962 resultados para IMPLANTED LINBO3


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cavopulmonary connections have been extensively used in the palliation of complex forms of congenital heart disease requiring some form of right heart bypass. We examine the mid term outcomes of pulmonary ventricle bypass operations in a single institution and performed by the same surgical team. POPULATION: Between March 1999 and April 2006, 62 patients underwent pulmonary ventricle bypass operations: bidirectional cavopulmonary anastomosis (Glenn procedure), total cavopulmonary connections (Fontan procedure) and one and a half ventricle correction in two cases. Age at operation averaged three years (range: 0.42-25 years) for the Glenn procedure and seven years (range: 3-14 years) for the Fontan procedure. There were 36 male patients (58%) and 26 female patients (42%). The most common indication for surgery was the single ventricle defect, present in 66% of patients. Associated lesions included: transposition of the great arteries in 16 patients (35.6%), bilateral superior vena cava in four patients (8.9%), situs ambigus in five patients (11%), situs inversus in another patient (2.2%), Ebstein disease in one patient (2.2) and coronary fistula in another patient (2.2%). Sub-aortic stenosis was present in one patient (2.2%). Palliative surgery was performed in all, but three patients (5%), before the Fontan procedure. RESULTS: Thirty two patients underwent bidirectional cavopulmonary anastomosis and thirty patients underwent cavopulmonary connections, total or 2nd stage. Mean cardiopulmonary bypass times were 50.6+/-21.9 minutes for the Glenn procedure and 88.5+/-26.3 minutes for the Fontan procedure. There was no intra-operative mortality, but two patients (3.2% (died in the first month after surgery; one due to failure of the Glenn circuit and sepsis and the other due to a low cardiac output syndrome and multi-organ dysfunction. Mean ventilation time was 5.2+/-1.7 hours for the Glenn operation and 6.2+/-3.2 hours for the Fontan operation. The mean length of stay in ICU was 3.4+/-2.8 days for patients undergoing the Glenn operation and 4.6+/-3.1 days for patients undergoing the Fontan operation and the mean length of hospital stay was 10.6+/-5.8 days for the Glenn operation and 19.1+/-12.6 days for the Fontan operation respectively. The mean follow up time was 4+/-2.1 years (minimum 0 years and maximum seven years), most patients being in NYHA class I. Epicardiac pacemakers were implanted in three patients due to arrhythmias. Two re-operations (6.7%) were needed, both in the same patient, after the Fontan procedure, this patient eventually died a few years after surgery. CONCLUSIONS: The immediate and mid term outcomes of pulmonary ventricle bypass operations can have excellent results. From our point of view there has been an improvement, namely in the use of the extracardiac conduit technique in the 2nd stage of the Fontan operation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: A growing body of evidence shows the prognostic value of oxygen uptake efficiency slope (OUES), a cardiopulmonary exercise test (CPET) parameter derived from the logarithmic relationship between O(2) consumption (VO(2)) and minute ventilation (VE) in patients with chronic heart failure (CHF). OBJECTIVE: To evaluate the prognostic value of a new CPET parameter - peak oxygen uptake efficiency (POUE) - and to compare it with OUES in patients with CHF. METHODS: We prospectively studied 206 consecutive patients with stable CHF due to dilated cardiomyopathy - 153 male, aged 53.3±13.0 years, 35.4% of ischemic etiology, left ventricular ejection fraction 27.7±8.0%, 81.1% in sinus rhythm, 97.1% receiving ACE-Is or ARBs, 78.2% beta-blockers and 60.2% spironolactone - who performed a first maximal symptom-limited treadmill CPET, using the modified Bruce protocol. In 33% of patients an cardioverter-defibrillator (ICD) or cardiac resynchronization therapy device (CRT-D) was implanted during follow-up. Peak VO(2), percentage of predicted peak VO(2), VE/VCO(2) slope, OUES and POUE were analyzed. OUES was calculated using the formula VO(2) (l/min) = OUES (log(10)VE) + b. POUE was calculated as pVO(2) (l/min) / log(10)peakVE (l/min). Correlation coefficients between the studied parameters were obtained. The prognosis of each variable adjusted for age was evaluated through Cox proportional hazard models and R2 percent (R2%) and V index (V6) were used as measures of the predictive accuracy of events of each of these variables. Receiver operating characteristic (ROC) curves from logistic regression models were used to determine the cut-offs for OUES and POUE. RESULTS: pVO(2): 20.5±5.9; percentage of predicted peak VO(2): 68.6±18.2; VE/VCO(2) slope: 30.6±8.3; OUES: 1.85±0.61; POUE: 0.88±0.27. During a mean follow-up of 33.1±14.8 months, 45 (21.8%) patients died, 10 (4.9%) underwent urgent heart transplantation and in three patients (1.5%) a left ventricular assist device was implanted. All variables proved to be independent predictors of this combined event; however, VE/VCO2 slope was most strongly associated with events (HR 11.14). In this population, POUE was associated with a higher risk of events than OUES (HR 9.61 vs. 7.01), and was also a better predictor of events (R2: 28.91 vs. 22.37). CONCLUSION: POUE was more strongly associated with death, urgent heart transplantation and implantation of a left ventricular assist device and proved to be a better predictor of events than OUES. These results suggest that this new parameter can increase the prognostic value of CPET in patients with CHF.