964 resultados para Fixed effect
Resumo:
This article reports on a detailed empirical study of the way narrative task design influences the oral performance of second-language (L2) learners. Building on previous research findings, two dimensions of narrative design were chosen for investigation: narrative complexity and inherent narrative structure. Narrative complexity refers to the presence of simultaneous storylines; in this case, we compared single-story narratives with dual-story narratives. Inherent narrative structure refers to the order of events in a narrative; we compared narratives where this was fixed to others where the events could be reordered without loss of coherence. Additionally, we explored the influence of learning context on performance by gathering data from two comparable groups of participants: 60 learners in a foreign language context in Teheran and 40 in an L2 context in London. All participants recounted two of four narratives from cartoon pictures prompts, giving a between-subjects design for narrative complexity and a within-subjects design for inherent narrative structure. The results show clearly that for both groups, L2 performance was affected by the design of the task: Syntactic complexity was supported by narrative storyline complexity and grammatical accuracy was supported by an inherently fixed narrative structure. We reason that the task of recounting simultaneous events leads learners into attempting more hypotactic language, such as subordinate clauses that follow, for example, while, although, at the same time as, etc. We reason also that a tight narrative structure allows learners to achieve greater accuracy in the L2 (within minutes of performing less accurately on a loosely structured narrative) because the tight ordering of events releases attentional resources that would otherwise be spent on finding connections between the pictures. The learning context was shown to have no effect on either accuracy or fluency but an unexpectedly clear effect on syntactic complexity and lexical diversity. The learners in London seem to have benefited from being in the target language environment by developing not more accurate grammar but a more diverse resource of English words and syntactic choices. In a companion article (Foster & Tavakoli, 2009) we compared their performance with native-speaker baseline data and see that, in terms of nativelike selection of vocabulary and phrasing, the learners in London are closing in on native-speaker norms. The study provides empirical evidence that L2 performance is affected by task design in predictable ways. It also shows that living within the target language environment, and presumably using the L2 in a host of everyday tasks outside the classroom, confers a distinct lexical advantage, not a grammatical one.
Resumo:
An analysis of the attribution of past and future changes in stratospheric ozone and temperature to anthropogenic forcings is presented. The analysis is an extension of the study of Shepherd and Jonsson (2008) who analyzed chemistry-climate simulations from the Canadian Middle Atmosphere Model (CMAM) and attributed both past and future changes to changes in the external forcings, i.e. the abundances of ozone-depleting substances (ODS) and well-mixed greenhouse gases. The current study is based on a new CMAM dataset and includes two important changes. First, we account for the nonlinear radiative response to changes in CO2. It is shown that over centennial time scales the radiative response in the upper stratosphere to CO2 changes is significantly nonlinear and that failure to account for this effect leads to a significant error in the attribution. To our knowledge this nonlinearity has not been considered before in attribution analysis, including multiple linear regression studies. For the regression analysis presented here the nonlinearity was taken into account by using CO2 heating rate, rather than CO2 abundance, as the explanatory variable. This approach yields considerable corrections to the results of the previous study and can be recommended to other researchers. Second, an error in the way the CO2 forcing changes are implemented in the CMAM was corrected, which significantly affects the results for the recent past. As the radiation scheme, based on Fomichev et al. (1998), is used in several other models we provide some description of the problem and how it was fixed.
