973 resultados para Implantable Infusion pumps
Resumo:
Background: Handling Totally Implantable Access Ports (TIAP) is a nursing procedure that requires skill and knowledge to avoid adverse events. No studies addressing this procedure with undergraduate students were identified prior to this study. Communication technologies, such as videos, have been increasingly adopted in the teaching of nursing and have contributed to the acquisition of competencies for clinical performance. Objective: To evaluate the effect of a video on the puncture and heparinization of TIAP in the development of cognitive and technical competencies of undergraduate nursing students. Method: Quasi-experimental study with a pretest-posttest design. Results: 24 individuals participated in the study. Anxiety scores were kept at levels 1 and 2 in the pretest and posttest. In relation to cognitive knowledge concerning the procedure, the proportion of correct answers in the pretest was 0.14 (SD=0.12) and 0.90 in the posttest (SD=0.05). After watching the video, the average score obtained by the participants in the mock session was 27.20. Conclusion: The use of an educational video with a simulation of puncture and heparinization of TIAP proved to be a strategy that increased both cognitive and technical knowledge. This strategy is viable in the teaching-learning process and is useful as a support tool for professors and for the development of undergraduate nursing students. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Assessing the efficacy of implantable cardioverter-defibrillators (ICD) in patients with Chagas' heart disease (ChHD) and identifying the clinical predictors of mortality and ICD shock during long-term follow-up. ChHD is associated with ventricular tachyarrhythmias and an increased risk of sudden cardiac death. Although ChHD is a common form of cardiomyopathy in Latin American ICD users, little is known about its efficacy in the treatment of this population. The study cohort included 116 consecutive patients with ChHD and an ICD implanted for secondary prevention. Of the 116 patients, 83 (72%) were men; the mean age was 54 +/- 10.7 years. Several clinical variables were tested in a multivariate Cox model for predicting long-term mortality. The average follow-up was 45 +/- 32 months. New York Heart Association class I-II developed in 83% of patients. The mean left ventricular ejection fraction was 42 +/- 16% at implantation. Of the 116 patients, 58 (50%) had appropriate shocks and 13 (11%) had inappropriate therapy. A total of 31 patients died (7.1% annual mortality rate). New York Heart Association class III (hazard ratio [HR] 3.09, 95% confidence interval 1.37 to 6.96, p = 0.0064) was a predictor of a worse prognosis. The left ventricular ejection fraction (HR 0.972, 95% confidence interval 0.94 to 0.99, p = 0.0442) and low cumulative right ventricular pacing (HR 0.23, 95% confidence interval 0.11 to 0.49, p = 0.0001) were predictors of better survival. The left ventricular diastolic diameter was an independent predictor of appropriate shock (I-ER 1.032, 95% confidence interval 1.004 to 1.060, p = 0.025). In conclusion, in a long-term follow-up, ICD efficacy for secondary sudden cardiac death prevention in patients with ChHD was marked by a favorable annual rate of all-cause mortality (7.1%); 50% of the cohort received appropriate shock therapy. New York Heart Association class III and left ventricular ejection fraction were independent predictors of worse prognosis, and low cumulative right ventricular pacing defined better survival. (C) 2012 Elsevier Inc. All rights reserved. (Am J Cardiol 2012;110:1040-1045)
Resumo:
Purpose: Insertion of totally implantable catheters via deep vessels that drain into the superior vena cava results in a lower incidence of venous thrombosis and infection as compared to catheters inserted into femoral and arm veins. Superior vena cava obstruction and inadequacy of the thoracic wall are conditions that prevent reservoir implantation in the chest wall. In this article, we describe a technical innovation that enables the pocket to be fixed in the arm while still allowing access to be achieved via the internal jugular vein. Method: The procedure reported maintains the use of the internal jugular vein for access even when the patient's chest is not suited for reservoir implantation, which is localized in the arm. Results: The procedure was successful and no complications occurred. The position of the catheter tip did not alter with arm movement. Conclusion: The implantation of a port reservoir in the arm following venous access via the internal jugular vein is both safe and convenient.
