975 resultados para CRAC assay
Resumo:
BACKGROUND: Dermatophytes are the main cause of onychomycoses, but various nondermatophyte filamentous fungi are often isolated from abnormal nails. The correct identification of the aetiological agent of nail infections is necessary in order to recommend appropriate treatment. OBJECTIVE: To evaluate a rapid polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) assay based on 28S rDNA for fungal identification in nails on a large number of samples in comparison with cultures. METHODS: Infectious fungi were analysed using PCR-RFLP in 410 nail samples in which fungal elements were observed in situ by direct mycological examination (positive samples). The results were compared with those previously obtained by culture of fungi on Sabouraud agar from the same nail samples. RESULTS: PCR-RFLP identification of fungi in nails allowed validation of the results obtained in culture when Trichophyton spp. grew from infected samples. In addition, nondermatophyte filamentous fungi could be identified with certainty as the infectious agents in onychomycosis, and discriminated from dermatophytes as well as from transient contaminants. The specificity of the culture results relative to PCR-RFLP appeared to be 81%, 71%, 52% and 63% when Fusarium spp., Scopulariopsis brevicaulis, Aspergillus spp. and Candida spp., respectively, grew on Sabouraud agar. It was also possible to identify the infectious agent when direct nail mycological examination showed fungal elements, but negative results were obtained from fungal culture. CONCLUSIONS: Improved sensitivity for the detection of fungi in nails was obtained using the PCR-RFLP assay. Rapid and reliable molecular identification of the infectious fungus can be used routinely and presents several important advantages compared with culture in expediting the choice of appropriate antifungal therapy.
Resumo:
A multicomponent indicator displacement assay ( MIDA) based on an organometallic receptor and three dyes can be used for the identification and quantification of nucleotides in aqueous solution at neutral pH.
Resumo:
OBJECTIVES: Reactivation of latent tuberculosis (TB) in inflammatory bowel disease (IBD) patients treated with antitumor necrosis factor-alpha medication is a serious problem. Currently, TB screening includes chest x-rays and a tuberculin skin test (TST). The interferon-gamma release assay (IGRA) QuantiFERON-TB Gold In-Tube (QFT-G-IT) shows better specificity for diagnosing TB than the skin test. This study evaluates the two test methods among IBD patients. METHODS: Both TST and IGRA were performed on 212 subjects (114 Crohn's disease, 44 ulcerative colitis, 10 indeterminate colitis, 44 controls). RESULTS: Eighty-one percent of IBD patients were under immunosuppressive therapy; 71% of all subjects were vaccinated with Bacille Calmette Guérin; 18% of IBD patients and 43% of controls tested positive with the skin test (P < 0.0001). Vaccinated controls tested positive more often with the skin test (52%) than did vaccinated IBD patients (23%) (P = 0.011). Significantly fewer immunosuppressed patients tested positive with the skin test than did patients not receiving therapy (P = 0.007); 8% of patients tested positive with the QFT-G-IT test (14/168) compared to 9% (4/44) of controls. Test agreement was significantly higher in the controls (P = 0.044) compared to the IBD group. CONCLUSIONS: Agreement between the two test methods is poor in IBD patients. In contrast to the QFT-G-IT test, the TST is negatively influenced by immunosuppressive medication and vaccination status, and should thus be replaced by the IGRA for TB screening in immunosuppressed patients having IBD.
Resumo:
Agricultural practices, such as spreading liquid manure or the utilisation of land as animal pastures, can result in faecal contamination of water resources. Rhodococcus coprophilus is used in microbial source tracking to indicate animal faecal contamination in water. Methods previously described for detecting of R. coprophilus in water were neither sensitive nor specific. Therefore, the aim of this study was to design and validate a new quantitative polymerase chain reaction (qPCR) to improve the detection of R. coprophilus in water. The new PCR assay was based on the R. coprophilus 16S rRNA gene. The validation showed that the new approach was specific and sensitive for deoxyribunucleic acid from target host species. Compared with other PCR assays tested in this study, the detection limit of the new qPCR was between 1 and 3 log lower. The method, including a filtration step, was further validated and successfully used in a field investigation in Switzerland. Our work demonstrated that the new detection method is sensitive and robust to detect R. coprophilus in surface and spring water. Compared with PCR assays that are available in the literature or to the culture-dependent method, the new molecular approach improves the detection of R. coprophilus.