Resumo:
We apply a new parameterisation of the Greenland ice sheet (GrIS) feedback between surface mass balance (SMB: the sum of surface accumulation and surface ablation) and surface elevation in the MAR regional climate model (Edwards et al., 2014) to projections of future climate change using five ice sheet models (ISMs). The MAR (Modèle Atmosphérique Régional: Fettweis, 2007) climate projections are for 2000–2199, forced by the ECHAM5 and HadCM3 global climate models (GCMs) under the SRES A1B emissions scenario. The additional sea level contribution due to the SMB– elevation feedback averaged over five ISM projections for ECHAM5 and three for HadCM3 is 4.3% (best estimate; 95% credibility interval 1.8–6.9 %) at 2100, and 9.6% (best estimate; 95% credibility interval 3.6–16.0 %) at 2200. In all results the elevation feedback is significantly positive, amplifying the GrIS sea level contribution relative to the MAR projections in which the ice sheet topography is fixed: the lower bounds of our 95% credibility intervals (CIs) for sea level contributions are larger than the “no feedback” case for all ISMs and GCMs. Our method is novel in sea level projections because we propagate three types of modelling uncertainty – GCM and ISM structural uncertainties, and elevation feedback parameterisation uncertainty – along the causal chain, from SRES scenario to sea level, within a coherent experimental design and statistical framework. The relative contributions to uncertainty depend on the timescale of interest. At 2100, the GCM uncertainty is largest, but by 2200 both the ISM and parameterisation uncertainties are larger. We also perform a perturbed parameter ensemble with one ISM to estimate the shape of the projected sea level probability distribution; our results indicate that the probability density is slightly skewed towards higher sea level contributions.
Resumo:
Initializing the ocean for decadal predictability studies is a challenge, as it requires reconstructing the little observed subsurface trajectory of ocean variability. In this study we explore to what extent surface nudging using well-observed sea surface temperature (SST) can reconstruct the deeper ocean variations for the 1949–2005 period. An ensemble made with a nudged version of the IPSLCM5A model and compared to ocean reanalyses and reconstructed datasets. The SST is restored to observations using a physically-based relaxation coefficient, in contrast to earlier studies, which use a much larger value. The assessment is restricted to the regions where the ocean reanalyses agree, i.e. in the upper 500 m of the ocean, although this can be latitude and basin dependent. Significant reconstruction of the subsurface is achieved in specific regions, namely region of subduction in the subtropical Atlantic, below the thermocline in the equatorial Pacific and, in some cases, in the North Atlantic deep convection regions. Beyond the mean correlations, ocean integrals are used to explore the time evolution of the correlation over 20-year windows. Classical fixed depth heat content diagnostics do not exhibit any significant reconstruction between the different existing observation-based references and can therefore not be used to assess global average time-varying correlations in the nudged simulations. Using the physically based average temperature above an isotherm (14 °C) alleviates this issue in the tropics and subtropics and shows significant reconstruction of these quantities in the nudged simulations for several decades. This skill is attributed to the wind stress reconstruction in the tropics, as already demonstrated in a perfect model study using the same model. Thus, we also show here the robustness of this result in an historical and observational context.
Resumo:
This paper examines whether European Monetary Union (EMU) countries share fairly the effect of their membership in Eurozone (EZ) or whether are winners and losers in this ''Euro-game''. By using panel data of 27 European Union (EU) Member States for the period 2001-2012 in the context of a gravity model, we focus on estimating the Euro’s effect on bilateral trade and we detect whether this effect differs across the Member States of EZ. Two estimation methods are applied: Pooled OLS estimator and Fixed Effects estimator. The empirical results come to the conclusion that the individual country effects differ and are statistically significant, indicating that EMU’s effect on trade differs across the Member States of EZ. The overall effect of the Euro is statistically insignificant, regardless the estimation method, demonstrating that the common European currency may have no effect on bilateral trade.
