983 resultados para Calibration plot


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An Adaptive Optic (AO) system is a fundamental requirement of 8m-class telescopes. We know that in order to obtain the maximum possible resolution allowed by these telescopes we need to correct the atmospheric turbulence. Thanks to adaptive optic systems we are able to use all the effective potential of these instruments, drawing all the information from the universe sources as best as possible. In an AO system there are two main components: the wavefront sensor (WFS) that is able to measure the aberrations on the incoming wavefront in the telescope, and the deformable mirror (DM) that is able to assume a shape opposite to the one measured by the sensor. The two subsystem are connected by the reconstructor (REC). In order to do this, the REC requires a “common language" between these two main AO components. It means that it needs a mapping between the sensor-space and the mirror-space, called an interaction matrix (IM). Therefore, in order to operate correctly, an AO system has a main requirement: the measure of an IM in order to obtain a calibration of the whole AO system. The IM measurement is a 'mile stone' for an AO system and must be done regardless of the telescope size or class. Usually, this calibration step is done adding to the telescope system an auxiliary artificial source of light (i.e a fiber) that illuminates both the deformable mirror and the sensor, permitting the calibration of the AO system. For large telescope (more than 8m, like Extremely Large Telescopes, ELTs) the fiber based IM measurement requires challenging optical setups that in some cases are also impractical to build. In these cases, new techniques to measure the IM are needed. In this PhD work we want to check the possibility of a different method of calibration that can be applied directly on sky, at the telescope, without any auxiliary source. Such a technique can be used to calibrate AO system on a telescope of any size. We want to test the new calibration technique, called “sinusoidal modulation technique”, on the Large Binocular Telescope (LBT) AO system, which is already a complete AO system with the two main components: a secondary deformable mirror with by 672 actuators, and a pyramid wavefront sensor. My first phase of PhD work was helping to implement the WFS board (containing the pyramid sensor and all the auxiliary optical components) working both optical alignments and tests of some optical components. Thanks to the “solar tower” facility of the Astrophysical Observatory of Arcetri (Firenze), we have been able to reproduce an environment very similar to the telescope one, testing the main LBT AO components: the pyramid sensor and the secondary deformable mirror. Thanks to this the second phase of my PhD thesis: the measure of IM applying the sinusoidal modulation technique. At first we have measured the IM using a fiber auxiliary source to calibrate the system, without any kind of disturbance injected. After that, we have tried to use this calibration technique in order to measure the IM directly “on sky”, so adding an atmospheric disturbance to the AO system. The results obtained in this PhD work measuring the IM directly in the Arcetri solar tower system are crucial for the future development: the possibility of the acquisition of IM directly on sky means that we are able to calibrate an AO system also for extremely large telescope class where classic IM measurements technique are problematic and, sometimes, impossible. Finally we have not to forget the reason why we need this: the main aim is to observe the universe. Thanks to these new big class of telescopes and only using their full capabilities, we will be able to increase our knowledge of the universe objects observed, because we will be able to resolve more detailed characteristics, discovering, analyzing and understanding the behavior of the universe components.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ground-based Earth troposphere calibration systems play an important role in planetary exploration, especially to carry out radio science experiments aimed at the estimation of planetary gravity fields. In these experiments, the main observable is the spacecraft (S/C) range rate, measured from the Doppler shift of an electromagnetic wave transmitted from ground, received by the spacecraft and coherently retransmitted back to ground. If the solar corona and interplanetary plasma noise is already removed from Doppler data, the Earth troposphere remains one of the main error sources in tracking observables. Current Earth media calibration systems at NASA’s Deep Space Network (DSN) stations are based upon a combination of weather data and multidirectional, dual frequency GPS measurements acquired at each station complex. In order to support Cassini’s cruise radio science experiments, a new generation of media calibration systems were developed, driven by the need to achieve the goal of an end-to-end Allan deviation of the radio link in the order of 3×〖10〗^(-15) at 1000 s integration time. The future ESA’s Bepi Colombo mission to Mercury carries scientific instrumentation for radio science experiments (a Ka-band transponder and a three-axis accelerometer) which, in combination with the S/C telecommunication system (a X/X/Ka transponder) will provide the most advanced tracking system ever flown on