967 resultados para Extraction methods


Relevância:

30.00% 30.00%

Publicador:

Resumo:

High performance liquid chromatography (HPLC) is the reference method for measuring concentrations of antimicrobials in blood. This technique requires careful sample preparation. Protocols using organic solvents and/or solid extraction phases are time consuming and entail several manipulations, which can lead to partial loss of the determined compound and increased analytical variability. Moreover, to obtain sufficient material for analysis, at least 1 ml of plasma is required. This constraint makes it difficult to determine drug levels when blood sample volumes are limited. However, drugs with low plasma-protein binding can be reliably extracted from plasma by ultra-filtration with a minimal loss due to the protein-bound fraction. This study validated a single-step ultra-filtration method for extracting fluconazole (FLC), a first-line antifungal agent with a weak plasma-protein binding, from plasma to determine its concentration by HPLC. Spiked FLC standards and unknowns were prepared in human and rat plasma. Samples (240 microl) were transferred into disposable microtube filtration units containing cellulose or polysulfone filters with a 5 kDa cut-off. After centrifugation for 60 min at 15000g, FLC concentrations were measured by direct injection of the filtrate into the HPLC. Using cellulose filters, low molecular weight proteins were eluted early in the chromatogram and well separated from FLC that eluted at 8.40 min as a sharp single peak. In contrast, with polysulfone filters several additional peaks interfering with the FLC peak were observed. Moreover, the FLC recovery using cellulose filters compared to polysulfone filters was higher and had a better reproducibility. Cellulose filters were therefore used for the subsequent validation procedure. The quantification limit was 0.195 mgl(-1). Standard curves with a quadratic regression coefficient > or = 0.9999 were obtained in the concentration range of 0.195-100 mgl(-1). The inter and intra-run accuracies and precisions over the clinically relevant concentration range, 1.875-60 mgl(-1), fell well within the +/-15% variation recommended by the current guidelines for the validation of analytical methods. Furthermore, no analytical interference was observed with commonly used antibiotics, antifungals, antivirals and immunosuppressive agents. Ultra-filtration of plasma with cellulose filters permits the extraction of FLC from small volumes (240 microl). The determination of FLC concentrations by HPLC after this single-step procedure is selective, precise and accurate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Plasma catecholamines provide a reliable biomarker of sympathetic activity. The low circulating concentrations of catecholamines and analytical interferences require tedious sample preparation and long chromatographic runs to ensure their accurate quantification by HPLC with electrochemical detection. Published or commercially available methods relying on solid phase extraction technology lack sensitivity or require derivatization of catecholamine by hazardous reagents prior to tandem mass spectrometry (MS) analysis. Here, we manufactured a novel 96-well microplate device specifically designed to extract plasma catecholamines prior to their quantification by a new and highly sensitive ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method. Processing time, which included sample purification on activated aluminum oxide and elution, is less than 1 h per 96-well microplate. The UPLC-MS/MS analysis run time is 2.0 min per sample. This UPLC-MS/MS method does not require a derivatization step, reduces the turnaround time by 10-fold compared to conventional methods used for routine application, and allows catecholamine quantification in reduced plasma sample volumes (50-250 μL, e.g., from children and mice).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A rapid biological method for the determination of the bioavailability of naphthalene was developed and its value as an alternative to extraction-based chemical approaches demonstrated. Genetically engineered whole-cell biosensors are used to determine bioavailable naphthalene and their responses compared with results from Tenax extraction and chemical analysis. Results show a 1:1 correlation between biosensor results and chemical analyses for naphthalene-contaminated model materials and sediments, but the biosensor assay is much faster. This work demonstrates that biosensor technology can perform as well as standard chemical methods, though with some advantages including the inherent biological relevance of the response, rapid response time, and potential for field deployment. A survey of results from this work and the literature shows that bioavailability under non-equilibrium conditions nonetheless correlates well with K(oc) or K(d). A rationale is provided wherein chemical resistance is speculated to be operative.