Resumo:
It is already known that progressive degeneration of cholinergic neurons in brain areas such as the hippocampus and the cortex leads to memory deficits, as observed in Alzheimer's disease. This work verified the effects of the infusion of amyloid-beta (A beta) peptide associated to an attentional rehearsal on the density of alpha 7 nicotinic cholinergic receptor (nAChR) in the brain of male Wistar rats. Animals received intracerebroventricular infusion of A beta or vehicle (control - C) and their attention was stimulated weekly (Stimulated A beta group: S-A beta and Stimulated Control group: SC) or not (Non-Stimulated A beta group: N-SA beta and Non-Stimulated Control group: N-SC), using an active avoidance apparatus. Conditioned avoidance responses (CAR) were registered. Chronic infusion of A beta caused a 37% reduction in CAR for N-SA beta. In S-A beta, this reduction was not observed. At the end, brains were extracted and autoradiography for alpha 7 nAChR was conducted using [I-125]-alpha-bungarotoxin. There was an increase in alpha 7 density in hippocampus, cortex and amygdala of SA beta animals, together with the memory preservation. In recent findings from our lab using mice infused with A beta and the alpha 7 antagonist methyllycaconitine, and stimulated weekly in the same apparatus, it was observed that memory maintenance was abolished. So, the increase in alpha 7 density in brain areas related to memory might be related to a participation of this receptor in the long-lasting change in synaptic plasticity, which is important to improve and maintain memory consolidation.
Resumo:
The expression of tlr4, md2 and cd14 was studied in equine blood leukocytes and in intestinal samples using real time PCR. The stability of three commonly used reference genes, glyceraldehyde-3P-dehydrogenase (GAPDH), hypoxantine ribosyltransferase (HPRT) and succinate dehydrogenase complex subunit A (SDHA), was evaluated using qbase(PLUS). The equine peripheral blood mononuclear cells (eqPBMC) examined were either stimulated in vitro with Phorbol 12-myristate 13-acetate (PMA) and ionomycin or with the CpG oligodeoxynuclotide 2216 (CpG-ODN 2216) or obtained from horses before, during and after infusion of endotoxin. Intestinal tissue from healthy horses was sampled at ileum, right dorsal colon and rectum. Ranking of the three reference genes used for normalisation identified the combination HPRT/SDHA as most suitable both when determined ex vivo in leukocytes obtained from experimentally induced endotoxaemia and in eqPBMC activated in vitro while HPRT/GAPDH were most appropriate for the intestinal samples. The relative amounts of mRNA for TLR4 and MD-2 increased threefold during in vitro activation of the cells with CpG-ODN 2216 but was decreased in cultures stimulated with PMA/ionomycin. A transient elevation in the transcription of tlr4 and md2 was also evident for equine blood leukocytes following endotoxaemia. The levels of mRNA for CD14 on the other hard remained unaffected both during the induction of endotoxaemia and in the in vitro stimulated PBMCs. A low steady expression of TLR4, MD-2 and CD14 mRNA was demonstrated for the intestinal samples with no variation between the intestinal segments analysed. Thus, the foundation for real time PCR based levels of analysis of mRNA for all three components in the equine LPS receptor complex in different intestinal segments was set, making it possible to carry out future expression studies on clinical material. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
Background: Parenteral lipid emulsions (LEs) can influence leukocyte functions. The authors investigated the effect of 2 LEs on leukocyte death in surgical patients with gastrointestinal cancer. Material and Methods: Twenty-five patients from a randomized, double-blind clinical trial (ID: NCT01218841) were randomly included to evaluate leukocyte death after 3 days of preoperative infusion (0.2 g fat/kg/d) of an LE composed equally of medium/long-chain triglycerides and soybean oil (MCTs/LCTs) or pure fish oil (FO). Blood samples were collected before (t0) and after LE infusion (t1) and on the third postoperative day (t2). Results: After