Resumo:
The present study investigated how the timing of the administration of estradiol benzoate (EB) impacted the synchronization of ovulation in fixed-time artificial insemination protocols of cattle. To accomplish this, two experiments were conducted, with EB injection occurring at different times: at withdrawal of the progesterone-releasing (N) intravaginal device or 24 h later. The effectiveness of these times was compared by examining ovarian follicular dynamics (Experiment 1, n = 30) and conception rates (Experiment 2, n = 504). In Experiment 1, follicular dynamics was performed in 30 Nelore cows (Bos indicus) allocated into two groups. on a random day of the estrous cycle (Day 0), both groups received 2 mg of EB i.m. and a P4-releasing intravaginal device, which was removed on Day 8, when 400 IU of eCG and 150 mu g of PGF were administered. The control group (G-EB9; n = 15) received 1 mg of EB on Day 9, while Group EB8 (G-EB8; n = 15) received the same dose a day earlier. Ovarian ultrasonographic evaluations were performed every 8 h after device removal until ovulation. The timing of EB administration (Day 8 compared with Day 9) did affect the interval between P4 device removal to ovulation (59.4 +/- 2.0 h compared with 69.3 +/- 1.7 h) and maximum diameter of dominant (1.54 +/- 0.06 a cm compared with 1.71 +/- 0.05 b cm, P = 0.03) and ovulatory (1.46 +/- 0.05 a cm compared with 1.58 +/- 0.04 b cm, P < 0.01) follicles. In Experiment 2,504 suckling cows received the same treatment described in Experiment 1, but insemination was performed as follows: Group EB8-AI48h (G-EB8-AI48h; n = 119) and Group EB8-AI54h (G-EB8-AI54h; n = 134) received 1 mg of EB on Day 8 and FrAI was performed, respectively, 48 or 54 h after P4 device removal. Group EB9-AI48h (G-EB9-AI48h; n = 126) and Group EB9-AI54h (G-EB9-AI54h n = 125) received the same treatments and underwent the same FTAI protocols as G-EB8-AI48h and G-EB8-AI54h, respectively; however, EB was administered on Day 9. Conception rates were greater (P < 0.05) in G-EB9-AI54h 163.2% (79/125) a], G-EB9-AI48h [58.7% (74/126) a] and G-EB8-AI48h [58.8% (70/119) a] than in G-EB8-AI54h [34.3% (46/134) b]. We concluded that when EB administration occurred at device withdrawal (D8), the interval to ovulation shortened and dominant and ovulatory follicle diameters decreased. Furthermore, when EB treatment was performed 24 h after device removal, FTAI conducted at either 48 or 54 h resulted in similar conception rates. However, EB treatment on the same day as device withdrawal resulted in a lesser conception rate when FTAI was conducted 54 h after device removal. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Recent studies have demonstrated that sheath dynamics in plasma immersion ion implantation (PIII) is significantly affected by an external magnetic field, especially in the case when the magnetic field is parallel to the workpiece surface or intersects it at small angles. In this work we report the results from two-dimensional, particle-in-cell (PIC) computer simulations of magnetic field enhanced plasma immersion implantation system at different bias voltages. The simulations begin with initial low-density nitrogen plasma, which extends with uniform density through a grounded cylindrical chamber. Negative bias voltage is applied to a cylindrical target located on the axis of the vacuum chamber. An axial magnetic field is created by a solenoid installed inside the target holder. A set of simulations at a fixed magnetic field of 0.0025 T at the target surface is performed. Secondary electron emission from the target subjected to ion bombardment is also included. It is found that the plasma density around the cylindrical target increases because of intense background gas ionization by the electrons drifting in the crossed E x B fields. Suppression of the sheath expansion and increase of the implantation current density in front of the high-density plasma region are observed. The effect of target bias on the sheath dynamics and implantation current of the magnetic field enhanced PIII is discussed. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
