682 resultados para Ligament


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The jetting of dilute polymer solutions in drop-on-demand printing is investigated. A quantitative model is presented which predicts three different regimes of behaviour depending upon the jet Weissenberg number Wi and extensibility of the polymer molecules. In regime I (Wi < ½) the polymer chains are relaxed and the fluid behaves in a Newtonian manner. In regime II (½ < Wi < L) where L is the extensibility of the polymer chain the fluid is viscoelastic, but the polymer do not reach their extensibility limit. In regime III (Wi > L) the chains remain fully extended in the thinning ligament. The maximum polymer concentration at which a jet of a certain speed can be formed scales with molecular weight to the power of (1-3ν), (1-6ν) and -2ν in the three regimes respectively, where ν is the solvent quality coefficient. Experimental data obtained with solutions of mono-disperse polystyrene in diethyl phthalate with molecular weights between 24 - 488 kDa, previous numerical simulations of this system, and previously published data for this and another linear polymer in a variety of “good” solvents, all show good agreement with the scaling predictions of the model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Satellite droplets are unwanted in inkjet printing and various approaches have been suggested for their reduction. Low jetting speeds limit applications of the process. Added surfactants for wetting and conductivity enhancement may help but dynamic surface tension effects may counteract improvements. A higher fluid viscosity delays ligament break-up, but also leads to slower jets, while viscoelasticity reduces satellite formation only in certain cases. We show here that aqueous solutions of PEDOT:PSS (1:2.5 by weight) are strongly shear-thinning. They exhibit low viscosity within the printing nozzle over a wide range of jet speeds, yet rapidly (<100 μs) recover a higher viscosity at the low shear rates applicable once the jet has formed, which give the benefit of delayed satellite formation. The delay over a 0.8 mm stand-off distance can be sufficient to completely suppress satellites, which is significant for many printing applications. © 2012 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fluid assessment methods, requiring small volumes and avoiding the need for jetting, are particularly useful in the design of functional fluids for inkjet printing applications. With the increasing use of complex (rather than Newtonian) fluids for manufacturing, single frequency fluid characterisation cannot reliably predict good jetting behaviour, owing to the range of shearing and extensional flow rates involved. However, the scope of inkjet fluid assessments (beyond achievement of a nominal viscosity within the print head design specification) is usually focused on the final application rather than the jetting processes. The experimental demonstration of the clear insufficiency of such approaches shows that fluid jetting can readily discriminate between fluids assessed as having similar LVE characterisation (within a factor of 2) for typical commercial rheometer measurements at shearing rates reaching 104rads-1.Jetting behaviour of weakly elastic dilute linear polystyrene solutions, for molecular weights of 110-488. kDa, recorded using high speed video was compared with recent results from numerical modelling and capillary thinning studies of the same solutions.The jetting images show behaviour ranging from near-Newtonian to "beads-on-a-string". The inkjet printing behaviour does not correlate simply with the measured extensional relaxation times or Zimm times, but may be consistent with non-linear extensibility L and the production of fully extended polymer molecules in the thinning jet ligament.Fluid test methods allowing a more complete characterisation of NLVE parameters are needed to assess inkjet printing feasibility prior to directly jetting complex fluids. At the present time, directly jetting such fluids may prove to be the only alternative. © 2014 The Authors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To study the brittle-ductile transition (BDT) of polypropylene (PP)/ethylene-propylene-diene monomer (EPDM) blends induced by size, temperature, and time, the toughness of the PP/EPDM blends was investigated over wide ranges of EPDM content, temperature, and strain rate. The toughness of the blends was determined from the tensile fracture energy of the side-edge notched samples. The concept of interparticle distance (ID) was introduced into this study to probe the size effect on the BDT of PP/EPDM blends, whereas the effect of time corresponded to that of strain rate. The BDT induced by size, temperature, and time was observed in the fracture energy versus ID, temperature, and strain rate. The critical BDT temperatures for various EPDM contents at different initial strain rates were obtained from these transitions. The critical interparticle distance (IDc) increased nonlinearly with increasing temperature, and when the initial strain rate was lower, the IDc was larger. Moreover, the variation of the reciprocal of the initial strain rate with the reciprocal of temperature followed different straight lines for various EPDM contents. These straight lines were with the same slope.