875 resultados para Image acquisition and representation
Resumo:
Due to design and process-related factors, there are local variations in the microstructure and mechanical behaviour of cast components. This work establishes a Digital Image Correlation (DIC) based method for characterisation and investigation of the effects of such local variations on the behaviour of a high pressure, die cast (HPDC) aluminium alloy. Plastic behaviour is studied using gradient solidified samples and characterisation models for the parameters of the Hollomon equation are developed, based on microstructural refinement. Samples with controlled microstructural variations are produced and the observed DIC strain field is compared with Finite Element Method (FEM) simulation results. The results show that the DIC based method can be applied to characterise local mechanical behaviour with high accuracy. The microstructural variations are observed to cause a redistribution of strain during tensile loading. This redistribution of strain can be predicted in the FEM simulation by incorporating local mechanical behaviour using the developed characterization model. A homogeneous FEM simulation is unable to predict the observed behaviour. The results motivate the application of a previously proposed simulation strategy, which is able to predict and incorporate local variations in mechanical behaviour into FEM simulations already in the design process for cast components.
Resumo:
At what point in reading development does literacy impact object recognition and orientation processing? Is it specific to mirror images? To answer these questions, forty-six 5- to 7-year-old preschoolers and first graders performed two same–different tasks differing in the matching criterion-orientation-based versus shape-based (orientation independent)-on geometric shapes and letters. On orientation-based judgments, first graders out- performed preschoolers who had the strongest difficulty with mirrored pairs. On shape-based judgments, first graders were slower for mirrored than identical pairs, and even slower than preschoolers. This mirror cost emerged with letter knowledge. Only first graders presented worse shape-based judgments for mirrored and rotated pairs of reversible (e.g., b-d; b-q) than nonreversible (e.g., e-ә) letters, indicating readers’ difficulty in ignoring orientation contrasts relevant to letters.
Resumo:
El Niño-Southern Oscillation (ENSO) è il maggiore fenomeno climatico che avviene a livello dell’Oceano Pacifico tropicale e che ha influenze ambientali, climatiche e socioeconomiche a larga scala. In questa tesi si ripercorrono i passi principali che sono stati fatti per tentare di comprendere un fenomeno così complesso. Per prima cosa, si sono studiati i meccanismi che ne governano la dinamica, fino alla formulazione del modello matematico chiamato Delayed Oscillator (DO) model, proposto da Suarez e Schopf nel 1988. In seguito, per tenere conto della natura caotica del sistema studiato, si è introdotto nel modello lo schema chiamato Stochastically Perturbed Parameterisation Tendencies (SPPT). Infine, si sono portati due esempi di soluzione numerica del DO, sia con che senza l’introduzione della correzione apportata dallo schema SPPT, e si è visto in che misura SPPT porta reali miglioramenti al modello studiato.
Resumo:
The characterization of physical properties of digital imaging systems requires the determination and measurement of detectors’ physical performance. Those measures such as modulation transfer function (MTF), noise power spectra (NPS), and detective quantum efficiency (DQE) provide objective evaluations of digital detectors’ performance. To provide an MTF, NPS, and DQE calculation from raw-data images it is necessary to implement a method that is undertaken by two major steps: (1) image acquisition and (2) quantitative measure determination method. In this chapter a comprehensive description about a method to provide the measure of performance of digital radiography detectors is provided.
Resumo:
Hyperspectral instruments have been incorporated in satellite missions, providing large amounts of data of high spectral resolution of the Earth surface. This data can be used in remote sensing applications that often require a real-time or near-real-time response. To avoid delays between hyperspectral image acquisition and its interpretation, the last usually done on a ground station, onboard systems have emerged to process data, reducing the volume of information to transfer from the satellite to the ground station. For this purpose, compact reconfigurable hardware modules, such as field-programmable gate arrays (FPGAs), are widely used. This paper proposes an FPGA-based architecture for hyperspectral unmixing. This method based on the vertex component analysis (VCA) and it works without a dimensionality reduction preprocessing step. The architecture has been designed for a low-cost Xilinx Zynq board with a Zynq-7020 system-on-chip FPGA-based on the Artix-7 FPGA programmable logic and tested using real hyperspectral data. Experimental results indicate that the proposed implementation can achieve real-time processing, while maintaining the methods accuracy, which indicate the potential of the proposed platform to implement high-performance, low-cost embedded systems, opening perspectives for onboard hyperspectral image processing.
