306 resultados para Locomotive boilers.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of this paper was to perform an energy assessment of firewood and woodshaving use for energy generation in sericulture agroindustry boilers. In this research, we used a boiler from a silk spinning factory located in the city of Duartina, São Paulo, Brazil, that currently uses eucalyptus firewood as fuel to generate water vapour used in silk fiber production. In the studied fuels utilization system energy consumption structure development, we considered energy input in Megajoule (MJ) by type, source and form involved in several firewood use technical itinerary operations, as well as in woodshaving use technical itinerary operations. From these fuels utilization built structure, we performed a firewood- and woodshaving-generated energy input comparative analysis, in Megajoule/hour (MJ.h-1), to produce 2.968,80 kg.h-1 of vapour, which is the boiler average production, during the following years: 2004, 2005, and 2006. The energy analysis results revealed that to replace eucalyptus firewood with woodshaving is something possible in the boiler, reducing total energy consumption approximately by 21%.
Resumo:
Pós-graduação em Química - IBILCE
Resumo:
Pós-graduação em Química - IBILCE
Resumo:
This article describes a real-world production planning and scheduling problem occurring at an integrated pulp and paper mill (P&P) which manufactures paper for cardboard out of produced pulp. During the cooking of wood chips in the digester, two by-products are produced: the pulp itself (virgin fibers) and the waste stream known as black liquor. The former is then mixed with recycled fibers and processed in a paper machine. Here, due to significant sequence-dependent setups in paper type changeovers, sizing and sequencing of lots have to be made simultaneously in order to efficiently use capacity. The latter is converted into electrical energy using a set of evaporators, recovery boilers and counter-pressure turbines. The planning challenge is then to synchronize the material flow as it moves through the pulp and paper mills, and energy plant, maximizing customer demand (as backlogging is allowed), and minimizing operation costs. Due to the intensive capital feature of P&P, the output of the digester must be maximized. As the production bottleneck is not fixed, to tackle this problem we propose a new model that integrates the critical production units associated to the pulp and paper mills, and energy plant for the first time. Simple stochastic mixed integer programming based local search heuristics are developed to obtain good feasible solutions for the problem. The benefits of integrating the three stages are discussed. The proposed approaches are tested on real-world data. Our work may help P&P companies to increase their competitiveness and reactiveness in dealing with demand pattern oscillations. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
[EN] BACKGROUND: A classic, unresolved physiological question is whether central cardiorespiratory and/or local skeletal muscle circulatory factors limit maximal aerobic capacity (VO2max) in humans. Severe heat stress drastically reduces VO2max, but the mechanisms have never been studied. METHODS AND RESULTS: To determine the main contributing factor that limits VO2max with and without heat stress, we measured hemodynamics in 8 healthy males performing intense upright cycling exercise until exhaustion starting with either high or normal skin and core temperatures (+10 degrees C and +1 degrees C). Heat stress reduced VO2max, 2-legged VO2, and time to fatigue by 0.4+/-0.1 L/min (8%), 0.5+/-0.2 L/min (11%), and 2.2+/-0.4 minutes (28%), respectively (all P<0.05), despite heart rate and core temperature reaching similar peak values. However, before exhaustion in both heat stress and normal conditions, cardiac output, leg blood flow, mean arterial pressure, and systemic and leg O2 delivery declined significantly (all 5% to 11%, P<0.05), yet arterial O2 content and leg vascular conductance remained unchanged. Despite increasing leg O2 extraction, leg VO2 declined 5% to 6% before exhaustion in both heat stress and normal conditions, accompanied by enhanced muscle lactate accumulation and ATP and creatine phosphate hydrolysis. CONCLUSIONS: These results demonstrate that in trained humans, severe heat stress reduces VO2max by accelerating the declines in cardiac output and mean arterial pressure that lead to decrements in exercising muscle blood flow, O2 delivery, and O2 uptake. Furthermore, the impaired systemic and skeletal muscle aerobic capacity that precedes fatigue with or without heat stress is largely related to the failure of the heart to maintain cardiac output and O2 delivery to locomotive muscle.