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The seismic survey is the most effective geophysical method during exploration and development of oil/gas. As a main means in processing and interpreting seismic data, impedance inversion takes up a special position in seismic survey. This is because the impedance parameter is a ligament which connects seismic data with well-logging and geological information, while it is also essential in predicting reservoir properties and sand-body. In fact, the result of traditional impedance inversion is not ideal. This is because the mathematical inverse problem of impedance is poor-pose so that the inverse result has instability and multi-result, so it is necessary to introduce regularization. Most simple regularizations are presented in existent literature, there is a premise that the image(or model) is globally smooth. In fact, as an actual geological model, it not only has made of smooth region but also be separated by the obvious edge, the edge is very important attribute of geological model. It's difficult to preserve these characteristics of the model and to avoid an edge too smooth to clear. Thereby, in this paper, we propose a impedance inverse method controlled by hyperparameters with edge-preserving regularization, the inverse convergence speed and result would be improved. In order to preserve the edge, the potential function of regularization should satisfy nine conditions such as basic assumptions edge preservation and convergence assumptions etc. Eventually, a model with clear background and edge-abnormity can be acquired. The several potential functions and the corresponding weight functions are presented in this paper. The potential functionφLφHL andφGM can meet the need of inverse precision by calculating the models. For the local constant planar and quadric models, we respectively present the neighborhood system of Markov random field corresponding to the regularization term. We linearity nonlinear regularization by using half-quadratic regularization, it not only preserve the edge, and but also simplify the inversion, and can use some linear methods. We introduced two regularization parameters (or hyperparameters) λ2 and δ in the regularization term. λ2 is used to balance the influence between the data term and the transcendental term; δ is a calibrating parameter used to adjust the gradient value at the discontinuous position(or formation interface). Meanwhile, in the inverse procedure, it is important to select the initial value of hyperparameters and to change hyperparameters, these will then have influence on convergence speed and inverse effect. In this paper, we roughly give the initial value of hyperparameters by using a trend- curve of φ-(λ2, δ) and by a method of calculating the upper limit value of hyperparameters. At one time, we change hyperparameters by using a certain coefficient or Maximum Likelihood method, this can be simultaneously fulfilled with the inverse procedure. Actually, we used the Fast Simulated Annealing algorithm in the inverse procedure. This method overcame restrictions from the local extremum without depending on the initial value, and got a global optimal result. Meanwhile, we expound in detail the convergence condition of FSA, the metropolis receiving probability form Metropolis-Hasting, the thermal procession based on the Gibbs sample and other methods integrated with FSA. These content can help us to understand and improve FSA. Through calculating in the theoretic model and applying it to the field data, it is proved that the impedance inverse method in this paper has the advantage of high precision practicability and obvious effect.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Medicina Dentária

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Despite recent increases in the volume of research in professional rugby union, there is little consensus on the epidemiology of injury in adolescent players. We undertook a systematic review to determine the incidence, severity, and nature of injury in adolescent rugby union players.

DATA SOURCES: In April 2009, we performed a computerized literature search on PubMed, Embase, and Cochrane Controlled Trials Register (via Ovid). Population-specific and patient-specific search terms were combined in the form of MEDLINE subject headings and key words (wound$ and injur$, rugby, adolescent$). These were supplemented with related-citation searches on PubMed and bibliographic tracking of primary and review articles.

STUDY SELECTION: Prospective epidemiologic studies in adolescent rugby union players.

DATA SYNTHESIS: A total of 15 studies were included, and the data were analyzed descriptively. Two independent reviewers extracted key study characteristics regarding the incidence, severity, and nature of injuries and the methodologic design.