LE infusion (t1 vs t0), MCTs/LCTs did not influence cell death; FO slightly increased the proportion of necrotic lymphocytes (5%). At the postoperative period (t2 vs t0), MCTs/LCTs tripled the proportion of apoptotic lymphocytes; FO maintained the slightly increased proportion of necrotic lymphocytes (7%) and reduced the percentage of apoptotic lymphocytes by 74%. In the postoperative period, MCT/LCT emulsion increased the proportion of apoptotic neutrophils, and FO emulsion did not change any parameter of apoptosis in the neutrophil population. There were no differences in lymphocyte or neutrophil death when MCT/LCT and FO treatments were compared during either preoperative or postoperative periods. MCT/LCTs altered the expression of 12 of 108 genes related to cell death, with both pro- and antiapoptotic effects; FO modulated the expression of 7 genes, demonstrating an antiapoptotic effect. Conclusion: In patients with gastrointestinal cancer, preoperative MCT/LCT infusion was associated with postoperative lymphocyte and neutrophil apoptosis. FO has a protective effect on postoperative lymphocyte apoptosis. (JPEN J Parenter Enteral Nutr. 2012; 36: 677-684)
Resumo:
Background: Intralipid (R) and heparin infusion results in increased blood pressure and autonomic abnormalities in normal and hypertensive individuals. Objective: To evaluate insulin sensitivity and the impact of Intralipid (R) and heparin (ILH) infusion on hemodynamic, metabolic, and autonomic response in patients with the indeterminate form of Chagas' disease. Methods: Twelve patients with the indeterminate form of Chagas' disease and 12 healthy volunteers were evaluated. Results: Baseline blood pressure and heart rate were similar in both groups. Plasma noradrenaline levels were slightly increased in the Chagas' group. After insulin tolerance testing (ITT), a significant decline was noted in glucose in both groups. ILH infusion resulted in increased blood pressure in both groups, but there was no significant change in plasma noradrenaline. The low-frequency component (LF) was similar and similarly increased in both groups. The high-frequency component (HF) was lower in the Chagas' group. Conclusion: Patients with the indeterminate form of Chagas' disease had increased sympathetic activity at baseline and impaired response to insulin. They also had a lower high-frequency component and impaired baroreflex sensitivity at baseline and during Intralipid (R) and heparin infusion. (Arq Bras Cardiol 2012;98(3):225-233)
Resumo:
Abstract Background Myocardial contrast echocardiography has been used for determination of infarct size (IS) in experimental models. However, with intermittent harmonic imaging, IS seems to be underestimated immediately after reperfusion due to areas with preserved, yet dysfunctional, microvasculature. The use of exogenous vasodilators showed to be useful to unmask these infarcted areas with depressed coronary flow reserve. This study was undertaken to assess the value of adenosine for IS determination in an open-chest canine model of coronary occlusion and reperfusion, using real-time myocardial contrast echocardiography (RTMCE). Methods Nine dogs underwent 180 minutes of coronary occlusion followed by reperfusion. PESDA (Perfluorocarbon-Exposed Sonicated Dextrose Albumin) was used as contrast agent. IS was determined by RTMCE before and during adenosine infusion at a rate of 140 mcg·Kg-1·min-1. Post-mortem necrotic area was determined by triphenyl-tetrazolium chloride (TTC) staining. Results IS determined by RTMCE was 1.98 ± 1.30 cm2 and increased to 2.58 ± 1.53 cm2 during adenosine infusion (p = 0.004), with good correlation between measurements (r = 0.91; p < 0.01). The necrotic area determined by TTC was 2.29 ± 1.36 cm2 and showed no significant difference with IS determined by RTMCE before or during hyperemia. A slight better correlation between RTMCE and TTC measurements was observed during adenosine (r = 0.99; p < 0.001) then before it (r = 0.92; p = 0.0013). Conclusion RTMCE can accurately determine IS in immediate period after acute myocardial infarction. Adenosine infusion results in a slight better detection of actual size of myocardial damage.
