888 resultados para GLUCOSE MONITORING-SYSTEM


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Transmission of Cherenkov light through the atmosphere is strongly influenced by the optical clarity of the atmosphere and the prevailing weather conditions. The performance of telescopes measuring this light is therefore dependent on atmospheric effects. This thesis presents software and hardware developed to implement a prototype sky monitoring system for use on the proposed next-generation gamma-ray telescope array, VERITAS. The system, consisting of a CCD camera and a far-infrared pyrometer, was successfully installed and tested on the ten metre atmospheric Cherenkov imaging telescope operated by the VERITAS Collaboration at the F.L. Whipple Observatory in Arizona. The thesis also presents the results of observations of the BL Lacertae object, 1ES1959+650, made with the Whipple ten metre telescope. The observations provide evidence for TeV gamma-ray emission from the BL Lacertae object, 1ES1959+650, at a level of more than 15 standard deviations above background. This represents the first unequivocal detection of this object at TeV energies, making it only the third extragalactic source seen at such levels of significance in this energy range. The flux variability of the source on a number of timescales is also investigated.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The article provides a method for long-term forecast of frame alignment losses based on the bit-error rate monitoring for structure-agnostic circuit emulation service over Ethernet in a mobile backhaul network. The developed method with corresponding algorithm allows to detect instants of probable frame alignment losses in a long term perspective in order to give engineering personnel extra time to take some measures aimed at losses prevention. Moreover, long-term forecast of frame alignment losses allows to make a decision about the volume of TDM data encapsulated into a circuit emulation frame in order to increase utilization of the emulated circuit. The developed long-term forecast method formalized with the corresponding algorithm is recognized as cognitive and can act as a part of network predictive monitoring system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Este proyecto consiste en la implantación de un sistema SCADA en una planta piloto de fabricación y envasado de líquidos. En este documento se muestra toda la información que ha sido necesaria para realizar el sistema de automatización en los tres niveles propios de un SCADA: nivel de campo, nivel de control y nivel de supervisión. El trabajo de campo ha sido, típicamente de revisión, puesto que el Departament de Telecomunicació i d’Enginyeria de Sistemes ya poseía la planta totalmente equipada, mientras que el sistema de control y el sistema de supervisión se han implantado totalmente.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Åknes is an active complex large rockslide of approximately 30?40 Mm3 located within the Proterozoic gneisses of western Norway. The observed surface displacements indicate that this rockslide is divided into several blocks moving in different directions at velocities of between 3 and 10 cm year?1. Because of regional safety issues and economic interests this rockslide has been extensively monitored since 2004. The understanding of the deformation mechanism is crucial for the implementation of a viable monitoring system. Detailed field investigations and the analysis of a digital elevation model (DEM) indicate that the movements and the block geometry are controlled by the main schistosity (S1) in gneisses, folds, joints and regional faults. Such complex slope deformations use pre-existing structures, but also result in new failure surfaces and deformation zones, like preferential rupture in fold-hinge zones. Our interpretation provides a consistent conceptual three-dimensional (3D) model for the movements measured by various methods that is crucial for numerical stability modelling. In addition, this reinterpretation of the morphology confirms that in the past several rockslides occurred from the Åknes slope. They may be related to scars propagating along the vertical foliation in folds hinges. Finally, a model of the evolution of the Åknes slope is presented.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: Falls efficacy, defined as confidence in performing activities without falling, is a measure of fear of falling associated with gait impairment, falls and functional decline in frail older people. This relationship has not been well studied in high-functioning older people. Objective: To evaluate the relationship between falls efficacy and gait performance in a cohort of high-functioning older people. Methods: Subjects (N = 864) were a subsample of communitydwelling older people aged 65 to 70 years, enrolled in the "Lc65+" cohort, who completed gait assessment at baseline. Data were collected on demographics, functional, cognitive, affective, and health status. Falls efficacy was assessed using the Falls Efficacy Scale- International (FES-I) that measures confidence in performing 16 activities of daily life (ADL) without falling (score from 16 to 64, higher score indicates lower confidence). Gait parameters were measured over a 20 m walk at preferred gait speed using Physilog, an ambulatory gait monitoring system. Results: Participants (mean age 68.0 ± 1.4 years, 55.0% women) had excellent physical (92.2% independent in basic ADL, mean gait speed 1.13 ± 0.16 m/sec) and cognitive (98.0% with MMSE 024) performance. Nevertheless, 22.1% reported depressive symptoms and 16.1% one or more fall in the previous year. Mean FES-I score was 18.8 ± 4.1. Falls efficacy was associated with gait speed (Spearman rho -0.23, P <.001) and gait variability (Spearman rho 0.10, P = .006), measured by the coefficient of variation of stride velocity. These associations remained in multivariate analysis for both gait speed (adj [beta] coeff: -0.008, 95%CI -0.005 to -0.010, P <.001) and gait variability (adj [beta] coeff 0.024, 95%CI 0.003 to 0.045, P = .023) independent of gender, falls, functional, affective, cognitive, and frailty (Fried's criteria) status. On average, compared to subjects with poor confidence in performing one ADL without falling, those with full confidence had a 0.02 m/sec (2%) faster gait speed and a 2% decrease in gait variability. Conclusion: Even in high-functioning older people, poor falls efficacy is associated with reduced gait speed and stability, independent of health, functional, and frailty status. The direction of this relationship needs to be investigated prospectively to determine causality and design interventions to improve gait performance, reduce fall risk, and prevent functional decline.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A Statistical Overview: 2002 Following some scene setting, the report draws together wide ranging information to document inequalities in health and social care in Northern Ireland that are relevant to the New Targeting Social Need (New TSN) policy, including the base report of the ‘Inequalities Monitoring System’. The overview also documents comparisons between people living in rural and non-rural areas, and between the statutory equality categories of Section 75 of the Northern Ireland Act. While some of the information has been previously published most of the results are new, and the majority of the new analyses has been undertaken by IAD. åÊ

