998 resultados para Intestinal surgery
Resumo:
The use of thermodilution and other methods of monitoring in dogs during surgery and critical care was evaluated. Six Greyhounds were anaesthetised and then instrumented by placing a thermodilution catheter into the pulmonary artery via the jugular vein. A catheter in the dorsal pedal artery also permitted direct measurement of arterial pressures. Core body temperature (degreesC) and central venous pressure (mmHg) were measured, while cardiac output (mL/min/kg) and mean arterial pressure (mmHg) were calculated. A mid-line surgical incision was performed and the physiological parameters were monitored for a total of two hours. All physiological parameters generally declined, although significant increases (P<0.05) were noted for cardiac output following surgical incision. Central venous pressure was maintained at approximately 0mmHg by controlling an infusion of sterile saline. Core body temperature decreased from 37.1+/-0.6degreesC (once instrumented) to 36.6+/-0.60degreesC (at the end of the study), despite warming using heating pads. Physiological parameters indicative of patient viability will generally decline during surgery without intervention. This study describes an approach that can be undertaken in veterinary hospitals to accurately monitor vital signs in surgical and critical care patients.
Resumo:
A transitory increase in blood pressure (BP) is observed following upper airway surgery for obstructive sleep apnea syndrome but the mechanisms implicated are not yet well understood. The objective of the present study was to evaluate changes in BP and heart rate (HR) and putative factors after uvulopalatopharyngoplasty and septoplasty in normotensive snorers. Patients (N = 10) were instrumented for 24-h ambulatory BP monitoring, nocturnal respiratory monitoring and urinary catecholamine level evaluation one day before surgery and on the day of surgery. The influence of postsurgery pain was prevented by analgesic therapy as confirmed using a visual analog scale of pain. Compared with preoperative values, there was a significant (P < 0.05) increase in nighttime but not daytime systolic BP (119 ± 5 vs 107 ± 3 mmHg), diastolic BP (72 ± 4 vs 67 ± 2 mmHg), HR (67 ± 4 vs 57 ± 2 bpm), respiratory disturbance index (RDI) characterized by apnea-hypopnea (30 ± 10 vs 13 ± 4 events/h of sleep) and norepinephrine levels (22.0 ± 4.7 vs 11.0 ± 1.3 µg l-1 12 h-1) after surgery. A positive correlation was found between individual variations of BP and individual variations of RDI (r = 0.81, P < 0.01) but not between BP or RDI and catecholamines. The visual analog scale of pain showed similar stress levels on the day before and after surgery (6.0 ± 0.8 vs 5.0 ± 0.9 cm, respectively). These data strongly suggest that the cardiovascular changes observed in patients who underwent uvulopalatopharyngoplasty and septoplasty were due to the increased postoperative RDI.
Resumo:
Os neuropeptídeos são neurotransmissores relevantes na fisiologia nasal e o conhecimento crescente acerca de seu papel na fisiopatologia de doenças nasais abre novas perspectivas. A sua investigação na mucosa nasal humana baseia-se em grande parte em marcação imunológica, método complexo e sujeito a inúmeros fatores de erro. Com o intuito de viabilizar este tipo de pesquisa em nosso meio, um método de imunofluorescência para peptídeo intestinal vasoativo (VIP) na mucosa nasal humana é proposto e avaliado. FORMA DE ESTUDO: Coorte transversal. MATERIAL E MÉTODO: Oito pacientes submetidos a cirurgia funcional do nariz têm um fragmento de mucosa coletado da concha inferior. O tecido foi fixado em solução de Zamboni (paraformaldeído 4% tamponado e ácido pícrico 0,4%), congelado em nitrogênio líquido e armazenado. Cortes de 14 µm foram realizados e submetidos à reação de imunofluorescência para VIP (Península Laboratories). As imagens microscópicas foram documentadas em fotografia convencional. A especificidade, sensibilidade e reprodutibilidade de execução foram avaliadas. A reprodutibilidade de interpretação de resultados foi avaliada através da comparação de graus de marcação (0 a 4) atribuídos às fotos por seis observadores. RESULTADOS: Os resultados mostraram ser o método suficientemente específico, sensível, além de reprodutível em sua execução. A interpretação de resultados mostrou depender do perfeito esclarecimento do observador no julgamento das imagens de imunofluorescência, mas mostrou uniformidade. CONCLUSÃO: O método proposto foi considerado útil na pesquisa de neuropeptídeos na mucosa nasal humana.
Resumo:
Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.
Resumo:
Laparoscopy is a surgical procedure on which operations in the abdomen are performed through small incisions using several specialized instruments. The laparoscopic surgery success greatly depends on surgeon skills and training. To achieve these technical high-standards, different apprenticeship methods have been developed, many based on in vivo training, an approach that involves high costs and complex setup procedures. This paper explores Virtual Reality (VR) simulation as an alternative for novice surgeons training. Even though several simulators are available on the market claiming successful training experiences, their use is extremely limited due to the economic costs involved. In this work, we present a low-cost laparoscopy simulator able to monitor and assist the trainee’s surgical movements. The developed prototype consists of a set of inexpensive sensors, namely an accelerometer, a gyroscope, a magnetometer and a flex sensor, attached to specific laparoscopic instruments. Our approach allows repeated assisted training of an exercise, without time constraints or additional costs, since no human artificial model is needed. A case study of our simulator applied to instrument manipulation practice (hand-eye coordination) is also presented.
