984 resultados para HEPES SIMPLEX
Resumo:
This work presents a novel surface Smart Polymer Antibody Material (SPAM) for Carnitine (CRT, a potential biomarker of ovarian cancer), tested for the first time as ionophore in potentiometric electrodes of unconventional configuration. The SPAM material consisted of a 3D polymeric network created by surface imprinting on graphene layers. The polymer was obtained by radical polymerization of (vinylbenzyl) trimethylammonium chloride and 4-styrenesulfonic acid (signaling the binding sites), and vinyl pivalate and ethylene glycol dimethacrylate (surroundings). Non-imprinted material (NIM) was prepared as control, by excluding the template from the procedure. These materials were then used to produce several plasticized PVC membranes, testing the relevance of including the SPAM as ionophore, and the need for a charged lipophilic additive. The membranes were casted over solid conductive supports of graphite or ITO/FTO. The effect of pH upon the potentiometric response was evaluated for different pHs (2-9) with different buffer compositions. Overall, the best performance was achieved for membranes with SPAM ionophore, having a cationic lipophilic additive and tested in HEPES (4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid) buffer, pH 5.1. Better slopes were achieved when the membrane was casted on conductive glass (-57.4 mV/decade), while the best detection limits were obtained for graphite-based conductive supports (3.6 × 10−5mol/L). Good selectivity was observed against BSA, ascorbic acid, glucose, creatinine and urea, tested for concentrations up to their normal physiologic levels in urine. The application of the devices to the analysis of spiked samples showed recoveries ranging from 91% (± 6.8%) to 118% (± 11.2%). Overall, the combination of the SPAM sensory material with a suitable selective membrane composition and electrode design has lead to a promising tool for point-of-care applications.
Resumo:
pp. 205-227
Resumo:
Using low cost portable devices that enable a single analytical step for screening environmental contaminants is today a demanding issue. This concept is here tried out by recycling screen-printed electrodes that were to be disposed of and by choosing as sensory element a low cost material offering specific response for an environmental contaminant. Microcystins (MCs) were used as target analyte, for being dangerous toxins produced by cyanobacteria released into water bodies. The sensory element was a plastic antibody designed by surface imprinting with carefully selected monomers to ensure a specific response. These were designed on the wall of carbon nanotubes, taking advantage of their exceptional electrical properties. The stereochemical ability of the sensory material to detect MCs was checked by preparing blank materials where the imprinting stage was made without the template molecule. The novel sensory material for MCs was introduced in a polymeric matrix and evaluated against potentiometric measurements. Nernstian response was observed from 7.24 × 10−10 to 1.28 × 10−9 M in buffer solution (10 mM HEPES, 150 mM NaCl, pH 6.6), with average slopes of −62 mVdecade−1 and detection capabilities below 1 nM. The blank materials were unable to provide a linear response against log(concentration), showing only a slight potential change towards more positive potentials with increasing concentrations (while that ofthe plastic antibodies moved to more negative values), with a maximum rate of +33 mVdecade−1. The sensors presented good selectivity towards sulphate, iron and ammonium ions, and also chloroform and tetrachloroethylene (TCE) and fast response (<20 s). This concept was successfully tested on the analysis of spiked environmental water samples. The sensors were further applied onto recycled chips, comprehending one site for the reference electrode and two sites for different selective membranes, in a biparametric approach for “in situ” analysis.
Resumo:
A novel artificial antibody for troponin T (TnT) was synthesized by molecular imprint (MI) on the surface of multiwalled carbon nanotubes (MWCNT). This was done by attaching TnT to the MWCNT surface, and filling the vacant spaces by polymerizing under mild conditions acrylamide (monomer) in N,N′-methylenebisacrylamide (cross-linker) and ammonium persulphate (initiator). After removing the template, the obtained biomaterial was able to rebind TnT and discriminate it among other interfering species. Stereochemical recognition of TnT was confirmed by the non-rebinding ability displayed by non-imprinted (NI) materials, obtained by imprinting without a template. SEM and FTIR analysis confirmed the surface modification of the MWCNT. The ability of this biomaterial to rebind TnT was confirmed by including it as electroactive compound in a PVC/plasticizer mixture coating a wire of silver, gold or titanium. Anionic slopes of 50 mV decade−1 were obtained for the gold wire coated with MI-based membranes dipped in HEPES buffer of pH 7. The limit of detection was 0.16 μg mL−1. Neither the NI-MWCNT nor the MWCNT showed the ability to recognize the template. Good selectivity was observed against creatinine, sucrose, fructose, myoglobin, sodium glutamate, thiamine and urea. The sensor was tested successfully on serum samples. It is expected that this work opens new horizons on the design of new artificial antibodies for complex protein structures.
