896 resultados para Initial stresses


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently a fingering morphology, resembling the hydrodynamic Saffman-Taylor instability, was identified in the quasi-two-dimensional electrodeposition of copper. We present here measurements of the dispersion relation of the growing front. The instability is accompanied by gravity-driven convection rolls at the electrodes, which are examined using particle image velocimetry. While at the anode the theory presented by Chazalviel et al. [J. Electroanal. Chem. 407, 61 (1996)] describes the convection roll, the flow field at the cathode is more complicated because of the growing deposit. In particular, the analysis of the orientation of the velocity vectors reveals some lag of the development of the convection roll compared to the finger envelope.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to compare the relative efficiency of initial selection and genetic parameter estimation, using augmented blocks design (ABD), augmented blocks twice replicated design (DABD) and group of randomised block design experiments with common treatments (ERBCT), by simulations, considering fixed effect model and mixed model with regular treatment effects as random. For the simulations, eight different conditions (scenarios) were considered. From the 600 simulations in each scenario, the mean percentage selection coincidence, the Pearsons´s correlation estimates between adjusted means for the fixed effects model, and the heritability estimates for the mixed model were evaluated. DABD and ERBCT were very similar in their comparisons and slightly superior to ABD. Considering the initial stages of selection in a plant breeding program, ABD is a good alternative for selecting superior genotypes, although none of the designs had been effective to estimate heritability in all the different scenarios evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Visualization of coronary blood flow in the right and left coronary system in volunteers and patients by means of a modified inversion-prepared bright-blood coronary magnetic resonance angiography (cMRA) sequence. MATERIALS AND METHODS: cMRA was performed in 14 healthy volunteers and 19 patients on a 1.5 Tesla MR system using a free-breathing 3D balanced turbo field echo (b-TFE) sequence with radial k-space sampling. For magnetization preparation a slab selective and a 2D selective inversion pulse were used for the right and left coronary system, respectively. cMRA images were evaluated in terms of clinically relevant stenoses (< 50 %) and compared to conventional catheter angiography. Signal was measured in the coronary arteries (coro), the aorta (ao) and in the epicardial fat (fat) to determine SNR and CNR. In addition, maximal visible vessel length, and vessel border definition were analyzed. RESULTS: The use of a selective inversion pre-pulse allowed direct visualization of the coronary blood flow in the right and left coronary system. The measured SNR and CNR, vessel length, and vessel sharpness in volunteers (SNR coro: 28.3 +/- 5.0; SNR ao: 37.6 +/- 8.4; CNR coro-fat: 25.3 +/- 4.5; LAD: 128.0 cm +/- 8.8; RCA: 74.6 cm +/- 12.4; Sharpness: 66.6 % +/- 4.8) were slightly increased compared to those in patients (SNR coro: 24.1 +/- 3.8; SNR ao: 33.8 +/- 11.4; CNR coro-fat: 19.9 +/- 3.3; LAD: 112.5 cm +/- 13.8; RCA: 69.6 cm +/- 16.6; Sharpness: 58.9 % +/- 7.9; n.s.). In the patient study the assessment of 42 coronary segments lead to correct identification of 10 clinically relevant stenoses. CONCLUSION: The modification of a previously published inversion-prepared cMRA sequence allowed direct visualization of the coronary blood flow in the right as well as in the left coronary system. In addition, this sequence proved to be highly sensitive regarding the assessment of clinically relevant stenotic lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To examine the efficacy and safety of repeat deep sclerectomy (DS) versus Baerveldt shunt (BS) implantation as second line surgery following failed primary DS. Methods: Fifty one patients were prospectively recruited to undergo BS implantation following failed DS and 51 patients underwent repeat DS, for which data was collected retrospectively. All eyes had at least one failed DS. Surgical success was defined as IOP≤21mmHg and 20% reduction in IOP from baseline. Success rates, number of glaucoma medications (GMs), IOP, and complication rates were compared between the two groups at year 1, post-operatively. Results: Mean