The objective was to determine whether the presence of fertility-associated antigen (FAA) on sperm collected from Nelore (Bos indicus) bulls can be used to assess potential fertility of sperm for use at first-service fixed-time AI (TAI). Six Nelore bulls were selected based on FAA status (FAA-negative: N = 3; FAA-positive: N = 3) and the ability to produce neat semen with >= 70% morphologically normal sperm and 60% estimated progressive motility before cryopmservation. In Experiment 1, suckled multiparous Nelore cows (N = 835) were evaluated for body condition score (BCS) and received an intravaginal progesterone device (CIDR) and 2.0 mg of estradiol benzoate (Day 0). on Day 9 the CIDR was removed, 12.5 mg of PGF(2 alpha) and 0.5 mg of estradiol cypionate were administered, and calves were removed for 48 h. All cows received TAI on Day II (48 h after CIDR removal). Pregnancy per TAI (P/TAI) was not different between FAA-positive and FAA-negative bulls (41.5% vs. 39.3%, respectively). There was an effect of AI technician on P/TAI (36.0% vs. 43.9%; P < 0.05) and BCS tended to affect P/TAI (P = 0.09), as cows with BCS >= 2.75 were 1.4 times more likely to become pregnant compared with cows with BCS < 2.75. In Experiment 2, nulliparous Nelore heifers (N = 617) were evaluated for BCS and received a CIDR and estradiol benzoate (2.0 mg) on Day 0. on Day 7, all heifers received PGF(2 alpha) (12.5 mg). on Day 9, CIDR inserts were removed and all heifers received estradiol cypionate (0.6 mg) and 200 IU eCG. All heifers received TAI on Day 11 (48 h after CIDR removal). Pregnancy/TAI was different (P = 0.04) between FAA-positive and FAA-negative bulls (33.7% vs. 40.7%, respectively). Presence of FAA on sperm was unsuccessful in assessing the potential fertility of sperm for use in TAI. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
In Exp. 1, we evaluated the effects of 2 lengths of progesterone exposure [CIDR (controlled intravaginal drug release); 7 vs. 14 d] before a modified CO-Synch protocol [50.0-mu g injection of GnRH 6.5 d before a 25.0-mg injection of PGF(2 alpha) followed by another injection of GnRH and fixed-time AI (TAI) 2 d after PGF(2 alpha)], with or without temporary weaning (TW) before GnRH treatments, on fertility of suckled multiparous Bos indicus cows (n = 283) and on calf performance. Timed AI pregnancy rates for cows receiving 7 d CIDR + TW, 7 d CIDR, 14 d CIDR + TW, and 14 d CIDR were 53, 47, 46, and 41%, respectively (P > 0.10). Calves submitted to two 48-h TW 6 d apart had decreased mean BW at 240 d (187.9 +/- 2.7 vs. 195.5 +/- 2.7 kg; P < 0.05), but BW at 420 d was not affected by TW (240.1 +/- 5.1 kg). In Exp. 2, we evaluated the effect of no treatment and treatment with or without a CIDR insert between GnRH and PGF(2 alpha) treatments of a modified CO-Synch protocol on pregnancy rate to TAI, and throughout a 90-d breeding season in suckled multiparous Bos indicus cows (n = 453). The inclusion of a CIDR between first GnRH and PGF(2 alpha) treatments of a modified CO-Synch protocol did not improve pregnancy rate (29 and 33% for cows receiving CO-Synch + CIDR and CO-Synch protocol, respectively), and cycling cows had poorer TAI pregnancy rates than anestrous cows treated with either synchronization protocol (21.7 vs. 40.7%; P < 0.05). However, regardless of treatment with CIDR, cows submitted to TAI protocol had greater (P < 0.05) pregnancy rates at 30 (54.8 vs. 11.2%), 60 (72.1 vs. 38.8%), and 90 d (82.0 vs. 57.9%) of breeding season than untreated cows.
