Objective. To provide recommendations for the core outcome domains that should be considered by investigators conducting clinical trials of the efficacy and effectiveness of treatments for chronic pain. Development of a core set of outcome domains would facilitate comparison and pooling of data, encourage more complete reporting of outcomes, simplify the preparation and review of research proposals and manuscripts, and allow clinicians to make informed decisions regarding the risks and benefits of treatment. Methods. Under the auspices of the Initiative on Methods, Measurement, and Pain Assessment in Clinical Trials (IMMPACT), 27 specialists from academia. governmental agencies, and the pharmaceutical industry participated in a consensus meeting and identified core outcome domains that should be considered in clinical trials of treatments for chronic pain. Conclusions. There was a consensus that chronic pain clinical trials should assess outcomes representing six core domains: (1) pain, (2) physical functioning, (3) emotional functioning, (4) participant ratings of improvement and satisfaction with treatment, (5) symptoms and adverse events, (6) participant disposition (e.g. adherence to the treatment regimen and reasons for premature withdrawal from the trial). Although consideration should be given to the assessment of each of these domains, there may be exceptions to the general recommendation to include all of these domains in chronic pain trials. When this occurs, the rationale for not including domains should be provided. It is not the intention of these recommendations that assessment of the core domains should be considered a requirement for approval of product applications by regulatory agencies or that a treatment must demonstrate statistically significant effects for all of the relevant core domains to establish evidence of its efficacy. (C) 2003 International Association for the Study of Pain.
Resumo:
A self-modulating mechanism by the hepatitis C virus (HCV) core protein has been suggested to influence the level of HCV replication, but current data on this subject are contradictory. We examined the effect of wild-type and mutated core protein on HCV IRES- and cap-dependent translation. The wild-type core protein was shown to inhibit both IRES- and cap-dependent translation in an in vitro system. This effect was duplicated in a dose-dependent manner with a synthetic peptide representing amino acids 1-20 of the HCV core protein. This peptide was able to bind to the HCV IRES as shown by a mobility shift assay. In contrast, a peptide derived from the hepatitis B virus (HBV) core protein that contained a similar proportion of basic residues was unable to inhibit translation or bind the HCV IRES. A recombinant vaccinia-HCV core virus was used to examine the effect of the HCV core protein on HCV IRES-dependent translation in cells and this was compared with the effects of an HBV core-recombinant vaccinia virus. In CV-1 and HuH7 cells, the HCV core protein inhibited translation directed by the IRES elements of HCV, encephalomyocarditis virus and classical swine fever virus as well as cap-dependent translation, whereas in HepG2 cells, only HCV IRES-dependent translation was affected. Thus, the ability of the HCV core protein to selectively inhibit HCV IRES-dependent translation is cell-specific. N-terminal truncated (aa 1-20) HCV core protein that was expressed from a novel recombinant vaccinia virus in cells abrogated the inhibitory phenotype of the core protein in vivo, consistent with the above in vitro data.
Resumo:
The use of thermodilution and other methods of monitoring in dogs during surgery and critical care was evaluated. Six Greyhounds were anaesthetised and then instrumented by placing a thermodilution catheter into the pulmonary artery via the jugular vein. A catheter in the dorsal pedal artery also permitted direct measurement of arterial pressures. Core body temperature (degreesC) and central venous pressure (mmHg) were measured, while cardiac output (mL/min/kg) and mean arterial pressure (mmHg) were calculated. A mid-line surgical incision was performed and the physiological parameters were monitored for a total of two hours. All physiological parameters generally declined, although significant increases (P<0.05) were noted for cardiac output following surgical incision. Central venous pressure was maintained at approximately 0mmHg by controlling an infusion of sterile saline. Core body temperature decreased from 37.1+/-0.6degreesC (once instrumented) to 36.6+/-0.60degreesC (at the end of the study), despite warming using heating pads. Physiological parameters indicative of patient viability will generally decline during surgery without intervention. This study describes an approach that can be undertaken in veterinary hospitals to accurately monitor vital signs in surgical and critical care patients.