Resumo:
Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.
Resumo:
Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.
Resumo:
Laparoscopic surgery (LS) has revolutionized traditional surgical techniques introducing minimally invasive procedures for diagnosis and local therapies. LSs have undeniable advantages, such as small patient incisions, reduced postoperative pain and faster recovery. On the other hand, restricted vision of the anatomical target, difficult handling of the surgical instruments, restricted mobility inside the human body, need of dexterity to hand-eye coordination and inadequate and non-ergonomic surgical instruments may restrict LS only to more specialized surgeons. To overcome the referred limitations, this work presents a new robotic surgical handheld system – the EndoRobot. The EndoRobot was designed to be used in clinical practice or even as a surgical simulator. It integrates an electromechanical system with 3 degrees of freedom. Each degree can be manipulated independently and combined with different levels of sensitivity allowing fast and slow movements. As other features, the EndoRobot has battery power or external power supply, enables the use of bipolar radiofrequency to prevent bleeding while cutting and allows plug-and-play of the laparoscopic forceps for rapid exchange. As a surgical simulator, the system was also instrumented to measure and transmit, in real time, its position and orientation for a training software able to monitor and assist the trainee’s surgical movements.
Resumo:
Foram estudados 10 doentes, portadores de anemia ancilostomótica e de grande parasitose. Foram determinados alguns parâmetros hematológicos como dosagem de hemoglobina, contagem de hemácias, hematócrito, volume corpuscular médio, hemoglobina corpuscular média, ferro sérico e siderofilina. Foram estudados o volume da perda de sangue intestinal, o ferro perdido nesta hemorragia e eliminado nas fezes, e o ferro reaborvido da hemorragia intestinal. Conclui-se que a reabsorção do ferro da hemoglobina por dia no tubo digestivo é de suma importância no retardamento da instalação da anemia ferropriva, causada pela parasitose ancilostomótica.
Resumo:
During the second half of 1986 the impact of the improvement of water supply and excreta disposal facilities on diarrheal diseases and intestinal parasitosis was studied in 254 children up to six years of age from two favelas (shanty towns) of Belo Horizonte, Brazil. The estimated incidence of diarrhea was 6.2 episodes/child year and the estimated period prevalence reached 31.0 episode days/ child/ year. The point prevalence of parasitosis was 70.7% (Ascaris lumbricoides: 55.4%, Trichuris trichiura: 19.6%, Giardia lamblia: 17.9%). The estimated prevalence of diarrhea decreased with improvement of water supply and sanitation facilities to 45% and 44% respectively, but no statistically significant impact was observed in the case of parasitosis. School education and weaning practice were found to be other important determinants of diarrhea.
Resumo:
The natural distribution of thermotolerant Campylobacter sp. in dogs (150 stray animals and 64 pets) was studied. Campylobacters were more frequently isolated (p<0.01) from stray dogs (51.3%) rather than from pet dogs (21.9%). All the biotypes described by Lior for C. jejuni and C. coli were found among stray animals, whereas only C. jejuni biotypes I and II and C. coli biotype II were found among pet dogs. The need for more studies related to the role of environmental sanitary conditions in the spreading of Campylobacter species is noted.
Resumo:
A sub adult Caretta caretta was found on the 23rd August, 2014 ca. 16 nautical miles south off S. Miguel Island, Azores (Northeast Atlantic), with a large pelagic trawl hook inside its mouth. The individual was kept in a basin of sea water and sent by boat to Terceira Island following instructions by the Azores Regional Government via the Environmental Authority in order to be examined by the author and, if possible, undergo the necessary hook removal procedures. In this note, we describe the surgical procedures and how the turtle was evaluated both pre- and post-surgery.
Resumo:
O objetivo do estudo foi estimar as freqüências de tuberculose e parasitoses intestinais na em comunidades indígenas da localidade de Iauareté (AM), em 2001. Estudo transversal (n=333) visando à obtenção de dados demográficos e amostras biológicas para exames de escarro e fezes. Dentre os 43 sintomáticos respiratórios, seis foram positivos na pesquisa de bacilos álcool-ácido resistentes no escarro. As parasitoses intestinais apresentaram freqüência significativamente maior entre a população Hüpda do que entre os índios que habitam os demais bairros (37,5% vs. 19,3% para Ascaris lumbricoides, 32,4% vs. 16,3% para Trichuris trichiura, 75% vs. 19,3% para ancilostomídeos, 75% vs. 35,4% para Entamoeba histolyticaD dispar e 33,3% vs. 10,7% para Giardia lamblia). Conclui-se que a tuberculose e o parasitismo intestinal são freqüentes nessas comunidades, exigindo medidas de controle e melhorias na assistência à saúde.