an interplanetary probe. Current error budget for MORE (Mercury Orbiter Radioscience Experiment) allows the residual uncalibrated troposphere to contribute with a value of 8×〖10〗^(-15) to the two-way Allan deviation at 1000 s integration time. The current standard ESA/ESTRACK calibration system is based on a combination of surface meteorological measurements and mathematical algorithms, capable to reconstruct the Earth troposphere path delay, leaving an uncalibrated component of about 1-2% of the total delay. In order to satisfy the stringent MORE requirements, the short time-scale variations of the Earth troposphere water vapor content must be calibrated at ESA deep space antennas (DSA) with more precise and stable instruments (microwave radiometers). In parallel to this high performance instruments, ESA ground stations should be upgraded to media calibration systems at least capable to calibrate both troposphere path delay components (dry and wet) at sub-centimetre level, in order to reduce S/C navigation uncertainties. The natural choice is to provide a continuous troposphere calibration by processing GNSS data acquired at each complex by dual frequency receivers already installed for station location purposes. The work presented here outlines the troposphere calibration technique to support both Deep Space probe navigation and radio science experiments. After an introduction to deep space tracking techniques, observables and error sources, in Chapter 2 the troposphere path delay is widely investigated, reporting the estimation techniques and the state of the art of the ESA and NASA troposphere calibrations. Chapter 3 deals with an analysis of the status and the performances of the NASA Advanced Media Calibration (AMC) system referred to the Cassini data analysis. Chapter 4 describes the current release of a developed GNSS software (S/W) to estimate the troposphere calibration to be used for ESA S/C navigation purposes. During the development phase of the S/W a test campaign has been undertaken in order to evaluate the S/W performances. A description of the campaign and the main results are reported in Chapter 5. Chapter 6 presents a preliminary analysis of microwave radiometers to be used to support radio science experiments. The analysis has been carried out considering radiometric measurements of the ESA/ESTEC instruments installed in Cabauw (NL) and compared with the requirements of MORE. Finally, Chapter 7 summarizes the results obtained and defines some key technical aspects to be evaluated and taken into account for the development phase of future instrumentation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Gaia space mission is a major project for the European astronomical community. As challenging as it is, the processing and analysis of the huge data-flow incoming from Gaia is the subject of thorough study and preparatory work by the DPAC (Data Processing and Analysis Consortium), in charge of all aspects of the Gaia data reduction. This PhD Thesis was carried out in the framework of the DPAC, within the team based in Bologna. The task of the Bologna team is to define the calibration model and to build a grid of spectro-photometric standard stars (SPSS) suitable for the absolute flux calibration of the Gaia G-band photometry and the BP/RP spectrophotometry. Such a flux calibration can be performed by repeatedly observing each SPSS during the life-time of the Gaia mission and by comparing the observed Gaia spectra to the spectra obtained by our ground-based observations. Due to both the different observing sites involved and the huge amount of frames expected (≃100000), it is essential to maintain the maximum homogeneity in data quality, acquisition and treatment, and a particular care has to be used to test the capabilities of each telescope/instrument combination (through the “instrument familiarization plan”), to devise methods to keep under control, and eventually to correct for, the typical instrumental effects that can affect the high precision required for the Gaia SPSS grid (a few % with respect to Vega). I contributed to the ground-based survey of Gaia SPSS in many respects: with the observations, the instrument familiarization plan, the data reduction and analysis activities (both photometry and spectroscopy), and to the maintenance of the data archives. However, the field I was personally responsible for was photometry and in particular relative photometry for the production of short-term light curves. In this context I defined and tested a semi-automated pipeline which allows for the pre-reduction of imaging SPSS data and the production of aperture photometry catalogues ready to be used for further analysis. A series of semi-automated quality control criteria are included in the pipeline at various levels, from pre-reduction, to aperture photometry, to light curves production and analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The thesis describes the implementation of a calibration, format-translation and data conditioning software for radiometric tracking data of deep-space spacecraft. All of the available propagation-media noise rejection techniques available as features in the code are covered in their mathematical formulations, performance and software implementations. Some techniques are retrieved from literature and current state of the art, while other algorithms have been conceived ex novo. All of