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Para conseguir responder às exigências atuais dos mercados, as indústrias necessitam de ser flexíveis, ou seja, é necessário terem a capacidade de adaptar o seu funcionamento e os seus produtos às alterações que se sucedem. Como forma de responder a este facto, o funcionamento da empresa assenta numa produção flexível para conseguir que os seus produtos que abranjam diferente o maior número possível de clientes. No entanto esta metodologia tem apresentado alguns problemas na sua implementação, por isso com o objetivo de obter uma produção mais eficaz e eficiente, a empresa tem canalizado esforços para a melhoria contínua das linhas de montagem. O trabalho desenvolvido na FUTE está enquadrado com a melhoria contínua e visa o processo de abastecimento dos diversos materiais necessários para a produção, característica fundamental para que as linhas possam produzir de forma contínua. Este estudo iniciou-se por analisar o método de abastecimento e identificar os seus problemas e causas, para que posteriormente com o auxílio dos conhecimentos adq uiridos, fosse possível conceber soluções. Os resultados apresentados neste trabalho demonstram que as melhorias implementadas a nível de organização de armazéns, métodos de trabalho e meios de transporte de materiais permitem diminuir o tempo e os recursos necessários durante o processo de abastecimento, além de melhorar condições de trabalho dos operários.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Influenza surveillance is usually based on nationally organized sentinel networks of physicians and on hospital reports. This study aimed to test a different report system, based on parents' phone contact to the research team and in home collection of samples by a dedicated team. The identification of influenza and other respiratory viruses in children who attended a Hospital Emergency Department was also recorded. Real-time PCR and reverse transcription PCR were performed for influenza A and B, parainfluenza 1-4, adenovirus, human metapneumovirus, respiratory syncytial virus A and B, rhinovirus, enterovirus, group 1 coronaviruses, group 2 coronaviruses, and human bocavirus. One hundred children were included, 64 from the day care centers and 36 from the Hospital. Overall, 79 samples were positive for at least one respiratory virus. Influenza A (H3) was the virus most frequently detected: 25 cases, 20 of these in children under 5 years of age (ten from day care centers and ten who went to the hospital) which was higher than those reported by the National Influenza Surveillance Programme for this age. CONCLUSION: The results obtained in this study suggest that a surveillance system based on parents' reports could complement the implanted system of the National Influenza Surveillance Programme.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Arte e Ciência do Vidro

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMO - Com o aumento da esperança de vida e das doenças crónicas, cada vez se tem implantado mais cardioversores-desfibrilhadores (CDI) para prevenção de morte súbita. O aumento exponencial no número de implantes aumenta o número de seguimentos dos dispositivos, sobrecarregando os profissionais de saúde e comprometendo a qualidade dos serviços prestados. Segundo as recomendações internacionais, um CDI deverá ser vigiado a cada 3 meses, o que perfaz 4 consultas por ano/doente no mínimo, se não existirem episódios de “choques” ou “descompensações” clínicas, e mensalmente quando é atingido o indicador de substituição electiva do gerador. A evolução da tecnologia, de algoritmos, visualização de episódios e terapias requer recursos técnicos e humanos diferenciados e um gasto de tempo considerável no seguimento. Em países como os Estados Unidos da América, em que os doentes têm de percorrer distâncias muito grandes para aceder aos cuidados de saúde, tornou-se preemente a necessidade de um sistema de vigilância alternativo. Nesse sentido, e usando o conceito da telemedicina, foi criado o seguimento/monitorização à distância de dispositivos cardíacos. Este reduz os custos em consultas, deslocações e recursos humanos, uma vez que contempla apenas uma consulta presencial por ano. Por outro lado, aumenta a segurança do doente com a monitorização periódica e a criação de alarmes, permitindo uma assistência de qualidade e intervenção adequada imediata. Aproveitando as vantagens que este tipo de sistema de transmissão remota oferece, procedeu-se no meu serviço, à distribuição inicial de 62 comunicadores a doentes portadores de CDI´s ou com Ressincronizadores Cardíacos (TRC´s1). Apesar de ser considerada uma melhoria na qualidade dos serviços prestados, é também uma mudança importante na metodologia