587 resultados para Laparoscopic
Resumo:
We present a video of an ultrasound-guided laparoscopic surgical management of a large uterine scar isthmocele connected with the extra-amniotic space in early pregnancy. A case of a pregnant patient who was diagnosed with a large isthmocele connected with the extra-amniotic space on routine ultrasound at 8 weeks of gestational age is presented. The uterine defect was successfully sutured laparoscopically under ultrasound guidance. The pregnancy continued uneventfully, and a healthy baby was delivered via cesarean section at 38 weeks gestational age.
Resumo:
Herein is presented a technique for minimally invasive sentinel node mapping. The patient had apparently early stage endometrial cancer. Sentinel node mapping was performed using a hysteroscopic injection of indocyanine green followed by laparoscopic sentinel node detection via near-infrared fluorescence. This technique ensures delineation of lymphatic drainage from the tumor area, thus achieving accurate detection of sentinel nodes.
Resumo:
BACKGROUND Patient-to-image registration is a core process of image-guided surgery (IGS) systems. We present a novel registration approach for application in laparoscopic liver surgery, which reconstructs in real time an intraoperative volume of the underlying intrahepatic vessels through an ultrasound (US) sweep process. METHODS An existing IGS system for an open liver procedure was adapted, with suitable instrument tracking for laparoscopic equipment. Registration accuracy was evaluated on a realistic phantom by computing the target registration error (TRE) for 5 intrahepatic tumors. The registration work flow was evaluated by computing the time required for performing the registration. Additionally, a scheme for intraoperative accuracy assessment by visual overlay of the US image with preoperative image data was evaluated. RESULTS The proposed registration method achieved an average TRE of 7.2 mm in the left lobe and 9.7 mm in the right lobe. The average time required for performing the registration was 12 minutes. A positive correlation was found between the intraoperative accuracy assessment and the obtained TREs. CONCLUSIONS The registration accuracy of the proposed method is adequate for laparoscopic intrahepatic tumor targeting. The presented approach is feasible and fast and may, therefore, not be disruptive to the current surgical work flow.
Resumo:
Training and assessment paradigms for laparoscopic surgical skills are evolving from traditional mentor–trainee tutorship towards structured, more objective and safer programs. Accreditation of surgeons requires reaching a consensus on metrics and tasks used to assess surgeons’ psychomotor skills. Ongoing development of tracking systems and software solutions has allowed for the expansion of novel training and assessment means in laparoscopy. The current challenge is to adapt and include these systems within training programs, and to exploit their possibilities for evaluation purposes. This paper describes the state of the art in research on measuring and assessing psychomotor laparoscopic skills. It gives an overview on tracking systems as well as on metrics and advanced statistical and machine learning techniques employed for evaluation purposes. The later ones have a potential to be used as an aid in deciding on the surgical competence level, which is an important aspect when accreditation of the surgeons in particular, and patient safety in general, are considered. The prospective of these methods and tools make them complementary means for surgical assessment of motor skills, especially in the early stages of training. Successful examples such as the Fundamentals of Laparoscopic Surgery should help drive a paradigm change to structured curricula based on objective parameters. These may improve the accreditation of new surgeons, as well as optimize their already overloaded training schedules.
Resumo:
Automatic analysis of minimally invasive surgical (MIS) video has the potential to drive new solutions that alleviate existing needs for safer surgeries: reproducible training programs, objective and transparent assessment systems and navigation tools to assist surgeons and improve patient safety. As an unobtrusive, always available source of information in the operating room (OR), this research proposes the use of surgical video for extracting useful information during surgical operations. Methodology proposed includes tools' tracking algorithm and 3D reconstruction of the surgical field. The motivation for these solutions is the augmentation of the laparoscopic view in order to provide orientation aids, optimal surgical path visualization, or preoperative virtual models overlay
Resumo:
INTRODUCTION: The EVA (Endoscopic Video Analysis) tracking system a new tracking system for extracting motions of laparoscopic instruments based on non-obtrusive video tracking was developed. The feasibility of using EVA in laparoscopic settings has been tested in a box trainer setup. METHODS: EVA makes use of an algorithm that employs information of the laparoscopic instrument's shaft edges in the image, the instrument's insertion point, and the camera's optical centre to track the 3D position of the instrument tip. A validation study of EVA comprised a comparison of the measurements achieved with EVA and the TrEndo tracking system. To this end, 42 participants (16 novices, 22 residents, and 4 experts) were asked to perform a peg transfer task in a box trainer. Ten motion-based metrics were used to assess their performance. RESULTS: Construct validation of the EVA has been obtained for seven motion-based metrics. Concurrent validation revealed that there is a strong correlation between the results obtained by EVA and the TrEndo for metrics such as path length (p=0,97), average speed (p=0,94) or economy of volume (p=0,85), proving the viability of EVA. CONCLUSIONS: EVA has been successfully used in the training setup showing potential of endoscopic video analysis to assess laparoscopic psychomotor skills. The results encourage further implementation of video tracking in training setups and in image guided surgery.
