993 resultados para HDPE and PVC geomembranes
Resumo:
The dataset is based on samples taken from 12 stations in Southern Aegean Sea, Northern Aegean Sea, Ionian Sea and Libyan Sea during March-April 2008. 12 Niskin bottles (8lt) made by PVC with rubber coated o rings and stainless steel ss springs. Seawater samples (150 ml) were collected from selected depths of the water column (2, 20, 50, 75, 100 m) for the identification and enumeration of phytoplankton cells (>=5 µm). The samples were fixed with Lugol solution and concentrated to 25 ml by sedimentation. Phytoplankton species abundance was determined with an inverted light microscope (OLYMPUS IX70) according to the Utermohl method (Utermohl, 1958).
Resumo:
This study deals with the rheological aspects of poly-vinyl chloride (PVC) plastisol gelation and fusion processes in foamable formulations. Here, such processes are simulated by temperature-programmed experiment (5 K min−1) in which complex viscosity components are continuously recorded. Nineteen samples based on a PVC-VAC (vinyl acetate 95/5) copolymer with 100 phr plasticizer have been studied, differing only by the plasticizer structure. The sample shear modulus increases continuously with temperature until a maximum, long time after the end of the dissolution process as characterized by DSC. The temperature at the maximum varies between 345 and 428 K with a clear tendency to increase almost linearly with the plasticizer molar mass, and to vary with the flexibility and the degree of branching of the plasticizer molecule. The shear modulus increase is interpreted in terms of progressive “welding” of swelled particles by polymer chain reptation. The plasticizer nature would mainly affect the friction parameter of chain diffusion.
Resumo:
Paper submitted to the 7th International Symposium on Feedstock Recycling of Polymeric Materials (7th ISFR 2013), New Delhi, India, 23-26 October 2013.
Resumo:
The mode II fracture toughness of an oriented PVC pipe was measured using an End Notched Flexure test geometry. A relatively low value of G(IIC) was found of 1.07 kJ m(-2) and this indicates that it is energetically more favorable for a crack to propagate in the tangential direction rather than radially through the wall of the pipe. Examination of the mechanism of crack advanced showed that although the crack was propagating globally in mode II, micro-cracks were opening ahead of the crack in mode I or in mixed mode. Growth of the crack occurred by linking up of these micro-cracks. This is similar to the mechanism found for mode II cracking in carbon fibre epoxy composites. (C) 2004 Kluwer Academic Publishers.
Resumo:
Quantifying water losses in paddy fields assists estimation of water availability in rainfed lowland rice ecosystem. Little information is available on water balance in different toposequence positions of sloped rainfed lowland. Therefore, the aim of this work was to quantify percolation and the lateral water flow with special reference to the toposequential variation. Data used for the analysis was collected in Laos and northeast Thailand. Percolation and water tables were measured on a daily basis using a steel cylindrical tube with a lid and perforated PVC tubes, respectively. Percolation rate was determined using linear regression analysis of cumulative percolation. Assuming that the total amount of evaporation and transpiration was equivalent to potential evapotranspiration, the lateral water flow was estimated using the water balance equation. Separate perched water and groundwater tables were observed in paddy fields on coarse-textured soils. The percolation rate varied between 0 and 3 mm/day across locations, and the maximum water loss by lateral movement was more than 20 mm/day. Our results are in agreement with the previously reported findings, and the methodology of estimating water balance components appears reasonably acceptable. With regard to the toposequential variation, the higher the position in the topoesquence, the greater potential for water loss because of higher percolation and lateral flow rates.
