995 resultados para Flue gas equipment


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we analyzed the adsorption of gases and vapors on graphitised thermal carbon black by using a modified DFT-lattice theory, in which we assume that the behavior of the first layer in the adsorption film is different from those of second and higher layers. The effects of various parameters on the topology of the adsorption isotherm were first investigated, and the model was then applied in the analysis of adsorption data of numerous substances on carbon black. We have found that the first layer in the adsorption film behaves differently from the second and higher layers in such a way that the adsorbate-adsorbate interaction energy in the first layer is less than that of second and higher layers, and the same is observed for the partition function. Furthermore, the adsorbate-adsorbate and adsorbate-adsorbent interaction energies obtained from the fitting are consistently lower than the corresponding values obtained from the viscosity data and calculated from the Lorentz-Berthelot rule, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors investigated the effect of manual hyperinflation (MHI) with set parameters applied to patients on mechanical ventilation on hemodynamics, respiratory mechanics, and gas exchange. Sixteen critically ill patients post-septic shock, with acute lung injury, were studied. Heart rate, arterial pressure, and mean pulmonary artery pressure were recorded every minute. pulmonary artery occlusion pressure, cardiac output, arterial blood gases, and dynamic compliance (C-dyn) were recorded pre- and post-MHI. From this, systemic vascular resistance index (SVRI), cardiac index, oxygen delivery, and partial pressure of oxygen:fraction of inspired oxygen (PaO2:FiO(2)) ratio were calculated. There were significant increases in SVRI (P < 0.05) post-MHI and diastolic arterial pressure (P < 0.01)during MHI. C-dyn increased post-MHI (P < 0.01) and was sustained at 20 minutes post-MHI (P < 0.01). Subjects with an intrapulmonary cause of lung disease had a significant decrease (P = 0.02) in PaO2:FiO(2), and those with extrapulmonary causes of lung disease had a significant increase (P < 0.001) in PaO2:FiO(2) post-MHI. In critically ill patients, MHI resulted in an improvement in lung mechanics and an improvement in gas exchange in patients with lung disease due to extrapulmonary events and did not result in impairment of the cardiovascular system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Streptococcus pyogenes isolates from a tropical region and a subtropical region of Australia with high and low incidences of severe streptococcal diseases, respectively, were analyzed for speA, speB, and speC gene distributions and NAD-glycohydrolase expression. No direct correlation of these characteristics with a propensity to cause invasive diseases was observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concept of a basic (i.e., essential) medical emergency kit suitable for a general dental practitioner varies somewhat between different authorities. A practitioner's choice is also dependant on the proximity of medical aid and the nature of the dental practice. Over recent years the trend has been to restrict the items to a minimum, in the interest of both common sense and safety, for example, just oxygen, adrenaline 1:1000, an oral carbohydrate source, glyceryl trinitrate and aspirin as first options. Ancillary equipment should include an oxygen therapy facemask, a pocket mask and a set of oral (Guedel) airways. Two further medication options for consideration are an aerosol bronchodilator and, in certain circumstances, an injectable antihypoglycaemic agent. This paper provides a selective overview of the subject. An absolute necessity is for dentists to be competent in Basic Life Support skills, and to maintain a complete and current medical history for all patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The two steps of nitrification, namely the oxidation of ammonia to nitrite and nitrite to nitrate, often need to be considered separately in process studies. For a detailed examination, it is desirable to monitor the two-step sequence using online measurements. In this paper, the use of online titrimetric and off-gas analysis (TOGA) methods for the examination of the process is presented. Using the known reaction stoichiometry, combination of the measured signals (rates of hydrogen ion production, oxygen uptake and carbon dioxide transfer) allows the determination of the three key process rates, namely the ammonia consumption rate, the nitrite accumulation rate and the nitrate production rate. Individual reaction rates determined with the TOGA sensor under a number of operation conditions are presented. The rates calculated directly from the measured signals are compared with those obtained from offline liquid sample analysis. Statistical analysis confirms that the results from the two approaches match well. This result could not have been guaranteed using alternative online methods. As a case study, the influences of pH and dissolved oxygen (DO) on nitrite accumulation are tested using the proposed method. It is shown that nitrite accumulation decreased with increasing DO and pH. Possible reasons for these observations are discussed. (C) 2003 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Talvez não seja nenhum exagero afirmar