the three typical deep-space refractive environments (solar plasma, ionosphere, troposphere) are dealt with by employing specific subroutines. Specific attention has been reserved to the GNSS-based tropospheric path delay calibration subroutine, since it is the most bulky module of the software suite, in terms of both the sheer number of lines of code, and development time. The software is currently in its final stage of development and once completed will serve as a pre-processing stage for orbit determination codes. Calibration of transmission-media noise sources in radiometric observables proved to be an essential operation to be performed of radiometric data in order to meet the more and more demanding error budget requirements of modern deep-space missions. A completely autonomous and all-around propagation-media calibration software is a novelty in orbit determination, although standalone codes are currently employed by ESA and NASA. The described S/W is planned to be compatible with the current standards for tropospheric noise calibration used by both these agencies like the AMC, TSAC and ESA IFMS weather data, and it natively works with the Tracking Data Message file format (TDM) adopted by CCSDS as standard aimed to promote and simplify inter-agency collaboration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spatial prediction of hourly rainfall via radar calibration is addressed. The change of support problem (COSP), arising when the spatial supports of different data sources do not coincide, is faced in a non-Gaussian setting; in fact, hourly rainfall in Emilia-Romagna region, in Italy, is characterized by abundance of zero values and right-skeweness of the distribution of positive amounts. Rain gauge direct measurements on sparsely distributed locations and hourly cumulated radar grids are provided by the ARPA-SIMC Emilia-Romagna. We propose a three-stage Bayesian hierarchical model for radar calibration, exploiting rain gauges as reference measure. Rain probability and amounts are modeled via linear relationships with radar in the log scale; spatial correlated Gaussian effects capture the residual information. We employ a probit link for rainfall probability and Gamma distribution for rainfall positive amounts; the two steps are joined via a two-part semicontinuous model. Three model specifications differently addressing COSP are presented; in particular, a stochastic weighting of all radar pixels, driven by a latent Gaussian process defined on the grid, is employed. Estimation is performed via MCMC procedures implemented in C, linked to R software. Communication and evaluation of probabilistic, point and interval predictions is investigated. A non-randomized PIT histogram is proposed for correctly assessing calibration and coverage of two-part semicontinuous models. Predictions obtained with the different model specifications are evaluated via graphical tools (Reliability Plot, Sharpness Histogram, PIT Histogram, Brier Score Plot and Quantile Decomposition Plot), proper scoring rules (Brier Score, Continuous Rank Probability Score) and consistent scoring functions (Root Mean Square Error and Mean Absolute Error addressing the predictive mean and median, respectively). Calibration is reached and the inclusion of neighbouring information slightly improves predictions. All specifications outperform a benchmark model with incorrelated effects, confirming the relevance of spatial correlation for modeling rainfall probability and accumulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

I tetti verdi rappresentano, sempre più frequentemente, una tecnologia idonea alla mitigazione alle problematiche connesse all’ urbanizzazione, tuttavia la conoscenza delle prestazioni dei GR estensivi in clima sub-Mediterraneo è ancora limitata. La presente ricerca è supportata da 15 mesi di analisi sperimentali su due GR situati presso la Scuola di Ingegneria di Bologna. Inizialmente vengono comparate, tra loro e rispetto a una superficie di riferimento (RR), le prestazioni idrologiche ed energetiche dei due GR, caratterizzati da vegetazione a Sedum (SR) e a erbe native perenni (NR). Entrambi riducono i volumi defluiti e le temperature superficiali. Il NR si dimostra migliore del SR sia in campo idrologico che termico, la fisiologia della vegetazione del NR determina l'apertura diurna degli stomi e conseguentemente una maggiore evapotraspirazione (ET). Successivamente si sono studiate la variazioni giornaliere di umidità nel substrato del SR riscontrando che la loro ampiezza è influenzata dalla temperatura, dall’umidità iniziale e dalla fase vegetativa. Queste sono state simulate mediante un modello idrologico basato sull'equazione di bilancio idrico e su due modelli convenzionali per la stima della ET potenziale combinati con una funzione di estrazione dell’ umidità dal suolo. Sono stati proposti dei coefficienti di correzione, ottenuti per calibrazione, per considerare le differenze tra la coltura di riferimento e le colture nei GR durante le fasi di crescita. Infine, con l’ausilio di un modello implementato in SWMM 5.1. 