915 resultados para Bimanual Arm Movements


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mammalian sex chromosomes stem from ancestral autosomes and have substantially differentiated. It was shown that X-linked genes have generated duplicate intronless gene copies (retrogenes) on autosomes due to this differentiation. However, the precise driving forces for this out-of-X gene "movement" and its evolutionary onset are not known. Based on expression analyses of male germ-cell populations, we here substantiate and extend the hypothesis that autosomal retrogenes functionally compensate for the silencing of their X-linked housekeeping parental genes during, but also after, male meiotic sex chromosome inactivation (MSCI). Thus, sexually antagonistic forces have not played a major role for the selective fixation of X-derived gene copies in mammals. Our dating analyses reveal that although retrogenes were produced ever since the common mammalian ancestor, selectively driven retrogene export from the X only started later, on the placental mammal (eutherian) and marsupial (metatherian) lineages, respectively. Together, these observations suggest that chromosome-wide MSCI emerged close to the eutherian-marsupial split approximately 180 million years ago. Given that MSCI probably reflects the spread of the recombination barrier between the X and Y, crucial for their differentiation, our data imply that these chromosomes became more widely differentiated only late in the therian ancestor, well after the divergence of the monotreme lineage. Thus, our study also provides strong independent support for the recent notion that our sex chromosomes emerged, not in the common ancestor of all mammals, but rather in the therian ancestor, and therefore are much younger than previously thought

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé en français: Il est admis que l'inflation d'une manchette à pression au niveau du bras engendre une augmentation réactionnelle de la tension artérielle qui peut être le résultat d'une gêne lors de l'inflation et peut diminuer la précision de la mesure. Dans cette étude, nous comparons séquentiellement l'augmentation de la tension artérielle lorsque la manchette à pression est positionnée au niveau du bras et au niveau du poignet. Nous avons étudié un collectif de 34 participants normotendus et 34 patients hypertendus. Chacun d'eux était équipé de deux manchettes à pression, l'une au niveau du bras et l'autre au niveau du poignet. Nous avons randomisé l'ordre d'inflation des manchettes ainsi que la pression d'inflation maximale (180mmHg versus 240mmHg). Trois mesures étaient effectuées pour chaque pression d'inflation maximale, ceci au bras comme poignet, et leur séquence était également randomisée. En parallèle, un enregistrement continu de la tension artérielle avait lieu au niveau du majeur de la main opposée à l'aide d'un photoplethysmographe. Cette valeur était considérée comme la valeur de tension artérielle au repos. Pour les participants normotendus, aucune différence statistiquement significative n'a pu être mise en évidence en lien avec la position de la manchette à pression, ceci indépendamment de la pression d'inflation maximale. Variation de la pression systolique à 180 mmHg: 4.3+/-3.0 mmHg au bras et 3.7+/-2.9 mmHg au poignet (p=ns), à 240 mmHg: 5.5+/-3.9 au bras et 4.2+/-2.7 mmHg au poignet (p=0.052). En revanche, concernant les patients hypertendus, une augmentation significative de la tension artérielle a été mise en évidence entre le bras et le poignet. Ceci pour les valeurs de tension artérielle systolique et diastolique et quelle que soit la pression d'inflation maximale utilisée. Augmentation de la pression artérielle systolique 6.513.5 mmHg au bras et 3.812.1mmHg au poignet pour une pression d'inflation maximale de 180 mmHg (p<0.01) et respectivement 6.413.5 mmHg et 4.713.0 mmHg pour 240 mmHg (p=0.01). L'augmentation des valeurs de tension artérielle était indépendante de la valeur tensionnelle de base. Ces résultats montrent que les patients hypertendus réagissent significativement moins à l'inflation d'une manchette ä pression lorsque celle-ci est positionnée au niveau du poignet par rapport au bras, ceci indépendamment des valeurs de tension artérielle de base des patients. Nous pouvons donc suggérer que l'inflation d'une manchette à pression cause moins de désagrément lorsqu'elle est placée au niveau du poignet, notamment chez les patients hypertendus et qu'elle peut être une alternative à la mesure standard au niveau du bras.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction : Le monitoring de la tension artérielle à domicile est recommandé par plusieurs guidelines et a été montré être faisable chez la personne âgée. Les manomètres au poignet ont récemment été proposés pour la mesure de la tension artérielle à domicile, mais leur précision n'a pas été au préalable évaluée chez les patients âgés. Méthode : Quarante-huit participants (33 femmes et 15 hommes, moyenne d'âge 81.3±8.0 ans) ont leur tension artérielle mesurée avec un appareil au poignet avec capteur de position et un appareil au bras dans un ordre aléatoire et dans une position assise. Résultats : Les moyennes de mesures de tension artérielle étaient systématiquement plus basses avec l'appareil au poignet par rapport à celui du bras pour la pression systolique (120.1±2.2 vs. 130.5±2.2 mmHg, P < 0.001, moyenneidéviation standard) et pour la pression diastolique (66.011.3 vs. 69.7±1.3 mmHg, P < 0.001). De plus, une différence de lOmmHg ou plus grande entre l'appareil au bras et au poignet était observée dans 54.2 et 18,8% des mesures systoliques et diastoliques respectivement. Conclusion : Comparé à l'appareil au bras, l'appareil au poignet avec capteur de position sous-estimait systématiquement aussi bien la tension artérielle systolique que diastolique. L'ampleur de la différence est cliniquement significative et met en doute l'utilisation de l'appareil au poignet pour monitorer la tension artérielle chez la personne âgée. Cette étude indique le besoin de valider les appareils de mesures de la tension artérielle dans tous les groupes d'âge, y compris les personnes âgées.