901 resultados para Combined loading of axial compression and torsion


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Statement of problem. A clinically significant incisal pin opening may occur after processing complete dentures if a compression molding technique is used. To recover the proper vertical dimension of occlusion, a time-consuming occlusal adjustment is necessary that often destroys the anatomy of the artificial teeth. A new injection molding process claims to produce dentures that require few, if any, occlusal adjustments in the laboratory after processing.Purpose. This laboratory study compared incisal pin opening, dimensional accuracy, and laboratory working time for dentures fabricated by this new injection system with dentures constructed by the conventional compression molding technique.Material and methods. Two groups of 6 maxillary and 6 mandibular dentures were evaluated as follows: group 1 (control), Lucitone 199, compression molded with a long cure cycle; and group 2, Lucitone 199, injection molded with a long cure. Incisal pin opening was measured with a micrometer immediately after deflasking. A computerized coordinate measuring machine was used to measure dimensional accuracy of 3-dimensional variations in selected positions of artificial teeth in 4 stages of denture fabrication. Analysis of variance (ANOVA) and t tests were performed to compare the groups.Results. A significant difference was found in pin opening between groups (t test). Horizontal dimensional changes evaluated with repeated measures ANOVA revealed no significant differences between groups. However, analysis of vertical dimensional changes disclosed significant differences between the groups. There was no appreciable difference in laboratory working time for flasking and molding denture bases between the injection and compression molding techniques when polymethyl methacrylate resin was used.Conclusion. The injection molding method produced a significantly smaller incisal pin opening over the standard compression molding technique. The injection molding technique, using polymethyl methacrylate, was a more accurate method for processing dentures. There were no appreciable differences in laboratory working time between the injection and compression molding techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The contamination of water by metal compounds is a worldwide environmental problem. Concentrations of metals are widely related to biochemical values which are used in disease diagnosis due to environmental toxicity. The acute combined effects of cadmium and nickel on biochemical parameters were determined and compared with those of Cd2+ or Ni2+ alone in rats. Male adult rats were given drinking solutions of CdCl2 [Cd(II) cation, 100 mg/liter] or NiSO4 [Ni(II) cation, 100 mg/liter]. For the combined treatment, the animals (Ni+Cd) received both Ni(II)) cation (100 mg/liter) and Cd(II) cation (100 mg/liter). Nickel treatment induced increased alanine transaminase (ALT) activity and hepatotoxicity, but not renal injury. In contrast, cadmium exposure produced hepatic, renal and myocardial damage, characterized by increased creatinine, total and direct bilirubin concentrations and increased ALT and lactate dehydrogenase (LDH) activities. The combined effect Ni-Cd is less toxic than cadmium alone, suggesting antagonism between these toxicants. The toxicity of nickel and cadmium, alone and in combination, decreased Cu-Zn superoxide dismutase (SOD) activity and increased lipoperoxide formation. (C) 1998 Elsevier B.V. Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Photoelectrocatalytic degradation of metallophtalocyanine reactive dye (turquoise blue 15) was performed using a Ti/TiO2 thin film photoanode prepared by sol-get method. Hundred percent of color removal and almost complete mineralization (95% at pH 2 and 85% at pH 8) where achieved after 6 h of photolectrocatalytic oxidation of 2.5 x 10(-5) mol L-1 AT15 dye in Na2SO4 mol L-1 under E = +1.2 V versus SCE. The method limitation occurs at dye concentration higher than 4 x 10-5 mol L-1, where the degradation rate becomes markedly slower. An important improvement in color removal and TOC reduction for 1 x 10(-3) mol L-1 metallophtalocyanine dye was achieved using a combined process. After 4 h of potential controlled electrolysis at -1.2 V on a cathode of platinum followed by 6 h of photoelectrocatalytic oxidation leads to 100% of color removal and 83% of TOC decay and eletrodeposition of 69% of the released copper originally presented as copperphtalocyanine complex, by electrodeposition on the cathode without any other treatment. (C) 2005 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several years of total ozone measured from space by the ERS-2 GOME, the Earth Probe TOMS, and the ADEOS TOMS, are compared with high-quality ground-based observations associated with the Network for the Detection of Stratospheric Change (NDSC), over an extended latitude range and a variety of geophysical conditions. The comparisons with each spaceborne sensor are combined altogether for investigating their respective solar zenith angle (SZA) dependence, dispersion, and difference of sensitivity. The space- and ground-based data are found to agree within a few percent on average. However, the analysis highlights for both GOME and TOMS several sources of discrepancies: (i) a SZA dependence with TOMS beyond 80° SZA; (ii) a seasonal SZA dependence with GOME beyond 70° SZA; (iii) a difference of sensitivity with GOME at high latitudes; (iv) a difference of sensitivity to low ozone values between satellite and SAOZ sensors around the southern tropics; (v) a north/south difference of TOMS with the ground-based observations; and (vi) internal inconsistencies in GOME total ozone. © 2001 COSPAR. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It has previously been shown that, while cyclosporin A (CsA) and nifedipine both cause gingival overgrowth in the rat. the combined use of these drugs increases the severity of overgrowth. The aim of this study was to describe the histometry and densities of fibroblasts, collagen fibers and vessels in the gingival tissue of rats that were treated with CsA and nifedipine, either alone or in combination. Rats were treated for 60 days with a daily subcutaneous injection of 10 mg/kg body weight of CsA and/or with 50 mg/kg body weight of nifedipine added to the chow. The results confirmed that CsA causes a more severe overgrowth than nifedipine, and that the combined use of these drugs increases the overgrowth severity. All the rat groups that were studied showed that, as the severity of overgrowth increased, there was a parallel increase in fibroblasts and collagen, and a decrease in vessel content. Therefore, independently of whether the gingival overgrowth was caused by CsA alone, nifedipine alone, or both treatments in combination, the fibroblast and collagen density increased in parallel with the severity of the overgrowth. © Blackwell Munksgaard, 2002.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: There is some evidence showing that cyclosporin A (CsA) and nifedipine (NIF) affect bone metabolism. The purpose of this work was to study the effects of CsA and NIF, given alone or concurrently, on alveolar bone of rats of different ages. Methods: Rats 15, 30, 60, and 90 days old were treated daily with 10 mg/kg body weight of CsA subcutaneously injected and/or 50 mg/kg body weight of NIF/day given orally for 60 days. Alveolar bone of the first lower molars was morphologically and stereologically evaluated in serial 5 μm bucco-lingual paraffin sections, stained with hematoxylin and eosin. Serum calcium and alkaline phosphatase levels were measured in all animals at the end of the experimental period. Results: Rats treated with CsA or NIF alone or CsA and NIF concurrently showed decreased alveolar bone density. CsA was more effective than NIF. A significant decrease in serum calcium was found only in animals treated with CsA or CsA/NIF. The results were similar regardless of age. Conclusions: These results indicate that the decrease in the alveolar bone volume in rats caused by CsA and NIF alone or concurrently is not age dependent. Furthermore, NIF (50 mg/kg) did not further increase the loss of alveolar bone volume induced by CsA (10 mg/kg).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The correct radiographic identification of ossification of the pterygospinous and pterygoalar ligaments plays an important role in surgical procedures for the treatment of trigeminal neuralgia. Most of these procedures are performed through the foramen ovale, a site where these ligaments can be found to be partially or completely ossified. We studied the radiographic features of these ossified ligaments and their location in relation to the foramen ovale by the Hirtz axial technique. For this purpose, 93 dry skulls from the Discipline of Anatomy, São José dos Campos Dental School, UNESP, which presented partial or complete ossification of these ligaments, were radiographed. The pterygospinous ligament was detected on 27.97% of radiographs and was partially ossified in 19.36% of cases and completely ossified in 8.61%. The pterygoalar ligament was present in 62.35% of radiographs, being partially ossified in 49.44% and completely ossified in 12.91%. The pterygospinous ligaments was found to be partially and completely ossified on the same radiograph in 3.23% of cases, whereas the pterygoalar ligament appeared partially and completely ossified on the same radiograph in 6.45%. Furthermore, the pterygospinous ligament was thinner than the pterygoalar ligament and located more medially in relation to the foramen ovale. The pterygoalar ligament formed a large bone bar lateral to the foramen ovale, often obliterating the lumen of the latter. The Hirtz axial technique is an excellent tool for the observation of complete or partial ossification of the pterygospinous and pterygoalar ligaments in surgical procedures for the treatment of trigeminal neuralgia performed through the foramen ovale.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The present study used strain gauge analysis to perform an in vitro evaluation of the effect of axial loading on 3 elements of implant-supported partial fixed prostheses, varying the type of prosthetic cylinder and the loading points. Material and methods: Three internal hexagon implants were linearly embedded in a polyurethane block. Microunit abutments were connected to the implants applying a torque of 20 Ncm, and prefabricated Co-Cr cylinders and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 5). Four strain gauges (SG) were bonded onto the surface of the block tangentially to the implants, SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments with a 10 Ncm torque and an axial load of 30 kg was applied at five predetermined points (A, B, C, D, E). The data obtained from the strain gauge analyses were analyzed statistically by RM ANOVA and Tukey's test, with a level of significance of p<0.05. Results: There was a significant difference for the loading point (p=0.0001), with point B generating the smallest microdeformation (239.49 με) and point D the highest (442.77 με). No significant difference was found for the cylinder type (p=0.748). Conclusions: It was concluded that the type of cylinder did not affect in the magnitude of microdeformation, but the axial loading location influenced this magnitude.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a combined theoretical and experimental study on the electronic structure and photoluminescence (PL) properties of beta zinc molybdate (β-ZnMoO4) microcrystals synthesized by the hydrothermal method has been employed. These crystals were structurally characterized by X-ray diffraction (XRD), Rietveld refinement, Fourier transform Raman (FT-Raman) and Fourier transform infrared (FT-IR) spectroscopies. Their optical properties were investigated by ultraviolet-visible (UV-Vis) absorption spectroscopy and PL measurements. First-principles quantum mechanical calculations based on the density functional theory at the B3LYP level have been carried out. XRD patterns, Rietveld refinement, FT-Raman and FT-IR spectra showed that these crystals have a wolframite-type monoclinic structure. The Raman and IR frequencies experimental results are in reasonable agreement with theoretically calculated results. UV-Vis absorption measurements shows an optical band gap value of 3.17 eV, while the calculated band structure has a value of 3.22 eV. The density of states indicate that the main orbitals involved in the electronic structure of β-ZnMoO4 crystals are (O 2p-valence band and Mo 4d-conduction band). Finally, PL properties of β-ZnMoO4 crystals are explained by means of distortions effects in octahedral [ZnO6] and [MoO6] clusters and inhomogeneous electronic distribution into the lattice with the electron density map. © 2013 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Staphylococcus epidermidis is an organism commonly associated with infections caused by biofilms. Biofilms are less sensible to antibiotics and therefore are more difficult to eradicate. Linezolid and N-acetylcysteine (NAC), have demonstrated to be active against gram-positive microorganisms. Therefore and since linezolid and NAC have different modes of action, the main objective of this work was to investigate the single and synergistic effect of linezolid and NAC against S. epidermidis biofilms. Methods: This work reports the in vitro effect of linezolid and NAC against S. epidermidis biofilms, treated with MIC (4 mg ml-1) and 10×MIC of NAC, and MIC (1 μg ml-1) and peak serum concentration (PS = 18 μg ml-1) of linezolid alone and in combination. After exposure of S. epidermidis biofilms to linezolid and/or NAC for 24 h, several biofilm parameters were evaluated, namely the number of cultivable cells [colony forming unit (CFU) enumeration], total biofilm biomass and cellular activity. Results: When tested alone, NAC at 10×MIC was the most effective agent against S. epidermidis biofilms. However, the combination linezolid (MIC) + NAC (10×MIC) showed a synergistic effect and was the most biocidal treatment tested, promoting a 5 log reduction in the number of biofilm viable cells. Conclusion: This combination seems to be a potential candidate to combat infections caused by S. epidermidis biofilms, namely as a catheter lock solution therapy. © 2012 Elsevier España, S.L. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We study consistently the pion's static observables and the elastic and γ* γ → π0 transition form factors within a light-front model. Consistency requires that all calculations are performed within a given model with the same and single adjusted length or mass-scale parameter of the associated pion bound-state wave function. Our results agree well with all extent data including recent Belle data on the γ* γ → π0 form factor at large q2, yet the BaBar data on this transition form factor resists a sensible comparison. We relax the initial constraint on the bound-state wave function and show the BaBar data can partially be accommodated. This, however, comes at the cost of a hard elastic form factor not in agreement with experiment. Moreover, the pion charge radius is about 40 % smaller than its experimentally determined value. It is argued that a decreasing charge radius produces an ever harder form factor with a bound-state amplitude difficultly reconcilable with soft QCD. We also discuss why vector dominance type models for the photon-quark vertex, based on analyticity and crossing symmetry, are unlikely to reproduce the litigious transition form factor data. © 2013 Springer-Verlag Wien.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

CONTEXTO:A melhor dose para o início do tratamento anticoagulante com varfarina vem sendo debatida nos últimos dez anos. Em nosso meio, não observamos nenhum estudo comparativo quanto a estas características.OBJETIVO:Comparar segurança e eficácia de dois esquemas de dosagem inicial de varfarina para tratamento anticoagulante.MÉTODOS:Foram estudados prospectivamente 110 pacientes de ambos os sexos, consecutivos, com indicação de anticoagulação por tromboembolismo venoso ou arterial. Durante os três primeiros dias de tratamento, estes pacientes receberam doses adequadas de heparina (RT - razão dos tempos - alvo entre 1,5 e 2,5) e 5 mg de varfarina, cuja dose foi reajustada a partir do quarto dia pelo Razão Normatizada Internacional - RNI (alvo entre 2 e 3). Esse grupo foi comparado com série histórica de 110 pacientes que receberam 10 mg nos dois primeiros dias, 5 mg a partir do terceiro dia, com ajuste posterior de dose baseado no RNI. Os desfechos foram: recorrência do tromboembolismo, sangramentos e tempo para alcançar níveis terapêuticos.RESULTADOS:A eficácia, a segurança e o tempo de internação foram similares entre os grupos. O grupo que recebeu 10 mg atingiu níveis terapêuticos mais precocemente (média de 4,5 dias × 5,8 dias), sendo as doses na alta menores e os níveis terapêuticos mais adequados na primeira visita de retorno.CONCLUSÃO:O esquema de dosagem de 10 mg proporcionou menor tempo para alcançar nível terapêutico, com menores doses de varfarina na alta e RNI mais adequado no retorno.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)