Resumo:
BACKGROUND: Antitumour necrosis factor (anti-TNF) treatments may reactivate latent tuberculosis infection (LTBI). For detecting LTBI, the tuberculin skin test (TST) has low sensitivity and specificity. Interferon-gamma release assays (IGRA) have been shown to be more sensitive and specific than TST. OBJECTIVE: To compare the TST and the T-SPOT.TB IGRA for identifying LTBI in patients with psoriasis before anti-TNF treatment. METHODS: A retrospective study was carried out over a 4-year period on patients with psoriasis requiring anti-TNF treatment. All were subjected to the TST, T-SPOT.TB and chest X-ray. Risk factors for LTBI and history of bacillus Calmette-Guérin (BCG) vaccination were recorded. The association of T-SPOT.TB and TST results with risk factors for LTBI was tested through univariate logistic regression models. Agreement between tests was quantified using kappa statistics. Treatment for LTBI was started 1 month before anti-TNF therapy when indicated. RESULTS: Fifty patients were included; 90% had prior BCG vaccination. A positive T-SPOT.TB was strongly associated with a presumptive diagnosis of LTBI (odds ratio 7.43; 95% confidence interval 1.38-39.9), which was not the case for the TST. Agreement between the T-SPOT.TB and TST was poor, kappa = 0.33 (SD 0.13). LTBI was detected and treated in 20% of the patients. In 20% of the cases, LTBI was not retained in spite of a positive TST but a negative T-SPOT.TB. All patients received an anti-TNF agent for a median of 56 weeks (range 20-188); among patients with a positive TST/negative T-SPOT.TB, no tuberculosis was detected with a median follow-up of 64 weeks (44-188). One case of disseminated tuberculosis occurred after 28 weeks of adalimumab treatment in a patient with LTBI in spite of treatment with rifampicin. CONCLUSION: This study is the first to underline the frequency of LTBI in patients with psoriasis (20%), and to support the use of IGRA instead of the TST for its detection. Nevertheless, there is still a risk of tuberculosis under anti-TNF therapy, even if LTBI is correctly diagnosed and treated.
Resumo:
We present the application of a real-time quantitative PCR assay, previously developed to measure relative telomere length in humans and mice, to two bird species, the zebra finch Taeniopygia guttata and the Alpine swift Apus melba. This technique is based on the PCR amplification of telomeric (TTAGGG)(n) sequences using specific oligonucleotide primers. Relative telomere length is expressed as the ratio (T/S) of telomere repeat copy number (T) to control single gene copy number (S). This method is particularly useful for comparisons of individuals within species, or where the same individuals are followed longitudinally. We used glyceraldehyde-3-phosphate dehydrogenase (GAPDH) as a single control gene. In both species, we validated our PCR measurements of relative telomere length against absolute measurements of telomere length determined by the conventional method of quantifying telomere terminal restriction fragment (TRF) lengths using both the traditional Southern blot analysis (Alpine swifts) and in gel hybridization (zebra finches). As found in humans and mice, telomere lengths in the same sample measured by TRF and PCR were well correlated in both the Alpine swift and the zebra finch.. Hence, this PCR assay for measurement of bird telomeres, which is fast and requires only small amounts of genomic DNA, should open new avenues in the study of environmental factors influencing variation in telomere length, and how this variation translates into variation in cellular and whole organism senescence.
Resumo:
Given the multiplicity of nanoparticles (NPs), there is a requirement to develop screening strategies to evaluate their toxicity. Within the EU-funded FP7 NanoTEST project, a panel of medically relevant NPs has been used to develop alternative testing strategies of NPs used in medical diagnostics. As conventional toxicity tests cannot necessarily be directly applied to NPs in the same manner as for soluble chemicals and drugs, we determined the extent of interference of NPs with each assay process and components. In this study, we fully characterized the panel of NP suspensions used in this project (poly(lactic-co-glycolic acid)-polyethylene oxide [PLGA-PEO], TiO2, SiO2, and uncoated and oleic-acid coated Fe3O4) and showed that many NP characteristics (composition, size, coatings, and agglomeration) interfere with a range of in vitro cytotoxicity assays (WST-1, MTT, lactate dehydrogenase, neutral red, propidium iodide, (3)H-thymidine incorporation, and cell counting), pro-inflammatory response evaluation (ELISA for GM-CSF, IL-6, and IL-8), and oxidative stress detection (monoBromoBimane, dichlorofluorescein, and NO assays). Interferences were assay specific as well as NP specific. We propose how to integrate and avoid interference with testing systems as a first step of a screening strategy for biomedical NPs.
