966 resultados para Data Acquisition
Resumo:
While 3D thin-slab coronary magnetic resonance angiography (MRA) has traditionally been performed using a Cartesian acquisition scheme, spiral k-space data acquisition offers several potential advantages. However, these strategies have not been directly compared in the same subjects using similar methodologies. Thus, in the present study a comparison was made between 3D coronary MRA using Cartesian segmented k-space gradient-echo and spiral k-space data acquisition schemes. In both approaches the same spatial resolution was used and data were acquired during free breathing using navigator gating and prospective slice tracking. Magnetization preparation (T(2) preparation and fat suppression) was applied to increase the contrast. For spiral imaging two different examinations were performed, using one or two spiral interleaves, during each R-R interval. Spiral acquisitions were found to be superior to the Cartesian scheme with respect to the signal-to-noise ratio (SNR) and contrast-to-noise-ratio (CNR) (both P < 0.001) and image quality. The single spiral per R-R interval acquisition had the same total scan duration as the Cartesian acquisition, but the single spiral had the best image quality and a 2.6-fold increase in SNR. The double-interleaf spiral approach showed a 50% reduction in scanning time, a 1.8-fold increase in SNR, and similar image quality when compared to the standard Cartesian approach. Spiral 3D coronary MRA appears to be preferable to the Cartesian scheme. The increase in SNR may be "traded" for either shorter scanning times using multiple consecutive spiral interleaves, or for enhanced spatial resolution.
Resumo:
A good system of preventive bridge maintenance enhances the ability of engineers to manage and monitor bridge conditions, and take proper action at the right time. Traditionally infrastructure inspection is performed via infrequent periodical visual inspection in the field. Wireless sensor technology provides an alternative cost-effective approach for constant monitoring of infrastructures. Scientific data-acquisition systems make reliable structural measurements, even in inaccessible and harsh environments by using wireless sensors. With advances in sensor technology and availability of low cost integrated circuits, a wireless monitoring sensor network has been considered to be the new generation technology for structural health monitoring. The main goal of this project was to implement a wireless sensor network for monitoring the behavior and integrity of highway bridges. At the core of the system is a low-cost, low power wireless strain sensor node whose hardware design is optimized for structural monitoring applications. The key components of the systems are the control unit, sensors, software and communication capability. The extensive information developed for each of these areas has been used to design the system. The performance and reliability of the proposed wireless monitoring system is validated on a 34 feet span composite beam in slab bridge in Black Hawk County, Iowa. The micro strain data is successfully extracted from output-only response collected by the wireless monitoring system. The energy efficiency of the system was investigated to estimate the battery lifetime of the wireless sensor nodes. This report also documents system design, the method used for data acquisition, and system validation and field testing. Recommendations on further implementation of wireless sensor networks for long term monitoring are provided.
Resumo:
Impressive developments in X-ray imaging are associated with X-ray phase contrast computed tomography based on grating interferometry, a technique that provides increased contrast compared with conventional absorption-based imaging. A new "single-step" method capable of separating phase information from other contributions has been recently proposed. This approach not only simplifies data-acquisition procedures, but, compared with the existing phase step approach, significantly reduces the dose delivered to a sample. However, the image reconstruction procedure is more demanding than for traditional methods and new algorithms have to be developed to take advantage of the "single-step" method. In the work discussed in this paper, a fast iterative image reconstruction method named OSEM (ordered subsets expectation maximization) was applied to experimental data to evaluate its performance and range of applicability. The OSEM algorithm with different subsets was also characterized by comparison of reconstruction image quality and convergence speed. Computer simulations and experimental results confirm the reliability of this new algorithm for phase-contrast computed tomography applications. Compared with the traditional filtered back projection algorithm, in particular in the presence of a noisy acquisition, it furnishes better images at a higher spatial resolution and with lower noise. We emphasize that the method is highly compatible with future X-ray phase contrast imaging clinical applications.