da consulta feita até aqui. Segundo vários autores, a avaliação da qualidade dos cuidados em saúde está intrinsecamente ligada ao grau de satisfação dos doentes com esses serviços, ou seja, à relação entre as suas expectativas e os resultados percebidos por eles, sendo considerado um importante indicador de qualidade dos serviços. Com este trabalho, pretende-se avaliar a percepção dos doentes face ao novo seguimento em termos de aceitação, satisfação, validade, segurança e confiança no novo sistema. Se este mantém os mesmos padrões de qualidade que o seguimento presencial. Trata-se de um estudo transversal com uma componente retrospectiva de avaliação da nova metodologia de consulta à distância. Para tal, foi elaborado um questionário, que foi aplicado a 40 doentes (17,5% do género feminino e 82,5% do género masculino; média de idades de 65 anos) que constituíram a amostra do estudo. Verificou-se uma média de 5 anos de tempo de implante do CDI. Dos dados obtidos, é de realçar que 70% dos inquiridos estão satisfeitos e 30% estão muito satisfeitos com esta nova metodologia de consulta e cerca 67,4% prefere a consulta à distância. Quando solicitados para comparar a qualidade do serviço prestado entre as duas consultas, 65% respondeu igual e 27,5% melhor. Todos os inquiridos responderam ter confiança e segurança com o sistema de consulta à distância. Cerca de 87,5% dos inquiridos vê-se mesmo a continuar com este tipo de consulta. Os resultados obtidos são bastante satisfatórios no que diz respeito à transição do modo como a consulta de CDI´s é feita. Reflectem também que a tecnologia não é necessariamente uma barreira no acesso aos profissionais de saúde, desde que suportada por algum contacto directo (telefone e através de uma consulta presencial por ano). 1 TRC – Terapia de Ressincronização Cardíaca

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes the process and problems that had to be faced during the elaboration of a digital interactive narrative for the Instory project (http://img.di.fct.unl.pt/InStory/) implanted in «Quinta da Regaleira», Sintra, Portugal, and classified as World Heritage by Unesco. It also explores some of the practical and theoretical issues in what regards the literary terminology and strategies involved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to evaluate the Chagas Disease Control Program which has operated since 1982 in the municipality of Berilo in the Jequitinhonha Valley, Minas Gerais, Brazil, based on evaluation of 5,242 domiciliary units (DUs) and 7,807 outbuildings over an eight-year period of epidemiological surveillance implanted in 1997. A total of 391 triatomines (280 Panstrongylus megistus and 111 Triatoma pseudomaculata) were captured, indicating the continued predominance of the former species. However, Triatoma pseudomaculata is clearly becoming more important in this region, with intradomiciliary colonies being detected in recent years. Entomological parameters, such as dispersion (17%) and intradomiciliary infestation (0.15%) indices, are compatible with the results of the epidemiological surveillance. The majority of DUs were of construction type A (plaster over bricks) or C (plaster over adobe). Twenty-five percent of the inhabitants of the DUs infested by triatomines were reactive in ELISA, IHA and IIF tests for Trypanosoma cruzi antigens.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Infection is the leading complication of long-term central venous catheters, and its incidence may vary according to catheter type. The objective of this study was to compare the frequency and probability of infection between two types of long-term intravenous devices. METHODS: Retrospective study in 96 onco-hematology patients with partially implanted catheters (n = 55) or completely implanted ones (n = 42). Demographic data and catheter care were similar in both groups. Infection incidence and infection-free survival were used for the comparison of the two devices. RESULTS: In a median follow-up time of 210 days, the catheter-related infection incidence was 0.2102/100 catheter-days for the partially implanted devices and 0.0045/100 catheter-days for the completely implanted devices; the infection incidence rate was 46.7 (CI 95% = 6.2 to 348.8). The 1-year first infection-free survival ratio was 45% versus 97%, and the 1-year removal due to infection-free survival ratio was 42% versus 97% for partially and totally implanted catheters, respectively (P <.001 for both comparisons). CONCLUSION: In the present study, the infection risk was lower in completely implanted devices than in partially implanted ones.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

