972 resultados para Automated sorting system
Resumo:
A method of automatically identifying and tracking polar-cap plasma patches, utilising data inversion and feature-tracking methods, is presented. A well-established and widely used 4-D ionospheric imaging algorithm, the Multi-Instrument Data Assimilation System (MIDAS), inverts slant total electron content (TEC) data from ground-based Global Navigation Satellite System (GNSS) receivers to produce images of the free electron distribution in the polar-cap ionosphere. These are integrated to form vertical TEC maps. A flexible feature-tracking algorithm, TRACK, previously used extensively in meteorological storm-tracking studies is used to identify and track maxima in the resulting 2-D data fields. Various criteria are used to discriminate between genuine patches and "false-positive" maxima such as the continuously moving day-side maximum, which results from the Earth's rotation rather than plasma motion. Results for a 12-month period at solar minimum, when extensive validation data are available, are presented. The method identifies 71 separate structures consistent with patch motion during this time. The limitations of solar minimum and the consequent small number of patches make climatological inferences difficult, but the feasibility of the method for patches larger than approximately 500 km in scale is demonstrated and a larger study incorporating other parts of the solar cycle is warranted. Possible further optimisation of discrimination criteria, particularly regarding the definition of a patch in terms of its plasma concentration enhancement over the surrounding background, may improve results.
Resumo:
Research evaluating perceptual responses to music has identified many structural features as correlates that might be incorporated in computer music systems for affectively charged algorithmic composition and/or expressive music performance. In order to investigate the possible integration of isolated musical features to such a system, a discrete feature known to correlate some with emotional responses – rhythmic density – was selected from a literature review and incorporated into a prototype system. This system produces variation in rhythm density via a transformative process. A stimulus set created using this system was then subjected to a perceptual evaluation. Pairwise comparisons were used to scale differences between 48 stimuli. Listener responses were analysed with Multidimensional scaling (MDS). The 2-Dimensional solution was then rotated to place the stimuli with the largest range of variation across the horizontal plane. Stimuli with variation in rhythmic density were placed further from the source material than stimuli that were generated by random permutation. This, combined with the striking similarity between the MDS scaling and that of the 2-dimensional emotional model used by some affective algorithmic composition systems, suggests that isolated musical feature manipulation can now be used to parametrically control affectively charged automated composition in a larger system.
Resumo:
Temperature, pressure, gas stoichiometry, and residence time were varied to control the yield and product distribution of the palladium-catalyzed aminocarbonylation of aromatic bromides in both a silicon microreactor and a packed-bed tubular reactor. Automation of the system set points and product sampling enabled facile and repeatable reaction analysis with minimal operator supervision. It was observed that the reaction was divided into two temperature regimes. An automated system was used to screen steady-state conditions for offline analysis by gas chromatography to fit a reaction rate model. Additionally, a transient temperature ramp method utilizing online infrared analysis was used, leading to more rapid determination of the reaction activation energy of the lower temperature regimes. The entire reaction spanning both regimes was modeled in good agreement with the experimental data.
Resumo:
Policy hierarchies and automated policy refinement are powerful approaches to simplify administration of security services in complex network environments. A crucial issue for the practical use of these approaches is to ensure the validity of the policy hierarchy, i.e. since the policy sets for the lower levels are automatically derived from the abstract policies (defined by the modeller), we must be sure that the derived policies uphold the high-level ones. This paper builds upon previous work on Model-based Management, particularly on the Diagram of Abstract Subsystems approach, and goes further to propose a formal validation approach for the policy hierarchies yielded by the automated policy refinement process. We establish general validation conditions for a multi-layered policy model, i.e. necessary and sufficient conditions that a policy hierarchy must satisfy so that the lower-level policy sets are valid refinements of the higher-level policies according to the criteria of consistency and completeness. Relying upon the validation conditions and upon axioms about the model representativeness, two theorems are proved to ensure compliance between the resulting system behaviour and the abstract policies that are modelled.