Resumo:
For the development and evaluation of cardiac magnetic resonance (MR) imaging sequences and methodologies, the availability of a periodically moving phantom to model respiratory and cardiac motion would be of substantial benefit. Given the specific physical boundary conditions in an MR environment, the choice of materials and power source of such phantoms is heavily restricted. Sophisticated commercial solutions are available; however, they are often relatively costly and user-specific modifications may not easily be implemented. We therefore sought to construct a low-cost MR-compatible motion phantom that could be easily reproduced and had design flexibility. A commercially available K'NEX construction set (Hyper Space Training Tower, K'NEX Industries, Inc., Hatfield, PA) was used to construct a periodically moving phantom head. The phantom head performs a translation with a superimposed rotation, driven by a motor over a 2-m rigid rod. To synchronize the MR data acquisition with phantom motion (without introducing radiofrequency-related image artifacts), a fiberoptic control unit generates periodic trigger pulses synchronized to the phantom motion. Total material costs of the phantom are US$ < 200.00, and a total of 80 man-hours were required to design and construct the original phantom. With schematics of the present solution, the phantom reproduction may be achieved in approximately 15 man-hours. The presented MR-compatible periodically moving phantom can easily be reproduced, and user-specific modifications may be implemented. Such an approach allows a detailed investigation of motion-related phenomena in MR images.
Resumo:
A transportable, whole body indirect calorimeter, designed for use in the tropics, is described. The calorimeter was built to study energy expenditure of people having chronically or acutely low levels of food intake, and it will help to determine energy adaptations made by individuals with restricted food intake. The calorimeter comprises two units: a 27 m3 ventilated chamber connected to an office housing control and monitoring equipment. The system also allows the experimenter to assess the rate of energy expenditure by means of a ventilated hood or a baby respiration chamber. The incoming air flow rate is variable and is typically set at approximately 30 l/min. Carbon dioxide production (VCO2) and oxygen consumption (VO2) are continuously monitored by means of differential gas analysers via a computerized data acquisition unit. Gas production/consumption rates are measured with a delay of 80 s, the complete response to step changes in VCO2 or VO2 consumption being calculated over 15 min using the rate of change terms in the gas exchange equations. The total electrical power required for the whole system is 12 kW. The calorimeter has been functioning for nearly 4 years in a rural village of The Gambia during which ambient temperatures have ranged from 16 to 44 degrees C and dewpoints from -8 to 24 degrees C. The performance and accuracy of the calorimeter were tested using 20 per cent CO2 in N2 infusion and butane burning. Agreement between the theoretical and the measured values was found to be 99 per cent for VO2 and 100 per cent for VCO2 with a precision for both gases of +/- 10 ml/min over a 1-h period.
Resumo:
It is well established that cancer cells can recruit CD11b(+) myeloid cells to promote tumor angiogenesis and tumor growth. Increasing interest has emerged on the identification of subpopulations of tumor-infiltrating CD11b(+) myeloid cells using flow cytometry techniques. In the literature, however, discrepancies exist on the phenotype of these cells (Coffelt et al., Am J Pathol 2010;176:1564-1576). Since flow cytometry analysis requires particular precautions for accurate sample preparation and trustable data acquisition, analysis, and interpretation, some discrepancies might be due to technical reasons rather than biological grounds. We used the syngenic orthotopic 4T1 mammary tumor model in immunocompetent BALB/c mice to analyze and compare the phenotype of CD11b(+) myeloid cells isolated from peripheral blood and from tumors, using six-color flow cytometry. We report here that the nonspecific antibody binding through Fc receptors, the presence of dead cells and cell doublets in tumor-derived samples concur to generate artifacts in the phenotype of tumor-infiltrating CD11b(+) subpopulations. We show that the heterogeneity of tumor-infiltrating CD11b(+) subpopulations analyzed without particular precautions was greatly reduced upon Fc block treatment, dead cells, and cell doublets exclusion. Phenotyping of tumor-infiltrating CD11b(+) cells was particularly sensitive to these parameters compared to circulating CD11b(+) cells. Taken together, our results identify Fc block treatment, dead cells, and cell doublets exclusion as simple but crucial steps for the proper analysis of tumor-infiltrating CD11b(+) cell populations.