Resumo:
BACKGROUND: Niemann-Pick type C (NP-C) is a rare progressive neurodegenerative lipid storage disorder with heterogeneous clinical presentation and challenging diagnostic procedures. Recently oxysterols have been reported to be specific biomarkers for NP-C but knowledge on the intra-individual variation and on reference intervals in children and adolescents are lacking. METHODS: We established a LC-MS/MS assay to measure Cholestane-3β, 5α, 6β-triol (C-triol) and 7-Ketocholesterol (7-KC) following Steglich esterification. To assess reference intervals and intra-individual variation we determined oxysterols in 148 children and adolescents from 0 to 18 years and repeat measurements in 19 of them. RESULTS: The reported method is linear (r>0.99), sensitive (detection limit of 0.03 ng/mL [0.07 nM] for C-triol, and 0.54 ng/mL [1.35 nM] for 7-KC) and precise, with an intra-day imprecision of 4.8% and 4.1%, and an inter-day imprecision of 7.0% and 11.0% for C-triol (28 ng/ml, 67 nM) and 7-KC (32 ng/ml, 80 nM), respectively. Recoveries for 7-KC and C-triol range between 93% and 107%. The upper reference limit obtained for C-triol is 40.4 ng/mL (95% CI: 26.4-61.7 ng/mL, 96.0 nM, 95% CI: 62.8-146.7 nM) and 75.0 ng/mL for 7-KC (95% CI: 55.5-102.5 ng/mL, 187.2 nM, 95% CI: 138.53-255.8 nM), with no age or gender dependency. Both oxysterols have a broad intra-individual variation of 46%±23% for C-triol and 52%±29% for 7-KC. Nevertheless, all Niemann-Pick patients showed increased C-triol levels including Niemann-Pick type A and B patients. CONCLUSIONS: The LC-MS/MS assay is a robust assay to quantify C-triol and 7-KC in plasma with well documented reference intervals in children and adolescents to screen for NP-C in the pediatric population. In addition our results suggest that especially the C-triol is a biomarker for all three Niemann-Pick diseases.
Resumo:
Detection of cryptococcal antigen in serum or cerebrospinal fluid allows cryptococcal meningitis diagnosis within few hours with >90% sensitivity. In an HIV-positive patient with Cryptococcus neoformans meningitis, initial antigen detection by immunoagglutination was negative. We thus evaluated a new immunochromatographic detection assay that exhibited a higher sensitivity.
Resumo:
To-date, there has been no effective chiral capillary electrophoresis-mass spectrometry (CE-MS) method reported for the simultaneous enantioseparation of the antidepressant drug, venlafaxine (VX) and its structurally-similar major metabolite, O-desmethylvenlafaxine (O-DVX). This is mainly due to the difficulty of identifying MS compatible chiral selector, which could provide both high enantioselectivity and sensitive MS detection. In this work, poly-sodium N-undecenoyl-L,L-leucylalaninate (poly-L,L-SULA) was employed as a chiral selector after screening several dipeptide polymeric chiral surfactants. Baseline separation of both O-DVX and VX enantiomers was achieved in 15min after optimizing the buffer pH, poly-L,L-SULA concentration, nebulizer pressure and separation voltage. Calibration curves in spiked plasma (recoveries higher than 80%) were linear over the concentration range 150-5000ng/mL for both VX and O-DVX. The limit of detection (LOD) was found to be as low as 30ng/mL and 21ng/mL for O-DVX and VX, respectively. This method was successfully applied to measure the plasma concentrations of human volunteers receiving VX or O-DVX orally when co-administered without and with indinivar therapy. The results suggest that micellar electrokinetic chromatography electrospray ionization-tandem mass spectrometry (MEKC-ESI-MS/MS) is an effective low cost alternative technique for the pharmacokinetics and pharmacodynamics studies of both O-DVX and VX enantiomers. The technique has potential to identify drug-drug interaction involving VX and O-DVX enantiomers while administering indinivar therapy.
Resumo:
Apoptosis is an essential cellular mechanism involved in many processes such as embryogenesis, metamorphosis, and tissue homeostasis. DNA fragmentation is one of the key markers of this form of cell death. DNA fragmentation is executed by endogenous endonucleases such as caspase-activated DNase (CAD) in caspase-dependent apoptosis. The TUNEL (TdT-mediated dUTP-biotin nick end labeling) technique is the most widely used method to identify apoptotic cells in a tissue or culture and to assess drug toxicity. It is based on the detection of 3'-OH termini that are labeled with dUTP by the terminal deoxynucleotidyl transferase. Although the test is very reliable and sensitive in caspase-dependent apoptosis, it is completely useless when cell death is mediated by pathways involving DNA degradation that generates 3'-P ends as in the LEI/L-DNase II pathway. Here, we propose a modification in the TUNEL protocol consisting of a dephosphorylation step prior to the TUNEL labeling. This allows the detection of both types of DNA breaks induced during apoptosis caspase-dependent and independent pathways, avoiding underestimating the cell death induced by the treatment of interest.
Resumo:
ELISAs have been applied to pesticide residue analysis due to their high sensitivity and selectivity. However, some ELISAs performance may be affected by matrix components. In this work, ELISA for carbaryl in water samples was checked for interference by naturally occurring fulvic acids. The results suggested that the high fulvic acid concentration (³30 mg L-1) and acidic pH conditions (pH 4.0) interfere with the signal detection decreasing the method sensitivity. A dilution of the samples and adjust to pH 8.0 are appropriate to minimize the matrix interferences in the ELISA method. Good correlation between ELISA and HPLC-DAD results was observed.