 In orthopaedics, the management and treatment of osteochondral (OC) defects remains an ongoing clinical challenge. Autologous osteochondral mosaicplasty has been used as a valid option for OC treatments although donor site morbidity remains a source of concern [1]. Engineering a whole structure capable of mimicking different tissues (cartilage and subchondral bone) in an integrated manner could be a possible approach to regenerate OC defects. In our group we have been proposing the use of bilayered structures to regenerate osteochondral defects [2,3]. The present study aims to investigate the pre-clinical performance of bilayered hydrogels and spongy-like hydrogels in in vivo  models (mice and rabbit, respectively), in both subcutaneous and orthotopic models. The bilayered structures were produced from Low Acyl Gellan Gum (LAGG) from Sigma-Aldrich, USA. Cartilage-like layers were obtained from a 2wt% LAGG solution. The bone-like layers were made of 2wt% LAGG with incorporation of hydroxyapatite at 20% and 30% (w/v). Hydrogels and spongy-like were subcutaneouly implanted in mice to evaluate the inflammatory response. Then, OC defects were induced in rabbit knee to create a critical size defect (4 mm diameter and 5 mm depth), and then hydrogels and sponges implanted. Both structures followed different processing methods. The hydrogels were injected allowing in situ  crosslinking. Unlike, the spongy-like were pre-formed by freeze-drying. The studies concerning subcutaneous implantation and critical size OC defect were performed for 2 and 4 weeks time, respectively. Cellular behavior and inflammatory responses were assessed by means of histology staining and biochemical function and matrix deposition by immunohistochemistry. Additionally, both OC structures stability and new cartilage and bone formation were evaluated by using vivo- computed tomography (Scanco 80). The results showed no acute inflammatory response for both approaches. New tissue formation and integration in the adjacent tissues were also observed, which present different characteristic behaviors when comparing hydrogels and sponges response. As future insights, a novel strategy for regeneration of OC defects can be designed encompassing both, hydrogels and spongy-like structures and cellular approaches. References: 1. Espregueira-Mendes J. et al. Osteochondral transplantation using autografts from the upper tibio-fibular joint for the treatment of knee cartilage lesions. Knee Surgery, Sports Traumatology, Arthroscopy 20,1136, 2012. 2. Oliveira JM. et al, Novel hydroxyapatite/chitosan bilayered scaffold for osteochondral tissue-engineering applications: Scaffold design and its performance when seeded with goat bone marrow stromal cells. Biomaterials 27, 6123, 2006. 3. Pereira D R. et al. Gellan Gum-Based Hydrogel Bilayered Scaffolds for Osteochondral Tissue Engineering. Key Engineering Materials 587, 255, 2013.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bioactive glass nanoparticles (BGNPs) promote an apatite surface layer in physiologic conditions that lead to a good interfacial bonding with bone.1 A strategy to induce bioactivity in non-bioactive polymeric biomaterials is to incorporate BGNPs in the polymer matrix. This combination creates a nanocomposite material with increased osteoconductive properties. Chitosan (CHT) is a polymer obtained by deacetylation of chitin and is biodegradable, non-toxic and biocompatible. The combination of CHT and the BGNPs aims at designing biocompatible spheres promoting the formation of a calcium phosphate layer at the nanocomposite surface, thus enhancing the osteoconductivity behaviour of the biomaterial. Shape memory polymers (SMP) are stimuli-responsive materials that offer mechanical and geometrical action triggered by an external stimulus.2 They can be deformed and fixed into a temporary shape which remains stable unless exposed to a proper stimulus that triggers recovery of their original shape. This advanced functionality makes such SMPs suitable to be implanted using minimally invasive surgery procedures. Regarding that, the inclusion of therapeutic molecules becomes attractive.  We propose the synthesis of shape memory bioactive nanocomposite spheres with drug release capability.3   1.  L. L. Hench, Am. Ceram. Soc. Bull., 1993, 72, 93-98. 2.  A. Lendlein and S. Kelch, Angew Chem Int Edit, 2002, 41, 2034-2057. 3.  Ã . J. Leite, S. G. Caridade and J. F. Mano, Journal of Non-Crystalline Solids (in Press)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In tissue engineering of cartilage, polymeric scaffolds are implanted in the damaged tissue and subjected to repeated compression loading cycles. The possibility of failure due to mechanical fatigue has not been properly addressed in these scaffolds. Nevertheless, the macroporous scaffold is susceptible to failure after repeated loading-unloading cycles. This is related to inherent discontinuities in the material due to the micropore structure of the macro-pore walls that act as stress concentration points. In this work, chondrogenic precursor cells have been seeded in Poly-ε-caprolactone (PCL) scaffolds with fibrin and some were submitted to free swelling culture and others to cyclic loading in a bioreactor. After cell culture, all the samples were analyzed for fatigue behavior under repeated loading-unloading cycles. Moreover, some components of the extracellular matrix (ECM) were identified. No differences were observed between samples undergoing free swelling or bioreactor loading conditions, neither respect to matrix components nor to mechanical performance to fatigue. The ECM did not achieve the desired preponderance of collagen type II over collagen