Resumo:
Myoglobin (Mb) is among the cardiac biomarkers playing a major role in urgent diagnosis of cardiovascular diseases. Its monitoring in point-of-care is therefore fundamental. Pursuing this goal, a novel biomimetic ionophore for the potentiometric transduction of Mb is presented. It was synthesized by surface molecular imprinting (SMI) with the purpose of developing highly efficient sensor layers for near-stereochemical recognition of Mb. The template (Mb) was imprinted on a silane surface that was covalently attached to silica beads by means of self-assembled monolayers. First the silica was modified with an external layer of aldehyde groups. Then, Mb was attached by reaction with its amine groups (on the external surface) and subsequent formation of imine bonds. The vacant places surrounding Mb were filled by polymerization of the silane monomers 3-aminopropyltrimethoxysilane (APTMS) and propyltrimethoxysilane (PTMS). Finally, the template was removed by imine cleavage after treatment with oxalic acid. The results materials were finely dispersed in plasticized PVC selective membranes and used as ionophores in potentiometric transduction. The best analytical features were found in HEPES buffer of pH 4. Under this condition, the limits of detection were of 1.3 × 10−6 mol/L for a linear response after 8.0 × 10−7 mol/L with an anionic slope of −65.9 mV/decade. The imprinting effect was tested by preparing non-imprinted (NI) particles and employing these materials as ionophores. The resulting membranes showed no ability to detect Mb. Good selectivity was observed towards creatinine, sacarose, fructose, galactose, sodium glutamate, and alanine. The analytical application was conducted successfully and showed accurate and precise results.
Resumo:
1st ASPIC International Congress
Resumo:
JORNADAS DE ELECTROQUÍMICA E INOVAÇÃO 2013
Resumo:
III Jornadas de Electroquímica e Inovação (Electroquímica e Nanomateriais), na Universidade de Trás-os-Montes e Alto Douro, Vila Real, 16 a 17 de Setembro de 2013
Resumo:
Graduate Student Symposium on Molecular Imprinting 2013, na Queen’s University, Belfast, United Kingdom, 15 a 17 de Agosto de 2013
Resumo:
Herpes simplex virus type 1 (HSV-1) ophthalmic disease is the most common cause of corneal blindness in humans world-wide. Current culture techniques for HSV take several days and commercially available HSV laboratory based diagnostic techniques vary in sensitivity. Our study was conducted to evaluate the use of a quicker and simpler method to herpes ophthalmic diagnosis. Corneal smears were made by firm imprints of infected mouse eyes to glass slides, after smears were fixated with cold acetone, and an indirect immunofluorescence (IIF) method was performed using monoclonal antibodies in a murine model of ophthalmic herpes. Eye swabs from infected mice were inoculated in Vero cells for virus isolation. Cytology and histology of the eye were also performed, using hematoxylin-eosin routine. Mouse eyes were examined by slit-lamp biomicroscopy for evidence of herpetic disease at various times postinoculation. We made a comparative evaluation of sensitivity, specificity and speed of methods for laboratory detection of HSV. Our results indicate that this IIF method is quick, sensitive, specific and can be useful in the diagnosis of ophthalmic herpes as demonstrated in an animal model.
Resumo:
While CMV myeloradiculitis is a known complication in AIDS patients with severe immunosuppression, HSV-2 necrotizing myeloradiculitis is rare and often associated with disabling a fatal outcome. We hereby describe a 46 year-old HIV infected patient with profound and sustained immunosuppression who presented with an acute ascending paraparesis and urinary retention. Lumbar spine MRI showed contrast enhancement at the conus medullaris and cauda equine, and both CMV and HSV-2 CSF PCR were positive. Despite treatment, the patient died 20 days later. We review the main diagnostic and therapeutic aspects of herpes virus associated myeloradiculitis and discuss the approach in similar cases.