Resumo:
INTRODUCTION: Motion metrics have become an important source of information when addressing the assessment of surgical expertise. However, their direct relationship with the different surgical skills has not been fully explored. The purpose of this study is to investigate the relevance of motion-related metrics in the evaluation processes of basic psychomotor laparoscopic skills, as well as their correlation with the different abilities sought to measure. METHODS: A framework for task definition and metric analysis is proposed. An explorative survey was first conducted with a board of experts to identify metrics to assess basic psychomotor skills. Based on the output of that survey, three novel tasks for surgical assessment were designed. Face and construct validation study was performed, with focus on motion-related metrics. Tasks were performed by 42 participants (16 novices, 22 residents and 4 experts). Movements of the laparoscopic instruments were registered with the TrEndo tracking system and analyzed. RESULTS: Time, path length and depth showed construct validity for all three tasks. Motion smoothness and idle time also showed validity for tasks involving bi-manual coordination and tasks requiring a more tactical approach respectively. Additionally, motion smoothness and average speed showed a high internal consistency, proving them to be the most task-independent of all the metrics analyzed. CONCLUSION: Motion metrics are complementary and valid for assessing basic psychomotor skills, and their relevance depends on the skill being evaluated. A larger clinical implementation, combined with quality performance information, will give more insight on the relevance of the results shown in this study.
Resumo:
Purpose: Surgical simulators are currently essential within any laparoscopic training program because they provide a low-stakes, reproducible and reliable environment to acquire basic skills. The purpose of this study is to determine the training learning curve based on different metrics corresponding to five tasks included in SINERGIA laparoscopic virtual reality simulator. Methods: Thirty medical students without surgical experience participated in the study. Five tasks of SINERGIA were included: Coordination, Navigation, Navigation and touch, Accurate grasping and Coordinated pulling. Each participant was trained in SINERGIA. This training consisted of eight sessions (R1–R8) of the five mentioned tasks and was carried out in two consecutive days with four sessions per day. A statistical analysis was made, and the results of R1, R4 and R8 were pair-wise compared with Wilcoxon signed-rank test. Significance is considered at P value <0.005. Results: In total, 84.38% of the metrics provided by SINERGIA and included in this study show significant differences when comparing R1 and R8. Metrics are mostly improved in the first session of training (75.00% when R1 and R4 are compared vs. 37.50% when R4 and R8 are compared). In tasks Coordination and Navigation and touch, all metrics are improved. On the other hand, Navigation just improves 60% of the analyzed metrics. Most learning curves show an improvement with better results in the fulfillment of the different tasks. Conclusions: Learning curves of metrics that assess the basic psychomotor laparoscopic skills acquired in SINERGIA virtual reality simulator show a faster learning rate during the first part of the training. Nevertheless, eight repetitions of the tasks are not enough to acquire all psychomotor skills that can be trained in SINERGIA. Therefore, and based on these results together with previous works, SINERGIA could be used as training tool with a properly designed training program.
Resumo:
Minimally invasive surgery is a highly demanding surgical approach regarding technical requirements for the surgeon, who must be trained in order to perform a safe surgical intervention. Traditional surgical education in minimally invasive surgery is commonly based on subjective criteria to quantify and evaluate surgical abilities, which could be potentially unsafe for the patient. Authors, surgeons and associations are increasingly demanding the development of more objective assessment tools that can accredit surgeons as technically competent. This paper describes the state of the art in objective assessment methods of surgical skills. It gives an overview on assessment systems based on structured checklists and rating scales, surgical simulators, and instrument motion analysis. As a future work, an objective and automatic assessment method of surgical skills should be standardized as a means towards proficiency-based curricula for training in laparoscopic surgery and its certification.
