621 resultados para IMINOPROTON RESONANCES


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The recently measured inclusive electron-proton cross section in the nucleon resonance region, performed with the CLAS detector at the Thomas Jefferson Laboratory, has provided new data for the nucleon structure function F2 with previously unavailable precision. In this paper we propose a description of these experimental data based on a Regge-dual model for F2. The basic inputs in the model are nonlinear complex Regge trajectories producing both isobar resonances and a smooth background. The model is tested against the experimental data, and the Q2 dependence of the moments is calculated. The fitted model for the structure function (inclusive cross section) is a limiting case of the more general scattering amplitude equally applicable to deeply virtual Compton scattering. The connection between the two is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The interaction of the low-lying pseudoscalar mesons with the ground-state baryons in the charm sector is studied within a coupled-channel approach using a t-channel vector-exchange driving force. The amplitudes describing the scattering of the pseudoscalar mesons off the ground-state baryons are obtained by solving the Lippmann-Schwinger equation. We analyze in detail the effects of going beyond the t=0 approximation. Our model predicts the dynamical generation of several open-charm baryon resonances in different isospin and strangeness channels, some of which can be clearly identified with recently observed states.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Smuggling dissolved drugs, especially cocaine, in bottled liquids is a problem at borders nowadays. Common fluoroscopy of packages at the border cannot detect contaminated liquids. To find a dissolved drug, an immunological test using a drug-test panel has to be performed. This means that a control sample of the cargo must be opened to perform the test. As it is not possible to open all boxes, and as smugglers hide the drugcontaining boxes between regularly filled boxes, contaminated cargos can be overlooked. Investigators sometimes cannot perform the drug-test panel because they try not to arouse the smugglers' suspicion in order to follow the cargo and to find the recipient. Aims: The objective of our studies was to define non-invasive examination techniques to investigate cargos that are suspicions to contain dissolved cocaine without leaving traces on the samples. We examined vessels containing cocaine by radiological cross-section techniques such as multidetector computed tomography (MDCT) and magnetic resonance spectroscopy (MRS). Methods: In a previous study, we examined bottles of wine containing dissolved cocaine in different quantities using an MDCT unit. To distinguish between bottles containing red wine and those where cocaine was solved in the wine, cross sectional 2D-images have been reconstructed and the absorption of X-rays was quantified by measuring the mean density of the liquid inside the bottles. In our new study, we investigated phantoms containing cocaine dissolved in water with or without ethanol as well as cocaine dissolved in different sorts of commercially available wine by the use of a clinical magnetic resonance unit (3 tesla). To find out if dissolved cocaine could be detected, magnetic resonance spectroscopy (1H MRS) was performed. Results: By using a MDCT-unit and measuring the mean attenuation of X-rays, it is possible to distinguish weather substances are dissolved in a liquid or not, if a comparative liquid without any solutions is available. The increase of the mean density indicates the presence of dissolved substances without the possibility to identify the substance. By using magnetic resonance spectroscopy, dissolved cocaine can be clearly identified because it produces distinctive resonances in the spectrum. In contrast to MDCT, this technique shows a high sensitivity (detection of 1 mM cocaine in wine). Conclusions: Cross-sectional imaging techniques such as MDCT and MRS appropriated to examine cargos that are suspicious to contain dissolved cocaine. They allow to perform non-invasive investigations without leaving any trace on the cargo. While an MDCT scan can detect dissolved substances in liquids, identification of cocaine can be obtained by MR-spectroscopy. Acknowledgment: This work was supported by the Centre d'Imagerie BioMédicale (CIBM) of the University of Lausanne (UNIL), the Swiss Federal Institute of Technology Lausanne (EPFL), the University of Geneva (UniGe), the Centre Hospitalier Universitaire Vaudois (CHUV), the Hôpitaux Universitaire de Genève (HUG) and the Leenaards and the Jeantet Foundations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The