Resumo:
The objective of the present experiment was to assess the effects of temperament on pregnancy rates to fixed-time AI (FTAI) in Bos indicus beef cows. A total of 761 multiparous lactating Nelore cows, originated from 4 different commercial cow-calf ranches, were evaluated for BCS and temperament at the time of FTAI (day 0). Temperament was assessed by chute score and exit velocity. Further, individual exit score was calculated by dividing exit velocity results into quintiles and assigning cows with a score from 1 to 5 (exit score: 1 = slowest cows; 5 = fastest cow). Temperament scores were calculated by averaging cow chute score and exit score. Cows were also classified for temperament type according to temperament score (<= 3 = adequate temperament, >3 = excitable temperament). Pregnancy status was verified by detecting a viable conceptus with rectal ultrasonography approximately 40 days after FTAI. Chute score, exit velocity, and temperament score were not correlated to BCS (P>0.31). Hence, BCS did not differ (P=0.30) according to temperament type (4.13 vs. 4.09 for cows with excitable and adequate temperament, respectively; SEM = 0.070). Pregnancy rates to FTAI tended to be negatively affected by temperament score (P=0.08), whereas the probability of cows becoming pregnant to FTAI was negatively associated with temperament score (linear effect, P<0.01). Accordingly, pregnancy rates were reduced (P=0.05) in cows with excitable temperament compared to cows with adequate temperament (35.3 vs. 42.8% of pregnant cows/total cows, respectively; SEM = 2.85). Pregnancy rates to FTAI were not affected by chute score (P=0.25), although the probability of cows becoming pregnant to FTAI tended to be negatively associated with chute score (linear effect, P=0.07). Pregnancy rates to FTAI were negatively affected by exit score (P=0.05), and the probability of cows becoming pregnant to FTAI was negatively associated with exit score and with actual exit velocity (linear effects, P<0.01). Results from this experiment indicate that excitable temperament is detrimental to pregnancy rates of B. indicus cows assigned to an estrus synchronization + FTAI protocol. Published by Elsevier B.V.
Resumo:
PURPOSE. Amniotic membrane transplantation (AMT) has been used as a graft or as a dressing in ocular surface reconstruction, facilitating epithelization, maintaining normal epithelial phenotype, and reducing inflammation, vascularization, and scarring. The corneal transparency is due, at least in part, to the arrangement in orthogonal lamellae of collagen fibrils, surrounded by proteoglycans (PGs). These PGs regulate fibrilogenesis, the matrix assembly, and ultimately the corneal transparency. The purpose of the present study was to investigate the effects of AMT upon the corneal PGs after severe limbal injury.METHODS. Experiments were performed on the right corneas of 22 New Zealand female albino rabbits, and their left corneas were used as matched controls. These animals were divided into 3 groups: G1 (n = 10): total peritomy and keratolimbectomy, followed by application of 0.5 M NaOH; G2 (n = 10): submitted to the same trauma as G1, and treated by AMT; G3: no trauma, only AMT (n = 2). The right corneas of G2 and G3 were covered by DMSO 4 cryopreserved human amniotic membrane, fixed by interrupted 9-0 mononylon sutures, with its stromal face toward the ocular surface. After 7 or 30 days, the corneas were removed and PGs were extracted.RESULTS. Normal corneas contained approximately 9 mg of PGs per gram of dry tissue. AMT on intact cornea (G3) did not cause any changes in the concentration of PGs. In contrast, injured corneas contained much less PGs, both on the seventh and on the 30th day posttrauma. The PG concentration was even lower in injured corneas treated by AMT. This decrease was due almost exclusively to dermatan sulfate PGs, and the structure of dermatan sulfate was also modified, indicating changes in the biosynthesis patterns.CONCLUSIONS. Although beneficial effects have been observed on clinical observation and concentration of soluble proteins after AMT, the normal PG composition of cornea was not attained, even 30 days postinjury, indicating that the normal ocular surface reconstruction, if possible, is a long-term process. (Eur J Ophthalmol 2010; 20: 290-9)
Resumo:
OBJECTIVE: The aim of this study was to evaluate histomorphometrically the effect of alveolex (Propolis 10%) on the repair of bone cavities in the calvaria of rats. MATERIALS and METHODS: A 5 mm diameter bone defect was made in the calvaria of male Wistar rats using the drill-type trephine. The defects were filled with rhBMP-21Alveolex, rhBMP-2, Alveolex, or coagulum. Twenty-eight animals with seven subjects on each were sacrificed 30 days after surgery and samples were fixed and embedded in paraffin. Histological sections stained by HE (hematoxylin and eosin) were obtained from the calvaria bone defect and analyzed by a differential point-counting method. RESULTS: Group I and II, rhBMP-21Alveolex and rhBMP-2, respectively, presented higher levels of newly formed bone than other groups (P < 0.001). There were not significant differences between groups I and II (P > 0.05). In addition, there was not significant difference between groups III and IV, Control-Coagulum and Alveolex, respectively (P > 0.05). CONCLUSION: Alveolex has increased the bone repair in calvaria defects of rats when associated to rhBMP-2, however without significant differences for rhBMP-2 isolated group; Alveolex isolated group showed the lowest levels of newly formed bone with no significant differences to coagulum group (control). Microsc. Res. Tech. 75: 36-41, 2012. (C) 2011 Wiley Periodicals, Inc.