Resumo:
This paper describes the development and evaluation of a sequential injection method to automate the determination of methyl parathion by square wave adsorptive cathodic stripping voltammetry exploiting the concept of monosegmented flow analysis to perform in-line sample conditioning and standard addition. Accumulation and stripping steps are made in the sample medium conditioned with 40 mmol L-1 Britton-Robinson buffer (pH 10) in 0.25 mol L-1 NaNO3. The homogenized mixture is injected at a flow rate of 10 mu Ls(-1) toward the flow cell, which is adapted to the capillary of a hanging drop mercury electrode. After a suitable deposition time, the flow is stopped and the potential is scanned from -0.3 to -1.0 V versus Ag/AgCl at frequency of 250 Hz and pulse height of 25 mV The linear dynamic range is observed for methyl parathion concentrations between 0.010 and 0.50 mgL(-1), with detection and quantification limits of 2 and 7 mu gL(-1), respectively. The sampling throughput is 25 h(-1) if the in line standard addition and sample conditioning protocols are followed, but this frequency can be increased up to 61 h(-1) if the sample is conditioned off-line and quantified using an external calibration curve. The method was applied for determination of methyl parathion in spiked water samples and the accuracy was evaluated either by comparison to high performance liquid chromatography with UV detection, or by the recovery percentages. Although no evidences of statistically significant differences were observed between the expected and obtained concentrations, because of the susceptibility of the method to interference by other pesticides (e.g., parathion, dichlorvos) and natural organic matter (e.g., fulvic and humic acids), isolation of the analyte may be required when more complex sample matrices are encountered. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
The aim of this study was to assess and apply a microsatellite multiplex system for parentage determination in alpacas. An approach for parentage testing based on 10 microsatellites was evaluated in a population of 329 unrelated alpacas from different geographical zones in Peru. All microsatellite markers, which amplified in two multiplex reactions, were highly polymorphic with a mean of 14.5 alleles per locus (six to 28 alleles per locus) and an average expected heterozygosity (H-E) of 0.8185 (range of 0.698-0.946). The total parentage exclusion probability was 0.999456 for excluding a candidate parent from parentage of an arbitrary offspring, given only the genotype of the offspring, and 0.999991 for excluding a candidate parent from parentage of an arbitrary offspring, given the genotype of the offspring and the other parent. In a case test of parentage assignment, the microsatellite panel assigned 38 (from 45 cases) offspring parentage to 10 sires with LOD scores ranging from 2.19 x 10(+13) to 1.34 x 10(+15) and Delta values ranging from 2.80 x 10(+12) to 1.34 x 10(+15) with an estimated pedigree error rate of 15.5%. The performance of this multiplex panel of markers suggests that it will be useful in parentage testing of alpacas.
Resumo:
A simple, rapid, and automated assay for hydrogen peroxide in pharmaceutical samples was developed by combining the multicommutation system with a chemiluminescence (CL) detector. The detection was performed using a spiral flow-cell reactor made from polyethylene tubing that was positioned in front of a photodiode. It allows the rapid mixing of CL reagent and analyte and simultaneous detection of the emitted light. The chemiluminescence was based on the reaction of luminol with hydrogen peroxide catalyzed by hexacyanoferrate(III). The feasibility of the flow system was ascertained by analyzing a set of pharmaceutical samples. A linear response within the range of 2.2-210 μmol l-1 H2O2 with a LD of 1.8 μmol l-1 H2O2 and coefficient of variations smaller than 0.8% for 1.0×10-5 mol l-1 and 6.8×10-5 mol l-1 hydrogen peroxide solutions (n=10) were obtained. Reagents consumption of 90 μg of luminol and 0.7 mg of hexacyanoferrate(III) per determination and sampling rate of 200 samples per hour were also achieved. Copyright © Taylor & Francis Group, LLC.
Resumo:
The present study evaluated by cone-beam computed tomography (CBCT) the apical canal transportation and centralizing ability of different automated systems after root canal preparation. The mesiobuccal canals of maxillary first molars (n=10 per group) were prepared with: GI - reciprocating system with K-Flexofile; GII - reciprocating system with NiTiFlex files; GIII - rotary system with K3 instruments; GIV - rotary system with RaCe instruments. CBCT scans were taken before and after biomechanical preparation up to a #40.02 diameter. Canal transportation was determined by measuring the smallest distance between the inner canal walls and the mesial and distal sides of the root. The centralization ability corresponded to the difference between the measurements from transportation evaluation, using the linear voxel to voxel method of analysis. The mean transportation was 0.06 ± 0.14 mm, with a tendency to deviate to the mesial side of the root (n=22), with no statistically significant difference among the groups (p=0.4153). The mean centralization index was 0.15 ± 0.65 also without statistically significant difference among the groups (p=0.0881). It may be concluded that apical canal transportation and centralization ability were not influenced by the type of mechanical movement and instruments used.