Resumo:
Laparoscopic instrument tracking systems are a key element in image-guided interventions, which requires high accuracy to be used in a real surgical scenario. In addition, these systems are a suitable option for objective assessment of laparoscopic technical skills based on instrument motion analysis. This study presents a new approach that improves the accuracy of a previously presented system, which applies an optical pose tracking system to laparoscopic practice. A design enhancement of the artificial markers placed on the laparoscopic instrument as well as an improvement of the calibration process are presented as a means to achieve more accurate results. A technical evaluation has been performed in order to compare the accuracy between the previous design and the new approach. Results show a remarkable improvement in the fluctuation error throughout the measurement platform. Moreover, the accumulated distance error and the inclination error have been improved. The tilt range covered by the system is the same for both approaches, from 90º to 7.5º. The relative position error is better for the new approach mainly at close distances to the camera system
Resumo:
Purpose: To compare assessment capabilities of a motion analysis tool against a validated checklist during laparoscopic training.
Resumo:
Background The aim of this study is to present face, content, and constructs validity of the endoscopic orthogonal video system (EndoViS) training system and determines its efficiency as a training and objective assessment tool of the surgeons’ psychomotor skills. Methods Thirty-five surgeons and medical students participated in this study: 11 medical students, 19 residents, and 5 experts. All participants performed four basic skill tasks using conventional laparoscopic instruments and EndoViS training system. Subsequently, participants filled out a questionnaire regarding the design, realism, overall functionality, and its capabilities to train hand–eye coordination and depth perception, rated on a 5-point Likert scale. Motion data of the instruments were obtained by means of two webcams built into a laparoscopic physical trainer. To identify the surgical instruments in the images, colored markers were placed in each instrument. Thirteen motion-related metrics were used to assess laparoscopic performance of the participants. Statistical analysis of performance was made between novice, intermediate, and expert groups. Internal consistency of all metrics was analyzed with Cronbach’s α test. Results Overall scores about features of the EndoViS system were positives. Participants agreed with the usefulness of tasks and the training capacities of EndoViS system (score >4). Results presented significant differences in the execution of three skill tasks performed by participants. Seven metrics showed construct validity for assessment of performance with high consistency levels. Conclusions EndoViS training system has been successfully validated. Results showed that EndoViS was able to differentiate between participants of varying laparoscopic experience. This simulator is a useful and effective tool to objectively assess laparoscopic psychomotor skills of the surgeons.
Resumo:
Objective: To compare tension-free open mesh hernioplasty under local anaesthetic with transabdominal preperitoneal laparoscopic hernia repair under general anaesthetic.
Resumo:
Background/Purpose: Several pull-through procedures are available for the surgical management of Hirschsprung's disease (HD) in children. The authors have adopted a laparoscopic approach since 1995, including laparoscopic Swenson procedure (LSw), both for one-stage primary and 2-stage secondary procedures. The aim of this study was to examine the role of LSw in children with HD in both primary and secondary procedures. Methods: From January 1995 to December 2001, 42 children with biopsy-proven HD underwent laparoscopic pull-through procedure for HD. This group included 29 children who underwent LSw, a detailed analysis of which forms the basis of this report. Results: Sixteen children underwent a single-stage neonatal LSw; the median weight of this group at the time of surgery was 3.2 kg and the median age was 5 days. Secondary LSw was performed in the remaining 13 children, which included 3 children with total colonic HD who underwent laparoscopic total colectomy and LSw. The median operating time was 105 minutes (range, 66 to 175 minutes). The median time to commence full diet was 48 hours (range, 24 to 86 hours), and median time to return to normal play and activity was 72 hours (range, 48 hours to 5 days). There was no difference in operating time between primary and secondary pull-through procedures. There were no intraoperative complications, and no patient required open conversion. Postoperative ileus was noted in 3 children and enterocolitis in 2. The median hospital stay was 4 days (range, 2 to 6 days). Follow-up was between 6 months to 7 years with a median follow-up of 2.2 years. At follow-up, 2 children required laparoscopic antegrade continence enema procedure. A satisfactory continence was noted in 15 of the 19 children who were older than 3 years at the time of last follow-up. Conclusions: LSw seems to be a suitable procedure for laparoscopic management of HD in children. LSw is safe and effective, both for primary and secondary type of pull-through procedures, with good short-term results.