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Department of Health, Social Services and Public Safety (Northern Ireland) published its first sub-regional bulletin of the Health and Social Care Inequalities Monitoring System (HSCIMS) on Wednesday, 7th July.The bulletin provides a picture of health inequalities at Health and Social Care (HSC) Trust level and a detailed comparison of morbidity, mortality, utilisation and access to health and social services between the 20% most deprived areas within a Trust and the overall Trust as well as NI as a whole. Health and Social Services Inequalities Monitoring System. Sub-Regional Inequalities HSC Trusts 2010 (PDF 5.6MB)��The Inequalities Monitoring system comprises various indicators which are monitored over time to assess area differences across morbidity, utilisation and access to Health and Social Care services in NI. Results for each indicator for the 20% most deprived (as per 2005 NISRA Measures of Deprivation) and the 20% most rural areas are compared with the NI average. There is also a comparison of the Section 75 equality group profiles of the areas with the 20% worst outcomes with NI overall for selected indicators.��

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Proyecto fin de Máster sobre la implantación de un sistema de monitorización.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Glucose control is the cornerstone of Diabetes Mellitus (DM) treatment. Although self-regulation using capillary glycemia (SRCG) still remains the best procedure in clinical practice, continuous glucose monitoring systems (CGM) offer the possibility of continuous and dynamic assessment of interstitial glucose concentration. CGM systems have the potential to improve glycemic control while decreasing the incidence of hypoglycemia but the efficiency, compared with SRCG, is still debated. CGM systems have the greatest potential value in patients with hypoglycemic unawareness and in controlling daily fluctuations in blood glucose. The implementation of continuous monitoring in the standard clinical setting has not yet been established but a new generation of open and close loop subcutaneous insulin infusion devices are emerging making insulin treatment and glycemic control more reliable.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Es mostra la implantació d'un sistema de monitorització d'un CPD en una administració pública amb Nagios i Centreon, i es compara breument amb algunes alternatives.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Measuring syringe availability and coverage is essential in the assessment of HIV/AIDS risk reduction policies. Estimates of syringe availability and coverage were produced for the years 1996 and 2006, based on all relevant available national-level aggregated data from published sources. METHODS: We defined availability as the total monthly number of syringes provided by harm reduction system divided by the estimated number of injecting drug users (IDU), and defined coverage as the proportion of injections performed with a new syringe, at national level (total supply over total demand). Estimates of supply of syringes were derived from the national monitoring system, including needle and syringe programmes (NSP), pharmacies, and medically prescribed heroin programmes. Estimates of syringe demand were based on the number of injections performed by IDU derived from surveys of low threshold facilities for drug users (LTF) with NSP combined with the number of IDU. This number was estimated by two methods combining estimates of heroin users (multiple estimation method) and (a) the number of IDU in methadone treatment (MT) (non-injectors) or (b) the proportion of injectors amongst LTF attendees. Central estimates and ranges were obtained for availability and coverage. RESULTS: The estimated number of IDU decreased markedly according to both methods. The MT-based method (from 14,818 to 4809) showed a much greater decrease and smaller size of the IDU population compared to the LTF-based method (from 24,510 to 12,320). Availability and coverage estimates are higher with the MT-based method. For 1996, central estimates of syringe availability were 30.5 and 18.4 per IDU per month; for 2006, they were 76.5 and 29.9. There were 4 central estimates of coverage. For 1996 they ranged from 24.3% to 43.3%, and for 2006, from 50.5% to 134.3%. CONCLUSION: Although 2006 estimates overlap 1996 estimates, the results suggest a shift to improved syringe availability and coverage over time.