CONCLUSIONS: Wide variations existed in the injury definitions and data collection procedures. The incidence of injury necessitating medical attention varied with the definition, from 27.5 to 129.8 injuries per 1000 match hours. The incidence of time-loss injury (>7 days) ranged from 0.96 to 1.6 per 1000 playing hours and from 11.4/1000 match hours (>1 day) to 12-22/1000 match hours (missed games). The highest incidence of concussion was 3.3/1000 playing hours. No catastrophic injuries were reported. The head and neck, upper limb, and lower limb were all common sites of injury, and trends were noted toward greater time loss due to upper limb fractures or dislocations and knee ligament injuries. Increasing age, the early part of the playing season, and the tackle situation were most closely associated with injury. Future injury-surveillance studies in rugby union must follow consensus guidelines to facilitate interstudy comparisons and provide further clarification as to where injury-prevention strategies should be focused.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effect of preparation design and the physical properties of the interface lute on the restored machined ceramic crown-tooth complex are poorly understood. The aim of this work was to determine, by means of three-dimensional finite element analysis (3D FEA) the effect of the tooth preparation design and the elastic modulus of the cement on the stress state of the cemented machined ceramic crown-tooth complex. The three-dimensional structure of human premolar teeth, restored with adhesively cemented machined ceramic crowns, was digitized with a micro-CT scanner. An accurate, high resolution, digital replica model of a restored tooth was created. Two preparation designs, with different occlusal morphologies, were modeled with cements of 3 different elastic moduli. Interactive medical image processing software (mimics and professional CAD modeling software) was used to create sophisticated digital models that included the supporting structures; periodontal ligament and alveolar bone. The generated models were imported into an FEA software program (hypermesh version 10.0, Altair Engineering Inc.) with all degrees of freedom constrained at the outer surface of the supporting cortical bone of the crown-tooth complex. Five different elastic moduli values were given to the adhesive cement interface 1.8 GPa, 4 GPa, 8 GPa, 18.3 GPa and 40 GPa; the four lower values are representative of currently used cementing lutes and 40 GPa is set as an extreme high value. The stress distribution under simulated applied loads was determined. The preparation design demonstrated an effect on the stress state of the restored tooth system. The cement elastic modulus affected the stress state in the cement and dentin structures but not in the crown, the pulp, the periodontal ligament or the cancellous and cortical bone. The results of this study suggest that both the choice of the preparation design and the cement elastic modulus can affect the stress state within the restored crown-tooth complex.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The inflammatory response to pulpal injury or infection has major clinical significance. Osteoprotegerin (OPG) is a soluble decoy receptor for Receptor Activator of NF kappa B Ligand (RANKL), preventing ligand binding to its receptor (RANK), thus inhibiting clastic cell formation. The aim of the study is to investigate the expression of OPG in human dental pulp and the effects of inflammatory mediators. This study will specifically investigate the effects of Transforming Growth Factor Beta-1 (TGF-β1) and Interleukin 1-Beta (IL-1β) on the expression of OPG on pulp fibroblasts in vitro. Method: Five primary pulp fibroblast populations were obtained by explant culture of healthy pulp tissue. Triplicate cultures were grown to confluence in 12-well plates and stimulated for 48 hours with IL-1β (10ng/ml) or TGF-β1 (10ng/ml). The conditioned media was collected and OPG levels detected by ELISA (R+D Systems, UK). Results: All fibroblast populations produced quantifiable levels of OPG in a time-dependant fashion. IL-1β significantly increased the expression of OPG (p<0.05) in all cultures. In contrast, TGF-β1 had no significant effect on OPG expression levels. In addition, previous work in our laboratory demonstrated both TGF-β1 and IL-1β stimulated OPG expression by periodontal ligament fibroblasts. Conclusion: These data indicate that IL-1β-regulated expression of OPG by pulpal fibroblasts may mediate hard tissue turnover in the inflamed dental pulp.