age, sex and the proportion of glaucoma subtypes were similar between groups. Preoperatively IOP was significantly lower in DS group vs BS group (18.8mmHg vs 23.8mmHg, p<0.01, two sample t-test). Postoperatively IOP was significantly higher in DS group than BS group (14.6mmHg vs 12.0mmHg, p<0.01, two-sample t-test). In the DS group, 47% of eyes did not achieve 20% reduction in IOP from baseline, as a result the success rates were significantly lower in eyes with DS (51%) than in eyes with BS (88%) (p=0.02, log-rank test). Preoperatively the number of GMs used in DS and BS groups were similar (2.2 vs 2.7 p=0.02, two sample t-test). Postoperatively there remained no significant difference in GMs between groups (0.9 vs 1.1, p= 0.58, two sample t-test). Complication rates were similar between the two groups (12% vs 10%). Conclusions: Baerveldt tube implantation was more effective in lowering IOP than repeat deep sclerectomy in eyes with failed primary DS, at year one. Complications were minor and infrequent in both groups

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a phenomenon occurring in field-responsive suspensions: shear-induced anomalous stresses. Competition between a rotating field and a shear flow originates a multiplicity of anomalous stress behaviors in suspensions of bound dimers constituted by induced dipoles. The great variety of stress regimes includes nonmonotonic behaviors, multiresonances, negative viscosity effect, and blockades. The reversibility of the transitions between the different regimes and the self-similarity of the stresses make this phenomenon controllable and therefore applicable to modify macroscopic properties of soft condensed matter phases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Ethical conflicts are arising as a result of the growing complexity of clinical care, coupled with technological advances. Most studies that have developed instruments for measuring ethical conflict base their measures on the variables"frequency" and"degree of conflict". In our view, however, these variables are insufficient for explaining the root of ethical conflicts. Consequently, the present study formulates a conceptual model that also includes the variable"exposure to conflict", as well as considering six"types of ethical conflict". An instrument was then designed to measure the ethical conflicts experienced by nurses who work with critical care patients. The paper describes the development process and validation of this instrument, the Ethical Conflict in Nursing Questionnaire Critical Care Version (ECNQ-CCV). Methods: The sample comprised 205 nursing professionals from the critical care units of two hospitals in Barcelona (Spain). The ECNQ-CCV presents 19 nursing scenarios with the potential to produce ethical conflict in the critical care setting. Exposure to ethical conflict was assessed by means of the Index of Exposure to Ethical Conflict (IEEC), a specific index developed to provide a reference value for each respondent by combining the intensity and frequency of occurrence of each scenario featured in the ECNQ-CCV. Following content validity, construct validity was assessed by means of Exploratory Factor Analysis (EFA), while Cronbach"s alpha was used to evaluate the instrument"s reliability. All analyses were performed using the statistical software PASW v19. Results: Cronbach"s alpha for the ECNQ-CCV as a whole was 0.882, which is higher than the values reported for certain other related instruments. The EFA suggested a unidimensional structure, with one component accounting for 33.41% of the explained variance. Conclusions: The ECNQ-CCV is shown to a valid and reliable instrument for use in critical care units. Its structure is such that the four variables on which our model of ethical conflict is based may be studied separately or in combination. The critical care nurses in this sample present moderate levels of exposure to ethical conflict. This study represents the first evaluation of the ECNQ-CCV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Ethical conflicts are arising as a result of the growing complexity of clinical care, coupled with technological advances. Most studies that have developed instruments for measuring ethical conflict base their measures on the variables"frequency" and"degree of conflict". In our view, however, these variables are insufficient for explaining the root of ethical conflicts. Consequently, the present study formulates a conceptual model that also includes the variable"exposure to conflict", as