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The clinical demand for a device to monitor Blood Pressure (BP) in ambulatory scenarios with minimal use of inflation cuffs is increasing. Based on the so-called Pulse Wave Velocity (PWV) principle, this paper introduces and evaluates a novel concept of BP monitor that can be fully integrated within a chest sensor. After a preliminary calibration, the sensor provides non-occlusive beat-by-beat estimations of Mean Arterial Pressure (MAP) by measuring the Pulse Transit Time (PTT) of arterial pressure pulses travelling from the ascending aorta towards the subcutaneous vasculature of the chest. In a cohort of 15 healthy male subjects, a total of 462 simultaneous readings consisting of reference MAP and chest PTT were acquired. Each subject was recorded at three different days: D, D+3 and D+14. Overall, the implemented protocol induced MAP values to range from 80 ± 6 mmHg in baseline, to 107 ± 9 mmHg during isometric handgrip maneuvers. Agreement between reference and chest-sensor MAP values was tested by using intraclass correlation coefficient (ICC = 0.78) and Bland-Altman analysis (mean error = 0.7 mmHg, standard deviation = 5.1 mmHg). The cumulative percentage of MAP values provided by the chest sensor falling within a range of ±5 mmHg compared to reference MAP readings was of 70%, within ±10 mmHg was of 91%, and within ±15mmHg was of 98%. These results point at the fact that the chest sensor complies with the British Hypertension Society (BHS) requirements of Grade A BP monitors, when applied to MAP readings. Grade A performance was maintained even two weeks after having performed the initial subject-dependent calibration. In conclusion, this paper introduces a sensor and a calibration strategy to perform MAP measurements at the chest. The encouraging performance of the presented technique paves the way towards an ambulatory-compliant, continuous and non-occlusive BP monitoring system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To identify the issues occurred with nursing workers through a Health Monitoring System for Nursing Workers (SIMOSTE) and to describe the consequences of those problems. Method: This is a quantitative, exploratory and descriptive study realized in a teaching hospital in the west region of the city of São Paulo. Results: From the SIMOSTE, 1.847 occurrences were registered in a six month period. Within the main occurrences, medical licenses, work related accidents with and without removals; psychiatric consultations and psychotherapy were highlighted. Conclusion: The data points out to the need for the development of new health vigilance actions to notify accidents and illness related to work, besides the prevention of issues. 


Relevância:

80.00% 80.00%

Publicador:

Resumo:

ABSTRACT OBJECTIVE To identify the workloads present in the work activities of community health agents (CHAs) and the resulting strain processes. METHOD A descriptive, exploratory, cross-sectional and quantitative study conducted with 137 CHAs. Data were collected through a questionnaire and interview guided by the health surveillance software called SIMOSTE (Health Monitoring System of Nursing Workers), following the ethical codes of the current law. RESULTS In total, were identified 140 workloads involved in 122 strain processes, represented by the occurrence of health problems of the CHAs. The mechanical (55.00%) and biological (16.43%) loads stood out. The most common strain processes were the external causes of morbidity and mortality (62.31%) and diseases of the musculoskeletal system and connective tissue (10.66%). CONCLUSION From the identified overloads, it became evident that all workloads are present in the work process of CHAs, highlighting the mechanical load, represented mainly by external causes of morbidity and mortality that are related to occupational accidents.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Con el examen conjunto de datos de seguimiento satelital de la flota pesquera y de marcaje electrónico de aves marinas, se analizan las interacciones entre la actividad pesquera y el forrajeo de las aves en periodo de reproducción. Se evidencia que las aves pueden mitigar la competencia con la pesca hasta cierto punto, forrajeando más lejos o quedándose más tiempo en el mar. Sin embargo, las aves en reproducción enfrentan a la vez un alto requerimiento energético para alimentar los pichones, y viajes de forrajeo limitados en distancia y tiempo por la necesidad de atender el nido. Para optimizar el éxito reproductivo de las aves marinas se recomienda: (1) Estimar, con la ayuda de modelos ecotróficos, qué cantidad de anchoveta sería conveniente ‘reservar’ para la alimentación de las aves; (2) Establecer zonas temporalmente cerradas a la pesca, alrededor de las principales colonias en los meses de reproducción de las aves. Los rangos máximos de forrajeo observados en guanayes y piqueros sugieren un radio de 50 a 100 km alrededor de las colonias, lo cual permitiría asegurar el forrajeo de estas especies en periodo de reproducción y así favorecer la sostenibilidad de sus poblaciones.