Resumo:
Abstract Introduction We conducted the present study to investigate whether early large-volume crystalloid infusion can restore gut mucosal blood flow and mesenteric oxygen metabolism in severe sepsis. Methods Anesthetized and mechanically ventilated male mongrel dogs were challenged with intravenous injection of live Escherichia coli (6 × 109 colony-forming units/ml per kg over 15 min). After 90 min they were randomly assigned to one of two groups – control (no fluids; n = 13) or lactated Ringer's solution (32 ml/kg per hour; n = 14) – and followed for 60 min. Cardiac index, mesenteric blood flow, mean arterial pressure, systemic and mesenteric oxygen-derived variables, blood lactate and gastric carbon dioxide tension (PCO2; by gas tonometry) were assessed throughout the study. Results E. coli infusion significantly decreased arterial pressure, cardiac index, mesenteric blood flow, and systemic and mesenteric oxygen delivery, and increased arterial and portal lactate, intramucosal PCO2, PCO2 gap (the difference between gastric mucosal and arterial PCO2), and systemic and mesenteric oxygen extraction ratio in both groups. The Ringer's solution group had significantly higher cardiac index and systemic oxygen delivery, and lower oxygen extraction ratio and PCO2 gap at 165 min as compared with control animals. However, infusion of lactated Ringer's solution was unable to restore the PCO2 gap. There were no significant differences between groups in mesenteric oxygen delivery, oxygen extraction ratio, or portal lactate at the end of study. Conclusion Significant disturbances occur in the systemic and mesenteric beds during bacteremic severe sepsis. Although large-volume infusion of lactated Ringer's solution restored systemic hemodynamic parameters, it was unable to correct gut mucosal PCO2 gap.
Resumo:
The present PhD thesis exploits the design skills I have been improving since my master thesis’ research. A brief description of the chapters’ content follows. Chapter 1: the simulation of a complete front–end is a very complex problem and, in particular, is the basis upon which the prediction of the overall performance of the system is possible. By means of a commercial EM simulation tool and a rigorous nonlinear/EM circuit co–simulation based on the Reciprocity Theorem, the above–mentioned prediction can be achieved and exploited for wireless links characterization. This will represent the theoretical basics of the entire present thesis and will be supported by two RF applications. Chapter 2: an extensive dissertation about Magneto–Dielectric (MD) materials will be presented, together with their peculiar characteristics as substrates for antenna miniaturization purposes. A designed and tested device for RF on–body applications will be described in detail. Finally, future research will be discussed. Chapter 3: this chapter will deal with the issue regarding the exploitation of renewable energy sources for low–energy consumption devices. Hence the problem related to the so–called energy harvesting will be tackled and a first attempt to deploy THz solar energy in an innovative way will be presented and discussed. Future research will be proposed as well. Chapter 4: graphene is a very promising material for devices to be exploited in the RF and THz frequency range for a wide range of engineering applications, including those ones marked as the main research goal of the present thesis. This chapter will present the results obtained during my research period at the National Institute for Research and Development in Microtechnologies (IMT) in Bucharest, Romania. It will concern the design and manufacturing of antennas and diodes made in graphene–based technology for detection/rectification purposes.