Resumo:
In this paper, a methodology based on Unconstrained Binary Programming (UBP) model and Genetic Algorithms (GAs) is proposed for estimating fault sections in automated distribution substations. The UBP model, established by using the parsimonious set covering theory, looks for the match between the relays' protective alarms informed by the SCADA system and their expected states. The GA is developed to minimize the UBP model and estimate the fault sections in a swift and reliable manner. The proposed methodology is tested by utilizing a real-life automated distribution substation. Control parameters of the GA are tuned to achieve maximum computational efficiency and reduction of processing time. Results show the potential and efficiency of the methodology for estimating fault section in real-time at Distribution Control Centers. ©2009 IEEE.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Traditional abduction imposes as a precondition the restriction that the background information may not derive the goal data. In first-order logic such precondition is, in general, undecidable. To avoid such problem, we present a first-order cut-based abduction method, which has KE-tableaux as its underlying inference system. This inference system allows for the automation of non-analytic proofs in a tableau setting, which permits a generalization of traditional abduction that avoids the undecidable precondition problem. After demonstrating the correctness of the method, we show how this method can be dynamically iterated in a process that leads to the construction of non-analytic first-order proofs and, in some terminating cases, to refutations as well.
Resumo:
The software Seed Vigor Imaging System (SVIS®), has been successfully used to evaluate seed physiological potential by automated analyses of scanned seedlings. In this research, the efficiency of this system was compared to other tests accepted for assessing cucumber (Cucumis sativus L.) seed vigor of distinct seed lots of Supremo and Safira cultivars. Seeds were subjected to germination, traditional and saturated salt accelerated aging, seedling emergence, seedling length and SVIS analyses (determination of vigor indices and seedling growth uniformity, lengths of primary root, hypocotyl and whole seedlings). It was also determined whether the definition of seedling growth/uniformity ratios affects the sensitivity of the SVIS®. Results showed that analyses SVIS have provided consistent identification of seed lots performance, and have produced information comparable to those from recommended seed vigor tests, thus demonstrating a suitable sensitivity for a rapid and objective evaluation of physiological potential of cucumber seeds. Analyses of four-days-old cucumber seedlings using the SVIS® are more accurate and growth/uniformity does not affect the precision of results.
Resumo:
Aufbau einer kontinuierlichen, mehrdimensionalen Hochleistungs-flüssigchromatographie-Anlage für die Trennung von Proteinen und Peptiden mit integrierter größenselektiver ProbenfraktionierungEs wurde eine mehrdimensionale HPLC-Trennmethode für Proteine und Peptide mit einem Molekulargewicht von <15 kDa entwickelt.Im ersten Schritt werden die Zielanalyte von höhermolekularen sowie nicht ionischen Bestandteilen mit Hilfe von 'Restricted Access Materialien' (RAM) mit Ionenaustauscher-Funktionalität getrennt. Anschließend werden die Proteine auf einer analytischen Ionenaustauscher-Säule sowie auf Reversed-Phase-Säulen getrennt. Zur Vermeidung von Probenverlusten wurde ein kontinuierlich arbeitendes, voll automatisiertes System auf Basis unterschiedlicher Trenngeschwindigkeiten und vier parallelen RP-Säulen aufgebaut.Es werden jeweils zwei RP-Säulen gleichzeitig, jedoch mit zeitlich versetztem Beginn eluiert, um durch flache Gradienten ausreichende Trennleistungen zu erhalten. Während die dritte Säule regeneriert wird, erfolgt das Beladen der vierte Säule durch Anreicherung der Proteine und Peptide am Säulenkopf. Während der Gesamtanalysenzeit von 96 Minuten werden in Intervallen von 4 Minuten Fraktionen aus der 1. Dimension auf die RP-Säulen überführt und innerhalb von 8 Minuten getrennt, wobei 24 RP-Chromatogramme resultieren.Als Testsubstanzen wurden u.a. Standardproteine, Proteine und Peptide aus humanem Hämofiltrat sowie aus Lungenfibroblast-Zellkulturüberständen eingesetzt. Weiterhin wurden Fraktionen gesammelt und mittels MALDI-TOF Massenspektrometrie untersucht. Bei einer Injektion wurden in den 24 RP-Chromatogrammen mehr als 1000 Peaks aufgelöst. Der theoretische Wert der Peakkapazität liegt bei ungefähr 3000.