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The accurate determination of non-linear shear behaviour and fracture toughness of continuous carbon-fibre/polymer composites remains a considerable challenge. These measurements are often necessary to generate material parameters for advanced computational damage models. In particular, there is a dearth of detailed shear fracture toughness characterisation for thermoplastic composites which are increasingly generating renewed interest within the aerospace and automotive sectors. In this work, carbon fibre (AS4)/ thermoplastic Polyetherketoneketone (PEKK) composite V-notched cross-ply specimens were manufactured to investigate their non-linear response under pure shear loading. Both monotonic and cyclic loading were applied to study the shear modulus degradation and progressive failure. For the first time in the reported literature, we use the essential work of fracture approach to measure the shear fracture toughness of continuous fibre reinforced composite laminates. Excellent geometric similarity in the load-displacement curves was observed for ligament-scaled specimens. The laminate fracture toughness was determined by linear regression, of the specific work of fracture values, to zero ligament thickness, and verified with computational models. The matrix intralaminar fracture toughness (ply level fracture toughness), associated with shear loading was determined by the area method. This paper also details the numerical implementation of a new three-dimensional phenomenological model for carbon fibre thermoplastic composites using the measured values, which is able to accurately represent the full non-linear mechanical response and fracture process. The constitutive model includes a new non-linear shear profile, shear modulus degradation and load reversal. It is combined with a smeared crack model for representing ply-level damage initiation and propagation. The model is shown to accurately predict the constitutive response in terms of permanent plastic strain, degraded modulus as well as load reversal. Predictions are also shown to compare favourably with the evolution of damage leading to final fracture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução: É reconhecida a importância do ligamento cruzado anterior (LCA) no funcionamento normal do joelho. Em caso de rotura ligamentar, nomeadamente em desportos com marcada solicitação dos movimentos de rotação do joelho, é justificada a necessidade de reconstrução do LCA na maioria dos casos. Objetivo (s): Avaliar a influência do tipo de enxerto na reconstrução do ligamento cruzado anterior na força muscular isocinética, assim como na funcionalidade e sintomas após 6 meses. Métodos: Estudo transversal analítico, constituído por 20 indivíduos voluntários do sexo masculino, que haviam sido submetidos a uma ligamentoplastia do cruzado anterior, pelo mesmo cirurgião, seguido de uma intervenção individualizada por um fisioterapeuta. Em 10 indivíduos, o procedimento cirúrgico foi realizado com enxerto do tendão rotuliano (grupo OTO), e nos restantes 10 com enxerto do semitendinoso e gracilis (grupo STG). Como forma de avaliar a Força Muscular Isocinética (Peak Torque, Trabalho Total Muscular, ratio Isquiotibiais/Quadricipite), foi utilizado o Dinamómetro Isocinético Biodex. A avaliação foi efectuada apenas aos 6 meses após o procedimento cirúrgico. Para observação da funcionalidade, amplitude de movimento e sintomas, utilizou-se o questionário International Knee Documentation Committee (IKDC). Resultados: Foi possível observar que entre os grupos apenas se observaram diferenças significativas no peak torque de extensão a 180º no membro não lesado (p=0,019). Contudo, foi observada uma tendência para o grupo OTO apresentar um maior défice no peak torque e trabalho total muscular em extensão. Comparativamente ao membro contra-lateral, o membro lesado apresentou valores significativamente inferiores na maioria das variáveis ( p < 0,05). Conclusão: Após 6 meses de pós-cirúrgico com reabilitação de fisioterapia, não foi possível apontar qual o enxerto que garante uma melhor recuperação da força muscular. Aos 6 meses, ambos os grupos ainda apresentaram limitações musculares, quando comparados com o lado contra-lateral. Relativamente ao rácio isquiotibiais/quadricípite, assim como no IKDC, não se observaram diferenças entre os dois tipos de enxertos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Paragangliomas are rare tumors, with a reported incidence of 2–8 per million. They are chromaffin cell tumors that develop from the neural crest cells and may be divided in tumors derived from the parasympathetic or sympathetic ganglia. We report a case a of a 32-year-old nulliparous woman, referred to our Infertility Clinic. Abdomino-pelvic ultrasound identified a large abdominopelvic tumor, without ovarian origin (both ovaries were identified