Resumo:
In un quadro internazionale di forte interesse verso uno sviluppo sostenibile e sfide energetiche per il futuro, il DIEM, in collaborazione con altri istituti di ricerca ed imprese private, sta progettando l’integrazione di componentistica avanzata su di una caldaia alimentata a biomasse. Lo scopo finale è quello di realizzare una caldaia a biomasse che produca energia in maniera più efficiente e con un impatto ambientale ridotto. L’applicazione è indirizzata inizialmente verso caldaie di piccola-media taglia (fino a 350 kW termici) vista la larga diffusione di questa tipologia di impianto. La componentistica in oggetto è: - filtro sperimentale ad alta efficienza per la rimozione del particolato; - celle a effetto Seebeck per la produzione di energia elettrica direttamente da energia termica senza parti meccaniche in movimento; - pompa Ogden per la produzione di energia meccanica direttamente da energia termica; La finalità dell’attività di ricerca è la progettazione dell’integrazione dei suddetti dispositivi con una caldaia a biomassa da 290 kW termici per la realizzazione di un prototipo di caldaia stand-alone ad impatto ambientale ridotto: in particolare, la caldaia è in grado, una volta raggiunte le condizioni di regime, di autoalimentare le proprie utenze elettriche, garantendo il funzionamento in sicurezza in caso di black-out o consentendo l’installazione della caldaia medesima in zone remote e prive di allaccio alla rete elettrica. Inoltre, la caldaia può fornire, tramite l'utilizzo di una pompa a vapore o pompa Ogden, energia meccanica per il pompaggio di fluidi: tale opportunità si ritiene particolarmente interessante per l'integrazione della caldaia nel caso di installazione in ambito agricolo. Infine, l'abbinamento di un filtro ad alta efficienza e basso costo consente l'abbattimento delle emissioni inquinanti, favorendo una maggiore diffusione della tecnologia senza ulteriori impatti sull'ambiente.
Resumo:
La semplicità, affidabilità, robustezza ed economicità del motore asincrono trifase ne fanno un motore largamente utilizzato sia in ambiente industriale che civile (pompe, ascensori, montacarichi, nastri trasportatori, ventilatori, locomotive ferroviarie, …). È ipotizzabile che in futuro vi sarà sempre più largo impiego di motori elettrici e i recenti sviluppi nella tecnologia dei convertitori elettronici per il controllo dei motori asincroni ne consentiranno l’uso in sempre più estesi ambiti applicativi. La messa sotto tensione di motori a media/alta potenza presenta però, in fase di avviamento, correnti di spunto e coppie elevate che devono essere controllate. In questa tesi saranno pertanto studiate le tecniche di protezione, avviamento e controllo dei motori asincroni trifase Nel primo capitolo esamineremo le funzioni di sezionamento, comando e protezione da cortocircuiti e sovraccarichi e i dispositivi adatti a svolgere tale compito in modo coordinato. Nel secondo capitolo esamineremo le principali tecnologie usate per l’avviamento dei motori, da quelle più semplici a quelle che impiegano dispositivi elettronici allo stato solido: Soft-Starters a tiristori (solo regolazione AC), Inverters a transistori (controllo sia in frequenza che ampiezza della forma d’onda AC generata). Fra tutti i possibili convertitori DC/AC analizzeremo dettagliatamente esclusivamente quelli a controllo PWM analogico che costituiranno l’oggetto della trattazione dei capitoli seguenti.
Resumo:
Space-based (satellite, scientific probe, space station, etc.) and millimeter – to – microscale (such as are used in high power electronics cooling, weapons cooling in aircraft, etc.) condensers and boilers are shear/pressure driven. They are of increasing interest to system engineers for thermal management because flow boilers and flow condensers offer both high fluid flow-rate-specific heat transfer capacity and very low thermal resistance between the fluid and the heat exchange surface, so large amounts of heat may be removed using reasonably-sized devices without the need for excessive temperature differences. However, flow stability issues and degradation of performance of shear/pressure driven condensers and boilers due to non-desirable flow morphology over large portions of their lengths have mostly prevented their use in these applications. This research is part of an ongoing investigation seeking to close the gap between science and engineering by analyzing two key innovations which could help address these problems. First, it is recommended that the condenser and boiler be operated in an innovative flow configuration which provides a non-participating core vapor stream to stabilize the annular flow regime throughout the device length, accomplished in an energy-efficient manner by means of ducted vapor re-circulation. This is demonstrated experimentally. Second, suitable pulsations applied to the vapor entering the condenser or boiler (from the re-circulating vapor stream) greatly reduce the thermal resistance of the already effective annular flow regime. For experiments reported here, application of pulsations increased time-averaged heat-flux up to 900 % at a location within the flow condenser and up to 200 % at a location within the flow boiler, measured at the heat-exchange surface. Traditional fully condensing flows, reported here for comparison purposes, show similar heat-flux enhancements due to imposed pulsations over a range of frequencies. Shear/pressure driven condensing and boiling flow experiments are carried out in horizontal mm-scale channels with heat exchange through the bottom surface. The sides and top of the flow channel are insulated. The fluid is FC-72 from 3M Corporation.
