982 resultados para Atrial flutter
Resumo:
Ventilator-associated pneumonia (VAP) affects mortality, morbidity and cost of critical care. Reliable risk estimation might improve end-of-life decisions, resource allocation and outcome. Several scoring systems for survival prediction have been established and optimised over the last decades. Recently, new biomarkers have gained interest in the prognostic field. We assessed whether midregional pro-atrial natriuretic peptide (MR-proANP) and procalcitonin (PCT) improve the predictive value of the Simplified Acute Physiologic Score (SAPS) II and Sequential Related Organ Failure Assessment (SOFA) in VAP. Specified end-points of a prospective multinational trial including 101 patients with VAP were analysed. Death <28 days after VAP onset was the primary end-point. MR-proANP and PCT were elevated at the onset of VAP in nonsurvivors compared with survivors (p = 0.003 and p = 0.017, respectively) and their slope of decline differed significantly (p = 0.018 and p = 0.039, respectively). Patients with the highest MR-proANP quartile at VAP onset were at increased risk for death (log rank p = 0.013). In a logistic regression model, MR-proANP was identified as the best predictor of survival. Adding MR-proANP and PCT to SAPS II and SOFA improved their predictive properties (area under the curve 0.895 and 0.880). We conclude that the combination of two biomarkers, MR-proANP and PCT, improve survival prediction of clinical severity scores in VAP.
Resumo:
The diuretic and natriuretic responses to exogenous synthetic atrial natriuretic peptide (ANP) were evaluated in patients with chronic renal failure (CRF) or nephrotic syndrome (NS). Patients were studied after an oral water load (8 ml/kg in CRF and 20 ml/kg in NS patients). A short intravenous bolus of either a placebo or ANP was administered when urine output was stable. In each group of patients, three doses of ANP were injected at 24 h intervals, i.e., 1.0, 1.5, and 2.0 micrograms/kg in the CRF and 1.0, 1.5, and 3.0 micrograms/kg in the NS group. Blood pressure and heart rate were monitored throughout the study and urinary volume and electrolyte excretion were measured every 20 min up to 3 h after the bolus. An acute and transient fall in blood pressure was observed immediately after the ANP injection. It was more pronounced in CRF than in NS patients. In CRF patients, ANP caused only a slight increase in urinary volume (13.5-44% over baseline) but a significant increase in urinary sodium excretion (45-114% over baseline). In NS patients, significant increases in both urine volume (60-105%) and sodium excretion (149-248%) were also found. In these latter patients, the renal response to ANP appeared to be better preserved. The hemodynamic and renal changes induced by ANP occurred mainly during the first 20 min following the ANP administration, when the peak plasma ANP levels were obtained. However, no clear dose-response effect could be evidenced in either group with the three doses of ANP chosen in this study.
Resumo:
It has been shown that repolarization alternans, a beat-to-beat alternation in action potential duration, enhances dispersion of repolarization above a critical heart rate and promotes susceptibility to ventricular arrhythmias. It is unknown whether repolarization alternans is measurable in the atria using standard pacemakers and whether it plays a role in promoting atrial fibrillation. In this work, atrial repolarization alternans amplitude and periodicity are studied in a sheep model of pacing-induced atrial fibrillation. Two pacemakers, each with one right atrial and ventricular lead, were implanted in 4 male sheep after ablation of the atrioventricular junction. The first one was used to deliver rapid pacing for measurements of right atrial repolarization alternans and the second one to record a unipolar electrogram. Atrial repolarization alternans appeared rate-dependent and its amplitude increased as a function of pacing rate. Repolarization alternans was intermittent but no periodicity was detected. An increase of repolarization alternans preceding episodes of non-sustained atrial fibrillation suggests that repolarization alternans is a promising parameter for assessment of atrial fibrillation susceptibility.
Resumo:
The renal site of the natriuretic effect of human, atrial natriuretic peptide (hANP) was studied using clearance techniques in eight salt-loaded normal volunteers undergoing maximal water diuresis. Lithium was used as a marker of proximal sodium reabsorption. According to a two-way, single blind, crossover design, hANP (Met12-(3-28)-eicosahexapeptide, (2 micrograms/min) or its vehicle (Ve) were infused for two hours, followed by a two-hour recovery period. Blood pressure, heart rate and insulin clearance remained unchanged. During hANP infusion, the filtration fraction increased slightly from 19.6 to 24.3% (P less than 0.001), fractional water excretion rose transiently at the beginning of the infusion. Fractional excretion of sodium increased markedly from 2.2% to 7.4% (P less than 0.001) but remained unchanged with Ve. ANP increased fractional excretion of lithium slightly from 46 to 58% (P less than 0.01), while it remained stable at 47% during Ve. The distal tubular rejection fraction of sodium calculated from sodium and lithium clearances rose markedly from 4.7 to 13% (P less than 0.001) and returned to 6.2% at the end of the recovery period. Thus, under salt loading and water diuresis conditions, hANP infusion did not alter GFR, but reduced proximal reabsorption of sodium, and markedly enhanced the fraction of sodium escaping distal tubular reabsorption, suggesting that hANP-induced natriuresis is due, for an important part, to inhibition of sodium reabsorption in the distal nephron.