Resumo:
The ability to generate enormous random libraries of DNA probes via split-and-mix synthesis on solid supports is an important biotechnological application of colloids that has not been fully utilized to date. To discriminate between colloid-based DNA probes each colloidal particle must be 'encoded' so it is distinguishable from all other particles. To this end, we have used novel particle synthesis strategies to produce large numbers of optically encoded particle suitable for DNA library synthesis. Multifluorescent particles with unique and reproducible optical signatures (i.e., fluorescence and light-scattering attributes) suitable for high-throughput flow cytometry have been produced. In the spectroscopic study presented here, we investigated the optical characteristics of multi-fluorescent particles that were synthesized by coating silica 'core' particles with up to six different fluorescent dye shells alternated with non-fluorescent silica 'spacer' shells. It was observed that the diameter of the particles increased by up to 20% as a result of the addition of twelve concentric shells and that there was a significant reduction in fluorescence emission intensities from inner shells as an increasing number of shells were deposited.
Resumo:
Since collaborative networked organisations are usually formed by independent and heterogeneous entities, it is natural that each member holds his own set of values, and that conflicts among partners might emerge because of some misalignment of values. In contrast, it is often stated in literature that the alignment between the value systems of members involved in collaborative processes is a prerequisite for successful co-working. As a result, the issue of core value alignment in collaborative networks started to attract attention. However, methods to analyse such alignment are lacking mainly because the concept of 'alignment' in this context is still ill defined and shows a multifaceted nature. As a contribution to the area, this article introduces an approach based on causal models and graph theory for the analysis of core value alignment in collaborative networks. The potential application of the approach is then discussed in the virtual organisations' breeding environment context.
Resumo:
Collaborative networks are typically formed by heterogeneous and autonomous entities, and thus it is natural that each member has its own set of core-values. Since these values somehow drive the behaviour of the involved entities, the ability to quickly identify partners with compatible or common core-values represents an important element for the success of collaborative networks. However, tools to assess or measure the level of alignment of core-values are lacking. Since the concept of 'alignment' in this context is still ill-defined and shows a multifaceted nature, three perspectives are discussed. The first one uses a causal maps approach in order to capture, structure, and represent the influence relationships among core-values. This representation provides the basis to measure the alignment in terms of the structural similarity and influence among value systems. The second perspective considers the compatibility and incompatibility among core-values in order to define the alignment level. Under this perspective we propose a fuzzy inference system to estimate the alignment level, since this approach allows dealing with variables that are vaguely defined, and whose inter-relationships are difficult to define. Another advantage provided by this method is the possibility to incorporate expert human judgment in the definition of the alignment level. The last perspective uses a belief Bayesian network method, and was selected in order to assess the alignment level based on members' past behaviour. An example of application is presented where the details of each method are discussed.
Resumo:
A avaliação estética da mama é um requisito em diversas aplicações médicas, nomeadamente no tratamento conservador do cancro da mama. Para ultrapassar as limitações de reprodutibilidade e praticabilidade dos métodos subjectivos correntes, foi recentemente desenvolvido um sistema inovador, assistido por computador para uso médico, denominado BCCT.core (Breast Cancer Conservative Treatment.cosmetic results), que prevê, automaticamente, o resultado estético do tratamento conservador do cancro da mama após intervenção [1]. Um dos grandes desafios no desenvolvimento de qualquer sistema computacional é desenhar interfaces de utilizador eficazes — fáceis de aprender, efectivas e que conduzam a uma experiência agradável. Neste trabalho, analisamos alguns dos aspectos mais importantes do desenho da interface do BCCT.core, relacionados com o estudo da interacção com o utilizador, em relação à funcionalidade e usabilidade, através de um questionário dirigido a utilizadores reais dentro do domínio da aplicação. O desempenho do sistema pôde assim ser avaliado por critérios claros, apoiado numa base sólida que permitiu avaliar a percepção humana relativamente à interface, conduzindo ao desenvolvimento de um sistema que apoia efectivamente os utilizadores na realização de tarefas. De uma forma geral pode concluir-se que a utilização de técnicas de interacção homem-computador na avaliação da funcionalidade e usabilidade do BCCT.core foram essenciais no sentido de o tornar mais usável, eficiente e com elevado grau de satisfação, neste caso particular, para o utilizador médico.