Resumo:
Whole-body vibration exposure of locomotive engineers and the vibration attenuation of seats in 22 U.S. locomotives (built between 1959 and 2000) was studied during normal revenue service and following international measurement guidelines. Triaxial vibration measurements (duration mean 155 min, range 84-383 min) on the seat and on the floor were compared. In addition to the basic vibration evaluation (aw rms), the vector sum (av), the maximum transient vibration value (MTVV/aw), the vibration dose value (VDV/(aw T1/4)), and the vibration seat effective transmissibility factor (SEAT) were calculated. The power spectral densities are also reported. The mean basic vibration level (aw rms) was for the fore-aft axis x = 0.18 m/sec2, the lateral axis y = 0.28 m/sec2, and the vertical axis z = 0.32 m/sec2. The mean vector sum was 0.59 m/sec2 (range 0.27 to 1.44). The crest factors were generally at or above 9 in the horizontal and vertical axis. The mean MTVV/aw was 5.3 (x), 5.1 (y), and 4.8 (z), and the VDV/(aw T1/4) values ranged from 1.32 to 2.3 (x-axis), 1.33 to 1.7 (y-axis), and 1.38 to 1.86 (z-axis), generally indicating high levels of shocks. The mean seat transmissibility factor (SEAT) was 1.4 (x) and 1.2 (y) and 1 (z), demonstrating a general ineffectiveness of any of the seat suspension systems. In conclusion, these data indicate that locomotive rides are characterized by relatively high shock content (acceleration peaks) of the vibration signal in all directions. Locomotive vertical and lateral vibrations are similar, which appears to be characteristic for rail vehicles compared with many road/off-road vehicles. Tested locomotive cab seats currently in use (new or old) appear inadequate to reduce potentially harmful vibration and shocks transmitted to the seated operator, and older seats particularly lack basic ergonomic features regarding adjustability and postural support.
Resumo:
The influence of the nest location and the placement of nipple drinkers on nest use by laying hens in a commercial aviary was assessed. Twenty pens in a laying hen house were equipped with the same commercial aviary system, but the pens differed in the nest location and the placement of nipple drinkers. Nests were placed along the walls in 10 pens, and nipple drinkers were installed in front of the nests in 5 of these pens. The other 10 pens were equipped with nests placed on a tier within the aviary (integrated nests). Nipple drinkers were installed in front of the nests in 5 of these pens. A total of 225 Lohmann Selected Leghorns were housed per pen. The hens were offered 4 nests per pen: 2 facing the service corridor of the laying hen house and 2 facing the outdoor area. The numbers of nest eggs and mislaid eggs were counted daily per pen. At 25, 36, and 43 wk of age, the nest platforms were videotaped and the behavior of laying hens in front of the nests was analyzed. The nest location affected the stationary and locomotive behaviors in front of the nests. Hens in front of the integrated nests and the nests with drinkers displayed more stationary behaviors than hens in front of wall-placed nests or nests without drinkers. No difference in the number of nest eggs could be detected, but the integration of the nests inside the aviary led to a more even distribution of hens while nest searching. In the pens with wall-placed nests, significantly more hens laid eggs in the nests at the wall near the service corridor than at the wall near the outdoor area. Due to this imbalance, crowding in front of the preferred nests occurred and pushing and agonistic interactions on the nest platforms were significantly more frequent. Placement of nipple drinkers in front of nests had no effect on the number of eggs laid in those nests.
Resumo:
The nematode Caenorhabditis elegans is a well-known model organism used to investigate fundamental questions in biology. Motility assays of this small roundworm are designed to study the relationships between genes and behavior. Commonly, motility analysis is used to classify nematode movements and characterize them quantitatively. Over the past years, C. elegans' motility has been studied across a wide range of environments, including crawling on substrates, swimming in fluids, and locomoting through microfluidic substrates. However, each environment often requires customized image processing tools relying on heuristic parameter tuning. In the present study, we propose a novel Multi-Environment Model Estimation (MEME) framework for automated image segmentation that is versatile across various environments. The MEME platform is constructed around the concept of Mixture of Gaussian (MOG) models, where statistical models for both the background environment and the nematode appearance are explicitly learned and used to accurately segment a target nematode. Our method is designed to simplify the burden often imposed on users; here, only a single image which includes a nematode in its environment must be provided for model learning. In addition, our platform enables the extraction of nematode ‘skeletons’ for straightforward motility quantification. We test our algorithm on various locomotive environments and compare performances with an intensity-based thresholding method. Overall, MEME outperforms the threshold-based approach for the overwhelming majority of cases examined. Ultimately, MEME provides researchers with an attractive platform for C. elegans' segmentation and ‘skeletonizing’ across a wide range of motility assays.