and had normal morphology). Magnetic Resonance Imaging suggested a right adnexal multicystic, vascularized mass close to iliac vessels and questioning an ovarian origin. At exploratory laparotomy, a 10 cm encapsulated and vascularized mass was found beginning just below right renal artery and extending to the level of the broad ligament. This mass was totally excised and histopathology was consistent with Paraganglioma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMO: Na descrição deste estudo foi utilizada a terminologia anatómica da Sociedade Brasileira de Anatomia adaptada ao português por J. A. Esperança-Pina de acordo com o tratado Anatomia Humana da Relação. Os actuais estudos sobre hipoacusia sensorioneural implicam um grupo crescente de situações, em que a lesão se situa ao nível da microvascularização coclear, daí que o conhecimento exacto da angiomorfologia normal se torne essencial na fase actual do conhecimento. A autora tem vindo a estudar, desde 1986, a angiomorfologia do ouvido Interno no modelo experimental, o Cobaio, utilizando várias técnicas microvasculares. sendo dado enfâse particular neste estudo à técnica de microscopia electrónica de varrimento em moldes vasculares. Os animais usados no presente estudo pertencem à espécie cavia porcellus, cobaio, por serem considerados na comunidade cientifica internacional como o melhor modelo experimental para estudo do ouvido interno, pelo facto de a morfologia coclear ser muito semelhante à do Homem e por isso ser um modelo fiável para cirurgia experimental e microdissecção. Este estudo foi realizado em 100 cobaios, cavia porcellus, de ambos os sexos com peso médio de 450g. A vascularização do ouvido interno, no cobaio como no homem, faz-se através dos ramos de divisão da artéria auditiva interna ou labiríntica. A artéria labiríntica origina-se como ramo colateral da artéria cerebelosa ântero-inferior a qual tem origem na artéria basilar ou na artéria vertebral. Embora no homem a artéria auditiva interna possa também destacar-se da artéria basilar e até da artéria vertebral, no cobaio em todos os casos estudados a sua origem verificou-se sempre na artéria cerebelosa ântero-inferior. A artéria labiríntica, ao passar abaixo do meato auditivo interno, divide-se na artéria vestibular anterior e na artéria coclear comum.A artéria vestibular anterior dirige-se para o nervo vestibular, emite vasa nervorum para este nervo e vasculariza o utrículo e os canais semicirculares. A artéria coclear comum origina dois ramos principais, a artéria vestíbulo‑coclear ou vestibular posterior no cobaio, a qual se destaca junto à espira basal da cóclea e a artéria coclear, como ramo terminal, que passa a denominar-se de artéria modiolar ou espiralada, após entrar no modíolo. A artéria modiolar ascende no modíolo promovendo através dos seus ramos colaterais e dos seus ramos terminais a microvascularização coclear, numa vascularização de órgão de tipo terminal. Ao longo do seu trajecto verificou‑se de modo constante uma redução gradual de calibre em cada uma das espiras, por emissão de ramos colaterais, sendo que o calibre da artéria na base da cóclea apresenta um valor que diminui gradualmente até ao ápice. A artéria modiolar origina em todo o seu trajecto ramos colaterais, cujo número diminui em valor absoluto da base para o ápice: Arteríolas radiárias internas, arteríolas de trajecto flexuoso que caminham junto às estruturas sensorioneurais da parede interna da cóclea, junto ao lábio timpânico da lâmina espiral óssea e na parede do próprio modíolo, que se relacionam intimamente com este. As arteríolas radiárias internas originam‑se no flanco da artéria modiolar espiralada. Contam‑se dez a doze em cada espira, extraordinariamente flexuosas desde a sua origem. As arteríolas radiárias internas originam como ramos colaterais, vários grupos de arteríolas de menor calibre, que vascularizam distintas regiões da parede interna da cóclea, as arteríolas do gânglio espiral, a rede espiral interna, as arteríolas de origem dos glomérulos de Schwalbe e a arteríola da lâmina basilar. As arteríolas radiárias externas importantes ramos colaterais da artéria modiolar espiralada promovem a vascularização de importantes estruturas da parede externa. Ao atingir o limite externo do ligamento espiral, as arteríolas radiárias externas dividem‑se em vários ramos arteriolares de menor calibre, ao longo da convexidade do limite externo do ligamento espiral, originando a rede capilar pós-estriada que ocupa a porção lateral do ligamento espiral e a rede capilar ad‑ -estriada, na sua porção mais medial em íntima relação com a estria vascular. A espira basal da cóclea apresenta grande riqueza de vascularização, com características particulares apenas a esta