007 utilizzando il modulo Low Impact Development (LID) durante simulazioni in continuo (12 mesi) si sono valutate le prestazioni in termini di ritenzione dei plot SR e RR. Il modello, calibrato e validato, mostra di essere in grado di riprodurre in modo soddisfacente i volumi defluiti dai due plot. Il modello, a seguito di una dettagliata calibrazione, potrebbe supportare Ingegneri e Amministrazioni nella valutazioni dei vantaggi derivanti dall'utilizzo dei GR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The accretionary shells of bivalve mollusks can provide environmental information, such as water temperature, precipitation, freshwater fluxes, primary productivity and anthropogenic activities in the form of variable growth rates and variable geochemical properties, such as stable oxygen and carbon isotopes. However, paleoenvironmental reconstructions are constrained by uncertainties about isotopic equilibrium fractionation during shell formation, which is generally acknowledged as a reasonable assumption for bivalves, but it has been disputed in several species. Furthermore, the variation in shell growth rates is accepted to rely on multiple environmental variables, such as temperature, food availability and salinity, but can differ from species to species. Therefore, it is necessary to perform species-specific calibration studies for both isotope proxies and shell growth rates before they can be used with confidence for environmental interpretations of the past. Accordingly, the principal objective of this Ph.D research is to examine the reliability of selected bivalve species, the long-lived Eurhomalea exalbida (Dillwyn), the short-lived and fast growing species Paphia undulata (Born 1778), and the freshwater mussel Margaritifera falcata (Gould 1850), as paleoenvironmental proxy archives.rnThe first part is focused on δ18Oshell and shell growth history of live-collected E. exalbida from the Falkland Islands. The most remarkable finding, however, is that E. exalbida formed its shell with an offset of -0.48‰ to -1.91‰ from the expected oxygen isotopic equilibrium with the ambient water. If this remained unnoticed, paleotemperature estimates would overestimate actual water temperatures by 2.1-8.3°C. With increasing ontogenetic age, the discrepancy between measured and reconstructed temperatures increased exponentially, irrespective of the seasonally varying shell growth rates. This study clearly demonstrates that, when the disequilibrium fractionation effect is taken into account, E. exalbida can serve as a high-resolution paleoclimate archive for the southern South America. The species therefore provides quantifiable temperature estimates, which yields new insights into long-term paleoclimate dynamics for mid to high latitudes on the southern hemisphere.rnThe stable carbon isotope of biogenic carbonates is generally considered to be useful for reconstruction of seawater dissolved inorganic carbon. The δ13Cshell composition of E. exalbida was therefore, investigated in the second part of this study. This chapter focuses on inter-annual and intra-annual variations in δ13Cshell. Environmental records in δ13Cshell are found to be strongly obscured by changes in shell growth rates, even if removing the ontogenetic decreasing trend. This suggests that δ13Cshell in E. exalbida may not be useful as an environmental proxy, but a potential tool for ecological investigations. rnIn addition to long-lived bivalve species, short-lived species that secrete their shells extremely fast, can also be useful for environmental reconstructions, especially as a high-resolution recorder. Therefore, P. undulata from Daya Bay, South China Sea was utilized in Chapter 4 to evaluate and establish a potential proxy archive for past variations of the East Asian monsoon on shorter time-scales. The δ18Oshell can provide qualitative estimates of the amount of monsoonal rain and terrestrial runoff and the δ13Cshell likely reflect the relative amount of isotopically light terrestrial carbon that reaches the ocean during the summer monsoon season. Therefore, shells of P. undulata can provide serviceable proxy archives to reconstruct the frequency of exceptional summer monsoons in the past. The relative strength of monsoon-related precipitation and associated changes in ocean salinity and the δ13C ratios of the dissolved inorganic carbon signature (δ13CDIC) can be estimated from the δ18Oshell and δ13Cshell values as well as shell growth patterns. rnIn the final part, the freshwater pearl shell M. falcata from four rivers in British Columbia, Canada was preliminarily studied concerning the lifespans and the shell growth rates. Two groups separated by the Georgia Strait can be clearly distinguished. Specimens from the western group exhibit a shorter lifespan, while the eastern group live longer. Moreover, the average lifespan seems to decrease from south to north. The computed growth equations from the eastern and western groups differ as well. The western group exhibits a lower growth rate, while bivalves from the eastern group grow faster. The land use history seems to be responsible for the differences in lifespans of the specimens from the two groups. Differences in growth rate may be induced by differences in water temperature or nutrient input also related to the land use activities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gli aerosol, sospensione colloidale in aria di particelle solide o liquide, sono parte integrante dell’atmosfera. Essi interagiscono con la radiazione solare influenzando il clima (effetto primario e secondario) e la visibilità atmosferica. Gli aerosol hanno effetti sulla salute umana con patologie degli apparati cardiovascolare e circolatorio. La presente