Resumo:
Teollisuuden automaatiojärjestelmät digitalisoituvat, samalla niiden tuottaman reaaliaikaisen datan määrä kasvaa ja etenkin sen saatavuus helpottuu. Samanaikaisesti laitevalmistajan liiketoimintamallit ovat muuttumassa perinteisestä konevalmistuksesta kohti palveluntarjontaa. Muuttuneessa tilanteessa laitteiden ohjauksessa käytettäviltä järjestelmiltä vaaditaan uusia ominaisuuksia. Informaation käsittely ja jalostaminen muodostuvat tärkeiksi kilpailu-tekijöiksi. Kirjallisuusosassa on tarkasteltu, miten data jalostuu informaatioksi ja siitä edelleen tietämykseksi. Työssä myös selvitetään, miten niitä voidaan hyödyntää liiketoiminnassa. Samalla perehdytään teollisuudesta löytyviin informaatio- ja tietämysjärjestelmiin. Kokeellisessa osassa esitellään toimiva tiedonkeruu- ja raportointijärjestelmä ja tutkitaan, miten sitä tulisi kehittää, jotta se sopisi paremmin muuttuviin liiketoimintamalleihin. Lopputuloksena kehitettiin mallijärjestelmä, jolla pystytään täyttämään laitevalmistajan ja loppukäyttäjän muuttuneet informaatiotarpeet osana laiteohjausta.
Resumo:
Differential X-ray phase-contrast tomography (DPCT) refers to a class of promising methods for reconstructing the X-ray refractive index distribution of materials that present weak X-ray absorption contrast. The tomographic projection data in DPCT, from which an estimate of the refractive index distribution is reconstructed, correspond to one-dimensional (1D) derivatives of the two-dimensional (2D) Radon transform of the refractive index distribution. There is an important need for the development of iterative image reconstruction methods for DPCT that can yield useful images from few-view projection data, thereby mitigating the long data-acquisition times and large radiation doses associated with use of analytic reconstruction methods. In this work, we analyze the numerical and statistical properties of two classes of discrete imaging models that form the basis for iterative image reconstruction in DPCT. We also investigate the use of one of the models with a modern image reconstruction algorithm for performing few-view image reconstruction of a tissue specimen.
Resumo:
Breathing-induced bulk motion of the myocardium during data acquisition may cause severe image artifacts in coronary magnetic resonance angiography (MRA). Current motion compensation strategies include breath-holding or free-breathing MR navigator gating and tracking techniques. Navigator-based techniques have been further refined by the applications of sophisticated 2D k-space reordering techniques. A further improvement in image quality and a reduction of relative scanning duration may be expected from a 3D k-space reordering scheme. Therefore, a 3D k-space reordered acquisition scheme including a 3D navigator gated and corrected segmented k-space gradient echo imaging sequence for coronary MRA was implemented. This new zonal motion-adapted acquisition and reordering technique (ZMART) was developed on the basis of a numerical simulation of the Bloch equations. The technique was implemented on a commercial 1.5T MR system, and first phantom and in vivo experiments were performed. Consistent with the results of the theoretical findings, the results obtained in the phantom studies demonstrate a significant reduction of motion artifacts when compared to conventional (non-k-space reordered) gating techniques. Preliminary in vivo findings also compare favorably with the phantom experiments and theoretical considerations. Magn Reson Med 45:645-652, 2001.
Resumo:
L'expérience LHCb sera installée sur le futur accélérateur LHC du CERN. LHCb est un spectromètre à un bras consacré aux mesures de précision de la violation CP et à l'étude des désintégrations rares des particules qui contiennent un quark b. Actuellement LHCb se trouve dans la phase finale de recherche et développement et de conception. La construction a déjà commencé pour l'aimant et les calorimètres. Dans le Modèle Standard, la violation CP est causée par une phase complexe dans la matrice 3x3 CKM (Cabibbo-Kobayashi-Maskawa) de mélange des quarks. L'expérience LHCb compte utiliser les mesons B pour tester l'unitarité de cette matrice, en mesurant de diverses manières indépendantes tous les angles et côtés du "triangle d'unitarité". Cela permettra de surdéterminer le modèle et, peut-être, de mettre en évidence des incohérences qui seraient le signal de l'existence d'une physique au-delà du Modèle Standard. La reconstruction du vertex de désintégration des particules est une condition fondamentale pour l'expérience LHCb. La présence d'un vertex secondaire déplacé est une signature de la désintégration de particules avec un quark b. Cette signature est utilisée dans le trigger topologique du LHCb. Le Vertex Locator (VeLo) doit fournir des mesures précises de coordonnées de passage des traces près de la région d'interaction. Ces points sont ensuite utilisés pour reconstruire les trajectoires des particules et l'identification des vertices secondaires et la mesure des temps de vie des hadrons avec quark b. L'électronique du VeLo est une partie essentielle du système d'acquisition de données et doit se conformer aux spécifications de l'électronique de LHCb. La conception des circuits doit maximiser le rapport signal/bruit pour obtenir la meilleure performance de reconstruction des traces dans le détecteur. L'électronique, conçue en parallèle avec le développement du détecteur de silicium, a parcouru plusieurs phases de "prototyping" décrites dans cette thèse.<br/><br/>The LHCb experiment is being built at the future LHC accelerator at CERN. It is a forward single-arm spectrometer dedicated to precision measurements of CP violation and rare decays in the b quark sector. Presently it is finishing its R&D and final design stage. The construction already started for the magnet and calorimeters. In the Standard Model, CP violation arises via the complex phase of the 3 x 3 CKM (Cabibbo-Kobayashi-Maskawa) quark mixing matrix. The LHCb experiment will test the unitarity of this matrix by measuring in several theoretically unrelated ways all angles and sides of the so-called "unitary triangle". This will allow to over-constrain the model and - hopefully - to exhibit inconsistencies which will be a signal of physics beyond the Standard Model. The Vertex reconstruction is a fundamental requirement for the LHCb experiment. Displaced secondary vertices are a distinctive feature of b-hadron decays. This signature is used in the LHCb topology trigger. The Vertex Locator (VeLo) has to provide precise measurements of track coordinates close to the interaction region. These are used to reconstruct production and decay vertices of beauty-hadrons and to provide accurate measurements of their decay lifetimes. The Vertex Locator electronics is an essential part of the data acquisition system and must conform to the overall LHCb electronics specification. The design of the electronics must maximise the signal to noise ratio in order to achieve the best tracking reconstruction performance in the detector. The electronics is being designed in parallel with the silicon detector development and went trough several prototyping phases, which are described in this thesis.
Resumo:
A beautiful smile is directly related with white teeth. Nowadays oral care has increased and developed processes for beautiful smiles. Dental bleaching is frequently used in odontology, not just for health care also for aesthetic treatment. With the possibility of teeth bleaching, now the importance is in, how white the tooth is? Because color is relate to an individual perception. In order to assets teeth correct color identification has been developed many color guides, models, spaces and analytical methods. Spite all of these useful tools the color interpretation depends on environmental factors, position of the sample in the data acquisition and most importantly the instrument sensitivity. The commons methods have proved to be useful. They are easy to handle, some are portable but they do not have a high sensitivity. The present work is based on the integration of a new analytical technique for color acquisition. High spectral Image (HSI) is able to performed image analysis with high quality and efficiency. HSI is used in many fields and we used it for color image analysis within the bleaching process. The main comparison was done with the HSI and the colorimeter through the processes of two different bleaching protocols. The results showed that HSI has higher sensitivity than the colorimeter. During the analysis the dental surface with the HSI we were able to notice surface changes. These changes were analyzed by roughness studies.
Resumo:
In this study, the evaluation of the accuracy and performance of a light detection and ranging (LIDAR) sensor for vegetation using distance and reflection measurements aiming to detect and discriminate maize plants and weeds from soil surface was done. The study continues a previous work carried out in a maize field in Spain with a LIDAR sensor using exclusively one index, the height profile. The current system uses a combination of the two mentioned indexes. The experiment was carried out in a maize field at growth stage 12–14, at 16 different locations selected to represent the widest possible density of three weeds: Echinochloa crus-galli (L.) P.Beauv., Lamium purpureum L., Galium aparine L.and Veronica persica Poir.. A terrestrial LIDAR sensor was mounted on a tripod pointing to the inter-row area, with its horizontal axis and the field of view pointing vertically downwards to the ground, scanning a vertical plane with the potential presence of vegetation. Immediately after the LIDAR data acquisition (distances and reflection measurements), actual heights of plants were estimated using an appropriate methodology. For that purpose, digital images were taken of each sampled area. Data showed a high correlation between LIDAR measured height and actual plant heights (R2 = 0.75). Binary logistic regression between weed presence/absence and the sensor readings (LIDAR height and reflection values) was used to validate the accuracy of the sensor. This permitted the discrimination of vegetation from the ground with an accuracy of up to 95%. In addition, a Canonical Discrimination Analysis (CDA) was able to discriminate mostly between soil and vegetation and, to a far lesser extent, between crop and weeds. The studied methodology arises as a good system for weed detection, which in combination with other principles, such as vision-based technologies, could improve the efficiency and accuracy of herbicide spraying.
Resumo:
Tässä diplomityössä tutustutaan IGBT:n ja tehodiodin rakenteisiin, lämmön muodostumiseen kyseisissä komponenteissa sekä menetelmiin, joilla komponenttien lämpötilat voidaan määrittää. Työssä suunnitellaan ja rakennetaan mittausjärjestelmä, jolla IGBT:n ja tehodiodin lämpötilat voidaan määrittää suoraan mittaamalla sekä matemaattisten mallien avulla. Mittausjärjestelmä koostuu DC-chopper -kytkennästä, kuormavirran, välipiirin jännitteen sekä lämpötilan mittauksista. Lämpötilan mittauksissa käytettiin komponenttien pintoihin liitettyjä termopareja. Matemaattisia malleja varten mittausjärjestelmään lisättiin välipiirin jännitteen sekä kuormavirran mittaus. Laitteiston ohjaus sekä mittaustulosten tallentaminen toteutettiin dSPACE -laitteistolla. Mittausjärjestelmän toimivuus testattiin Lappeenrannan teknillisen yliopiston Säätötekniikan laboratoriossa tehdyillä mittauksilla.
Resumo:
Tässä diplomityössä esitellään langattoman mittaus- ja valvontajärjestelmän protokollakehitys. Työssä selvitetään protokollakehityksessä huomioon otettavat asiat ja esitetään langattoman tilavalvontaan perustuvan pilottijärjestelmän toteutus. Pilottijärjestelmänä käytetään Ensto Busch-Jaeger Oy:n Jussi-kosteusvahtijärjestelmää, joka muutetaan langattomaksi. Järjestelmän tiedonsiirto on yksisuuntaista ja tapahtuu radioyhteydellä. Käytetty taajuus on 433,92 MHz. Tavoitteena työssä oli kehittää yksinkertainen, mutta luotettava signalointijärjestelmä. Siihen toteutettu protokolla koodaa lähetettävän datan NRZ-L -koodauksen tapaisesti. Virheenkorjaus tehdään pariteettibittiä ja Hamming-etäisyyttä hyväksi käyttäen. Lisäksi tiedonsiirron yhteyskäytäntöön on lisätty rinnakkaisuutta yksisuuntaisen tiedonsiirron varmistamiseksi. Kehitetylle protokollalle tehdyt testit osoittavat sen olevan luotettava valitussa tiedonsiirtoympäristössä.
Resumo:
Työn tarkoituksena oli toteuttaa moottoriajoneuvon suorituskyvyn mittaukseen käytettävä järjestelmä. Järjestelmä koostuu sylinterin muotoisesta rullasta ja tiedonkeruujärjestelmästä. Rullaa, jonka hitausmomentti tunnetaan kiihdytetään ajoneuvon vetopyörien välityksellä ja mitatuista arvoista lasketaan teho ja vääntömomenttiarvot moottorin kierrosluvun funktiona. Tiedonkeruu tapahtuu PC-mikrotietokoneen avulla, johon on liitetty tiedonkeruukortti. PC-mikrotietokone muodostaa käyttöliittymän, jonka avulla saadut tulokset esitetään kuvaajien avulla käyttäjälle. Käyttöliittymän avulla suoritetaan myös tulosten talletus ja raportin tulostus. Teoriaosassa tarkastellaan suorituskyvyn mittaamiseen käytettyjä menetelmiä ja laitteistoja, sekä tiedonkeruujärjestelmän rakennetta ja sen valintaan vaikuttavia tekijöitä. Käytännön osassa suunnitellaan muokkainkortti, jonka avulla erilaisilta antureilta saadut signaalit voidaan sovittaa tiedonkeruukortin tuloalueelle sopiviksi. Myös käyttöliittymän toimintaa ja sen rakentamiseen käytettyjä työkaluja tarkastellaan.