988 resultados para Hospital Bed Capacity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The residence time distribution and mean residence time of a 10% sodium bicarbonate solution that is dried in a conventional spouted bed with inert bodies were measured with the stimulus-response method. Methylene blue was used as a chemical tracer, and the effects of the paste feed mode, size distribution of the inert bodies, and mean particle size on the residence times and dried powder properties were investigated. The results showed that the residence time distributions could be best reproduced with the perfect mixing cell model or N = 1 for the continuous stirred tank reactor in a series model. The mean residence times ranged from 6.04 to 12.90 min and were significantly affected by the factors studied. Analysis of variance on the experimental data showed that mean residence times were affected by the mean diameter of the inert bodies at a significance level of 1% and by the size distribution at a level of 5%. Moreover, altering the paste feed from dripping to pneumatic atomization affected mean residence time at a 5% significance level. The dried powder characteristics proved to be adequate for further industrial manipulation, as demonstrated by the low moisture content, narrow range of particle size, and good flow properties. The results of this research are significant in the study of the drying of heat-sensitive materials because it shows that by simultaneously changing the size distribution and average size of the inert bodies, the mean residence times of a paste can be reduced by half, thus decreasing losses due to degradation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this research was to perform a stability testing of spray- and spouted bed-dried extracts of Passiflora alata Dryander (Passion flower) under stress storage conditions. Spouted bed- and spray-dried extracts were characterized by determination of the average particle diameter (dP), apparent moisture content (XP), total flavonoid content (TF), and vitexin content. Smaller and more irregular particles were generated by the spouted bed system due to a higher attrition rate (surface erosion) inside the dryer. The SB dryer resulted in an end product with higher concentration of flavonoids (approximate to 10%) and lower moisture content (1.6%, dry basis) than the spray dryer, even with both dryers working at similar inlet drying air temperature and ratio between the extract feed flow rate to drying air flow rate (Ws/Wg). Samples of the spouted bed- and spray-dried extracts were stored at two different temperatures (34 and 45 degrees C) and two different relative humidities (52 and 63% RH for 34 degrees C; 52 and 60% RH for 45 degrees C) in order to perform the stability testing. The dried extracts were stored for 28 days and were analyzed every 4 days. The flavonoid vitexin served as the marker compound, which was assayed during the storage period. Results revealed shelf lives ranging from 9 to 184 days, depending on the drying process and storage conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work evaluates the feasibility of the draft-tube spouted bed for drying of herbal extract. Drying runs were carried out according to a central composite design in a conical-cylindrical draft-tube spouted bed. The variables studied were the percentage of the drying aid (ADJ), the drying gas flow rate relative to gas flow at minimum spouting (Q/Q(ms)), and the flow rate of extract fed to the system relative to the spouting gas flow rate W(s)/W(g)). Colloidal silicon dioxide was the drying aid used in order to improve drying performance. Statistical analysis of the effects of processing parameters on product recovery, product accumulation in the bed, and product properties permitted the identification of parameters presenting significant effects on drying. Optimized drying conditions were related to experimental parameters as follow: high levels of the percentage of drying adjuvant (ADJ), high airflow rate relative to minimum spouting (Q/Q(ms)), and low values of the feed flow rate of the extract relative to the gas flow rate (W(s)/W(g)).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The feasibility of detecting instability in wet spouted beds via pressure fluctuation (PF) time-series analyses was investigated. Experiments were carried out in a cylindrical Plexiglas column of diameter 150 mm with a conical base of internal angle 60 degrees, an inlet orifice diameter of 25 mm and glass beads of diameter 2.4 mm. Transducers at several axial positions measured PF time series with incremental addition of aqueous sucrose solutions of different concentrations. Liquid addition affected the spouted bed dynamics, causing irregular spouting, increased voidage in the annulus, increased fountain height, irregular annulus height, channelling, agglomeration, and adhesion of particles to the column walls. Autocorrelations indicated the appearance of periodicities in the PF signals with increasing sucrose addition. Dominant peaks in power-spectral density developed at low frequencies