907 resultados para Laser diode array
Resumo:
提出了一种基于人工神经网络的全光纤化大量程实时距离干涉测量仪.采用双正弦相位调制方法,即通过同时调制半导体激光器的波长和干涉仪的光程差实现外差测量。为了扩大干涉仪的测量范围和消除输出信号中的交叉敏感,采用人工神经网络进行信号处理,把两路经过初步解调的干涉信号作为输入样本,物体距离的实际值作为输出样本,对神经网络进行训练,以使其具有良好的推广能力.实验结果表明神经网络的使用不仅扩大了距离的测量范围而且提高了测量精度.
Resumo:
A method using two prisms for measurement of small dynamic angles is proposed in which the measurement is based on a simple tangent equation and a phase-modulating interferometer with a laser diode to measure dynamic optical path differences with higher accuracy. Owing to the simple tangent equation, the symmetry requirement on the two prisms in the optical configuration is eliminated, and easy measurement of the separations between two parallel beams with a position-sensitive detector is achieved. Small-dynamic-angle measurements are experimentally demonstrated with high accuracy. (C) 2007 Society of Photo-Optical Instrumentation Engineers.
Resumo:
A parallel plate interferometer with a reflecting mirror for measuring angular displacement is proposed. A deflection angle of a beam caused by an angular displacement is amplified by use of a reflecting mirror to increase the optical path difference (OPD) in the plane-parallel plate, which provides high sensitivity of the phase measurement. Detection of light transmitted through the plane-parallel plate with a position sensitive detector (PSD) enables high accurate measurement of the initial angle of incidence to the plane-parallel plate with insensitivity to stray light. The improved parallel plate interferometer achieves a measurement repeatability of 10(-8) rad. (C) 2007 The Optical Society of Japan.
Resumo:
表面形貌干涉测量技术是一种高精度的非接触式测量技术,在工业生产和科学研究中具有广泛的应用。提出一种实时测量表面形貌的正弦相位调制干涉测量新技术。该技术用激光二极管作光源,用自制的高速图像传感器探测干涉信号,通过信号处理电路实时解相得到被测表面所对应的相位分布,实时分析相位获得物体表面形貌。该技术消除了光强和部分外界干扰的影响,提高了系统的测量精度。楔形光学平板表面形貌的测量结果表明,测量点为60×60个的情况下,测量时间小于8.2 ms,重复测量精度(RMS)为4.3 nm。
Resumo:
提出一种实时测量表面形貌的正弦相位调制半导体激光干涉仪。利用实时相位检测电路,从正弦相位调制干涉信号中解出被测量物体表面形貌的相位。在实验中,测量了楔形光学平板的表面形貌,对表面形貌上的60
Resumo:
提出一种基于正切关系和相位调制技术的动态小角度测量方法。使用双棱镜组成干涉测量臂引导两束平行光至分束棱镜处干涉,通过提取携带被测信息的干涉信号的相位实现动态的小角度测量。由于采用位置探测器(PSD)对测量臂中两平行光束的间距进行测量,简化了测量方程,消除了装置中双棱镜必须对称放置的要求。通过正弦地改变半导体激光器的注入电流在时域内实现对干涉信号的相位调制,形成准外差干涉测量模式,提高了光程差的测量精度。实验验证了该方法的可行性,并讨论了影响小角度测量精度的误差因素。研究结果表明,基于该方法的动态小角度的重
Resumo:
在激光二极管(LD)正弦相位调制(LD-SPM)干涉仪中,通过注入电流调制激光二极管波长的同时,光源输出的光强也被调制,成为测量误差的主要来源之一。提出一种新的消除激光二极管正弦相位调制干涉仪中光强调制影响的干涉仪,给出了具体的理论分析。该干涉仪采用全光纤结构,有效减小外界干扰对干涉测量的影响;采用容易实现的前置信号处理电路和实时相位检测器对干涉信号进行处理,消除了激光二极管光强调制产生的测量误差;同时实现了物体微小位移的高精度实时测量,测量的重复精度达到1 nm。实验结果与其他消除光强调制影响的方法测得
Resumo:
Coupling a single-mode laser diode with 200 mW to a single-mode fiber (SMF) through an orthonormal aspherical cylindrical lens and a GRIN lens for the intersatellite optical communication system is proposed and demonstrated. We experimentally studied how the coupling efficiency changes with the SMF's position displacement and axial angle variation, and obtained 80 mW output power at the end of the SMF, which shows that the coupling units have satisfied the designed request. (c) 2007 Elsevier GmbH. All rights reserved.