Resumo:
Scientific background: Marine mammals use sound for communication, navigation and prey detection. Acoustic sensors therefore allow the detection of marine mammals, even during polar winter months, when restricted visibility prohibits visual sightings. The animals are surrounded by a permanent natural soundscape, which, in polar waters, is mainly dominated by the movement of ice. In addition to the detection of marine mammals, acoustic long-term recordings provide information on intensity and temporal variability of characteristic natural and anthropogenic background sounds, as well as their influence on the vocalization of marine mammals Scientific objectives: The PerenniAL Acoustic Observatory in the Antarctic Ocean (PALAOA, Hawaiian "whale") near Neumayer Station is intended to record the underwater soundscape in the vicinity of the shelf ice edge over the duration of several years. These long-term recordings will allow studying the acoustic repertoire of whales and seals continuously in an environment almost undisturbed by humans. The data will be analyzed to (1) register species specific vocalizations, (2) infer the approximate number of animals inside the measuring range, (3) calculate their movements relative to the observatory, and (4) examine possible effects of the sporadic shipping traffic on the acoustic and locomotive behaviour of marine mammals. The data, which are largely free of anthropogenic noise, provide also a base to set up passive acoustic mitigation systems used on research vessels. Noise-free bioacoustic data thereby represent the foundation for the development of automatic pattern recognition procedures in the presence of interfering sounds, e.g. propeller noise.
Resumo:
El alcance del proyecto es describir las directrices técnicas, la definición de criterios, y la estrategia de suministro de energía (Electricidad. Calefacción y Agua Caliente Sanitaria (ACS)) a un barrio modelo situado en un entorno urbano. De inicio se estudia los diversos modelos energéticos atendiendo a la normativa y tecnología, que se pueden aplicar en un conjunto residencial, dando como resultado el modelo propuesto de abastecimiento energético, mediante calefacción de distrito, que incorporara el diseño de una planta de producción de energía termo-eléctrica o Central de Energías basada en la tecnología de condensación de baja temperatura para calefacción y A.C.S. incluyendo una cogeneración con pila de combustible. Al mismo tiempo se han calculado y diseñado una serie de chimeneas externas para dar cumplida necesidad técnica y legal al proyecto. Estos estudios nos sirven de punto de partida para analizar la amortización de la inversión y por tanto la rentabilidad y viabilidad del proyecto, comparándose con los costes económicos derivados de la generación por sistemas convencionales. Para finalizar se hace mención a las ventajas medioambientales y a los grados de seguridad en la planta de producción ABSTRACT The scope of this work is the description of an energy supply project ( Electricity, heat and hot water ) to a housing development in a urban neibourhood , including technical criteria in their different options. Initially, several solutions are studied based on available technologies and legal restrictions. The final proposal is based on the district hearing model including electricity production in cogeneration via fuel cell technology as well as heating and hot water produced by low temperature condensation boilers It includes calculations and design criteria of the exhaust gases system and chimeneys in compliance with legal requirement in urban areas. This work also includes an economical model including payback, IRR and VAN analysis and an economical comparaison with the standard solutions. Finally, environmental advantages of the preferred solution over other standards as well as safety issues are also presented.
Estudio técnico y económico para la sustitución del gasóleo por biomasa térmica en edificios urbanos
Resumo:
La finalidad del proyecto consiste en realizar la sustitución de calderas de gasóleo por calderas de biomasa para suministrar calefacción a edificios urbanos. En primer lugar, se ha hecho un estudio de la demanda calorífica de los edificios, y posteriormente se ha estudiado el ciclo completo de la biomasa, incluyendo el suministro y tipo de biomasa, dimensiones de los equipos y espacios necesarios para la instalación. Después de estudiar la viabilidad técnica y económica, podemos concluir que utilizar biomasa en edificios con calderas centralizadas nos aporta un gran ahorro en comparación con el gasóleo, además de evitar emisiones de CO2 y utilizar un combustible renovable y de producción nacional. ABSTRACT The purpose of the project consists of performing the substitution of diesel boilers by biomass boilers to provide the heating to urban buildings. In first place, it has been made a study of the calorific demand of the buildings. In addition, it has been studied the completed cycle of the biomass even including the supply and the type of biomass, the dimensions of the machines and the necessary spaces to carry out the installation. After studying the technical and economical viability, we can conclude that using biomass in buildings with central boilers provides us an important saving in comparison with diesel as well as to avoid CO2 emissions and using a renewable combustible of national production.