925 resultados para Integrated Library System
Resumo:
The fabrication of heavy-duty printer heads involves a great deal of grinding work. Previously in the printer manufacturing industry, four grinding procedures were manually conducted in four grinding machines, respectively. The productivity of the whole grinding process was low due to the long loading time. Also, the machine floor space occupation was large because of the four separate grinding machines. The manual operation also caused inconsistent quality. This paper reports the system and process development of a highly integrated and automated high-speed grinding system for printer heads. The developed system, which is believed to be the first of its kind, not only produces printer heads of consistently good quality, but also significantly reduces the cycle time and machine floor space occupation.
Resumo:
The integrated control of nitrate recirculation and external carbon addition in a predenitrification biological wastewater treatment system is studied. The proposed control structure consists of four feedback control loops, which manipulate the nitrate recirculation and the carbon dosage flows in a highly coordinated manner such that the consumption of external carbon is minimised while the nitrate discharge limits (based on both grab and composite samples) are met. The control system requires the measurement of the nitrate concentrations at the end of both the anoxic and the aerobic zones. Distinct from ordinary control systems, which typically minimise the variation in the controlled variables, the proposed control system essentially maximises the diurnal variation of the effluent nitrate concentration and through this maximises the use of influent COD for denitrification, thus minimising the requirement for external carbon source. Simulation studies using a commonly accepted simulation benchmark show that the controlled system consistently achieves the designated effluent quality with minimum costs.
Resumo:
In many plant and animal bacterial pathogens, the Type III secretion system (TTSS) that directly translocates effector proteins into the eukaryotic host cells is essential for the development of disease. In all species studied, the transcription of the TTSS and most of its effector substrates is tightly regulated by a succession of consecutively activated regulators. However, the whole genetic programme driven by these regulatory cascades is still unknown, especially in bacterial plant pathogens. Here, we have characterised the programme triggered by HrpG, a host-responsive regulator of the TTSS activation cascade in the plant pathogen Ralstonia solanacearum. We show through genome-wide expression analysis that, in addition to the TTSS, HrpG controls the expression of a previously undescribed TTSS-independent pathway that includes a number of other virulence determinants and genes likely involved in adaptation to life in the host. Functional studies revealed that this second pathway co-ordinates the bacterial production of plant cell wall-degrading enzymes, exopolysaccharide, and the phytohormones ethylene and auxin. We provide experimental evidence that these activities contribute to pathogenicity. We also show that the ethylene produced by R. solanacearum is able to modulate the expression of host genes and can therefore interfere with the signalling of plant defence responses. These results provide a new, integrated view of plant bacterial pathogenicity, where a common regulator activates synchronously upon infection the TTSS, other virulence determinants and a number of adaptive functions, which act co-operatively to cause disease.
Resumo:
Agrobacterium VirB2 pilin is required for assembly of the VirB/VirD4 type IV secretion system (T4SS). The propilin is processed by signal sequence cleavage and covalent linkage of the N and C termini, and the cyclized pilin integrates into the inner membrane (IM) as a pool for assembly of the secretion channel and T pilus. Here, by use of the substituted cysteine accessibility method (SCAM), we defined the VirB2 IM topology and then identified distinct contributions of the T4SS ATPase subunits to the pilin structural organization. Labeling patterns of Cys-substituted pilins exposed to the membrane-impermeative, thiol-reactive reagent 3-(N-maleimidopropionyl)biocytin (MPB) supported a topology model in which two hydrophobic stretches comprise transmembrane domains, an intervening hydrophilic loop (residues 90 to 94) is cytoplasmic, and the hydrophilic N and C termini joined at residues 48 and 121 form a periplasmic loop. Interestingly, the VirB4 ATPase, but not a Walker A nucleoside triphosphate (NTP) binding motif mutant, induced (i) MPB labeling of Cys94, a residue that in the absence of the ATPase is located in the cytoplasmic loop, and (ii) release of pilin from the IM upon osmotic shock. These findings, coupled with evidence for VirB2-VirB4 complex formation by coimmunoprecipitation, support a model in which VirB4 functions as a dislocation motor to extract pilins from the IM during T4SS biogenesis. The VirB11 ATPase functioned together with VirB4 to induce a structural change in the pilin that was detectable by MPB labeling, suggestive of a role for VirB11 as a modulator of VirB4 dislocase activity.