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current research on sleep using experimental animals is limited by the expense and time-consuming nature of traditional EEG/EMG recordings. We present here an alternative, noninvasive approach utilizing piezoelectric films configured as highly sensitive motion detectors. These film strips attached to the floor of the rodent cage produce an electrical output in direct proportion to the distortion of the material. During sleep, movement associated with breathing is the predominant gross body movement and, thus, output from the piezoelectric transducer provided an accurate respiratory trace during sleep. During wake, respiratory movements are masked by other motor activities. An automatic pattern recognition system was developed to identify periods of sleep and wake using the piezoelectric generated signal. Due to the complex and highly variable waveforms that result from subtle postural adjustments in the animals, traditional signal analysis techniques were not sufficient for accurate classification of sleep versus wake. Therefore, a novel pattern recognition algorithm was developed that successfully distinguished sleep from wake in approximately 95% of all epochs. This algorithm may have general utility for a variety of signals in biomedical and engineering applications. This automated system for monitoring sleep is noninvasive, inexpensive, and may be useful for large-scale sleep studies including genetic approaches towards understanding sleep and sleep disorders, and the rapid screening of the efficacy of sleep or wake promoting drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Phase-IV, open-label, single-arm study (NCT01203917) to assess efficacy and safety/tolerability of first-line gefitinib in Caucasian patients with stage IIIA/B/IV, epidermal growth factor receptor (EGFR) mutation-positive non-small-cell lung cancer (NSCLC). METHODS Treatment: gefitinib 250 mg day(-1) until progression. Primary endpoint: objective response rate (ORR). Secondary endpoints: disease control rate (DCR), progression-free survival (PFS), overall survival (OS) and safety/tolerability. Pre-planned exploratory objective: EGFR mutation analysis in matched tumour and plasma samples. RESULTS Of 1060 screened patients with NSCLC (859 known mutation status; 118 positive, mutation frequency 14%), 106 with EGFR sensitising mutations were enrolled (female 70.8%; adenocarcinoma 97.2%; never-smoker 64.2%). At data cutoff: ORR 69.8% (95% confidence interval (CI) 60.5-77.7), DCR 90.6% (95% CI 83.5-94.8), median PFS 9.7 months (95% CI 8.5-11.0), median OS 19.2 months (95% CI 17.0-NC; 27% maturity). Most common adverse events (AEs; any grade): rash (44.9%), diarrhoea (30.8%); CTC (Common Toxicity Criteria) grade 3/4 AEs: 15%; SAEs: 19%. Baseline plasma 1 samples were available in 803 patients (784 known mutation status; 82 positive; mutation frequency 10%). Plasma 1 EGFR mutation test sensitivity: 65.7% (95% CI 55.8-74.7). CONCLUSION First-line gefitinib was effective and well tolerated in Caucasian patients with EGFR mutation-positive NSCLC. Plasma samples could be considered for mutation analysis if tumour tissue is unavailable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Phase-IV, open-label, single-arm study (NCT01203917) to assess efficacy and safety/tolerability of first-line gefitinib in Caucasian patients with stage IIIA/B/IV, epidermal growth factor receptor (EGFR) mutation-positive non-small-cell lung cancer (NSCLC). METHODS: TREATMENT: gefitinib 250 mg day(-1) until progression. Primary endpoint: objective response rate (ORR). Secondary endpoints: disease control rate (DCR), progression-free survival (PFS), overall survival (OS) and safety/tolerability. Pre-planned exploratory objective: EGFR mutation analysis in matched tumour and plasma samples. RESULTS: Of 1060 screened patients with NSCLC (859 known mutation status; 118 positive, mutation frequency 14%), 106 with EGFR sensitising mutations were enrolled (female 70.8%; adenocarcinoma 97.2%; never-smoker 64.2%). At data cutoff: ORR 69.8% (95% confidence interval (CI) 60.5-77.7), DCR 90.6% (95% CI 83.5-94.8), median PFS 9.7 months (95% CI 8.5-11.0), median OS 19.2 months (95% CI 17.0-NC; 27% maturity). Most common adverse events (AEs; any grade): rash (44.9%), diarrhoea (30.8%); CTC (Common Toxicity Criteria) grade 3/4 AEs: 15%; SAEs: 19%. Baseline plasma 1 samples were available in 803 patients (784 known mutation status; 82 positive; mutation frequency 10%). Plasma 1 EGFR mutation test sensitivity: 65.7% (95% CI 55.8-74.7). CONCLUSION: First-line gefitinib was effective and well tolerated in Caucasian patients with EGFR mutation-positive NSCLC. Plasma samples could be considered for mutation analysis if tumour tissue is unavailable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.