tesi affronta alcuni aspetti critici dei contatori ottici di particelle (OPC), utilizzati per caratterizzare l’aerosol ambientale. Gli OPC si basano sullo scattering luminoso per fornire la concentrazione in numero e la distribuzione dimensionale degli aerosol in tempo reale. Gli obiettivi di questa tesi sono: 1)caratterizzare e migliorare le prestazioni di un OPC di nuova concezione (CompactOPC N1, Alphasense; in seguito COPC) rispetto a un OPC standard commerciale (Grimm 1.108; in seguito GRM); 2)realizzare un banco di prova per la calibrazione di un OPC utilizzato in camere bianche e ambienti sanitari (Laser Particle Sensor 3715-00, Kanomax; in seguito LPS). Per questa attività ha mostrato interesse un’azienda locale (Pollution Clean Air Systems S.p.A.; Budrio, BO). Le prove sperimentali sono state effettuate con aerosol indoor e con particelle monodisperse di latex polistirene (PSL) di dimensioni differenti campionando in parallelo con i diversi OPC e su filtro per osservazioni al microscopio elettronico a scansione (SEM). In questo modo si è ottenuto un valore assoluto di riferimento per la concentrazione di aerosol. I risultati ottenuti indicano un buon accordo tra le concentrazioni di particelle fornite dal GRM e quelle ottenute al SEM. Il lavoro ha inoltre permesso di migliorare le prestazioni del COPC modificando la versione di base. Inoltre, è stata effettuata la calibrazione del LPS tramite il banco di prova realizzato nella tesi. Il lavoro sperimentale è stato svolto presso il Laboratorio di Aerosol e Fisica delle Nubi dell’Istituto di Scienze dell’Atmosfera e del Clima (ISAC) del Consiglio Nazionale delle Ricerche (CNR) a Bologna.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La tesi indaga il problema di calibrazione Hand Eye, ovvero la trasformazione geometrica fra i diversi sistemi di riferimento della camera e dell'attuatore del robot, presentando il problema ed analizzando le varie soluzioni proposte in letteratura. Viene infine presentata una implementazione realizzata in collaborazione con l'azienda SpecialVideo, implementata utilizzando l'algoritmo proposto da Konstantinos Daniilidis, il quale propone una formulazione del problema sfruttando l'utilizzo di quaternioni duali, risolvendo simultaneamente la parte rotatoria e traslatoria della trasformazione. Si conclude il lavoro con una analisi dell'efficacia del metodo implementato su dati simulati e proponendo eventuali estensioni, allo scopo di poter riutilizzare in futuro il lavoro svolto nel software aziendale, con dati reali e con diversi tipi di telecamere, principalmente camere lineari o laser.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arterial pressure-based cardiac output monitors (APCOs) are increasingly used as alternatives to thermodilution. Validation of these evolving technologies in high-risk surgery is still ongoing. In liver transplantation, FloTrac-Vigileo (Edwards Lifesciences) has limited correlation with thermodilution, whereas LiDCO Plus (LiDCO Ltd.) has not been tested intraoperatively. Our goal was to directly compare the 2 proprietary APCO algorithms as alternatives to pulmonary artery catheter thermodilution in orthotopic liver transplantation (OLT). The cardiac index (CI) was measured simultaneously in 20 OLT patients at prospectively defined surgical landmarks with the LiDCO Plus monitor (CI(L)) and the FloTrac-Vigileo monitor (CI(V)). LiDCO Plus was calibrated according to the manufacturer's instructions. FloTrac-Vigileo did not require calibration. The reference CI was derived from pulmonary artery catheter intermittent thermodilution (CI(TD)). CI(V)-CI(TD) bias ranged from -1.38 (95% confidence interval = -2.02 to -0.75 L/minute/m(2), P = 0.02) to -2.51 L/minute/m(2) (95% confidence interval = -3.36 to -1.65 L/minute/m(2), P < 0.001), and CI(L)-CI(TD) bias ranged from -0.65 (95% confidence interval = -1.29 to -0.01 L/minute/m(2), P = 0.047) to -1.48 L/minute/m(2) (95% confidence interval = -2.37 to -0.60 L/minute/m(2), P < 0.01). For both APCOs, bias to CI(TD) was correlated with the systemic vascular resistance index, with a stronger dependence for FloTrac-Vigileo. The capability of the APCOs for tracking changes in CI(TD) was assessed with a 4-quadrant plot for directional changes and with receiver operating characteristic curves for specificity and sensitivity. The performance of both APCOs was poor in detecting increases and fair in detecting decreases in CI(TD). In conclusion, the calibrated and uncalibrated APCOs perform differently during OLT. Although the calibrated APCO is less influenced by changes in the systemic vascular resistance, neither device can be used interchangeably with thermodilution to monitor cardiac output during liver transplantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Navigated ultrasound (US) imaging is used for the intra-operative acquisition of 3D image data during imageguided surgery. The presented approach includes the design of a compact and easy to use US calibration device and its integration into a software application for navigated liver surgery. User interaction during the calibration process is minimized through automatic detection of the calibration process followed by automatic image segmentation, calculation of the calibration transform and validation of the obtained result. This leads to a fast, interaction-free and fully automatic calibration procedure enabling intra-operative