well as considering six"types of ethical conflict". An instrument was then designed to measure the ethical conflicts experienced by nurses who work with critical care patients. The paper describes the development process and validation of this instrument, the Ethical Conflict in Nursing Questionnaire Critical Care Version (ECNQ-CCV). Methods: The sample comprised 205 nursing professionals from the critical care units of two hospitals in Barcelona (Spain). The ECNQ-CCV presents 19 nursing scenarios with the potential to produce ethical conflict in the critical care setting. Exposure to ethical conflict was assessed by means of the Index of Exposure to Ethical Conflict (IEEC), a specific index developed to provide a reference value for each respondent by combining the intensity and frequency of occurrence of each scenario featured in the ECNQ-CCV. Following content validity, construct validity was assessed by means of Exploratory Factor Analysis (EFA), while Cronbach"s alpha was used to evaluate the instrument"s reliability. All analyses were performed using the statistical software PASW v19. Results: Cronbach"s alpha for the ECNQ-CCV as a whole was 0.882, which is higher than the values reported for certain other related instruments. The EFA suggested a unidimensional structure, with one component accounting for 33.41% of the explained variance. Conclusions: The ECNQ-CCV is shown to a valid and reliable instrument for use in critical care units. Its structure is such that the four variables on which our model of ethical conflict is based may be studied separately or in combination. The critical care nurses in this sample present moderate levels of exposure to ethical conflict. This study represents the first evaluation of the ECNQ-CCV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to evaluate the natural attack by Acromyrmex crassispinus in initial Pinus taeda plantations without control measures against ants, as well as the effect of defoliation in seedlings of P. taeda. Evaluations of the attack of leaf-cutting ants on P. taeda plantations were done monthly in the first six months, then 9 and 12 months after planting. The percentages of plants that were naturally attacked by ants were registered. The effect of defoliation was evaluated by artificial defoliation, simulating the natural patterns of attack by A. crassispinus on P. taeda seedlings. The natural attack of A. crassispinus was greater during the first months after planting, being more intense in the first 30 days. Artificial defoliation indicated that there were no significant losses in diameter and height in plants with less than 75% defoliation. However, there were significant losses in diameter and height in plants with 100% defoliation, independently of the cut of the apical meristem, and also plant death. The control of leaf-cutting ants in P. taeda plantings, in which A. crassispinus is the most frequent leaf-cutting ant, should be intense only at the beginning of planting, since the most severe attacks occur during this time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Seven tesla (T) MR imaging is potentially promising for the morphologic evaluation of coronary arteries because of the increased signal-to-noise ratio compared to lower field strengths, in turn allowing improved spatial resolution, improved temporal resolution, or reduced scanning times. However, there are a large number of technical challenges, including the commercial 7 T systems not being equipped with homogeneous body radiofrequency coils, conservative specific absorption rate constraints, and magnified sample-induced amplitude of radiofrequency field inhomogeneity. In the present study, an initial attempt was made to address these challenges and to implement coronary MR angiography at 7 T. A single-element radiofrequency transmit and receive coil was designed and a 7 T specific imaging protocol was implemented, including significant changes in scout scanning, contrast generation, and navigator geometry compared to current protocols at 3 T. With this methodology, the first human coronary MR images were successfully obtained at 7 T, with both qualitative and quantitative findings being presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: A hybrid intervention is a joint procedure involving the interventional cardiologist and the cardiac surgeon. At our institution we have opted for this type of approach in congenital heart disease since 2005. We report here our initial experience. Cases: 1. A 3 year old boy with double aortic arch