Resumo:
Purpose: This three-dimensional finite element analysis study evaluated the effect of different material combinations on stress distribution within metal-ceramic and all-ceramic single implant-supported prostheses. Materials and Methods: Three-dimensional finite element models reproducing a segment of the maxilla with a missing left first premolar were created. Five groups were established to represent different superstructure materials: GP, porcelain fused to gold alloy; GR, modified composite resin fused to gold alloy; TP, porcelain fused to titanium; TR, modified composite resin fused to titanium; and ZP, porcelain fused to zirconia. A 100-N vertical force was applied to the contact points of the crowns. All models were fixed in the superior region of bone tissue and in the mesial and distal faces of the maxilla section. Stress maps were generated by processing with finite element software. Results: Stress distribution and stress values of supporting bone were similar for the GP, GR, TP, and ZP models (1,574.3 MPa, 1,574.3 MPa, 1,574.3 MPa, and 1,574.2 MPa, respectively) and different for the TR model (1,838.3 MPa). The ZP model transferred less stress to the retention screw (785 MPa) than the other groups (939 MPa for GP, 961 MPa for GR, 1,010 MPa for TP, and 1,037 MPa for TR). Conclusion: The use of different materials to fabricate a superstructure for a single implant-supported prosthesis did not affect the stress distribution in the supporting bone. The retention screw received less stress when a combination of porcelain and zirconia was used. Int J Oral Maxillofac Implants 2011;26:1202-1209
Resumo:
Purpose: Three-dimensional finite element analysis was used to evaluate the effect of vertical and angular misfit in three-piece implant-supported screw-retained fixed prostheses on the biomechanical response in the peri-implant bone, implants, and prosthetic components. Materials and Methods: Four three-dimensional models were fabricated to represent a right posterior mandibular section with one implant in the region of the second premolar (2PM) and another in the region of the second molar (2M). The implants were splinted by a three-piece implant-supported metal-ceramic prosthesis and differed according to the type of misfit, as represented by four different models: Control = prosthesis with complete fit to the implants; UAM (unilateral angular misfit) = prosthesis presenting unilateral angular misfit of 100 pm in the mesial region of the 2M; UVM (unilateral vertical misfit) = prosthesis presenting unilateral vertical misfit of 100 pm in the mesial region of the 2M; and TVM (total vertical misfit) = prosthesis presenting total vertical misfit of 100 pm in the platform of the framework in the 2M. A vertical load of 400 N was distributed and applied on 12 centric points by the software Ansys, ie, a vertical load of 150 N was applied to each molar in the prosthesis and a vertical load of 100 N was applied at the 2PM. Results: The stress values and distribution in peri-implant bone tissue were similar for all groups. The models with misfit exhibited different distribution patterns and increased stress magnitude in comparison to the control. The highest stress values in group UAM were observed in the implant body and retention screw. The groups UVM and TVM exhibited high stress values in the platform of the framework and the implant hexagon, respectively. Conclusions: The three types of misfit influenced the magnitude and distribution of stresses. The influence of misfit on peri-implant bone tissue was modest. Each type of misfit increased the stress values in different regions of the system. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:788-796