que há quase um consenso entre os praticantes da Termoeconomia de que a exergia, ao invés de só entalpia, seja a magnitude Termodinâmica mais adequada para ser combinada com o conceito de custo na modelagem termoeconômica, pois esta leva em conta aspectos da Segunda Lei da Termodinâmica e permite identificar as irreversibilidades. Porém, muitas vezes durante a modelagem termoeconômica se usa a exergia desagregada em suas parcelas (química, térmica e mecânica), ou ainda, se inclui a neguentropia que é um fluxo fictício, permitindo assim a desagregação do sistema em seus componentes (ou subsistemas) visando melhorar e detalhar a modelagem para a otimização local, diagnóstico e alocação dos resíduos e equipamentos dissipativos. Alguns autores também afirmam que a desagregação da exergia física em suas parcelas (térmica e mecânica) permite aumentar a precisão dos resultados na alocação de custos, apesar de fazer aumentar a complexidade do modelo termoeconômico e consequentemente os custos computacionais envolvidos. Recentemente alguns autores apontaram restrições e possíveis inconsistências do uso da neguentropia e deste tipo de desagregação da exergia física, propondo assim alternativas para o tratamento de resíduos e equipamentos dissipativos que permitem a desagregação dos sistemas em seus componentes. Estas alternativas consistem, basicamente, de novas propostas de desagregação da exergia física na modelagem termoeconômica. Sendo assim, este trabalho tem como objetivo avaliar as diferentes metodologias de desagregação da exergia física para a modelagem termoeconômica, tendo em conta alguns aspectos como vantagens, restrições, inconsistências, melhoria na precisão dos resultados, aumento da complexidade e do esforço computacional e o tratamento dos resíduos e equipamentos dissipativos para a total desagregação do sistema térmico. Para isso, as diferentes metodologias e níveis de desagregação da exergia física são aplicados na alocação de custos para os produtos finais (potência líquida e calor útil) em diferentes plantas de cogeração considerando como fluido de trabalho tanto o gás ideal bem como o fluido real. Plantas essas com equipamentos dissipativos (condensador ou válvula) ou resíduos (gases de exaustão da caldeira de recuperação). Porém, foi necessário que uma das plantas de cogeração não incorporasse equipamentos dissipativos e nem caldeira de recuperação com o intuito de avaliar isoladamente o efeito da desagregação da exergia física na melhoria da precisão dos resultados da alocação de custos para os produtos finais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Portugal has the largest LPG (Liquefied Petroleum Gas) share of primary energy demand in the EU (about 5%). Due to the increasing international cost of LPG in the last years and the high price sensitivity of the consumers the preference for substitute energy sources in new and existing consumers has been increasing. To select the kind of energy, some consumer estimate and compare the total costs while others follow agents (equipment sellers) recommendations. It takes time to build agents perception about the most advantageous source of energy, which is seen as an important resource that drives client resource accumulation and retention. Marketing strategies have to take into consideration some market dynamic effects derived from the accumulation and depletion of these resources. A simple system dynamics model was built, combined with Economic Value Added framework, to evaluate some pricing strategies under different scenarios of LPG international cost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Portugal has the largest LPG (Liquefied Petroleum Gas) share of primary energy demand in the EU (about 5%). Due to the increasing international cost of LPG in the last years and the high price sensitivity of the consumers the preference for substitute energy sources in new and existing consumers has been increasing. To select the kind of energy, some consumer estimate and compare the total costs while others follow agents (equipment sellers) recommendations. It takes time to build agents perception about the most advantageous source of energy, which is seen as an important resource that drives client resource accumulation and retention. Marketing strategies have to take into consideration some market dynamic effects derived from the accumulation and depletion of these resources. A simple system dynamics model was built, combined with Economic Value Added framework, to evaluate some pricing strategies under different scenarios of LPG international cost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Demand for power is growing every day, mainly due to emerging economies in countries such as China, Russia, India, and Brazil. During the last 50 years steam pressure and temperature in power plants have been continuously raised to improve thermal efficiency. Recent efforts to improve efficiency leads to the development of a new generation of heat recovery steam generator, where the Benson once-through technology is applied to improve the thermal efficiency. The main purpose of this paper is to analyze the mechanical behavior of a high pressure superheater manifold by applying finite element modeling and a finite element analysis with the objective of analyzing stress propagation, leading to the study of damage mechanism, e.g., uniaxial fatigue, uniaxial creep for life