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Health professionals and policymakers aspire to make healthcare decisions based on the entire relevant research evidence. This, however, can rarely be achieved because a considerable amount of research findings are not published, especially in case of 'negative' results - a phenomenon widely recognized as publication bias. Different methods of detecting, quantifying and adjusting for publication bias in meta-analyses have been described in the literature, such as graphical approaches and formal statistical tests to detect publication bias, and statistical approaches to modify effect sizes to adjust a pooled estimate when the presence of publication bias is suspected. An up-to-date systematic review of the existing methods is lacking. METHODS/DESIGN: The objectives of this systematic review are as follows:âeuro¢ To systematically review methodological articles which focus on non-publication of studies and to describe methods of detecting and/or quantifying and/or adjusting for publication bias in meta-analyses.âeuro¢ To appraise strengths and weaknesses of methods, the resources they require, and the conditions under which the method could be used, based on findings of included studies.We will systematically search Web of Science, Medline, and the Cochrane Library for methodological articles that describe at least one method of detecting and/or quantifying and/or adjusting for publication bias in meta-analyses. A dedicated data extraction form is developed and pilot-tested. Working in teams of two, we will independently extract relevant information from each eligible article. As this will be a qualitative systematic review, data reporting will involve a descriptive summary. DISCUSSION: Results are expected to be publicly available in mid 2013. This systematic review together with the results of other systematic reviews of the OPEN project (To Overcome Failure to Publish Negative Findings) will serve as a basis for the development of future policies and guidelines regarding the assessment and handling of publication bias in meta-analyses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tässä diplomityössä tutkitaan tekniikoita, joillavesileima lisätään spektrikuvaan, ja menetelmiä, joilla vesileimat tunnistetaanja havaitaan spektrikuvista. PCA (Principal Component Analysis) -algoritmia käyttäen alkuperäisten kuvien spektriulottuvuutta vähennettiin. Vesileiman lisääminen spektrikuvaan suoritettiin muunnosavaruudessa. Ehdotetun mallin mukaisesti muunnosavaruuden komponentti korvattiin vesileiman ja toisen muunnosavaruuden komponentin lineaarikombinaatiolla. Lisäyksessä käytettävää parametrijoukkoa tutkittiin. Vesileimattujen kuvien laatu mitattiin ja analysoitiin. Suositukset vesileiman lisäykseen esitettiin. Useita menetelmiä käytettiin vesileimojen tunnistamiseen ja tunnistamisen tulokset analysoitiin. Vesileimojen kyky sietää erilaisia hyökkäyksiä tarkistettiin. Diplomityössä suoritettiin joukko havaitsemis-kokeita ottamalla huomioon vesileiman lisäyksessä käytetyt parametrit. ICA (Independent Component Analysis) -menetelmää pidetään yhtenä mahdollisena vaihtoehtona vesileiman havaitsemisessa.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Five selective serotonin reuptake inhibitors (SSRIs) have been introduced recently: citalopram, fluoxetine, fluvoxamine, paroxetine and sertraline. Although no therapeutic window has been defined for SSRIs, in contrast to tricyclic antidepressants, analytical methods for therapeutic drug monitoring of SSRIs are useful in several instances. SSRIs differ widely in their chemical structure and in their metabolism. The fact that some of them have N-demethylated metabolites, which are also SSRIs, requires that methods be available which allow therapeutic drug monitoring of the parent compounds and of these active metabolites. most procedures are based on prepurification of the SSRIs by liquid-liquid extraction before they are submitted to separation by chromatographic procedures (high-performance liquid chromatography, gas chromatography, thin layer chromatography) and detection by various detectors (UV, fluorescence, electrochemical detector, nitrogen-phosphorus detector, mass spectrometry). This literature review shows that most methods allow quantitative determination of SSRIs in plasma, in the lower ng/ml range, and that they are, therefore, suitable for therapeutic drug monitoring purposes of this category of drugs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Perceiving the world visually is a basic act for humans, but for computers it is still an unsolved problem. The variability present innatural environments is an obstacle for effective computer vision. The goal of invariant object recognition is to recognise objects in a digital image despite variations in, for example, pose, lighting or occlusion. In this study, invariant object recognition is considered from the viewpoint of feature extraction. Thedifferences between local and global features are studied with emphasis on Hough transform and Gabor filtering based feature extraction. The methods are examined with respect to four capabilities: generality, invariance, stability, and efficiency. Invariant features are presented using both Hough transform and Gabor filtering. A modified Hough transform technique is also presented where the distortion tolerance is increased by incorporating local information. In addition, methods for decreasing the computational costs of the Hough transform employing parallel processing and local information are introduced.