Resumo:
The paper focuses on taking advantage of large amounts of data that are systematically stored in plants (by means of SCADA systems), but not exploited enough in order to achieve supervisory goals (fault detection, diagnosis and reconfiguration). The methodology of case base reasoning (CBR) is proposed to perform supervisory tasks in industrial processes by re-using the stored data. The goal is to take advantage of experiences, registered in a suitable structure as cam, avoiding the tedious task of knowledge acquisition and representation needed by other reasoning techniques as expert systems. An outlook of CBR terminology and basic concepts are presented. The adaptation of CBR in performing expert supervisory tasks, taking into account the particularities and difficulties derived from dynamic systems, is discussed. A special interest is focused in proposing a general case definition suitable for supervisory tasks. Finally, this structure and the whole methodology is tested in a application example for monitoring a real drier chamber
Resumo:
La tomodensitométrie (TDM) est une technique d'imagerie pour laquelle l'intérêt n'a cessé de croitre depuis son apparition au début des années 70. De nos jours, l'utilisation de cette technique est devenue incontournable, grâce entre autres à sa capacité à produire des images diagnostiques de haute qualité. Toutefois, et en dépit d'un bénéfice indiscutable sur la prise en charge des patients, l'augmentation importante du nombre d'examens TDM pratiqués soulève des questions sur l'effet potentiellement dangereux des rayonnements ionisants sur la population. Parmi ces effets néfastes, l'induction de cancers liés à l'exposition aux rayonnements ionisants reste l'un des risques majeurs. Afin que le rapport bénéfice-risques reste favorable au patient il est donc nécessaire de s'assurer que la dose délivrée permette de formuler le bon diagnostic tout en évitant d'avoir recours à des images dont la qualité est inutilement élevée. Ce processus d'optimisation, qui est une préoccupation importante pour les patients adultes, doit même devenir une priorité lorsque l'on examine des enfants ou des adolescents, en particulier lors d'études de suivi requérant plusieurs examens tout au long de leur vie. Enfants et jeunes adultes sont en effet beaucoup plus sensibles aux radiations du fait de leur métabolisme plus rapide que celui des adultes. De plus, les probabilités des évènements auxquels ils s'exposent sont également plus grandes du fait de leur plus longue espérance de vie. L'introduction des algorithmes de reconstruction itératifs, conçus pour réduire l'exposition des patients, est certainement l'une des plus grandes avancées en TDM, mais elle s'accompagne de certaines difficultés en ce qui concerne l'évaluation de la qualité des images produites. Le but de ce travail est de mettre en place une stratégie pour investiguer le potentiel des algorithmes itératifs vis-à-vis de la réduction de dose sans pour autant compromettre la qualité du diagnostic. La difficulté de cette tâche réside principalement dans le fait de disposer d'une méthode visant à évaluer la qualité d'image de façon pertinente d'un point de vue clinique. La première étape a consisté à caractériser la qualité d'image lors d'examen musculo-squelettique. Ce travail a été réalisé en étroite collaboration avec des radiologues pour s'assurer un choix pertinent de critères de qualité d'image. Une attention particulière a été portée au bruit et à la résolution des images reconstruites à l'aide d'algorithmes itératifs. L'analyse de ces paramètres a permis aux radiologues d'adapter leurs protocoles grâce à une possible estimation de la perte de qualité d'image liée à la réduction de dose. Notre travail nous a également permis d'investiguer la diminution de la détectabilité à bas contraste associée à une diminution de la dose ; difficulté majeure lorsque l'on pratique un examen dans la région abdominale. Sachant que des alternatives à la façon standard de caractériser la qualité d'image (métriques de l'espace Fourier) devaient être utilisées, nous nous sommes appuyés sur l'utilisation de modèles d'observateurs mathématiques. Nos paramètres expérimentaux ont ensuite permis de déterminer le type de modèle à utiliser. Les modèles idéaux ont été utilisés pour caractériser la qualité d'image lorsque des paramètres purement physiques concernant la détectabilité du signal devaient être estimés alors que les modèles anthropomorphes ont été utilisés dans des contextes cliniques où les résultats devaient être comparés à ceux d'observateurs humain, tirant profit des propriétés de ce type de modèles. Cette étude a confirmé que l'utilisation de modèles d'observateurs permettait d'évaluer la qualité d'image en utilisant une approche basée sur la tâche à effectuer, permettant ainsi d'établir un lien entre les physiciens médicaux et les radiologues. Nous avons également montré que les reconstructions itératives ont le potentiel de réduire la dose sans altérer la qualité du diagnostic. Parmi les différentes reconstructions itératives, celles de type « model-based » sont celles qui offrent le plus grand potentiel d'optimisation, puisque les images produites grâce à cette modalité conduisent à un diagnostic exact même lors d'acquisitions à très basse dose. Ce travail a également permis de clarifier le rôle du physicien médical en TDM: Les métriques standards restent utiles pour