prediction. The objective of this paper is also to analyze the mechanical properties of the new high temperature resistant materials in the market such as 2Cr Bainitic steels (T/P23 and T/P24) and also the 9-12Cr Martensitic steels (T/P91, T/P92, E911, and P/T122). For this study the design rules for construction of power boilers to define the geometry of the HPSH manifold were applied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The best places to locate the Gas Supply Units (GSUs) on a natural gas systems and their optimal allocation to loads are the key factors to organize an efficient upstream gas infrastructure. The number of GSUs and their optimal location in a gas network is a decision problem that can be formulated as a linear programming problem. Our emphasis is on the formulation and use of a suitable location model, reflecting real-world operations and constraints of a natural gas system. This paper presents a heuristic model, based on lagrangean approach, developed for finding the optimal GSUs location on a natural gas network, minimizing expenses and maximizing throughput and security of supply.The location model is applied to the Iberian high pressure natural gas network, a system modelised with 65 demand nodes. These nodes are linked by physical and virtual pipelines – road trucks with gas in liquefied form. The location model result shows the best places to locate, with the optimal demand allocation and the most economical gas transport mode: by pipeline or by road truck.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A major determinant of the level of effective natural gas supply is the ease to feed customers, minimizing system total costs. The aim of this work is the study of the right number of Gas Supply Units – GSUs - and their optimal location in a gas network. This paper suggests a GSU location heuristic, based on Lagrangean relaxation techniques. The heuristic is tested on the Iberian natural gas network, a system modelized with 65 demand nodes, linked by physical and virtual pipelines. Lagrangean heuristic results along with the allocation of loads to gas sources are presented, using a 2015 forecast gas demand scenario.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Natural gas industry has been confronted with big challenges: great growth in demand, investments on new GSUs – gas supply units, and efficient technical system management. The right number of GSUs, their best location on networks and the optimal allocation to loads is a decision problem that can be formulated as a combinatorial programming problem, with the objective of minimizing system expenses. Our emphasis is on the formulation, interpretation and development of a solution algorithm that will analyze the trade-off between infrastructure investment expenditure and operating system costs. The location model was applied to a 12 node natural gas network, and its effectiveness was tested in five different operating scenarios.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we study the optimal natural gas commitment for a known demand scenario. This study implies the best location of GSUs to supply all demands and the optimal allocation from sources to gas loads, through an appropriate transportation mode, in order to minimize total system costs. Our emphasis is on the formulation and use of a suitable optimization model, reflecting real-world operations and the constraints of natural gas systems. The mathematical model is based on a Lagrangean heuristic, using the Lagrangean relaxation, an efficient approach to solve the problem. Computational results are presented for Iberian and American natural gas systems, geographically organized in 65 and 88 load nodes, respectively. The location model results, supported by the computational application GasView, show the optimal location and allocation solution, system total costs and suggest a suitable gas transportation mode, presented in both numerical and graphic supports.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To comply with natural gas demand growth patterns and Europe´s import dependency, the gas industry needs to organize an efficient upstream infrastructure. The best location of Gas Supply Units – GSUs and the alternative transportation mode – by phisical or virtual pipelines, are the key of a successful industry. In this work we study the optimal location of GSUs, as well as determining the most efficient allocation from gas loads to sources, selecting the best transportation mode, observing specific technical restrictions and minimizing system total costs. For the location of GSUs on system we use the P-median problem, for assigning gas demands nodes to source facilities we use the classical transportation problem. The developed model is an optimisation-based approach, based on a Lagrangean heuristic, using Lagrangean relaxation for P-median problems – Simple Lagrangean Heuristic. The solution of this heuristic can be improved by adding a local search procedure - the Lagrangean Reallocation Heuristic. These two heuristics, Simple Lagrangean and Lagrangean Reallocation, were tested on a realistic network - the primary Iberian natural gas network, organized with 65 nodes, connected by physical and virtual pipelines. Computational results are presented for both approaches, showing the location gas sources and allocation loads arrangement, system total costs and gas transportation mode.