espira, a qual é metabolicamente a mais exigente. A arteríola da janela da cóclea aborda a janela da cóclea pela sua convexidade e divide-se numa rica rede vascular da qual emergem arteríolas pré-capilares que se ramificam em capilares, os quais se dirigem em profundidade penetrando a rampa timpânica da cóclea ao nível da espira basal. Importou neste estudo verificar quais as semelhanças em termos de calibre de estruturas análogas, na parede interna e na parede externa da cóclea, com particular incidência na rede capilar. Do estudo estatístico realizado com testes paramétricos de Tamahane e não paramétricos de Mann-Whitney, verifica-se que comparando todas as estruturas consideradas estas têm calibres diferentes, com excepção dos capilares da estria vascular e do ligamento espiral, pertencentes à parede externa da cóclea que têm calibres iguais aos capilares da rede espiral interna e aos capilares da parede interna da cóclea, dependentes das arteríolas da rede espiral interna. As redes capilares dependentes das arteríolas radiárias internas que vascularizam as estruturas sensorioneurais junto á parede interna do modiolo são em tudo semelhantes em termos de calibre às redes capilares da parede externa da cóclea, incluindo os capilares da estria vascular. Esta particularidade traduz num órgão com vascularização de tipo terminal,um mecanismo de controlo do fluxo sanguíneo coclear tão importante na parede interna como na parede externa da cóclea. ------------ ABSTRACT:Current studies on sensorineural hearing loss, imply a growing group of situations in which the lesion is located at the level of the cochlear microvasculature, hence the exact knowledge of normal angiomorfology becomes essential in current state of knowledge. The author has been studying since 1986, the angiomorfology of inner on the experimental model, the guinea pig, using various microvascular techniques being given particular emphasis in this study to the results of the technique of scanning electron microscopy on corrosion casts. The animals used in this study belong to the species cavia porcellus, guinea pig, to be considered in the international scientific community as the best experimental model for the study of the inner ear, the cochlear morphology is very similar to human and therefore a reliable model for experimental surgery and microdissection. This study was performed in 100 guinea pigs of both sexes with average weight of 450g. There shall be a brief description of embryology, anatomy and cochlear physiology in the light of developmental biology, regarding also the spatial location of the cochlea and the determinism of morphogenetic fields in their development and function. The cochlear transduction mechanism converts the sound wave in stimuli sound and so afferent auditory nerve fibres and deafness are closely related to the cochlear microvasculature. Cochlear ischemia is accompanied by immediate hearing loss. The different type of cochlear injury that leads to sensorineural deafness is well studied in presbycusis where an objective link with the audiometric pattern as been established. The sensory type of deafness, is closely related to the degeneracy of the organ of Corti and damage to the outer hair cells at the basal turn of the cochlea. Keeping in mind cochlear tonotopy with location of high frequency sounds at the level of the base of the cochlea, it explains the audiometric pattern with loss in high frequencies. The neural type of deafness, is characterized by neuronal loss with loss of descendant important neuronal afferents, with audiometric translation on a gradually curve with important loss of auditory discrimination. The metabolic type of deafness results in atrophy of the vascular stria, with consequent change in the potential of the endolymph by decreasing the vascular stria cells and changes in K + recycling mechanism. There is also a change in the morphology of the spiral ligament and the audiometric patern as a flattened curve with loss at all frequencies. Bearing in mind cochlear tonotopy and being characterized all types of sensorineural deafness, we may inquire to what extent the cochlear microvasculature, considering not only the cochlea as a whole but different regions of the inner wall and the outer wall of the cochlea, contributes to deafness. We analysed the entire cochlear morphology on scanning electron microscopy with particular emphasis on bone and membranous cochlea. The inner wall of the cochlea and intramodiolar structures such as the spiral ganglion, the morphology of its cell bodies and their axons are analyzed. The morphology of Corti’s organ is described in detail, with description and large detail of the inner and outer hair cells. Is then presented the study of the