Resumo:
Due to its practical importance and inherent complexity, the optimisation of distribution networks for supplying drinking water has been the subject of extensive study for the past 30 years. The optimization is governed by sizing the pipes in the water distribution network (WDN) and / or optimises specific parts of the network such as pumps, tanks etc. or try to analyse and optimise the reliability of a WDN. In this thesis, the author has analysed two different WDNs (Anytown City and Cabrera city networks), trying to solve and optimise a multi-objective optimisation problem (MOOP). The main two objectives in both cases were the minimisation of Energy Cost (€) or Energy consumption (kWh), along with the total Number of pump switches (TNps) during a day. For this purpose, a decision support system generator for Multi-objective optimisation used. Its name is GANetXL and has been developed by the Center of Water System in the University of Exeter. GANetXL, works by calling the EPANET hydraulic solver, each time a hydraulic analysis has been fulfilled. The main algorithm used, was a second-generation algorithm for multi-objective optimisation called NSGA_II that gave us the Pareto fronts of each configuration. The first experiment that has been carried out was the network of Anytown city. It is a big network with a pump station of four fixed speed parallel pumps that are boosting the water dynamics. The main intervention was to change these pumps to new Variable speed driven pumps (VSDPs), by installing inverters capable to diverse their velocity during the day. Hence, it’s been achieved great Energy and cost savings along with minimisation in the number of pump switches. The results of the research are thoroughly illustrated in chapter 7, with comments and a variety of graphs and different configurations. The second experiment was about the network of Cabrera city. The smaller WDN had a unique FS pump in the system. The problem was the same as far as the optimisation process was concerned, thus, the minimisation of the energy consumption and in parallel the minimisation of TNps. The same optimisation tool has been used (GANetXL).The main scope was to carry out several and different experiments regarding a vast variety of configurations, using different pump (but this time keeping the FS mode), different tank levels, different pipe diameters and different emitters coefficient. All these different modes came up with a large number of results that were compared in the chapter 8. Concluding, it should be said that the optimisation of WDNs is a very interested field that has a vast space of options to deal with. This includes a large number of algorithms to choose from, different techniques and configurations to be made and different support system generators. The researcher has to be ready to “roam” between these choices, till a satisfactory result will convince him/her that has reached a good optimisation point.
Resumo:
An implantable transducer for monitoring the flow of Cerebrospinal fluid (CSF) for the treatment of hydrocephalus has been developed which is based on measuring the heat dissipation of a local thermal source. The transducer uses passive telemetry at 13.56 MHz for power supply and read out of the measured flow rate. The in vitro performance of the transducer has been characterized using artificial Cerebrospinal Fluid (CSF) with increased protein concentration and artificial CSF with 10\% fresh blood. After fresh blood was added to the artificial CSF a reduction of flow rate has been observed in case that the sensitive surface of the flow sensor is close to the sedimented erythrocytes. An increase of flow rate has been observed in case that the sensitive surface is in contact with the remaining plasma/artificial CSF mix above the sediment which can be explained by an asymmetric flow profile caused by the sedimentation of erythrocythes having increased viscosity compared to artificial CSF. After removal of blood from artificial CSF, no drift could be observed in the transducer measurement which could be associated to a deposition of proteins at the sensitive surface walls of the packaged flow transducer. The flow sensor specification requirement of +-10\% for a flow range between 2 ml/h and 40 ml/h. could be confirmed at test conditions of 37 degrees C.
Resumo:
The Oxford Programme for Immunomodulatory Immunoglobulin Therapy has been operating since 1992 at Oxford Radcliffe Hospitals in the UK. Initially, this program was set up for patients with multifocal motor neuropathy or chronic inflammatory demyelinating poly-neuropathy to receive reduced doses of intravenous immunoglobulin (IVIG) in clinic on a regular basis (usually every 3 weeks). The program then rapidly expanded to include self-infusion at home, which monitoring showed to be safe and effective. It has been since extended to the treatment of other autoimmune diseases in which IVIG has been shown to be efficacious.
Resumo:
The rate of extra-hepatic lactate production and the route of influx of lactate to the liver may influence both hepatic and extra-hepatic lactate exchange. We assessed the dose-response of hepatic and extra-hepatic lactate exchange during portal and central venous lactate infusion.
Resumo:
Plasma copeptin levels before and during exogenous arginine vasopressin infusion (AVP) were evaluated, and the value of copeptin levels before AVP therapy to predict complications during AVP therapy and outcome in vasodilatory shock patients was determined.