Resumo:
A patient classification system was developed integrating a patient acuity instrument with a computerized nursing distribution method based on a linear programming model. The system was designed for real-time measurement of patient acuity (workload) and allocation of nursing personnel to optimize the utilization of resources.^ The acuity instrument was a prototype tool with eight categories of patients defined by patient severity and nursing intensity parameters. From this tool, the demand for nursing care was defined in patient points with one point equal to one hour of RN time. Validity and reliability of the instrument was determined as follows: (1) Content validity by a panel of expert nurses; (2) predictive validity through a paired t-test analysis of preshift and postshift categorization of patients; (3) initial reliability by a one month pilot of the instrument in a practice setting; and (4) interrater reliability by the Kappa statistic.^ The nursing distribution system was a linear programming model using a branch and bound technique for obtaining integer solutions. The objective function was to minimize the total number of nursing personnel used by optimally assigning the staff to meet the acuity needs of the units. A penalty weight was used as a coefficient of the objective function variables to define priorities for allocation of staff.^ The demand constraints were requirements to meet the total acuity points needed for each unit and to have a minimum number of RNs on each unit. Supply constraints were: (1) total availability of each type of staff and the value of that staff member (value was determined relative to that type of staff's ability to perform the job function of an RN (i.e., value for eight hours RN = 8 points, LVN = 6 points); (2) number of personnel available for floating between units.^ The capability of the model to assign staff quantitatively and qualitatively equal to the manual method was established by a thirty day comparison. Sensitivity testing demonstrated appropriate adjustment of the optimal solution to changes in penalty coefficients in the objective function and to acuity totals in the demand constraints.^ Further investigation of the model documented: correct adjustment of assignments in response to staff value changes; and cost minimization by an addition of a dollar coefficient to the objective function. ^
Resumo:
We present a simulator of a hydropower company’s view of its scheme, and its broader market and network context, which has been developed to evaluate advanced displays for control room operations. Although simplified, the simulator captures all the main aspects of scheme operations. The simulator allows controlled studies to be performed that test the effectiveness of current vs advanced display concepts under normal vs unexpected operating conditions that can be scripted into the simulator.
Resumo:
The MARS (Media Asset Retrieval System) Project is a collaboration between public broadcasters, libraries and schools in the Puget Sound region to assess the needs of their constituents and pool resources to develop solutions to meet those needs. The Project’s ultimate goal is to create a digital online resource that will provide access to content produced by public broadcasters and libraries. The MARS Project is funded by a grant from the Corporation for Public Broadcasting (CPB) Television Future Fund. Convergence ConsortiumThe Convergence Consortium is a model for community collaboration, including representatives from public broadcasting, libraries and schools in the Puget Sound region. They meet regularly to consider collaborative efforts that will be mutually beneficial to their institutions and constituents. Specifically, the archives of public broadcasters have been identified as significant resources that can be accessed through libraries and used by schools, and integrated with text and photographic archives from other partners.Using the work-centered framework, we collected data through interviews with nine engineers and observation of their searching while they performed their regular, job-related searches on the Web. The framework was used to analyze the data on two levels: 1) the activities and organizational relationships and constrains of work domains, and 2) users’ cognitive and social activities and their subjective preferences during searching.
Resumo:
Effluents originated in cellulose pulp manufacturing processes are usually toxic and recalcitrant, specially the bleaching effluents, which exhibit high contents of aromatic compounds (e.g. residual lignin derivates). Although biological processes are normally used, their efficiency for the removal of toxic lignin derivates is low. The toxicity and recalcitrance of a bleached Kraft pulp mill were assessed through bioassays and ultraviolet absorption measurements, i.e. acid soluble lignin (ASL), UV(280), and specific ultraviolet absorption (SUVA), before and after treatment by an integrated system comprised of an anaerobic packed-bed bioreactor and oxidation step with ozone. Furthermore, adsorbable organic halides (AOX) were measured. The results demonstrated not only that the toxic recalcitrant compounds can be removed successfully using integrated system, but also the ultraviolet absorption measurements can be an interesting control-parameter in a wastewater treatment.
Resumo:
The success in the adoption of peach integrated production (IP) was evaluated in small orchards of the Parana State. The importance of specific technical accompaniment; points of strangulating in adoption of technology and the classification of the areas to IP conformity were evaluated. The seasons 2005/2006 (without IP orientation) and 2006/2007 (with IP orientation) were compared considering 20 producers who were oriented monthly to attend the minimum requisites. The incidence of peach rust (Tranzschelia discolor) and of brown rot (Monilinia fructicola) in full bloom was evaluated in 2006/2007 and 2007/2008 seasons, as biological parameters to accompany the efficiency of system adoption. After the technical accompaniment in 2007/2008 season, the software APOIA-Novo Rural-PI (APOIA-PI) was applied to measure the conformity to IP in peach orchards. The conformity index of each orchard was compared to the minimum requisite to classify as IP (0.7). The major difficulties in register of field book were: pests monitoring; collect of climate data and the harvest evaluation. The technical accompaniment increased in 60% the conformity in use of field book. In 2007/2008 season, the brown rot incidence increased in some areas, caused by not following IP recommendations. The inadequate management caused the increment in pathogen inoculum, promoting the disease development in peach orchards. The APOIA-PI classified two orchards as good agricultural practices (GAP) (0.7 <= conformity index >= 0.4), two as integrated production (IP) (>= 0.7) and the other orchards had conformity index lower than 0.4.
Resumo:
SETTING: Hlabisa health district, South Africa. OBJECTIVE: To describe the integration of a vertical tuberculosis control programme into an emerging 'horizontal' district health system, within the context of health sector reform. DESIGN: Descriptive account of the process of integration of the programme into the health system. RESULTS: A highly 'vertical' system of delivering tuberculosis treatment (with poor programme outcomes) was converted into a (horizontal' team, integrated within the district health system, that used available resources such as village clinics and community health workers, with improved programme outcomes. CONCLUSIONS: In some settings at least, integration of tuberculosis 'programmes' into the district health system as tuberculosis 'teams' is feasible, and may produce highly cost-effective outcomes.