Resumo:
DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT
Resumo:
A thermogravimetric methodology was developed to investigate and semi-quantify the extent of synergistic effects during pyrolysis and combustion of municipal solid waste (MSW). Results from TGA-MS were used to compare the pyrolysis and combustion characteristics of single municipal solid waste components (polyvinyl chloride (PVC), polypropylene (PP), polystyrene (PS), branches (BR), leaves (LV), grass (GR), packaging paper (PK), hygienic paper (HP) and cardboard (CB)) and a mixture (MX) of PP, BR and CB. Samples were heated under dynamic conditions at 20°C/min from 25°C to 1000°C with the continuous record of their main evolved fragments. Synergistic effects were evaluated by comparing experimental and calculated weight losses and relative areas of MS peaks. Pyrolysis of the mixture happened in two stages, with the release of H2, CH4, H2O, CO and CO2 between 200 and 415°C and the release of CH4, CxHy, CO and CO2 between 415 and 525°C. Negative synergistic effect in the 1st stage was attributed to the presence of PP where the release of hydrocarbons and CO2 from BR and CB was inhibited, whereas positive synergistic effects were observed during the 2nd degradation stage. In a second part of the study, synergistic effects were related to the dependency of the effective activation energy (Eα) versus the conversion (α). Higher Eαs were obtained for MX during its 1st stage of pyrolysis and lower Eαs for the 2nd stage when compared to the individual components. On the other hand, mostly positive synergistic effects were observed during the combustion of the same mixture, for which lower Eαs were recorded.
Resumo:
This paper suggests modifications in coating of electrodes providing an alternative for execution of welding with low hydrogen electrode AWS E7018 without having to dry it, reducing thus the cost and time of manufacturing of high resistance welds. The welds in this research were developed with basic coated electrodes (hygroscopic) – SMAW process – externally painted with aluminum spray paint for high temperatures or wrapped with thin plastic films (PVC) and aluminum foil films used commonly for food protection. The basic premise is that establishing a barrier between the atmosphere and the electrode coating could reduce the effects of high hygroscopicity presented by coatings of low hydrogen, minimizing this way the main source of supply of hydrogen to the fusion pool during welding. It is also expected that the addition of new materials from the electrode coating to the fusion pool would induce metallurgical changes in the deposited metal and, as a consequence, modifications in its mechanical properties. This research dealt with measuring the dissolved hydrogen in the deposited metal after welding with modified electrodes, evaluating the influence of these changes in the produced microstructures and in the mechanical properties of the resulting weld, and comparing the obtained results with the standard welding procedures and with the recently developed waterproof electrodes. The results obtained in most samples welded with modified electrodes showed increased mechanical resistance and increased tenacity due to the increased percentage of acicular ferrite in metal deposited without significant elevation of hardness, when compared with the traditional welding with AWS E7018 electrode and with ELBRÁS BRH4R waterproof electrode. The diffusing hydrogen measured in the modified electrodes was kept inside the parameters defined by international codes.
Resumo:
This paper suggests modifications in coating of electrodes providing an alternative for execution of welding with low hydrogen electrode AWS E7018 without having to dry it, reducing thus the cost and time of manufacturing of high resistance welds. The welds in this research were developed with basic coated electrodes (hygroscopic) – SMAW process – externally painted with aluminum spray paint for high temperatures or wrapped with thin plastic films (PVC) and aluminum foil films used commonly for food protection. The basic premise is that establishing a barrier between the atmosphere and the electrode coating could reduce the effects of high hygroscopicity presented by coatings of low hydrogen, minimizing this way the main source of supply of hydrogen to the fusion pool during welding. It is also expected that the addition of new materials from the electrode coating to the fusion pool would induce metallurgical changes in the deposited metal and, as a consequence, modifications in its mechanical properties. This research dealt with measuring the dissolved hydrogen in the deposited metal after welding with modified electrodes, evaluating the influence of these changes in the produced microstructures and in the mechanical properties of the resulting weld, and comparing the obtained results with the standard welding procedures and with the recently developed waterproof electrodes. The results obtained in most samples welded with modified electrodes showed increased mechanical resistance and increased tenacity due to the increased percentage of acicular ferrite in metal deposited without significant elevation of hardness, when compared with the traditional welding with AWS E7018 electrode and with ELBRÁS BRH4R waterproof electrode. The diffusing hydrogen measured in the modified electrodes was kept inside the parameters defined by international codes.
Resumo:
This material is based upon work supported by the National Science Foundation through the Florida Coastal Everglades Long-Term Ecological Research program under Cooperative Agreements #DBI-0620409 and #DEB-9910514. This image is made available for non-commercial or educational use only.