and multiple muscular ventricular septal defects (VSD),was readdressed for pulmonary band (PAB) removal and residual VSD closure after previous palliation. After surgical removal of the PAB, the surgeon provided a minimal transventricular access for placement of a 6mm Amplatzer® muscular VSD occluder by the cardiologist under transoesophageal guidance. The patient was extubated the same day and discharged after 5 days. 2. An 8 year old girl with Williams syndrome was followed for two large VSDs and severe peripheral pulmonary arteries (PA) stenosis. The membranous VSD was closed surgically, the muscular VSD during the same operation by direct placement of a 12 mm Amplatzer® muscular VSD occluder. During rewarming, balloon angioplasty of peripheral PA stenosis was achieved under fluoroscopy. Patient was extubated the following day and discharged after 8 days. 3. A 9 year old boy post tetralogy of Fallot repair had severe distal stenosis of the right ventricular to PA conduit.With patient on partial cardiopulmonary bypass, an incision was made on the conduit and a CP 8 Zig 16 stent placed on the stenosis. The child passed on full bypass and the definitive placement of the stent achieved. The child was extubated at the end of the intervention and discharged after 6 days. 4. A newborn presented at 2 days life with complex aortic arch anatomy: left aortic arch and right descending thoracic aorta perfused directly from a right arterial duct and left PA atresia. The arterial duct was stented with a Genesis XD stent dilated at 7mm. Two days later the cardiac surgeon made banded the right PA. The child was extubated after the operation and discharged a week later. Conclusion: Hybrid approach opens new ways of correction or palliation in congenital heart disease with encouraging results and less morbidity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

rejection can lead to loss of function. Histological reading of endomyocardial biopsy remains the "gold standard" for guiding immunosuppression, despite its methodological limitations (sampling error and interobserver variability). The measurement of the T2 relaxation time has been suggested for detection of allograft rejection, on the pathophysiological basis that the T2 relaxation time prolongs with local edema resulting from acute allograft rejection. Using breath-held cardiac magnetic resonance T2 mapping at 1.5 T, Usman et al. (CircCardiovascImaging2012) detected moderate allograft rejection (grade 2R, ISHLT 2004). With modern immunosuppression grade 2R rejection has become a rare event, but the need remains for a technique that permits the discrimination of absent (grade 0R) and mild rejection (grade 1R). We therefore investigated whether an increase of magnetic field strength to 3T and the use of real-time navigator-gated respiration compensation allow for an increase in the sensitivity of T2 relaxation time detection that is necessary to achieve this discrimination. Methods: Eighteen patients received EMB (Tan et al., ArchPatholLabMed2007) and cardiac T2 mapping on the same day. Reading of T2 maps was blinded to the histological results. For final analysis, 3 cases with known 2R rejection at the time of T2 mapping were added, yielding 21 T2 mapping sessions. A respiration-navigator-gated radial gradient-recalled-echo pulse sequence (resolution 1.17 mm2, matrix 2562, trigger time 3 heartbeats, T2 preparation duration TET2 Prep = 60/30/0 ms) was applied to obtain 3 short-axis T2 maps (van Heeswijk et al., JACCCardiovascImaging2012), which were segmented according to AHA guidelines (Cerqueira et al, Circulation2001). The highest segmental T2 values were grouped according to histological rejection grade and differences were analyzed by Student's t-test, except for the non-blinded cases with 2R rejection. The degree of discrimination was determined using the Spearman's ranked correlation test. Results: The high-quality T2 maps allowed for visual differentiation of the rejection degrees (Figure 1), and the correlation of T2 mapping with the histological grade of acute cellular rejection was significant (Spearman's r = 0.56, p = 0.007). The 0R (n = 15) and 1R (n = 3) degrees demonstrated significantly different T2 values (46.9 ± 5.0 and 54.3 ± 3.0 ms, p = 0.02, Figure 2). Cases with 2R rejection showed clear T2 elevation (T2 = 60.3 ± 16.2 ms). Conclusions: This pilot study demonstrates that non-invasive free-breathing cardiac T2 mapping at 3T discriminates between no and mild cardiac allograft rejection. Confirmation of these encouraging results in a larger cohort should consider a study able to show equivalency or superiority of T2 mapping.