the approaches of transcriptional pulsing, RNA tethering, overexpression of dominant-negative mutants, and siRNA-mediated gene knockdown, we show that let-7 miRNA-induced silencing complexes (miRISCs), which contain the proteins Argonaute (Ago) and TNRC6 (also known as GW182), trigger very rapid mRNA decay by inducing accelerated biphasic deadenylation mediated by Pan2-Pan3 and Ccr4-Caf1 deadenylase complexes followed by Dcp1-Dcp2 complex-directed decapping in mammalian cells. When tethered to mRNAs, all four human Ago proteins and TNRC6C are each able to recapitulate the two deadenylation steps. Two conserved human Ago2 phenylalanines (Phe470 and Phe505) are critical for recruiting TNRC6 to promote deadenylation. These findings indicate that promotion of biphasic deadenylation to trigger mRNA decay is an intrinsic property of miRISCs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A two-pronged approach for the automatic quantitation of multiple sclerosis (MS) lesions on magnetic resonance (MR) images has been developed. This method includes the design and use of a pulse sequence for improved lesion-to-tissue contrast (LTC) and seeks to identify and minimize the sources of false lesion classifications in segmented images. The new pulse sequence, referred to as AFFIRMATIVE (Attenuation of Fluid by Fast Inversion Recovery with MAgnetization Transfer Imaging with Variable Echoes), improves the LTC, relative to spin-echo images, by combining Fluid-Attenuated Inversion Recovery (FLAIR) and Magnetization Transfer Contrast (MTC). In addition to acquiring fast FLAIR/MTC images, the AFFIRMATIVE sequence simultaneously acquires fast spin-echo (FSE) images for spatial registration of images, which is necessary for accurate lesion quantitation. Flow has been found to be a primary source of false lesion classifications. Therefore, an imaging protocol and reconstruction methods are developed to generate "flow images" which depict both coherent (vascular) and incoherent (CSF) flow. An automatic technique is designed for the removal of extra-meningeal tissues, since these are known to be sources of false lesion classifications. A retrospective, three-dimensional (3D) registration algorithm is implemented to correct for patient movement which may have occurred between AFFIRMATIVE and flow imaging scans. Following application of these pre-processing steps, images are segmented into white matter, gray matter, cerebrospinal fluid, and MS lesions based on AFFIRMATIVE and flow images using an automatic algorithm. All algorithms are seamlessly integrated into a single MR image analysis software package. Lesion quantitation has been performed on images from 15 patient volunteers. The total processing time is less than two hours per patient on a SPARCstation 20. The automated nature of this approach should provide an objective means of monitoring the progression, stabilization, and/or regression of MS lesions in large-scale, multi-center clinical trials. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cardiovascular magnetization transfer ratio (MTR) imaging by steady state free precession is a promising imaging method to assess microstructural changes within the myocardium. Hence, MTR imaging was correlated to histological analysis. Three postmortem cases were selected based on a suspicion of myocardial infarction. MTR and T2 -weighted (T2w ) imaging was performed, followed by autopsy and histological analysis. All tissue abnormalities, identified by autopsy or histology, were retrospectively selected on visually matched MTR and T2w images, and corresponding MTR values compared with normal appearing tissue. Regions of elevated MTR (up to approximately 20%, as compared to normal tissue), appearing hypo-intense in T2w -images, revealed the presence of fibrous tissue in microscopic histological analysis. Macroscopic observation (autopsy) described scar tissue only in one case. Regions of reduced MTR (up to approximately 20%) corresponded either to (i) the presence of edema, appearing hyperintense in T2w -images and confirmed by autopsy, or to (ii) inflammatory granulocyte infiltration at a microscopic level, appearing as hypo-intense T2w -signal, but not observed by autopsy. Findings from cardiovascular MTR imaging corresponded to histology results. In contrast to T2w -imaging, MTR imaging discriminated between normal myocardium, scar tissue and regions of acute myocardial infarction in all three cases. J. Magn. Reson. Imaging 2013. © 2013 Wiley Periodicals, Inc.