microvasculature itself. The spiral modiolar artery is observed with the diaphanization technique and the technique of scanning electron microscopy on corrosion vascular casts. After emergence of collateral branches of the greatest importance, the radiating internal and external arterioles, the modiolar artery gives rise to its terminal branches, the arterioles of the cochear apex. Arterial vasa vasorum and vasa nervorum are displayed with a great detail, which was not yet described in such detail in previous microvascular studies. The arterial radiating arterioles originate in the flank of the spiral modiolar artery in number of ten to twelve in each loop, and they vascularize through their branches the inner wall cochlear sensorineural structures located in the modiolus as the spiral ganglion and structures near the organ of Corti. Their caliber is above 20 μm on the basal turn and in the second loop it decreases to values between 12 and 20 μm, decreasing progressively to the apex of the cochlea.They arise near the modiolus or on their way in the spiral lamina forming vascular loops, and divide without presenting vascular constrictions in their divisions, originating new vascular loops of lower caliber. Internal ratiating arterioles originate as collateral branches several groups of smaller caliber arterioles, which vascularize distinct regions of the inner wall of the cochlea namely, the arterioles of the spiral ganglion, the internal spiral network, the arterioles of origin of the glomeruli of Schwalbe and the arterioles of the basilar membrane. The glomeruli of Schwalbe play an important functional role as relay-stations, in hemodynamic terms, to control the cochlear microvasculature. External radiating arterioles have their origin in the spiral modiolar artery, they are directed towards the outer wall of the cochlea and run through the roof of the scala vestibuli. Above the insertion of Reissner’s membrane on the external wall the external radiating arterioles originate the spiral ligament arterioles, which vascularize the spiral ligament, they divide into several arteriolar branches of smaller caliber, along the convexity of the outer edge of the spiral ligament. The connective tissue of the spiral ligament forms a mesh with supporting function of the highly specialized epithelium, where pericytes were identifiable. Next to its base there is the microvascular network of stria vascularis. The adstriated vascular network which is divided into a capillary network, the capillary network of stria vascularis. The stria vascularis, the only vascularized epithelium of the human body, plays an important role, forming an haemato-labyrintine barrier to assure labyrinthine endocochlear potential and transport of ions, essential for the mechanism of transduction of external hair cells. The cochlear basal turn has a special feature on its external wall, the region of the windows, the round windows giving access to scala tympani and the oval window thatleads into scala vestibuli, and so it is metabolic demanding. For their role in cochlear tonotopy the sensorineural structures and those of the external wall of the cochlea, are particularly vulnerable to hypoxia. Although the complementarity of all the techniques was important for three- -dimensional reconstruction of the microvasculature of the cochlea, the scanning electron microscopy technique, especially when we used the system Semafore was fundamental to perform precise morphometric mesures regarding all vascular structures.Regarding the capillaries of the inner and outer wall of the cochlea networks this technique allowed their characterization in morphometric terms. To conclude the capillaries of the inner wall and of the external wall of the cochlea have similar size. So although located at different cochlear regions, with a different functional role, in cochlear physiology these networks consist of capillaries of similar caliber. It seems to translate a cochlear blood flow control mechanism that is so important in the inner wall as in and the external wall of the cochlea to provide for in inner ear homeosthasia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pelvic floor anatomy is complex and its three-dimensional organization is often difficult to understand for both undergrad- uate and postgraduate students. Here, we focused on several critical points that need to be considered when teaching the perineum. We have to deal with a mixed population of students and with a variety of interest. Yet, a perfect knowledge of the pelvic floor is the basis for any gynecologist and for any surgical intervention. Our objectives are several-fold; i) to estab- lish the objectives and the best way of teaching, ii) to identify and localize