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study aims to compare yield and quality of pequi pulp oil when applying two distinct processes: in the first, pulp drying in a tray dryer at 60ºC was combined with enzymatic treatment and pressing to oil extraction; in the second, a simple process was carried out by combining sun-drying pulp and pressing. In this study, raw pequi fruits were collected in Mato Grosso State, Brazil. The fruits were autoclaved at 121ºC and stored under refrigeration. An enzymatic extract with pectinase and CMCase activities was used for hydrolysis of pequi pulp, prior to oil extraction. The oil extractions were carried out by hydraulic pressing, with or without enzymatic incubation. The oil content in the pequi pulp (45% w/w) and the physicochemical characteristic of the oil was determined according to standard analytical methods. Free fatty acids, peroxide values, iodine and saponification indices were respectively 1.46 mgKOH/g, 2.98 meq/kg, 49.13 and 189.40. The acidity and peroxide values were lower than the obtained values in commercial oil samples, respectively 2.48 mgKOH/g and 5.22 meq/kg. Aqueous extraction has presented lower efficiency and higher oxidation of unsaturated fatty acids. On the other hand, pequi pulp pressing at room temperature has produced better quality oil. However its efficiency is still smaller than the combined enzymatic treatment and pressing process. This combined process promotes cellular wall hydrolysis and pulp viscosity reduction, contributing to at least 20% of oil yield increase by pressing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: To evaluate the safety of immediate sequential bilateral cataract extraction (ISBCE) with respect to indications, visual outcomes, complications, benefits and disadvantages. Methods: This is a retrospective review of all ISBCEs performed at Kantonsspital Winterthur, Switzerland, between April 2000 and September 2013. The case notes of 500 eyes of 250 patients were reviewed. Of these 500 eyes, 472 (94.4%) had a straight forward phacoemulsification with posterior chamber intraocular lens implantation; 21 (4.2%) had a planned extracapsular cataract extraction; 4 (0.8%) had an intracapsular cataract extraction and 3 (0.6%) had a combined phacoemulsification with trabeculectomy. Results: Over 66% of eyes achieved improved visual acuity (at least 3 Snellen lines) following ISBCE. Median preoperative best corrected visual acuity (BCVA) was 0.5 LogMAR; the interquartile range was [0.4, 1] LogMAR. At one week control the median BCVA was 0.3 LogMAR, IQR [0.1, 0.5] LogMAR. At one month the median BCVA was 0.15 LogMAR, IQR [0.05, 0.3] (p < 0.01). There were no sight-threatening intraoperative or postoperative complications observed. Conclusions: ISBCE is an effective and safe option with high degree of patient satisfaction. The relative benefits of ISBCE should be balanced against the theoretically enhanced risks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In forensic investigation of firearm-related cases, determination of the residual amount of volatile compounds remaining inside a cartridge could be useful in estimating the time since its discharge. Published approaches are based on following the decrease of selected target compounds as a function of time by using solid phase micro-extraction (SPME). Naphthalene, as well as an unidentified decomposition product of nitrocellulose (referred to as "TEA2"), are usually employed for this purpose. However, reliability can be brought into question given their high volatility and the low reproducibility of their extracted quantities. In order to identify alternatives and therefore develop improved dating methods, an extensive study on the composition and variability of volatile residues in nine different types of cartridges was carried out. Analysis was performed using headspace sorptive extraction (HSSE), which is a more exhaustive technique compared to SPME. 166 compounds were identified (several of which for the first time), and it was observed that the final compositional characteristics of each residue were strongly dependent on its source. Variability of single identified compounds within and between different types of cartridge, as well as their evolution over time, was also studied. Many explosion products containing up to 4 aromatic rings were found to be globally present in high proportions amongst residues. 