évaluer la conformité d'un appareil aux requis légaux, mais l'utilisation de modèles d'observateurs est inévitable pour optimiser les protocoles d'imagerie. -- Computed tomography (CT) is an imaging technique in which interest has been quickly growing since it began to be used in the 1970s. Today, it has become an extensively used modality because of its ability to produce accurate diagnostic images. However, even if a direct benefit to patient healthcare is attributed to CT, the dramatic increase in the number of CT examinations performed has raised concerns about the potential negative effects of ionising radiation on the population. Among those negative effects, one of the major risks remaining is the development of cancers associated with exposure to diagnostic X-ray procedures. In order to ensure that the benefits-risk ratio still remains in favour of the patient, it is necessary to make sure that the delivered dose leads to the proper diagnosis without producing unnecessarily high-quality images. This optimisation scheme is already an important concern for adult patients, but it must become an even greater priority when examinations are performed on children or young adults, in particular with follow-up studies which require several CT procedures over the patient's life. Indeed, children and young adults are more sensitive to radiation due to their faster metabolism. In addition, harmful consequences have a higher probability to occur because of a younger patient's longer life expectancy. The recent introduction of iterative reconstruction algorithms, which were designed to substantially reduce dose, is certainly a major achievement in CT evolution, but it has also created difficulties in the quality assessment of the images produced using those algorithms. The goal of the present work was to propose a strategy to investigate the potential of iterative reconstructions to reduce dose without compromising the ability to answer the diagnostic questions. The major difficulty entails disposing a clinically relevant way to estimate image quality. To ensure the choice of pertinent image quality criteria this work was continuously performed in close collaboration with radiologists. The work began by tackling the way to characterise image quality when dealing with musculo-skeletal examinations. We focused, in particular, on image noise and spatial resolution behaviours when iterative image reconstruction was used. The analyses of the physical parameters allowed radiologists to adapt their image acquisition and reconstruction protocols while knowing what loss of image quality to expect. This work also dealt with the loss of low-contrast detectability associated with dose reduction, something which is a major concern when dealing with patient dose reduction in abdominal investigations. Knowing that alternative ways had to be used to assess image quality rather than classical Fourier-space metrics, we focused on the use of mathematical model observers. Our experimental parameters determined the type of model to use. Ideal model observers were applied to characterise image quality when purely objective results about the signal detectability were researched, whereas anthropomorphic model observers were used in a more clinical context, when the results had to be compared with the eye of a radiologist thus taking advantage of their incorporation of human visual system elements. This work confirmed that the use of model observers makes it possible to assess image quality using a task-based approach, which, in turn, establishes a bridge between medical physicists and radiologists. It also demonstrated that statistical iterative reconstructions have the potential to reduce the delivered dose without impairing the quality of the diagnosis. Among the different types of iterative reconstructions, model-based ones offer the greatest potential, since images produced using this modality can still lead to an accurate diagnosis even when acquired at very low dose. This work has clarified the role of medical physicists when dealing with CT imaging. The use of the standard metrics used in the field of CT imaging remains quite important when dealing with the assessment of unit compliance to legal requirements, but the use of a model observer is the way to go when dealing with the optimisation of the imaging protocols.
Resumo:
Kirjallisuusarvostelu
Resumo:
The aim of this study was to use digital images acquired by cameras attached to a helium balloon to detect variation of the nutritional status in Brachiaria decumbens. The treatments consisted of five doses of nitrogen (0, 50, 100, 150 e 200kg ha-1) with six replications each, evaluated in a completely randomized statistical design. A remote sensing system composed of digital cameras and microcomputers was used for image acquisition, and a helium balloon lifted the cameras to the heights of 15, 20, 25 and 30m. A portable chlorophyll meter and analyses of leaf nitrogen content were used to make comparisons with data obtained by the remote sensing system. Data was acquired in two phases, in different climatic conditions. At the end of each phase, dry matter production was measured. Three vegetation indices were used to evaluate the detection of different nutritional status. The three indices were able to detect the effects of N doses. The indices constructed with the Green spectral band showed to be more efficient.