phenomenon of resonant activation of a Brownian particle over a fluctuating barrier is revisited. We discuss the important distinctions between barriers that can fluctuate among up and down configurations, and barriers that are always up but that can fluctuate among different heights. A resonance as a function of the barrier fluctuation rate is found in both cases, but the nature and physical description of these resonances is quite distinct. The nature of the resonances, the physical basis for the resonant behavior, and the importance of boundary conditions are discussed in some detail. We obtain analytic expressions for the escape time over the barrier that explicitly capture the minima as a function of the barrier fluctuation rate, and show that our analytic results are in excellent agreement with numerical results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The recent observation of steps at regular intervals of magnetic field in the hysteresis loops of oriented crystals of the spin-10 molecular magnet Mn12O12(CH3COO)16(H2O)4 has been attributed to resonant tunneling between spin states. Here, we investigate the effect on the relaxation rate of applying the magnetic field at an angle with respect to the easy axis of magnetization. We find that the position of the resonances is independent of the transverse component of the field, and is determined solely by the longitudinal component. On the other hand, a transverse field significantly increases the relaxation rate, both on and off resonance. We discuss classical and quantum mechanical interpretations of this effect

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The relaxivity of commercially available gadolinium (Gd)-based contrast agents was studied for X-nuclei resonances with long intrinsic relaxation times ranging from 6 s to several hundred seconds. Omniscan in pure 13C formic acid had a relaxivity of 2.9 mM(-1) s(-1), whereas its relaxivity on glutamate C1 and C5 in aqueous solution was approximately 0.5 mM(-1) s(-1). Both relaxivities allow the preparation of solutions with a predetermined short T1 and suggest that in vitro substantial sensitivity gains in their measurement can be achieved. 6Li has a long intrinsic relaxation time, on the order of several minutes, which was strongly affected by the contrast agents. Relaxivity ranged from approximately 0.1 mM(-1) s(-1) for Omniscan to 0.3 for Magnevist, whereas the relaxivity of Gd-DOTP was at 11 mM(-1) s(-1), which is two orders of magnitude higher. Overall, these experiments suggest that the presence of 0.1- to 10-microM contrast agents should be detectable, provided sufficient sensitivity is available, such as that afforded by hyperpolarization, recently introduced to in vivo imaging.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite obvious improvements in spectral resolution at high magnetic field, the detection of 13C labeling by 1H-[13C] NMR spectroscopy remains hampered by spectral overlap, such as in the spectral region of 1H resonances bound to C3 of glutamate (Glu) and glutamine (Gln), and C6 of N-acetylaspartate (NAA). The aim of this study was to develop, implement, and apply a novel 1H-[13C] NMR spectroscopic editing scheme, dubbed "selective Resonance suppression by Adiabatic Carbon Editing and Decoupling single-voxel STimulated Echo Acquisition Mode" (RACED-STEAM). The sequence is based on the application of two asymmetric narrow-transition-band adiabatic RF inversion pulses at the resonance frequency of the 13C coupled to the protons that need to be suppressed during the mixing time (TM) period, alternating the inversion band downfield and upfield from the 13C resonance on odd and even scans, respectively, thus suppressing the detection of 1H resonances bound to 13C within the transition band of the inversion pulse. The results demonstrate the efficient suppression of 1H resonances bound to C3 of Glu and Gln, and C4 of Glu, which allows the 1H resonances bound to C6 of NAA and C4 of Gln to be revealed. The measured time course of the resolved labeling into NAA C6 with the new scheme was consistent with the slow turnover of NAA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To assess the feasibility of a method based on microwave spectrometry to detect structural distortions of metallic stents in open air conditions and envisage the prospects of this approach toward possible medical applicability for the evaluation of implanted stents. Methods: Microwave absorbance spectra between 2.0 and 18.0 GHz were acquired in open air for the characterization of a set of commercial stents using a specifically design setup. Rotating each sample over 360º, 2D absorbance diagrams were generated as a function of frequency and