with changing system dynamics. The results indicate that PF signals furnish relevant information on system dynamics, useful for monitoring and control of spouted bed operations such as particle coating and drying of paste-like materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The feasibility of characterizing the dynamics of a spouted bed based on acoustic emission (AE) signals is evaluated. Acoustic emission signals were measured in a semi-cylindrical Plexiglas column of diameter 150 mm and height 1000 mm with a conical base of internal angle 60 degrees and 25 mm inlet orifice diameter. Data were obtained for U/U(ms), from 0.3 to 2.0, static bed height from 250 to 500 mm, and glass beads of diameter 1.2 and 2.4 mm. AE signals reflected the effects of particle size and U/U(ms), but in general were insensitive to bed depth, even when there were drastic changes in spouting flow patterns. The results indicate that the AE signals were insensitive to the spouted bed hydrodynamics for the conditions studied. Overall, it appears that the AE analysis is unlikely to be a suitable technique for discriminating spouted bed flow regimes, at least for the range of frequencies and operating conditions investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study was designed to determine the prevalence and extended-spectrum beta-lactamase (ESBL) types in clinical isolates of Klebsiella spp. at a university hospital located in the Brazilian southern region (Ribeirao Preto, Sao Paulo) as well as their antibiotic susceptibility and genetic profiles. This study included 147 non-repeat Klebsiella spp. isolates collected from January to June 2000, of which 23 K. pneumoniae and 8 K. oxytoca were selected as ESBL producers by using the Oxoid combination disk method and Etest ESBL strip. beta-lactamases were characterized by IEF, PCR and sequencing assays using primers for ESBL genes. Antibiotic susceptibility was evaluated by MicroScan system. Dissemination of two major clones of ESBL-producing Klebsiella spp. occurred in the hospital. According to the results obtained in this study there was a clonal spread of CTX-M-producing K. oxytoca in five clinics and dissemination of ESBL-producing K. pneumoniae in the nursery and pediatrics wards.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purposes of this study were to evaluate in vitro the influence of different frequencies of Er:YAG laser on the human dentin caries removal capacity. Thirty fragments obtained from third molars were randomly assigned into three groups (n = 10) according to the laser frequency used: 4, 6, and 10 Hz. The caries lesion (+/-1 mm deep) was induced before the irradiation by S. mutans cultures for 6 weeks. The specimens of all groups were irradiated with 200 mJ of energy in noncontact and focused mode under constant refrigeration (water flow: 2.5 mL/min). Quantitative analysis of the caries removal was performed by DIAGNOdent (TM) and the Axion Vision (TM) software. Qualitative analysis was performed by Scanning electron microscope (SEM) and light microscope (LM). Data were analyzed by ANOVA and Fishers` tests. The DIAGNOdent (TM) revealed that the caries removal was similar with 4 and 6 Hz and was superior with 10 Hz (P < 0.05). The analysis with Axion Vision (TM) software revealed that the caries removal was similar with 6 and 10 Hz and the 4 Hz group promoted the lowest caries removal. Through SEM morphologic analysis, some specimens irradiated with 4 Hz presented, under the demineralized dentin, a disorganized collagenous matrix. The LM images revealed that all frequencies used promoted irregular caries removal, being observed over preparations with 6 and 10 Hz. It can be concluded that the increase of Er:YAG laser frequency provided a higher dentin caries removal without selectivity to the disorganized dentin. Microsc. Res. Tech. 74:281-286, 2011. (C) 2010 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CTX-M-encoding genes from Klebsiella spp. strains isolated in 2000 and 2006 were characterized as well as their genetic environment. CTX-M-2 variants were predominant in Klebsiella pneumoniae strains, which showed a greater variability in bla(CTX-M) genes, integrons, and plasmids in 2006 when compared to strains collected in 2000. CTX-M-9-producing Klebsiella oxytoca was identified in 2000 as clonal dissemination. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To describe an outbreak of imipenem-resistant metallo-beta-lactamase-producing Pseudomonas aeruginosa, enzyme type bla, by horizontal transmission in patients admitted to a mixed adult ICU. Methods: A case-control study was carried out, including 47 patients (cases) and 122 patients (control) admitted to the mixed ICU of a university hospital in Minas Gerais. Brazil from November 2003 to July 2005. The infection site, risk factors, mortality, antibiotic susceptibility, metallo-beta-lactamase (MBL) production, enzyme type, and clonal diversity were analyzed, Results: A temporal/spatial relationship was detected in most patients (94%), overall mortality was 55.3%, and pneumonia was the predominant infection (85%). The majority of isolates (95%) were resistant to imipenem and other antibiotics, except for polymyxin, and showed MBL production (76.7%). Only bla SPM-1 (33%) was identified in the 15 specimens analyzed. In addition, 4 clones were identified, with a predominance of clone A (61.5%) and B (23.1%). On multivariate analysis, advanced age, mechanical ventilation, tracheostomy, and previous imipenem use were significant risk factors for imipenem-resistant P. aeruginosa infection. Conclusions: Clonal dissemination of MBL-producing P. aeruginosa strains with a spatial/temporal relationship disclosed problems in the practice of hospital infection control, low adherence to hand hygiene, and empirical antibiotic use. (C) 2008 Elsevier Espana, S.L. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oil-in-water (O/W) emulsions containing gel phase were developed with cupuassu and/or cocoa butter from Brazilian ecosystem. They were subjected to storage advanced stability tests (SAST) and to in vivo corneometry evaluation. The evaluated emulsions showed great performance in the evaluated conditions considering that no significant variation was observed. The moisturizing potential was advantageous even without the moisturizing active. The formulation was considered a good cosmetic moisturizing cream and a promise as a drug carrier.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hot melt granulation of a coarse pharmaceutical powder in a top spray spouted bed is described. The substrate was lactose-polyvinylpyrrolidone particles containing or not acetaminophen as a drug model. Polyethylene glycol (MW, 4000) used as binder was atomized onto the bed by a two-fluid spray nozzle. The granulation experiments followed a 2(3) factorial design with triplicates at the center point and were carried out by varying the spray nozzle vertical position, the atomizing air flow rate and the binder feed rate. Granules were evaluated by their pharmacotechnical properties like size distribution, bulk and tapped densities, Carr index, Hausner ratio and tableting characteristics. Analysis of variance showed that granule sizes were affected by the PEG feed rate and atomizing air pressure at the significance levels of 1.0 and 5.0%. respectively, but spray nozzle distance to the substrate bed was not significant. The spray conditions also affected granule flow and consolidation properties. measured by the Carr index and Hausner ratio. Measured densities, Carr indexes and Hausner ratios proved that granules flowability and consolidation properties are adequate for pharmaceutical processing and tableting. Tablets prepared with acetaminophen-containing granules showed good properties and adequate release profiles in in vitro dissolution tests. The results indicate the suitability of spouted beds for the hot melt granulation of pharmaceutical coarse powders. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study is an integral part of a research project which seeks the establishment of protocols for the production of standardized herbal dried extracts emphasizing the spouted bed drying. This thesis was conducted at faculty of Pharmaceutical Science of Ribeiro Preto/University of So Paulo, Brazil, under supervision of Prof. Dr. Wanderley Pereira Oliveira*, defended on September 28, 2007.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel shear plate was used to make direct bed shear stress measurements in laboratory dam break and swash flows on smooth, fixed, impermeable beds. The pressure gradient due to the slope of the fluid free-surface across the plate was measured using pressure transducers. Surface elevation was measured at five locations using acoustic displacement sensors. Flow velocity was measured using an Acoustic-Doppler Velocimeter and calculated using the ANUGA inundation model. The measured bed shear stress at the dam break fluid tip for an initially dry, horizontal bed was close to twice that estimated using steady flow theory. The temporal variation of swash bed shear stress showed a large peak in landward directed stress at the uprush tip, followed by a rapid decay throughout the uprush flow interior. The peak seaward directed stress during the backwash phase was less than half that measured in the uprush. Close to the still water line, in the region of bore collapse and at the time of initial uprush, favourable pressure gradients were measured. In the lower swash region predominately weak adverse pressure gradients were measured.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coastal Photograph by Hubert Chanson This photograph of standing wave bed forms was taken at very low tide. The tidal range was 10 m. The bed forms were located on the island of Le Verdelet, in a channel between Le Grande Jaune and Le Verdelet. It is likely that these standing wave bed forms were formed during transcritical shallow water flows at the end of ebb tide. The author’s watch is in the foreground for scale. (Coastal Photograph by Hubert Chanson, Division of Civil Engineering, the University of Queensland, Brisbane, Queensland 4072, Australia.)