951 resultados para Gini coefficient


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presentwork aimed to determine howthe average fibre diameter coefficient of variation (CVD) and fibre curvature (FC) differences between nine sampling sites vary between sex and flock, to identify differences in variability between sampling sites as a result of between animal and between sire variability and to determine correlations between sampling sites in between animal and between sire variability. Australian Angoras (n = 313) from two farms in southern Australia were sampled at 12 and 18 months of age at nine sites (mid side, belly, brisket, hind flank, hip, hock, mid back, neck, shoulder). Staples were taken prior to shearing at skin level and CVD and FC determined. For each shearing, differences in CVD and FC between sampling sites, how these differences were affected by farm, sex, and sire, and the covariance between sites for sire and individual animal effects were investigated by restricted maximum likelihood (REML) analyses. The median mid side CVD at 12 and 18 months of age ranged from 23.6 to 25.1% but the actual range was 16.8–34.2%. The median mid side FC at 12 and 18 months of age ranged from 14.4 to 18.6◦/mm but the actual range was 10.5–26.3◦/mm. The general pattern for CVDwas for the mid back, hip and neck sites to have similar CVD, the brisket, hind flank and hock sites to have larger CVD and the belly to have smaller CVD than the mid side site. The between animal variation for CVD was lowest at the mid back site. This implies that the mid back would be the most effective site for between animal selection for CVD. Heritabilities for CVD (range at 18 months 0.18–0.30) were only about half the heritabilities for mean fibre diameter in the same study. There was a marked anterior–posterior increase in FC at both farms and with both ages. The results give no clear indication of the best site for between animal selection for FC, other than that the hock should be avoided. Heritabilities for FC are moderate to high (range at 18 months 0.44–0.77) and the genetic correlations are high except for the hock. Thus genetic selection for FC at any site, other than the hock, should be effective for changing FC over the entire fleece. There was more variability between animals than between sites and sires. These results are put into context with associated research on variation in mean fibre diameter and staple length.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Distributed Denial of Service (DDoS) attack is a critical threat to the Internet, and botnets are usually the engines behind them. Sophisticated botmasters attempt to disable detectors by mimicking the traffic patterns of flash crowds. This poses a critical challenge to those who defend against DDoS attacks. In our deep study of the size and organization of current botnets, we found that the current attack flows are usually more similar to each other compared to the flows of flash crowds. Based on this, we proposed a discrimination algorithm using the flow correlation coefficient as a similarity metric among suspicious flows. We formulated the problem, and presented theoretical proofs for the feasibility of the proposed discrimination method in theory. Our extensive experiments confirmed the theoretical analysis and demonstrated the effectiveness of the proposed method in practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mass transfer coefficient is an important kinetic factor to control the thermo-chemical treatment processes of metals and alloys. More importantly, the mass transfer coefficient is different at different surface positions of a metallic part treated, which depends on the dynamic characteristics of the atmosphere close to the treated surface. Understanding the local mass transfer coefficient would be significant to approach the expected physical and mechanical properties of treated surfaces. In this paper, a reverse method was proposed to measure the mass transfer coefficient at component surface and the diffusivity in metal during heat treatment. The methodology of the reverses method and the optimal parame-ters are discussed in some detail. This method was successfully used to determine the car-bon transfer coefficient at the surface of a part in a carburizing furnace and carbon diffusiv-ity from the carbon distribution within the diffusion layer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is a robust comorbidity between mood disorders and cardiovascular disorder (CVD). The atherogenic index of plasma (AIP) and the atherogenic coefficient (AC) are important atherogenic indexes. The aims of this study were to delineate whether AIP and AC are increased in mood disorders especially when comorbid with tobacco use disorder (TUD).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Weak monotonicity was recently proposed as a relaxation of the monotonicity condition for averaging aggregation, and weakly monotone functions were shown to have desirable properties when averaging data corrupted with outliers or noise. We extended the study of weakly monotone averages by analyzing their ϕ-transforms, and we established weak monotonicity of several classes of averaging functions, in particular Gini means and mixture operators. Mixture operators with Gaussian weighting functions were shown to be weakly monotone for a broad range of their parameters. This study assists in identifying averaging functions suitable for data analysis and image processing tasks in the presence of outliers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent advances in thermoelectrochemical cells, which are being developed for harvesting low grade waste heat, have shown the promise of cobalt bipyridyl salts as the active redox couple. The Seebeck coefficient, Se, of a redox couple determines the open circuit voltage achievable, for a given temperature gradient, across the thermoelectrochemical cell. Thus, the accurate determination of this thermodynamic parameter is key to the development and study of new redox electrolytes. Further, techniques for accurate determination of Se using only one half of the redox couple reduces the synthetic requirements. Here, we compare three different experimental techniques for measuring Se of a cobalt tris(bipyridyl) redox couple in ionic liquid electrolytes. The use of temperature dependent cyclic voltammetry (CV) in isothermal and non-isothermal cells was investigated in depth, and the Se values compared to those from thermo-electromotive force measurements. Within experimental error, the Se values derived from CV methods were found to be in accordance with those obtained from electromotive force (emf) measurements. The applicability of cyclic voltammetry techniques for determining Se when employing only one part of the redox couple was demonstrated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

© The Author, 2014. Most studies of the predictability of returns are based on time series data, and whenever panel data are used, the testing is almost always conducted in an unrestricted unit-by-unit fashion, which makes for a very heavy parametrization of the model. On the other hand, the few panel tests that exist are too restrictive in the sense that they are based on homogeneity assumptions that might not be true. As a response to this, the current study proposes new predictability tests in the context of a random coefficient panel data model, in which the null of no predictability corresponds to the joint restriction that the predictive slope has zero mean and variance. The tests are applied to a large panel of stocks listed at the New York Stock Exchange. The results suggest that while the predictive slopes tend to average to zero, in case of book-to-market and cash flow-to-price the variance of the slopes is positive, which we take as evidence of predictability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we propose a class of ACD-type models that accommodates overdispersion, intermittent dynamics, multiple regimes, and sign and size asymmetries in financial durations. In particular, our functional coefficient autoregressive conditional duration (FC-ACD) model relies on a smooth-transition autoregressive specification. The motivation lies on the fact that the latter yields a universal approximation if one lets the number of regimes grows without bound. After establishing that the sufficient conditions for strict stationarity do not exclude explosive regimes, we address model identifiability as well as the existence, consistency, and asymptotic normality of the quasi-maximum likelihood (QML) estimator for the FC-ACD model with a fixed number of regimes. In addition, we also discuss how to consistently estimate using a sieve approach a semiparametric variant of the FC-ACD model that takes the number of regimes to infinity. An empirical illustration indicates that our functional coefficient model is flexible enough to model IBM price durations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An interferometric technique was used to determine the temperature coefficient of the optical path length (dS/dT) as a function of the temperature in several optical glasses. The temperature range was between 25degreesC and 180degreesC. The studied samples included undoped and doped oxide glasses, such as low silica calcium aluminosilicate, phosphates, borates and also chalcogenides. The oxide glasses had dS/dT between 10 X 10(-6) K-1 and 20x10(-6) K-1, while for the chalcogenides, these were around 70 x 10(-6)K(-1). The results showed that dS/dTs increased with the temperature in all samples. For samples doped with Nd the dS/dT values were found to be independent of concentration. on the other hand, for the phosphate glass doped with Cr, dS/dT increased about 5% when compared with the Nd doped one. In conclusion, the used interferometric method, which is a considerably simpler and a lower cost technique, and is a useful tool to measure dS/dT in semi-transparent glasses as a function of the composition and temperature. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)