rotation angle. To check our approach for detecting changes in stent length (fracture) and diameter (recoil), two specific tests were performed in open air. Finally, with a few adjustments, this same system provides 2D absorbance diagrams of stents immersed in a water-based phantom, this time over a bandwidth ranging from 0.2 to 1.8 GHz. Results: The authors show that metallic stents exhibit characteristic resonant frequencies in their microwave absorbance spectra in open air which depend on their length and, as a result, may reflect the occurrence of structural distortions. These resonances can be understood considering that such devices behave like dipole antennas in terms of microwave scattering. From fracture tests, the authors infer that microwave spectrometry provides signs of presence of Type I to Type IV stent fractures and allows in particular a quantitative evaluation of Type III and Type IV fractures. Recoil tests show that microwave spectrometry seems able to provide some quantitative assessment of diametrical shrinkage, but only if it involves longitudinal shortening. Finally, the authors observe that the resonant frequencies of stents placed inside the phantom shift down with respect to the corresponding open air frequencies, as it should be expected considering the increase of dielectric permittivity from air to water. Conclusions: The evaluation of stent resonant frequencies provided by microwave spectrometry allows detection and some quantitative assessment of stent fracture and recoil in open air conditions. Resonances of stents immersed in water can be also detected and their characteristic frequencies are in good agreement with theoretical estimates. Although these are promising results, further verifica tion in a more relevant phantom is required in order to foresee the real potential of this approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pienitehoisessa taajuusmuuttajassa verkkojännite tasasuunnataan yleisesti diodisillalla. Taajuusmuuttajaa kuormitettaessa diodisilta aiheuttaa sen, että verkosta otettava virta on epäsinimuotoista ja sisältää runsaasti eri kertalukujen yliaaltoja. Tällainen virta vääristää verkon jännitettä sekä aiheuttaa häviöitä, resonansseja ja toimintaepävarmuutta sähkönjakeluverkkoon liitetyissä laitteissa ja komponenteissa. Työssä on tarkasteltu pienitehoisen kolmivaiheisen taajuusmuuttajan tulovirrassa esiintyviä yliaaltoja ja keinoja niiden rajoittamiseksi. Laitevalmistajien osalta syynä aiheen tutkimiseen ja kiinnostavuuteen ovat lähinnä uudet yliaaltoja käsittelevät standardit. Työssä onkin tutustuttu tarvittavin osin standardoinnin nykytilaan sekä seurattu standardeja valmistelevien työryhmien työtä ja tätä kautta perehdytty alaa käsittelevien standardien tulevaisuudennäkymiin Euroopan Unionin alueella. Käsittely on kohdistettu kolmivaiheisiin laitteisiin. Standardi IEC 61000-3-2 asettaa yliaaltorajat ammattikäyttöön tarkoitetuille laitteille, kun laitteen tuloteho on korkeintaan 1 kW. Tällä tehoalueella riittää kolmivaihelaitteille kuristimilla suoritettu passiivinen suodatus täyttämään asetetut viranomaisvaatimukset. Tähän liittyen on suunniteltu kolmivaihekuristin, joka on tarkoitettu käytettäväksi taajuusmuuttajasarjan lisävarusteena tehoalueella 0.12…2.2 kW.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe a relation between the symmetry energy coefficients csym(ρ) of nuclear matter and asym(A) of finite nuclei that accommodates other correlations of nuclear properties with the low-density behavior of csym(ρ). Here, we take advantage of this relation to explore the prospects for constraining csym(ρ) of systematic measurements of neutron skin sizes across the mass table, using as example present data from antiprotonic atoms. The found constraints from neutron skins are in harmony with the recent determinations from reactions and giant resonances.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To assess the feasibility of a method based on microwave spectrometry to detect structural distortions of metallic stents in open air conditions and envisage the prospects of this approach toward possible medical applicability for the evaluation of implanted stents. Methods: Microwave absorbance spectra between 2.0 and 18.0 GHz were acquired in open air for the characterization of a set of commercial stents using a specifically design setup. Rotating each sample over 360º, 2D absorbance diagrams were generated as a function of frequency and rotation angle. To check our approach for detecting changes in stent length (fracture) and diameter (recoil), two specific tests were performed in open air. Finally, with a few adjustments, this same system provides 2D absorbance diagrams of stents immersed in a water-based phantom, this time