type I which is considered the main characteristic of hyaline cartilage ECM. However, prediction in PCL with ECM constructs was possible up to 600 cycles, an enhanced performance when compared to previous works. PCL after cell culture presents an improved fatigue resistance, despite the fact that the measured elastic modulus at the first cycle was similar to PCL with poly(vinyl alcohol) samples. This finding suggests that fatigue analysis in tissue engineering constructs can provide additional information missed with traditional mechanical measurements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Polymeric scaffolds used in regenerative therapies are implanted in the damaged tissue and subjected to repeated loading cycles. In the case of articular cartilage engineering, an implanted scaffold is typically subjected to long term dynamic compression. The evolution of the mechanical properties of the scaffold during bioresorption has been deeply studied in the past, but the possibility of failure due to mechanical fatigue has not been properly addressed. Nevertheless, the macroporous scaffold is susceptible to failure after repeated loading-unloading cycles. In this work fatigue studies of polycaprolactone scaffolds were carried by subjecting the scaffold to repeated compression cycles in conditions simulating the scaffold implanted in the articular cartilage. The behaviour of the polycaprolactone sponge with the pores filled with a poly(vinyl alcohol) gel simulating the new formed tissue within the pores was compared with that of the material immersed in water. Results were analyzed with Morrow’s criteria for failure and accurate fittings are obtained just up to 200 loading cycles. It is also shown that the presence of poly(vinyl alcohol) increases the elastic modulus of the scaffolds, the effect being more pronounced with increasing the number of freeze/thawing cycles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

METHODS: Refractive lens exchange was performed with implantation of an AT Lisa 839M (trifocal) or 909MP (bifocal toric) IOL, the latter if corneal astigmatism was more than 0.75 diopter (D). The postoperative visual and refractive outcomes were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. A control group of eyes in which a Tecnis ZCB00 1-piece monofocal IOL was implanted had the same examinations. RESULTS: A trifocal or bifocal toric IOL was implanted in 66 eyes. The control IOL was implanted in 18 eyes. All 3 groups obtained a significant improvement in uncorrected distance visual acuity (UDVA) (P < .001) and corrected distance visual acuity (CDVA) (P Z .001). The mean uncorrected near visual acuity (UNVA) was 0.123 logMAR with the trifocal IOL and 0.130 logMAR with the bifocal toric IOL. The residual refractive cylinder was less than 1.00 D in 86.7% of cases with the toric IOL. The mean light-distortion index was significantly higher in the multifocal IOL groups than in the monofocal group (P < .001), although no correlation was found between the light-distortion index and CDVA. CONCLUSIONS: The multifocal IOLs provided excellent UDVA and functional UNVA despite increased light-distortion indices. The light-distortion analyzer reliably quantified a subjective component of vision distinct from visual acuity; it may become a useful adjunct in the evaluation of visual quality obtained with multifocal IOLs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hind-limb ischemia has been used in type 1 diabetic mice to evaluate treatments for peripheral arterial disease or mechanisms of vascular impairment in diabetes [1]. Vascular deficiency is not only a pathophysiological condition, but also an obvious circumstance in tissue regeneration and in tissue engineering and regenerative medicine (TERM) strategies. We performed a pilot experiment of hind-limb ischemia in streptozotocin(STZ)-induced type 1 diabetic mice to hypothesise whether diabetes influences neovascularization induced by biomaterials. The dependent variables included blood flow and markers of arteriogenesis and angiogenesis. Type 1 diabetes was induced in 8-week-old C57BL/6 mice by an i.p. injection of STZ (50 mg/kg daily for 5 days). Hind-limb ischemia was created under deep anaesthesia and the left femoral artery and vein were isolated, ligated, and excised. The contralateral hind limb served as an internal control within each mouse. Non-diabetic ischaemic mice were used as experiment controls. At the hind-limb ischemia surgical procedure, different types of biomaterials were placed in the blood vessels gap. Blood flow was estimated by Laser Doppler perfusion imager, right after surgery and then weekly. After 28 days of implantation, surrounding muscle was excised and evaluated by histological analysis for arteriogenesis and angiogenesis. The results showed that implanted biomaterials were promote faster restoration of blood flow in the ischemic limbs and improved neovascularization in the diabetic mice. Therefore, we herein demonstrate that the combined model of hind-limb ischemia in type 1 diabetes mice is suitable to evaluate the neovascularization potential of biomaterials and eventually tissue engineering constructs.