Resumo:
In industrial plants, oil and oil compounds are usually transported by closed pipelines with circular cross-section. The use of radiotracers in oil transport and processing industrial facilities allows calibrating flowmeters, measuring mean residence time in cracking columns, locate points of obstruction or leak in underground ducts, as well as investigating flow behavior or industrial processes such as in distillation towers. Inspection techniques using radiotracers are non-destructive, simple, economic and highly accurate. Among them, Total Count, which uses a small amount of radiotracer with known activity, is acknowledged as an absolute technique for flow rate measurement. A viscous fluid transport system, composed by four PVC pipelines with 13m length (12m horizontal and 1m vertical) and ½, ¾, 1 and 2-inch gauges, respectively, interconnected by maneuvering valves was designed and assembled in order to conduct the research. This system was used to simulate different flow conditions of petroleum compounds and for experimental studies of flow profile in the horizontal and upward directions. As 198Au presents a single photopeak (411,8 keV), it was the radioisotope chosen for oil labeling, in small amounts (6 ml) or around 200 kBq activity, and it was injected in the oil transport lines. A NaI scintillation detector 2”x 2”, with well-defined geometry, was used to measure total activity, determine the calibration factor F and, positioned after a homogenization distance and interconnected to a standardized electronic set of nuclear instrumentation modules (NIM), to detect the radioactive cloud.
Resumo:
Dip moulded plastic beret. One of a series starting from Jelly Beret 1997.This was made with a UK with the design company Inflate. This 2009 iteration of the PVC beret chosen for Stephen Jones Hat Anthology V&A, the first millinery exhibition of millinery design held at V&A. Whereas traditional millinery is known for its rather staid and bourgeois Stephen Jones selected chose this hat for its edgy sub cultural capital.This is reflected in the choices of materials and beret style with a reference to the Bohemien Parisienne avant garde revisited in 1960s London and made new for 21st century NY "Jelly Beret" the very first prototype of a plastic millinery Reviewed in Vogue UK, this travelling exhibition went from London, New York, Sydney to add exists at the V&A as a touring show. An accompanying catalogue by Oriole Cullen and Stephen Jones discusses the significance of innovative and original millinery design international design culture today.
Resumo:
Dip moulded plastic PVC beret. One of series starting from Jelly Beret 1997. This was made with the design company Inflate. This 2009 iteration of the PVC beret chosen for Stephen Jones Hat Anthology V&A, the first millinery exhibition of millinery design held at V&A. Whereas traditional millinery is known for its rather staid and bourgoise Stephen Jones selected chose this hat for its edgy sub cultural capital. This is reflected in the choices of materials and beret style with a reference to the Bohemien Parisienne avant garde revisited in 1960s London and made new for 21st century NY. "Jelly Beret" the very first prototype of a plastic millinery, reviewed in Elle 2000. This travelling exhibition went from London, New York, Sydney and exists at the V&A as a touring show. An accompanying catalogue by Oriole Cullen and Stephen Jones discusses the significance of innovative and original millinery design international design culture today.. " “House of Flora is noted for its sculptural and architecturally inspired hats made from technologically innovative materials such as latex,PVC and Perspex” Oriole Cullen
Resumo:
Nitrous oxide (N2O) is a potent greenhouse gas with a global warming potential 298 times higher than carbon dioxide. Soils are a natural source of N2O, contributing 65% of global emissions. This paper is the first in Australia to measure and compare N2O emissions from pre-plant controlled release (CR) and conventional granular (CV) fertilisers in pineapple production using static PVC chambers to capture N2O emissions. Farm 1 cumulative emissions from the CR fertiliser were 3.22 kg ha-1 compared to 6.09 kg ha-1 produced by the CV. At farm 2 the CV blend emitted 2.36 kg ha-1 in comparison to the CR blend of 2.92 kg ha-1. Daily N2O flux rates showed a relationship of direct response to rainfall and soil moisture availability. High emissions were observed for wheel tracks where increased N2O emissions may be linked to soil compaction and waterlogging that creates anaerobic conditions after rain events. Emission measurements over three months highlighted the inconsistencies found in other studies relative to reducing emissions through controlled release nitrogen. More investigations are required to verify the benefits associated with controlled release fertiliser use in pineapples, placement and seasonal timing to address N2O emissions in pineapples.