Resumo:
L’instrument le plus fréquemment utilisé pour la mesure de l’amplitude de mouvement du coude est le goniomètre universel. Or celui-ci ne fait pas l’unanimité : plusieurs auteurs remettent en question sa fiabilité et validité. Cette étude détaille donc, en trois étapes, une alternative beaucoup plus précise et exacte : une méthode radiographique de mesure. Une étude de modélisation a d’abord permis de repérer les sources d’erreur potentielles de cette méthode radiographique, à ce jour jamais utilisée pour le coude. La méthode a ensuite servi à évaluer la validité du goniomètre. À cette fin, 51 volontaires ont participé à une étude clinique où les deux méthodes ont été confrontées. Finalement, la mesure radiographique a permis de lever le voile sur l’influence que peuvent avoir différents facteurs démographiques sur l’amplitude de mouvement du coude. La méthode radiographique s’est montrée robuste et certaines sources d’erreurs facilement évitables ont été identifiées. En ce qui concerne l’étude clinique, l’erreur de mesure attribuable au goniomètre était de ±10,3° lors de la mesure du coude en extension et de ±7,0° en flexion. L’étude a également révélé une association entre l’amplitude de mouvement et différents facteurs, dont les plus importants sont l’âge, le sexe, l’IMC et la circonférence du bras et de l’avant-bras. En conclusion, l’erreur du goniomètre peut être tolérée en clinique, mais son utilisation est cependant déconseillée en recherche, où une erreur de mesure de l’ordre de 10° est inacceptable. La méthode radiographique, étant plus précise et exacte, représente alors une bien meilleure alternative.
Resumo:
The paper focuses on taking advantage of large amounts of data that are systematically stored in plants (by means of SCADA systems), but not exploited enough in order to achieve supervisory goals (fault detection, diagnosis and reconfiguration). The methodology of case base reasoning (CBR) is proposed to perform supervisory tasks in industrial processes by re-using the stored data. The goal is to take advantage of experiences, registered in a suitable structure as cam, avoiding the tedious task of knowledge acquisition and representation needed by other reasoning techniques as expert systems. An outlook of CBR terminology and basic concepts are presented. The adaptation of CBR in performing expert supervisory tasks, taking into account the particularities and difficulties derived from dynamic systems, is discussed. A special interest is focused in proposing a general case definition suitable for supervisory tasks. Finally, this structure and the whole methodology is tested in a application example for monitoring a real drier chamber
Resumo:
Image acquisition systems based on multi-head arrangement of digital frame cameras, such as the commercial systems DMC, UltraCam, besides others, are attractive alternatives enabling larger imaging area when compared to a single frame camera. Considering that in these systems, cameras are tightly attached to an external mount, it is assumed that relative position and orientation between cameras are stable during image acquisition and, consequently, these constraint can be included in the calibration step. This constraint is acceptable because estimates of the relative orientation (RO) parameters between cameras, from previously estimated exterior orientation parameters, present higher and significant deviations than the expected physical variations, due to error propagation. In order to solve this problem, this work presents an approach based on simultaneous calibration of two or more cameras using constraints that state that the relative rotation matrix and the distance between the cameras head are stable. Experiments with images acquired by an arrangement of two Hasselblad H2D cameras were accomplished, without and with the mentioned constraints. The experiments showed that the calibration process with RO constraints allows better results than the approach based on single camera calibration, provided that the estimation has included only images with good target distribution.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Some photosensitizers (PSs) used for PACT (Antimicrobial Photodynamic Therapy) show an affinity for bacterial walls and can be photo-activated to cause the desired damage. However, on dentine bacterias may be less susceptible to PACT as a result of limited penetration of the PS. The aim of this study was to evaluate the diffusion of one PS based on hematoporphyrin on dentine structures. Twelve bovine incisors were used. Class III cavities (3 x 3 x 1 mm) were prepared on the mesial or distal surfaces using a diamond bur. Photogem (R) solution at 1 mg/mL (10 uL for each cavity) was used. The experimental Groups were divided according to thickness of dentine remaining and etched or no-etched before the PS application. The fluorescence excitation source was a VelScope (R) system. For image capture a scientific CCD color camera PixelFly (R) was coupled to VelScope. For image acquisition and processing, a computational routine was developed at Matlab (R). Fick's Law was used to obtain the average diffusion coefficient of PS. Differences were found between all Groups. The longitudinal temporal diffusion was influenced by the different times, thickness and acid etching.
Resumo:
Intestinal parasitosis constitutes a serious health problem in most tropical countries. The diagnosis of enteroparasites in laboratory routine relies on the examination of stool samples using optical microscopy and the error rates usually range from moderate to high. Approaches based on automatic image analysis have been proposed, but the methods are usually specific for some species, some of them are computationally expensive, and image acquisition and focus are manual. We present a solution to automate the diagnosis of the 15 most common species of enteroparasites in Brazil, using a sensitive parasitological technique, a motorized microscope with digital camera for automatic image acquisition and focus, and fast image analysis methods. The results indicate that our solution is effective and suitable for laboratory routine, in which the exam must be concluded in a few minutes. © 2013 IEEE.