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Salt and heat stresses, which are often combined in nature, induce complementing defense mechanisms. Organisms adapt to high external salinity by accumulating small organic compounds known as osmolytes, which equilibrate cellular osmotic pressure. Osmolytes can also act as "chemical chaperones" by increasing the stability of native proteins and assisting refolding of unfolded polypeptides. Adaptation to heat stress depends on the expression of heat-shock proteins, many of which are molecular chaperones, that prevent protein aggregation, disassemble protein aggregates, and assist protein refolding. We show here that Escherichia coli cells preadapted to high salinity contain increased levels of glycine betaine that prevent protein aggregation under thermal stress. After heat shock, the aggregated proteins, which escaped protection, were disaggregated in salt-adapted cells as efficiently as in low salt. Here we address the effects of four common osmolytes on chaperone activity in vitro. Systematic dose responses of glycine betaine, glycerol, proline, and trehalose revealed a regulatory effect on the folding activities of individual and combinations of chaperones GroEL, DnaK, and ClpB. With the exception of trehalose, low physiological concentrations of proline, glycerol, and especially glycine betaine activated the molecular chaperones, likely by assisting local folding in chaperone-bound polypeptides and stabilizing the native end product of the reaction. High osmolyte concentrations, especially trehalose, strongly inhibited DnaK-dependent chaperone networks, such as DnaK+GroEL and DnaK+ClpB, likely because high viscosity affects dynamic interactions between chaperones and folding substrates and stabilizes protein aggregates. Thus, during combined salt and heat stresses, cells can specifically control protein stability and chaperone-mediated disaggregation and refolding by modulating the intracellular levels of different osmolytes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: A few studies have suggested an association between prenatal exposure to methylmercury and decreased heart rate variability (HRV) related to autonomic heart function, but no study has examined this association using baroreflex sensitivity (BRS). In this study we assessed the distribution of BRS and immediate orthostatic hypotension (IOH) in young Seychellois adults and their associations with exposure to prenatal and recent postnatal methylmercury. METHODS: Subjects in the Seychelles Child Development Study (SCDS) main cohort were evaluated at age 19 years. Non-invasive beat-to-beat blood pressure (BP) monitoring (Finapres, Ohmeda) was performed at rest and during active standing in 95 consecutive subjects. Recent postnatal mercury exposure was measured in subjects' hair at the age of 19 years and prenatal exposure in maternal hair grown during pregnancy. BRS was estimated by sequence analysis to identify spontaneous ascending and descending BP ramps. HRV was estimated by the following markers: PNN50 (relative numbers of normal-to-normal intervals which are shorter by more than 50 ms than the immediately following normal-to-normal intervals); rMSSD (root mean of the squared sum of successive interval differences); LF/HF (low frequency/high frequency component ratio); ratio of the mean expiratory/inspiratory RR intervals (EI ratio); and the ratio between the longest RR interval 30 s after active standing and the shortest RR interval at 15 s (Max30/Min15). IOH was estimated by the deepest BP fall within the first 15 s after active standing up. RESULTS: Prenatal MeHg exposures were similar in boys and girls (6.7±4.3, 6.7±3.8 ng/g) but recent postnatal mercury levels were higher in males than females (11.2±5.8 vs 7.9±4.3 ng/g, p=0.003). Markers of autonomic heart rate control were within the normal range (BRS: 24.8±7 ms/mm Hg, PNN50: 24.9±6.8%, rMSSD: 68±22, LF/HF: 0.61±0.28) in both sexes. After standing, 51.4% of subjects had a transient systolic BP drop>40 mm Hg, but only 5.3% reported dizziness or had syncope. Prenatal and recent postnatal MeHg levels, overall, were not associated with BRS, E/I ratio, PNN50, rMSSD, LF/HF ratio, Max30/Min15 ratio, and IOH. CONCLUSIONS: This study provides no support for the hypothesis that prenatal or recent postnatal MeHg exposure from fish consumption is associated with impaired autonomic heart rate control.