Resumo:
The measurement accuracy of a parallel-plate interferometer for angular displacement measurement is analyzed. The measurement accuracy of angular displacement is not only related to the accuracy of phase extraction, but also related to initial incident angle, refraction index and thickness of plane-parallel plate as well as wavelength's stability of laser diode, etc. Theoretical analysis and computer simulation show that the measurement error of the angular displacement bears a minimum value when choosing an optimal initial incident angle in a large range. These analytical results serve as a guide in practical measurement. In this interferometer, reducing the refraction index or increasing the thickness of the parallel plate can improve the measurement accuracy; and the relative error of the phase measurement is 3.0 x 10(-4) corresponding to 1 degrees C temperature variation. Based on these theoretical and experimental results, the measurement accuracy of the parallel-plate interferometer is up to an order of 10(-8) rad. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
As there exist some problems with the previous laser diode (LD) real-time microvibration measurement interferometers, such as low accuracy, correction before every use, etc., in this paper, we propose a new technique to realize the real-time microvibration measurement by using the LD sinusoidal phase-modulating interferometer, analyze the measurement theory and error, and simulate the measurement accuracy. This interferometer utilizes a circuit to process the interference signal in order to obtain the vibration frequency and amplitude of the detective signal, and a computer is not necessary in it. The influence of the varying light intensity and light path difference on the measurement result can be eliminated. This technique is real-time, convenient, fast, and can enhance the measurement accuracy too. Experiments show that the repeatable measurement accuracy is less than 3.37 nm, and this interferometer can be applied to real-time microvibration measurement of the MEMS. (C) 2007 Elsevier GmbH. All rights reserved.
Resumo:
Stable single-frequency and single-polarization distributed-feedback (DFB) fiber laser was realized by giving a pressure on the phase shift region of the fiber grating. The output wavelength of the DFB fiber laser is 1053 nm. When the pump power of 980 nm laser diode is 100 and 254 mW, the output power can reach 8.3 and 37.1 mW and the polarization extinction ratio was 26 and 20 dB, respectively. After chopped by Acousto-optic modulator (0.3 Hz), the pulse peak value variance is 4.65%(peak to peak) and 1.098% (RMS) for 31 min. (C) 2006 Elsevier Ltd. All rights reserved.
Resumo:
固体热容激光器(SSHCL)作为高功率固体激光器的一个重要发展方向,引起人们广泛关注。数值模拟激光介质板条在热容方式下工作的温度和应力分布是了解该类激光器工作特性的一种有效手段,采用平面应力近似法导出了半导体激光器抽运热容激光介质板的二维温度和应力分布公式,同时也对二维抽运光吸收密度、介质板温度分布和折射率变化进行了分析与讨论。数值计算的结果表明二维效应的温度分布和应力分布要比一维效应给出的分布更均匀。
Resumo:
由于a轴切割Nd∶YVO4晶体的非对称性,使得激光二极管(LD)端面抽运Nd∶YVO4固体激光器不同于Nd∶YAG激光器,输出的激光经常产生非对称结果。用有限元法分析激光二极管端面抽运a轴切割Nd∶YVO4固体激光器的晶体热效应,包括温度分布、内部应力和产生的形变。分析结果表明端面抽运a轴切割Nd∶YVO4晶体产生了椭球热透镜效应。从结构方面和抽运方面提出了热透镜非对称性的平衡方法,实验验证了方法的可行性。
Resumo:
设计并实现了一种放大纳秒激光脉冲的高稳定的激光二极管(LD)抽运Nd∶YLF再生放大器。为了获得高稳定的输出,再生放大器工作在饱和状态。此时,再生放大器输出稳定性最好,而且注入激光脉冲能量波动引起的输出激光脉冲波动被抑制。由于增益饱和效应,再生放大器输出脉冲出现时域波形失真,附加后缀脉冲能够减弱时域波形失真。放大器工作波长1053nm,工作频率1Hz。输入240pJ的3ns方波激光脉冲,输出激光脉冲能量4.2mJ,总增益大于107,不稳定度小于1%(均方根),方波扭曲1.33。为3ns方波激光脉冲引入其本身幅度0.75倍的后缀脉冲,输出激光脉冲方波扭曲由1.33降至1.17。
Resumo:
采用面泵浦的CAMIL结构,我们研究了970 nm泵浦的Yb:YAG/YAG复合陶瓷薄片激光器,获得了连续和调Q的激光输出。在连续运转情况下,获得了最高1.05 W的激光输出,中心波长为1031 nm,后腔输出镜透射率为2%。我们同时获得了声光调Q的脉冲输出,重复频率从1 kHz到30 kHz,脉宽分别从166 ns到700 ns。