over a bandwidth ranging from 0.2 to 1.8 GHz. Results: The authors show that metallic stents exhibit characteristic resonant frequencies in their microwave absorbance spectra in open air which depend on their length and, as a result, may reflect the occurrence of structural distortions. These resonances can be understood considering that such devices behave like dipole antennas in terms of microwave scattering. From fracture tests, the authors infer that microwave spectrometry provides signs of presence of Type I to Type IV stent fractures and allows in particular a quantitative evaluation of Type III and Type IV fractures. Recoil tests show that microwave spectrometry seems able to provide some quantitative assessment of diametrical shrinkage, but only if it involves longitudinal shortening. Finally, the authors observe that the resonant frequencies of stents placed inside the phantom shift down with respect to the corresponding open air frequencies, as it should be expected considering the increase of dielectric permittivity from air to water. Conclusions: The evaluation of stent resonant frequencies provided by microwave spectrometry allows detection and some quantitative assessment of stent fracture and recoil in open air conditions. Resonances of stents immersed in water can be also detected and their characteristic frequencies are in good agreement with theoretical estimates. Although these are promising results, further verifica tion in a more relevant phantom is required in order to foresee the real potential of this approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A study of D +π−, D 0π+ and D ∗+π− final states is performed using pp collision data, corresponding to an integrated luminosity of 1.0 fb−1, collected at a centre-of-mass energy of 7 TeV with the LHCb detector. The D 1(2420)0 resonance is observed in the D ∗+π− final state and the D∗2(2460) resonance is observed in the D +π−, D 0π+ and D ∗+π− final states. For both resonances, their properties and spin-parity assignments are obtained. In addition, two natural parity and two unnatural parity resonances are observed in the mass region between 2500 and 2800 MeV. Further structures in the region around 3000 MeV are observed in all the D ∗+π−, D +π− and D 0π+ final states.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stigmaphyllom paralias is a herb belonging to the family Malpighiaceae that occurs in sand soil of brazilian " restinga". This is the first report regarding phytochemical study with this species. The hexane extract of the aerial parts of plant afforded the triterpenes friedelin, lupenone, 3-oxo-alpha-amirin and 3-oxo-beta-amirin, the mixture of alpha-amirinyl palmitate and stearate, lupeol and 3,4-seco-friedelan-3-oic acid. The AcOEt extract yielded the flavonoid luteolin-7-rutinoside. All compounds were characterized by analysis of spectrometric data and the fatty acids esterified with alpha-amirine were identified by GC/MS of methyl derivatives of transesterified products . This is the first natural occurence of 3,4-seco-friedelan-3-oic acid and the 13C NMR spectral data were inequivocally assigned by two-dimensional techniques. This work also permitted to correct the 13C NMR resonances attributed to methyl groups C-26 and C-27 of fridelin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A detailed NMR (¹H , COSY, ROESY) spectroscopic study of complexation of enalapril maleate with beta-cyclodextrin was carried out. The ¹H NMR spectrum of enalapril maleate confirmed the existence of cis-trans equilibrium in solution, possibly due to hindered rotation along the amide bond. The cis-trans ratio remained almost the same in the presence of beta-cyclodextrin but in one case it was found significantly different which suggests a catalytic role of beta-cyclodextrin in the isomerization. ¹H NMR titration studies confirmed the formation of an enalapril-beta-cyclodextrin inclusion complex as evidenced by chemical shift variations in the proton resonances of both the host and the guest. The stoichiometry of the complex was determined to be 2:1 (guest: host). The mode of penetration of the guest into the beta-cyclodextrin cavity as well as the structure of the complex were established using ROESY spectroscopy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report controlled ignition of magnetization reversal avalanches by surface acoustic waves in a single crystal of Mn12 acetate. Our data show that the speed of the avalanche exhibits maxima on the magnetic field at the tunneling resonances of Mn12. Combined with the evidence of magnetic deflagration in Mn12 acetate [Y. Suzuki et al., Phys. Rev. Lett. 95, 147201 (2005)], this suggests a novel physical phenomenon: deflagration assisted by quantum tunneling.