Resumo:
Intracardiac organization indices such as atrial fibrillation (AF) cycle length (AFCL) have been used to track the efficiency of stepwise catheter ablation (step-CA) of longstanding persistent AF, however with limited success. The morphology of AF activation waves reflects the underlying activation patterns. Its temporal evolution is a local organization indicator that could be potentially used for tracking the efficiency of step-CA. We report a new method for characterizing the structure of the temporal evolution of activation wave morphology. Using recurrence plots, novel organization indices are proposed. By computing their relative evolution during the first step of ablation vs baseline, we found that these new parameters are superior to AFCL to track the effect of step-CA "en route" to AF termination.
Resumo:
Kinetics of Atrial Repolarization Alternans. INTRODUCTION: Repolarization alternans (Re-ALT), a beat-to-beat alternation in action potential repolarization, promotes dispersion of repolarization, wavebreaks, and reentry. Recently, Re-ALT has been shown to play an important role in the transition from rapid pacing to atrial fibrillation (AF) in humans. The detailed kinetics of atrial Re-ALT, however, has not been reported so far. We developed a chronic free-behaving ovine pacing model to study the kinetics of atrial Re-ALT as a function of pacing rate. METHODS: Thirteen sheep were chronically implanted with 2 pacemakers for the recording of broadband right atrial unipolar electrograms and delivery of rapid pacing protocols. Beat-to-beat differences in the atrial T-wave apex amplitude as a measure of Re-ALT and activation time were analyzed at incremental pacing rates until the effective refractory period (ERP) defined as stable 2:1 capture. RESULTS: Atrial Re-ALT appeared intermittently but without periodicity, and increased in amplitude as a function of pacing rate until ERP. Intermittent 2:1 atrial capture was observed at pacing cycle lengths 40 ms above ERP, and increased in duration as a function of pacing rate. Episodes of rapid pacing-induced AF were rare, and were preceded by Re-ALT or complex oscillations of atrial repolarization, but without intermittent capture. CONCLUSION: We show in vivo that atrial Re-ALT developed and increased in magnitude with rate until stable 2:1 capture. In rare instances where capture failure did not occur, Re-ALT and complex oscillations of repolarization surged and preceded AF initiation. (J Cardiovasc Electrophysiol, Vol. 23, pp. 1003-1012, September 2012).
Resumo:
Chronic atrial fibrillation affects millions of people worldwide. Its surgical treatment often fails to restore the transport function of the atrium. This study first introduces the concept of an atrial assist device (AAD) to restore the pump function of the atrium. The AAD is developed to be totally implantable in the human body with a transcutaneous energy transfer system to recharge the implanted battery. The ADD consists of a motorless pump based on artificial muscle technology, positioned on the external surface of the atrium to compress it and restore its muscular activity. A bench model reproduces the function of a fibrillating atrium to assess the circulatory support that this pump can provide. Atripump (Nanopowers SA, Switzerland) is a dome-shaped silicone-coated nitinol actuator 5 mm high, sutured on the external surface of the atrium. A pacemaker-like control unit drives the actuator that compresses the atrium, providing the mechanical support to the blood circulation. Electrical characteristics: the system is composed of one actuator that needs a minimal tension of 15 V and has a maximum current of 1.5 A with a 50% duty cycle. The implantable rechargeable battery is made of a cell having the following specifications: nominal tension of a cell: 4.1 V, tension after 90% of discharge: 3.5 V, nominal capacity of a cell: 163 mA h. The bench model consists of an open circuit made of latex bladder 60 mm in diameter filled with water. The bladder is connected to a vertically positioned tube that is filled to different levels, reproducing changes in cardiac preload. The Atripump is placed on the outer surface of the bladder. Pressure, volume and temperature changes were recorded. The contraction rate was 1 Hz with a power supply of 12 V, 400 mA for 200 ms. Preload ranged from 15 to 21 cm H(2)O. Maximal silicone membrane temperature was 55 degrees C and maximal temperature of the liquid environment was 35 degrees C. The pump produced a maximal work of 16 x 10(-3) J. Maximal volume pumped was 492 ml min(-1). This artificial muscle pump is compact, follows the Starling law and reproduces the hemodynamic performances of a normal atrium. It could represent a new tool to restore the atrial kick in persistent atrial fibrillation.
Resumo:
The effects of intranasal administration of increasing doses of synthetic human natriuretic peptide (4-28 hANP) were studied in six healthy volunteers. The peptide was administered as a nasal spray at doses of 50, 100, 200, and 500 micrograms in ascending order at 48-h intervals. