963 resultados para Chromatography coupled to mass spectrometry


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A rapid, sensitive and specific method for quantifying hydroxocobalamin in human plasma using paracetamol as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid-liquid extraction using an organic solvent (ethanol 100%; -20°C). The extracts were analyzed by high performance liquid chromatography coupled with electrospray tandem mass spectrometry (HPLC-MS-MS). Chromatography was performed on Prevail C8 3 μm, analytical column (2.1×100 mm i.d.). The method had a chromatographic run time of 3.4 min and a linear calibration curve over the range 5-400 ng.mL-1 (r>0.9983). The limit of quantification was 5 ng.mL-1. The method was also validated without the use of the internal standard. The precision in the intra-batch validation with IS was 9.6%, 8.9%, 1.0% and 2.8% whereas without IS was 9.2%, 8.2%, 1.8% and 1.5% for 5, 15, 80 and 320 ng/mL, respectively. The accuracy in intra-batch validation with IS was 108.9%, 99.9%, 98.9% and 99.0% whereas without IS was 101.1%, 99.3%, 97.5% and 92.5% for 5, 15, 80 and 320 ng/mL, respectively. The precision in the inter-batch validation with IS was 9.4%, 6.9%, 4.6% and 5.5% whereas without IS was 10.9%, 6.4%, 5.0% and 6.2% for 5, 15, 80 and 320 ng/mL, respectively. The accuracy in inter-batch validation with IS was 101.9%, 104.1%, 103.2% and 99.7% whereas without IS was 94.4%, 101.2%, 101.6% and 96.0% for 5, 15, 80 and 320 ng/mL, respectively. This HPLC-MS-MS procedure was used to assess the pharmacokinetics of Hydroxo cobalamin following intramuscular injection 5000 μg in healthy volunteers of both sexes (10 males and 10 females). The volunteers had the following clinical characteristics (according to gender and expressed as mean ± SD [range]): males: age: 32.40 ± 8.00 y [23.00-46.00], height: 1.73 ± 0.07 m [1.62-1.85], body weight: 72.48 ± 10.22 Kg [60.20- 88.00]; females: age: 28.60 ± 9.54 y [18.00-44.00], height: 1.60 ± 0.05 m [1.54-1.70], body weight: 58.64 ± 6.09 Kg [51.70- 66.70]. The following pharmacokinetic parameters were obtained from the hydroxocobalamin plasma concentration vs. time curves: AUClast, T1/2, Tmax, Vd, Cl, Cmax and Clast. The pharmacokinetic parameters were 120 (± 25) ng/mL for Cmax, 2044 (± 641) ng.h/mL for AUClast, 8 (± 3.2) ng.mL-1 for Clast, 38 (± 15.8) hr for T1/2 and 2.5 (range 1-6) hr for Tmax. Female volunteers presented significant (p=0.0136) lower AUC (1706 ± 704) ng.h/mL) and larger (p=0.0205) clearance (2.91 ± 1.41 L/hr), as compared to male 2383 ± 343 ng.h/mL and 1.76 ± 0.23 L/hr, respectively. These pharmacokinetic differences could explain the higher prevalence of vitamin B12 deficiency in female patients. The method described validated well without the use of the internal standard and this approach should be investigated in other HPLC-MS-MS methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Plantaginis Semen is commonly used in traditional medicine to treat edema, hypertension, and diabetes. The commercially available Plantaginis Semen in China mainly comes from three species. To clarify the chemical composition and distinct different species of Plantaginis Semen, we established a metabolite profiling method based on ultra high performance liquid chromatography with electrospray ionization quadrupole time-of-flight tandem mass spectrometry coupled with elevated energy technique. A total of 108 compounds, including phenylethanoid glycosides, flavonoids, guanidine derivatives, terpenoids, organic acids, and fatty acids, were identified from Plantago asiatica L., P. depressa Willd., and P. major L. Results showed significant differences in chemical components among the three species, particularly flavonoids. This study is the first to provide a comprehensive chemical profile of Plantaginis Semen, which could be involved into the quality control, medication guide, and developing new drug of Plantago seeds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Negative-ion mode electrospray ionization, ESI(-), with Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) was coupled to a Partial Least Squares (PLS) regression and variable selection methods to estimate the total acid number (TAN) of Brazilian crude oil samples. Generally, ESI(-)-FT-ICR mass spectra present a power of resolution of ca. 500,000 and a mass accuracy less than 1 ppm, producing a data matrix containing over 5700 variables per sample. These variables correspond to heteroatom-containing species detected as deprotonated molecules, [M - H](-) ions, which are identified primarily as naphthenic acids, phenols and carbazole analog species. The TAN values for all samples ranged from 0.06 to 3.61 mg of KOH g(-1). To facilitate the spectral interpretation, three methods of variable selection were studied: variable importance in the projection (VIP), interval partial least squares (iPLS) and elimination of uninformative variables (UVE). The UVE method seems to be more appropriate for selecting important variables, reducing the dimension of the variables to 183 and producing a root mean square error of prediction of 0.32 mg of KOH g(-1). By reducing the size of the data, it was possible to relate the selected variables with their corresponding molecular formulas, thus identifying the main chemical species responsible for the TAN values.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tramadol (T) is available as a racemic mixture of (+)-trans-T and (-)-trans-T. The main metabolic pathways are O-demethylation and N-demethylation, producing trans-O-desmethyltramadol (M1) and trans-N-desmethyltramadol (M2) enantiomers, respectively. The analgesic effect of T is related to the opioid activity of (+)-trans-T and (+)-M1 and to the monoaminergic action of (+/-)-trans-T. This is the first study using tandem mass spectrometry as a detection system for the simultaneous analysis of trans-T, M1, and M2 enantiomers. The analytes were resolved on a Chiralpak (R) AD column using hexane: ethanol (95.5:4.5, v/v) plus 0.1% diethylamine as the mobile phase. The quantitation limits were 0.5 ng/ml for trans-T and M1 and 0.1 ng/ml for M2. The method developed and validated here was applied to a pharmacokinetic study in rats. Male Wistar rats (n = 6 at each time point) received a single oral dose of 20 mg/kg racemic trans-T. Blood samples were collected up to 12 h after drug administration. The kinetic disposition of trans-T and M2 was enantioselective (AUC((+)/(-)) ratio = 4.16 and 6.36, respectively). The direction and extent of enantioselectivity in the pharmacokinetics of trans-T and M2 in rats were comparable to data previously reported for healthy volunteers, suggesting that rats are a suitable model for enantioselective studies of trans-T pharmacokinetics. Chirality 23: 287-293, 2011. (C) 2010 Wiley-Liss, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mexiletine (MEX), hydroxymethylmexiletine (HMM) and P-hydroxy-mexiletine (PHM) were analyzed in rat plasma by LC-MS/MS. The plasma samples were prepared by liquid-liquid extraction using methyl-tert-butyl ether as extracting solvent. MEX, HMM, and PHM enantiomers were resolved on a Chiralpak (R) AD column. Validation of the method showed a relative standard deviation (precision) and relative errors (accuracy) of less than 15% for all analytes studied. Quantification limits were 0.5 ng ml(-1) for the MEX and 0.2 ng ml(-1) for the HMM and PHM enantiomers. The validated method was successfully applied to quantify the enantiomers of MEX and its metabolites in plasma samples of rats (n = 6) treated with a single oral dose of racemic MEX. Chirality 21:648-656, 2009. (C) 2008 Wiley-Liss, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have utilised the combination of sensitivity and specificity afforded by coupling high-performance liquid chromatography (HPLC) to a tandem mass spectrometer (MS-MS) to produce an assay which is suitable for assaying glutathione (GSH) concentrations in liver tissue. The sensitivity suggests it may also be suitable for extrahepatic tissues, The method has been validated for GSH using mouse liver samples and also allows the assay of GSSG. The stability of GSH under conditions relevant to the assay has been determined. A 20-mul amount of a diluted methanol extract of tissue is injected with detection limits of 0.2 pmol for GSH and 2 pmol for GSSG. The HPLC uses an Altima C-18 (150X4.6 mm, 5 mum) column at 35 degreesC. Chromatography utilises a linear gradient from 0 to 10% methanol in 0.1% formic acid over 5 min, with a final isocratic stage holding at 10% methanol for 5 min. Total flow rate is 0.8 ml/min. The transition from the M+H ion (308.1 m/z for GSH, and 613.3 m/z for GSSG) to the 162.0 m/z (GSH) and 355.3 m/z (GSSG) fragments are monitored. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação apresentada para obtenção do Grau de Doutor em Ciências do Ambiente pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecn

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The response of Arabidopsis to stress caused by mechanical wounding was chosen as a model to compare the performances of high resolution quadrupole-time-of-flight (Q-TOF) and single stage Orbitrap (Exactive Plus) mass spectrometers in untargeted metabolomics. Both instruments were coupled to ultra-high pressure liquid chromatography (UHPLC) systems set under identical conditions. The experiment was divided in two steps: the first analyses involved sixteen unwounded plants, half of which were spiked with pure standards that are not present in Arabidopsis. The second analyses compared the metabolomes of mechanically wounded plants to unwounded plants. Data from both systems were extracted using the same feature detection software and submitted to unsupervised and supervised multivariate analysis methods. Both mass spectrometers were compared in terms of number and identity of detected features, capacity to discriminate between samples, repeatability and sensitivity. Although analytical variability was lower for the UHPLC-Q-TOF, generally the results for the two detectors were quite similar, both of them proving to be highly efficient at detecting even subtle differences between plant groups. Overall, sensitivity was found to be comparable, although the Exactive Plus Orbitrap provided slightly lower detection limits for specific compounds. Finally, to evaluate the potential of the two mass spectrometers for the identification of unknown markers, mass and spectral accuracies were calculated on selected identified compounds. While both instruments showed excellent mass accuracy (<2.5ppm for all measured compounds), better spectral accuracy was recorded on the Q-TOF. Taken together, our results demonstrate that comparable performances can be obtained at acquisition frequencies compatible with UHPLC on Q-TOF and Exactive Plus MS, which may thus be equivalently used for plant metabolomics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Since GHB (gamma-hydroxybutyric acid) is naturally produced in the human body, clinical and forensic toxicologists must be able to discriminate between endogenous levels and a concentration resulting from exposure. To suggest an alternative to the use of interpretative concentration cut-offs, the detection of exogenous GHB in urine specimens was investigated by means of gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). GHB was isolated from urinary matrix by successive purification on Oasis MCX and Bond Elute SAX solid-phase extraction (SPE) cartridges prior to high-performance liquid chromatography (HPLC) fractioning using an Atlantis dC18 column eluted with a mixture of formic acid and methanol. Subsequent intramolecular esterification of GHB leading to the formation of gamma-butyrolactone (GBL) was carried out to avoid introduction of additional carbon atoms for carbon isotopic ratio analysis. A precision of 0.3 per thousand was determined using this IRMS method for samples at GHB concentrations of 10 mg/L. The (13)C/(12)C ratios of GHB in samples of subjects exposed to the drug ranged from -32.1 to -42.1 per thousand, whereas the results obtained for samples containing GHB of endogenous origin at concentration levels less than 10 mg/L were in the range -23.5 to -27.0 per thousand. Therefore, these preliminary results show that a possible discrimination between endogenous and exogenous GHB can be made using carbon isotopic ratio analyses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chromatographic separation of highly polar basic drugs with ideal ionspray mass spectrometry volatile mobile phases is a difficult challenge. A new quantification procedure was developed using hydrophilic interaction chromatography-mass spectrometry with turbo-ionspray ionization in the positive mode. After addition of deuterated internal standards and simple clean-up liquid extraction, the dried extracts were reconstituted in 500 microL pure acetonitrile and 5 microL was directly injected onto a Waters Atlantis HILIC 150- x 2.1-mm, 3-microm column. Chromatographic separations of cocaine, seven metabolites, and anhydroecgonine were obtained by linear gradient-elution with decreasing high concentrations of acetonitrile (80-56% in 18 min). This high proportion of organic solvent makes it easier to be coupled with MS. The eluent was buffered with 2 mM ammonium acetate at pH 4.5. Except for m-hydroxy-benzoylecgonine, the within-day and between-day precisions at 20, 100, and 500 ng/mL were below 7 and 19.1%, respectively. Accuracy was also below +/- 13.5% at all tested concentrations. The limit of quantification was 5 ng/mL (%Diff < 16.1, %RSD < 4.3) and the limit of detection below 0.5 ng/mL. This method was successfully applied to a fatal overdose. In Switzerland, cocaine abuse has dramatically increased in the last few years. A 45-year-old man, a known HIV-positive drug user, was found dead at home. According to relatives, cocaine was self-injected about 10 times during the evening before death. A low amount of cocaine (0.45 mg) was detected in the bloody fluid taken from a syringe discovered near the corpse. Besides injection marks, no significant lesions were detected during the forensic autopsy. Toxicological investigations showed high cocaine concentrations in all body fluids and tissues. The peripheral blood concentrations of cocaine, benzoylecgonine, and methylecgonine were 5.0, 10.4, and 4.1 mg/L, respectively. The brain concentrations of cocaine, benzoylecgonine, and methylecgonine were 21.2, 3.8, and 3.3 mg/kg, respectively. The highest concentrations of norcocaine (about 1 mg/L) were measured in bile and urine. Very high levels of cocaine were determined in hair (160 ng/mg), indicating chronic cocaine use. A low concentration of anhydroecgonine methylester was also found in urine (0.65 mg/L) suggesting recent cocaine inhalation. Therapeutic blood concentrations of fluoxetine (0.15 mg/L) and buprenorphine (0.1 microg/L) were also discovered. A relatively high concentration of Delta(9)-THC was measured both in peripheral blood (8.2 microg/L) and brain cortex (13.5 microg/kg), suggesting that the victim was under the influence of cannabis at the time of death. In addition, fluoxetine might have enhanced the toxic effects of cocaine because of its weak pro-arrhythmogenic properties. Likewise, combination of cannabinoids and cocaine might have increase detrimental cardiovascular effects. Altogether, these results indicate a lethal cocaine overdose with a minor contribution of fluoxetine and cannabinoids.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The recommended treatment for latent tuberculosis (TB) infection in adults is a daily dose of isoniazid (INH) 300 mg for six months. In Brazil, INH was formulated as 100 mg tablets. The treatment duration and the high pill burden compromised patient adherence to the treatment. The Brazilian National Programme for Tuberculosis requested a new 300 mg INH formulation. The aim of our study was to compare the bioavailability of the new INH 300 mg formulation and three 100 mg tablets of the reference formulation. We conducted a randomised, single dose, open label, two-phase crossover bioequivalence study in 28 healthy human volunteers. The 90% confidence interval for the INH maximum concentration of drug observed in plasma and area under the plasma concentration vs. time curve from time zero to the last measurable concentration “time t” was 89.61-115.92 and 94.82-119.44, respectively. The main limitation of our study was that neither adherence nor the safety profile of multiple doses was evaluated. To determine the level of INH in human plasma, we developed and validated a sensitive, simple and rapid high-performance liquid chromatography-tandem mass spectrometry method. Our results showed that the new formulation was bioequivalent to the 100 mg reference product. This finding supports the use of a single 300 mg tablet daily strategy to treat latent TB. This new formulation may increase patients’ adherence to the treatment and quality of life.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Saffaj et al. recently criticized our method of monitoring carbon dioxide in human postmortem cardiac gas samples using Headspace-Gas Chromatography-Mass Spectrometry. According to the authors, their demonstration, based on the latest SFSTP guidelines (established after 2007 [1,2]) fitted for the validation of drug monitoring bioanalytical methods, has put in evidence potential errors. However, our validation approach was built using SFSTP guidelines established before 2007 [3-6]. We justify the use of these guidelines because of the post-mortem context of the study (and not clinical) and the gaseous state of the sample (and not solid or liquid). Using these guidelines, our validation remains correct.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of our study was to present a new headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable to the routine determination of hydrogen sulfide (H(2)S) concentrations in biological and gaseous samples. The primary analytical drawback of the GC/MS methods for H(2)S measurement discussed in the literature was the absence of a specific H(2)S internal standard required to perform quantification. Although a deuterated hydrogen sulfide (D(2)S) standard is currently available, this standard is not often used because this standard is expensive and is only available in the gas phase. As an alternative approach, D(2)S can be generated in situ by reacting deuterated chloride with sodium sulfide; however, this technique can lead to low recovery yield and potential isotopic fractionation. Therefore, N(2)O was chosen for use as an internal standard. This method allows precise measurements of H(2)S concentrations in biological and gaseous samples. Therefore, a full validation using accuracy profile based on the β-expectation tolerance interval is presented. Finally, this method was applied to quantify H(2)S in an actual case of H(2)S fatal intoxication.