areas in the female pelvic floor that are suscepti- ble to generate problems in understanding the three-dimensional organization, iii) to create novel approaches by respecting the anatomical surroundings, and iv) prospectively, to identify elements that may create problems during surgery i.e. to have a closer look at nerve trajectories and on compression sites that may cause neuralgia or postoperative pain. A feedback from students concludes that they have difficulties to assimilate this much information, especially the different imaging tech- niques. Eventually, this will lead to a severe selection of what has to be taught and included in lectures or practicals. Another consequence is that more time to study prosected pelves needs to be given.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La douleur articulaire associée à l’arthrose est un problème clinique majeur, spécialement chez les personnes âgées. L’intensité de la douleur est souvent amplifiée lors de mouvement de l’articulation et principalement lors du soutien de la charge corporelle sur le membre lésé. Malheureusement, les traitements pharmacologiques proposés sont trop souvent associés à des effets secondaires néfastes et à une inefficacité pour le soulagement de la douleur à long terme. Divers modèles murins sont utilisés en laboratoire de recherche pour des études précliniques de molécules aux propriétés analgésiques. Une évaluation comparative de la réponse comportementale douloureuse des animaux d’un modèle d’instabilité articulaire induit par le sectionnement du ligament croisé antérieur accompagné d’une méniscectomie partielle (le modèle ACLT+pMMx) et d’un modèle de dégénérescence articulaire induite par le monoiodoacetate (le modèle MIA) a permis de sélectionner un modèle approprié pour la continuité du projet. Les deux modèles ont démontré des lésions tissulaires, mais le modèle MIA a démontré une réponse douloureuse plus prononcée que le modèle ACLT+pMMx. Par l’analyse de la démarche, le modèle MIA a démontré une boiterie claire dans le patron de la démarche des animaux qui est associée à une lésion unilatérale. Le modèle MIA a donc été choisi pour la suite du projet. La problématique principale dans la recherche sur la douleur associée à l’arthrose est une compréhension incomplète des mécanismes de douleur responsables de l’induction et du maintien de l’état de douleur. Il devient donc nécessaire d’améliorer nos connaissances de ces mécanismes en effectuant une caractérisation plus approfondie des modèles animaux employés pour l’évaluation de stratégies pharmacologiques analgésiantes. Afin de bien comprendre le modèle MIA, une caractérisation des événements moléculaires centraux lors de la progression du processus dégénératif des structures articulaires de ce modèle s’est effectuée aux jours 3, 7, 14, 21 et 28 post injection. Des mécanismes hétérogènes qui modulent l’information nociceptive en fonction de la progression temporelle de la pathologie ont été observés. Les changements du contenu i spinal des neuropeptides sélectionnés (substance P, CGRP, dynorphine A et Big dynorphine) ont débuté sept jours suivant l’injection de MIA. L’observation histologique a démontré que les dommages structuraux les plus importants surviennent entre les jours 14 et 21. C’est entre les jours 7 et 21 que les lésions démontrent le plus de similarités à la pathologie humaine. Cela suggère que lors d’une évaluation préclinique d’un traitement pharmacologique pour pallier la douleur articulaire utilisant le modèle MIA, l’étude doit tenir compte de ces événements afin de maximiser l’évaluation de son efficacité. Puisque les traitements pharmacologiques conventionnels proposés pour le soulagement de la douleur ne font pas l’unanimité en terme d’efficacité, d’effets non désirés et de coûts monétaires parfois onéreux, les molécules de dérivés de plante deviennent une alternative intéressante. L’eugénol, le principal constituant de l’huile de clou de girofle, a été administré oralement pour une période de 28 jours chez des rats ayant reçu l’injection intra-articulaire de MIA afin d’évaluer son efficacité pour le traitement de la douleur articulaire. L’eugénol à une dose de 40 mg/kg s’est révélé efficace pour l’amélioration du patron de la démarche des animaux ainsi que pour la diminution de l’allodynie mécanique secondaire. De plus, les concentrations spinales de neuropeptides pronocicepteurs ont diminué chez les animaux traités. Par une évaluation histopathologique, l’eugénol n’a démontré aucune évidence d’effets toxiques suite à une administration per os quotidienne pour une période prolongée. Ces résultats suggèrent le potentiel thérapeutique complémentaire de la molécule d’eugénol pour le traitement de la douleur articulaire.