903 resultados para Intraaortic Balloon Pump
Resumo:
Background. A sizable group of patients with symptomatic aortic stenosis (AS) can undergo neither surgical aortic valve replacement (AVR) nor transcatheter aortic valve implantation (TAVI) because of clinical contraindications. The aim of this study was to assess the potential role of balloon aortic valvuloplasty (BAV) as a “bridge-to-decision” in selected patients with severe AS and potentially reversible contraindications to definitive treatment. Methods. We retrospectively enrolled 645 patients who underwent first BAV at our Institution between July 2007 and December 2012. Of these, the 202 patients (31.2%) who underwent BAV as bridge-to-decision (BTD) requiring clinical re-evaluation represented our study population. BTD patients were further subdivided in 5 groups: low left ventricular ejection fraction; mitral regurgitation grade ≥3; frailty; hemodynamic instability; comorbidity. The main objective of the study was to evaluate how BAV influenced the final treatment strategy in the whole BTD group and in its single specific subgroups. Results. Mean logistic EuroSCORE was 23.5±15.3%, mean age was 81±7 years. Mean transaortic gradient decreased from 47±17 mmHg to 33±14 mmHg. Of the 193 patients with BTD-BAV who received a second heart team evaluation, 72.5% were finally deemed eligible for definitive treatment (25.4%for AVR; 47.2% for TAVI): respectively, 96.7% of patients with left ventricular ejection fraction recovery; 70.5% of patients with mitral regurgitation reduction; 75.7% of patients who underwent BAV in clinical hemodynamic instability; 69.2% of frail patients and 68% of patients who presented relevant comorbidities. 27.5% of the study population was deemed ineligible for definitive treatment and treated with standard therapy/repeated BAV. In-hospital mortality was 4.5%, cerebrovascular accident occurred in 1% and overall vascular complications were 4% (0.5% major; 3.5% minor). Conclusions. Balloon aortic valvuloplasty should be considered as bridge-to-decision in high-risk patients with severe aortic stenosis who cannot be immediate candidates for definitive percutaneous or surgical treatment.
Resumo:
The Swiss Federal Office of Public Health demanded a nationwide health technology assessment registry for cervical and lumbar total disc arthroplasty and for balloon kyphoplasty (BKP) to make a decision about reimbursement of these interventions.
Resumo:
Endovascular treatment is an increasingly used therapeutic option in patients with chronic atherosclerotic occlusive mesenteric disease. Purpose of this study was evaluation of patency and mortality in patients treated with visceral artery percutaneous transluminal angioplasty (PTA) or stenting including follow-up.
Resumo:
Diagnostic coronary balloon occlusion (CBO) is mandatory for collateral function assessment, during angioscopy and optical coherence imaging, and when using certain coronary protection devices against emboli. Thus far, the safety of diagnostic CBO regarding procedural and long-term complications in normal coronary arteries has not been studied. In 316 patients, diagnostic CBO was performed for collateral function measurement in 426 angiographically normal vessels. The angioplasty balloon was inflated for 60 to 120 seconds using inflation pressures of 1 to 3 atm, followed by control angiography during and after CBO. Patients were divided into groups with entirely normal (n = 133) and partially normal (n = 183) vessels. Primary end points were procedural and long-term complications. De novo stenosis development was assessed by quantitative coronary angiography in 35% of the patients. Secondary end points were cardiac events at 5 years of follow-up. Procedural complications occurred in 1 patient (0.2%). In 150 repeat angiographic procedures in 92 patients (follow-up duration 10 +/- 15 months), quantitative coronary angiography revealed no difference in percentage diameter narrowing between baseline and follow-up (4.1% vs 3.9%, p = 0.69). During follow-up periods of 14 and 72 months, respectively, a new stenotic lesion was detected in 1 patient in each group (1.3%). Major cardiac events and percutaneous coronary intervention for stable angina were less frequent in the group with entirely normal than with partially normal vessels (0.8% vs 5.5%, p = 0.02, and 0.8% vs 18%, p <0.0001). In conclusion, low-inflation pressure diagnostic CBO in angiographically normal coronary arteries bears a minimal risk for procedural and long-term complications and can therefore be regarded as a safe procedure.