Resumo:
O trabalho consistiu no desenvolvimento e caracterização de sensores potenciométricos com base em polímeros de impressão molecular para a determinação de um antibiótico, a norfloxacina, em aquacultura. A simplicidade, o baixo custo e a interação rápida e reversível dos sensores potenciométricos com os analitos fizeram com que este fosse o tipo de sensor escolhido. O material sensor foi obtido por tecnologia de impressão molecular, baseada em polimerização em bulk, em que a NOR foi a molécula molde e foram utilizados como monómeros para autoconstrução dos sensores o pirrol, isoladamente, ou em conjunto com partículas de sílica gel funcionalizadas com 3-aminopropil. Também foi obtido material sensor, para controlo, em que a molécula molde NOR não estava presente (NIP). As características dos materiais sensores foram sujeitas a análise de microscopia eletrónica SEM e análise por espectrómetro de infravermelhos com transformada de Fourier. Os materiais sensores foram incluídos em membranas poliméricas, que seriam incorporadas em elétrodos. A avaliação do desempenho dos elétrodos foi feita através de curvas de calibração em diferentes meios (PBS, MES e HEPES). Também foi efetuada com sucesso a análise da sensibilidade dos elétrodos em água dopada. As diversas avaliações e análises efetuadas levaram a concluir que o MIP de pirrol com aditivo aniónico, foi o material sensor testado que permitiu obter melhores propriedades de resposta.
Resumo:
Some infections can be the cause of secondary nephrotic syndrome. The aim of this study was to describe the experience of a Renal Disease Reference Clinic from Central Brazil, in which serological markers of some infectious agents are systematically screened in children with nephrotic syndrome. Data were obtained from the assessment of medical files of all children under fifteen years of age, who matched nephrotic syndrome criteria. Subjects were tested for IgG and IgM antibodies against T. gondii and cytomegalovirus; antibodies against Herpes simplex, hepatitis C virus and HIV; and surface antigen (HBsAg) of hepatitis B virus. The VDRL test was also performed. 169 cases were studied. The median age on the first visit was 44 months and 103 (60.9%) patients were male. Anti-CMV IgG and IgM were found in 70.4% and 4.1%, respectively. IgG and IgM against Toxoplasma gondii were present in 32.5% and 5.3%, respectively. Two patients were positive for HBsAg, but none showed markers for HIV, hepatitis C, or Treponema pallidum. IgG and IgM against herpes simplex virus were performed on 54 patients, of which 48.1% and 22.2% were positive. IgM antibodies in some children with clinical signs of recent infection suggest that these diseases may play a role in the genesis of nephrotic syndrome.
Resumo:
The aims of this study were to compare the detection of human herpesviruses (HHVs) in the saliva of HIV-infected and healthy control children, and to evaluate associations between viral infection and gingivitis and immunodeficiency. Saliva samples were collected from 48 HIV-infected and 48 healthy control children. Clinical and laboratory data were collected during dental visits and from medical records. A trained dentist determined gingival indices and extension of gingivitis. Saliva samples were tested for herpes simplex virus types 1 and 2 (HSV-1 and HSV-2), varicella zoster virus (VZV), Epstein-Barr virus (EBV), and cytomegalovirus (CMV) by nested polymerase chain reaction assays. Thirty-five HIV-infected and 16 control children had gingivitis. Seventeen (35.4%) HIV-infected children and 13 (27%) control children were positive for HHVs. CMV was the most commonly detected HHV in both groups (HIV-infected, 25%; control, 12.5%), followed by HSV-1 (6.2% in both groups) and HSV-2 (HIV-infected, 4.2%; control, 8.3%). The presence of HHVs in saliva was not associated with the presence of gingivitis in HIV-1-infected children (p = 0.104) or healthy control children (p = 0.251), or with immunosuppression in HIV-infected individuals (p = 0.447). Gingivitis was correlated with HIV infection (p = 0.0001). These results suggest that asymptomatic salivary detection of HHVs is common in HIV-infected and healthy children, and that it is not associated with gingivitis.
Resumo:
The authors report a case of adenovirus- induced enlargement of the parotid gland involving a patient infected with human immunodeficiency virus (HIV). Physical examination revealed good general condition, no fever and bilateral enlargement of the parotid region, which was of increased consistency and slightly tender to palpation. Histological examination of the parotid gland demonstrated a slight periductal lymphomononuclear inflammatory infiltrate with the presence of focal points of necrosis. Tests to determine the presence of fungi and alcohol-acid resistent bacilli were negative. Immunohistochemistry for cytomegalovirus, heipes simplex, HIV p24 antigen and adenovirus showed positivity only for adenovirus in the epithelial nuclei of numerous gland ducts. Tins is the third case of this type reported in the literature, indicating the importance of including adenovirus in the differential diagnosis of this condition.