Resumo:
This paper is a contribution for the assessment and comparison of magnet properties based on magnetic field characteristics particularly concerning the magnetic induction uniformity in the air gaps. For this aim, a solver was developed and implemented to determine the magnetic field of a magnetic core to be used in Fast Field Cycling (FFC) Nuclear Magnetic Resonance (NMR) relaxometry. The electromagnetic field computation is based on a 2D finite-element method (FEM) using both the scalar and the vector potential formulation. Results for the magnetic field lines and the magnetic induction vector in the air gap are presented. The target magnetic induction is 0.2 T, which is a typical requirement of the FFC NMR technique, which can be achieved with a magnetic core based on permanent magnets or coils. In addition, this application requires high magnetic induction uniformity. To achieve this goal, a solution including superconducting pieces is analyzed. Results are compared with a different FEM program.
Resumo:
A CIF é um sistema de classificação adotado pela OMS, que serve de referência universal para descrever, avaliar e medir saúde e incapacidade, a nível individual e ao nível da população. Contudo, apesar do interesse internacional gerado em torno da CIF, esta é considerada uma classificação complexa e extensa, fato que despoletou a criação de core sets – listas de itens da CIF especificamente selecionados pela sua relevância na descrição e qualificação de uma determinada condição de saúde – como resposta a esta problemática. Até à data, foram desenvolvidos core sets para várias patologias comuns. Contudo, apesar do controlo motor ser uma área de investigação muito reconhecida nos últimos 20 anos, ainda não possui um core set próprio. Assim, o objetivo deste estudo é contribuir para o desenvolvimento de um core set, com base na CIF-CJ, dirigido para uma descrição abrangente das competências inerentes a crianças, dos 6 aos 18 anos de idade, com défices no controlo motor. Deste modo, recorreu-se a uma revisão da literatura sobre a temática em estudo, de modo a reunir informação para a construção de uma proposta a core set, posteriormente sujeita ao escrutínio de peritos, através do recurso ao método de Delphi. Após várias rondas, foi alcançado um consenso acerca da lista final de códigos CIF que constituem o core set final.
Resumo:
There is an imminent need for rapid methods to detect and determine pathogenic bacteria in food products as alternatives to the laborious and time-consuming culture procedures. In this work, an electrochemical immunoassay using iron/gold core/shell nanoparticles (Fe@Au) conjugated with anti-Salmonella antibodies was developed. The chemical synthesis and functionalization of magnetic and gold-coated magnetic nanoparticles is reported. Fe@Au nanoparticles were functionalized with different self-assembled monolayers and characterized using ultraviolet-visible spectrometry, transmission electron microscopy, and voltammetric techniques. The determination of Salmonella typhimurium, on screen-printed carbon electrodes, was performed by square-wave anodic stripping voltammetry through the use of CdS nanocrystals. The calibration curve was established between 1×101 and 1×106 cells/mL and the limit of detection was 13 cells/mL. The developed method showed that it is possible to determine the bacteria in milk at low concentrations and is suitable for the rapid (less than 1 h) and sensitive detection of S. typhimurium in real samples. Therefore, the developed methodology could contribute to the improvement of the quality control of food samples.
Resumo:
OBJECTIVE: To analyze the core group for sexually transmitted infections (STI) among college students. METHODS: Cross-sectional study carried out in a convenience sample comprising 711 college students of the public university of Morelos, Mexico, between 2001 and 2003. Sociodemographic and sexual behavior information were collected using self-applied questionnaires. Herpes simplex 2 (HSV-2) infection was tested in the blood. The number of sexual partners in the last year and cocaine consumption were used as indicators to construct the dependent variable "level of STI risk" in three categories: low, medium and high risk (core group). A multinomial analysis was conducted to evaluate whether different sex behaviors were associated with the variable "level of STI risk". RESULTS: There was significant association between HSV-2 seroprevalence and the variable "level of STI risk": 13%, 5.6% and 3.8% were found in high (core group), medium and low categories, respectively. There were gender differences regarding the core group. Men started having sexual intercourse earlier, had more sex partners, higher alcohol and drug consumption, higher frequency of sex intercourse with sex workers, exchanging sex for money, occasional and concurrent partners compared to women. CONCLUSIONS: The study findings suggest existing contextual characteristics in the study population that affect their sex behavior. In Mexico, the cultural conception of sexuality is determined mainly by gender differences where men engage in higher risky sexual behavior than women.