Resumo:
To investigate the efficacy of sensor-augmented pump therapy vs. multiple daily injection therapy in patients with suboptimally controlled Type 1 diabetes.
Resumo:
Balloon sinuplasty is a tool that is used to treat selected patients with paranasal sinus pathologies. No studies have investigated the aetiology of failed access to the frontal sinus. The aim of our study was to specify the intraoperative technical failure rate and to analyse the aetiology of the failed access to predict potential technical difficulties before surgery. We retrospectively analysed the charts of patients who underwent balloon sinuplasty from November 2007 to July 2010 at three different ENT-Centres. CT-analysis of the patients with failed access was performed. Of the 104 frontal sinuses, dilation of 12 (12%) sinuses failed. The anatomy of all failed cases revealed variations in the frontal recess (frontoethmoidal-cell, frontal-bulla-cell or agger-nasi-cell) or osteoneogenesis. In one patient, a lymphoma was overlooked during a balloon only procedure. The lymphoma was diagnosed 6 months later with a biopsy during functional endoscopic sinus surgery. In complex anatomical situations of the frontal recess, balloon sinuplasty may be challenging or impossible. In these situations, it is essential to have knowledge of classical functional endoscopic sinus surgery of the frontal recess area. The drawbacks of not including a histopathologic exam should be considered in balloon only procedures.
Resumo:
Rotary blood pumps (RBPs) running at a constant speed are routinely used for the mechanical support of the heart in various clinical applications, from short-term use in heart-lung machines to long-term support of a failing heart. Their operating range is delineated by suction and regurgitation events, leaving limited control on the cardiac workload. This study investigates whether different ratios of systolic/diastolic support are advantageous over a constant-speed operation.
Resumo:
The study investigated the efficacy and safety of a balloon expandable, sirolimus-eluting stent (SES) in patients with symptomatic infrapopliteal arterial disease.
Resumo:
The prognostic relevance of quantitative an intracoronary occlusive electrocardiographic (ECG) ST-segment shift and its determinants have not been investigated in humans. In 765 patients with chronic stable coronary artery disease, the following simultaneous quantitative measurements were obtained during a 1-minute coronary balloon occlusion: intracoronary ECG ST-segment shift (recorded by angioplasty guidewire), mean aortic pressure, mean distal coronary pressure, and mean central venous pressure (CVP). Collateral flow index (CFI) was calculated as follows: (mean distal coronary pressure minus CVP)/(mean aortic pressure minus CVP). During an average follow-up duration of 50 ± 34 months, the cumulative mortality rate from all causes was significantly lower in the group with an ST-segment shift <0.1 mV (n = 89) than in the group with an ST-segment shift ≥0.1 mV (n = 676, p = 0.0211). Factors independently related to intracoronary occlusive ECG ST-segment shift <0.1 mV (r(2) = 0.189, p <0.0001) were high CFI (p <0.0001), intracoronary occlusive RR interval (p = 0.0467), right coronary artery as the ischemic region (p <0.0001), and absence of arterial hypertension (p = 0.0132). "High" CFI according to receiver operating characteristics analysis was ≥0.217 (area under receiver operating characteristics curve 0.647, p <0.0001). In conclusion, absence of ECG ST-segment shift during brief coronary occlusion in patients with chronic coronary artery disease conveys a decreased mortality and is directly influenced by a well-developed collateral supply to the right versus left coronary ischemic region and by the absence of systemic hypertension in a patient's history.
Resumo:
A prototype vortex-driven air lift pump was developed and experimentally evaluated. It was designed to be easily manufactured and scalable for arbitrary riser diameters. The model tested fit in a 2 inch diameter riser with six air injection nozzles through which airwas injected helically around the perimeter of the riser at an angle of 70º from pure tangential injection. The pump was intended to transport both water and sediment over a large range of submergence ratios. A test apparatus was designed to be able to simulate deep water or oceanic environments. The resulting test setup had a finite reservoir; over the course of a test, the submergence ratio varied from 0.48 to 0.39. For air injection pressures ranging from 10 to 60 psig and for air flow rates of 6 to 15 scfm, the induced water discharge flow rates varied only slightly, due to the limited range of available submergence ratios. The anticipated simulation of deep water environment, with a corresponding equivalent increase in thesubmergence ratio, proved unattainable. The pump prototype successfully transported both water and sediment (sand). Thepercent volume yield of the sediment was in an acceptable range. The pump design has been subsequently used successfully in a 4 inch configuration in a follow-on project. A computer program was written in Matlab to simulate the pump characteristics. The program output water pressures at the location of air injection which were physicallycompatible with the experimental data.
Resumo:
Vascular surgical training currently has to cope with various challenges, including restrictions on work hours, significant reduction of open surgical training cases in many countries, an increasing diversity of open and endovascular procedures, and distinct expectations by trainees. Even more important, patients and the public no longer accept a "learning by doing" training philosophy that leaves the learning curve on the patient's side. The Vascular International (VI) Foundation and School aims to overcome these obstacles by training conventional vascular and endovascular techniques before they are applied on patients. To achieve largely realistic training conditions, lifelike pulsatile models with exchangeable synthetic arterial inlays were created to practice carotid endarterectomy and patch plasty, open abdominal aortic aneurysm surgery, and peripheral bypass surgery, as well as for endovascular procedures, including endovascular aneurysm repair, thoracic endovascular aortic repair, peripheral balloon dilatation, and stenting. All models are equipped with a small pressure pump inside to create pulsatile flow conditions with variable peak pressures of ~90 mm Hg. The VI course schedule consists of a series of 2-hour modules teaching different open or endovascular procedures step-by-step in a standardized fashion. Trainees practice in pairs with continuous supervision and intensive advice provided by highly experienced vascular surgical trainers (trainer-to-trainee ratio is 1:4). Several evaluations of these courses show that tutor-assisted training on lifelike models in an educational-centered and motivated environment is associated with a significant increase of general and specific vascular surgical technical competence within a short period of time. Future studies should evaluate whether these benefits positively influence the future learning curve of vascular surgical trainees and clarify to what extent sophisticated models are useful to assess the level of technical skills of vascular surgical residents at national or international board examinations. This article gives an overview of our experiences of >20 years of practical training of beginners and advanced vascular surgeons using lifelike pulsatile vascular surgical training models.
Resumo:
Purpose: Mismatches between pump output and venous return in a continuous-flow ventricular assist device may elicit episodes of ventricular suction. This research describes a series of in vitro experiments to characterize the operating conditions under which the EVAHEART centrifugal blood pump (Sun Medical Technology Research Corp., Nagano, Japan) can be operated with minimal concern regarding left ventricular (LV) suction. Methods: The pump was interposed into a pneumatically driven pulsatile mock circulatory system (MCS) in the ventricular apex to aorta configuration. Under varying conditions of preload, afterload, and systolic pressure, the speed of the pump was increased step-wise until suction was observed. Identification of suction was based on pump inlet pressure. Results: In the case of reduced LV systolic pressure, reduced preload (=10 mmHg), and afterload (=60 mmHg), suction was observed for speeds =2,200 rpm. However, suction did not occur at any speed (up to a maximum speed of 2,400 rpm) when preload was kept within 10-14 mmHg and afterload =80 mmHg. Although in vitro experiments cannot replace in vivo models, the results indicated that ventricular suction can be avoided if sufficient preload and afterload are maintained. Conclusion: Conditions of hypovolemia and/or hypotension may increase the risk of suction at the highest speeds, irrespective of the native ventricular systolic pressure. However, in vitro guidelines are not directly transferrable to the clinical situation; therefore, patient-specific evaluation is recommended, which can be aided by ultrasonography at various points in the course of support.