27 of them (excluding naphthalene) also presented detectable decreases during the first 24 h. Therefore, they could be used as complementary target analytes in future dating methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents a comparison between three analytical methods developed for the simultaneous determination of eight quinolones regulated by the European Union (marbofloxacin, ciprofloxacin, danofloxacin, enrofloxacin, difloxacin, sarafloxacin, oxolinic acid and flumequine) in pig muscle, using liquid chromatography with fluorescence detection (LC-FD), liquid chromatography-mass spectrometry (LC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS). The procedures involve an extraction of the quinolones from the tissues, a step for clean-up and preconcentration of the analytes by solid-phase extraction and a subsequent liquid chromatographic analysis. The limits of detection of the methods ranged from 0.1 to 2.1 ng g−1 using LC-FD, from 0.3 to 1.8 using LC-MS and from 0.2 to 0.3 using LC-MS/MS, while inter- and intra-day variability was under 15 % in all cases. Most of those data are notably lower than the maximum residue limits established by the European Union for quinolones in pig tissues. The methods have been applied for the determination of quinolones in six different commercial pig muscle samples purchased in different supermarkets located in the city of Granada (south-east Spain).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Throughout history indigo was derived from various plants for example Dyer’s Woad (Isatis tinctoria L.) in Europe. In the 19th century were the synthetic dyes developed and nowadays indigo is mainly synthesized from by-products of fossil fuels. Indigo is a so-called vat dye, which means that it needs to be reduced to its water soluble leucoform before dyeing. Nowadays, most of the industrial reduction is performed chemically by sodium dithionite. However, this is considered environmentally unfavourable because of waste waters contaminating degradation products. Therefore there has been interest to find new possibilities to reduce indigo. Possible alternatives for the application of dithionite as the reducing agent are biologically induced reduction and electrochemical reduction. Glucose and other reducing sugars have recently been suggested as possible environmentally friendly alternatives as reducing agents for sulphur dyes and there have also been interest in using glucose to reduce indigo. In spite of the development of several types of processes, very little is known about the mechanism and kinetics associated with the reduction of indigo. This study aims at investigating the reduction and electrochemical analysis methods of indigo and give insight on the reduction mechanism of indigo. Anthraquinone as well as it’s derivative 1,8-dihydroxyanthraquinone were discovered to act as catalysts for the glucose induced reduction of indigo. Anthraquinone introduces a strong catalytic effect which is explained by invoking a molecular “wedge effect” during co-intercalation of Na+ and anthraquinone into the layered indigo crystal. The study includes also research on the extraction of plant-derived indigo from woad and the examination of the effect of this method to the yield and purity of indigo. The purity has been conventionally studied spectrophotometrically and a new hydrodynamic electrode system is introduced in this study. A vibrating probe is used in following electrochemically the leuco-indigo formation with glucose as a reducing agent.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The thermal stability of vegetable oils is an important factor that affects their quality. In this study, we investigated the thermal stability of oil and lecithin extracted from soybeans by two distinct processes: mechanical extraction (pressing) and physical extraction (solvent). Thermal analysis was used to obtain information about different methodologies of extraction. The physically extracted products proved more stable than those extracted mechanically. Raman and UV-Vis techniques were applied to underpin the discussion of process differences.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A study of the partial USEPA 3050B and total ISO 14869-1:2001 digestion methods of sediments was performed. USEPA 3050B was recommended as the simpler method with less operational risk. However, the extraction ability of the method should be taken in account for the best environmental interpretation of the results. FAAS was used to quantify metal concentrations in sediment solutions. The alternative use of ICP-OES quantification should be conditioned by a previous detailed investigation and eventual correction of the matrix effect. For the first time, the EID method was employed for the detection and correction of the matrix effect in sediment ICP-OES analysis. Finally, some considerations were made about the level of metal contamination in the area under study.