Resumo:
Introdução: Os padrões de movimento podem sofrer alterações por atraso no timing de ativação e/ou modificações na sequência de recrutamento muscular, predispondo o indivíduo a disfunções, nomeadamente a dor lombo-pélvica. Objetivo: Investigar o timing e o padrão de ativação de músculos do core abdominal, durante o movimento de extensão da anca, do membro dominante, em indivíduos com e sem dor lombo- pélvica crónica inespecífica. Pretende-se, também, pesquisar a existência do padrão de ativação considerado “normal“ e verificar a relação entre o padrão de ativação e o tilt pélvico, em ambos os indivíduos. Métodos: Estudo transversal, com 64 estudantes universitários, divididos em dois grupos: 31 sem e 33 com dor lombo-pélvica. Através de eletromiografia de superfície foi recolhida a atividade muscular dos Eretores da Espinha ipsilateral e contralateral, Glúteo Máximo e Bicípite Femoral ipsilaterais. Foi analisado o timing de ativação muscular e as respetivas ordens de ativação. Adicionalmente foi medido o tilt pélvico. Resultados: O grupo com dor lombo-pélvica apresentou um atraso significativo no timing de ativação dos músculos Glúteo Máximo ipsilateral (t=-3,171;p=0,002) e Bicípite Femoral ipsilateral (t=-2,092;p=0,041), em comparação com o grupo sem dor. Verificou-se uma associação significativa entre as 5 ordens de ativação mais frequentes e a presença de dor lombo-pélvica (xf2=11,54;p=0,015). A ordem de ativação "normal" – Glúteo Máximo ipsilateral>Bicípite Femoral ipsilateral>Eretor da Espinha contralateral>Eretor da Espinha ipsilateral – não foi utilizada. Verificou-se que o Bicípite Femoral ipsilateral foi maioritariamente o primeiro a ativar-se e o Glúteo Máximo ipsilateral o último em ambos os grupos. Verificou-se um tilt pélvico significativamente superior nos indivíduos que ativam primeiro o Bicípite Femoral ipsilateral nos grupos com (U=51;p=0,001) e sem dor (U=41p=0,001). Conclusão: Os indivíduos com dor lombo-pélvica apresentaram um atraso no timing de ativação dos músculos do core abdominal. Os resultados parecem refutar a ordem de ativação "normal" que tem sido proposta. Não foi possível apoiar nem contestar a teoria de que um atraso na ativação do Glúteo Máximo está associado com dor lombo-pélvica.
Resumo:
We consider a fiber made of a soft elastic material, encased in a stiff elastic shell (core-shell geometry). If the core and shell dimensions are mismatched, e.g., because the core shrinks while the shell does not, but the two remain attached, then an elastic instability is triggered whereby wrinkles may appear on the shell. The wrinkle orientation may be longitudinal (along the fiber axis), polar (along the fiber perimeter), or a mixture of both, depending on the fiber's geometrical and material parameters. Here we investigate under what conditions longitudinal or polar wrinkling will occur.
Resumo:
This paper is a contribution for the assessment and comparison of magnet properties based on magnetic field characteristics particularly concerning the magnetic induction uniformity in the air gaps. For this aim, a solver was developed and implemented to determine the magnetic field of a magnetic core to be used in Fast Field Cycling (FFC) Nuclear Magnetic Resonance (NMR) relaxometry. The electromagnetic field computation is based on a 2D finite-element method (FEM) using both the scalar and the vector potential formulation. Results for the magnetic field lines and the magnetic induction vector in the air gap are presented. The target magnetic induction is 0.2 T, which is a typical requirement of the FFC NMR technique, which can be achieved with a magnetic core based on permanent magnets or coils. In addition, this application requires high magnetic induction uniformity. To achieve this goal, a solution including superconducting pieces is analyzed. Results are compared with a different FEM program.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações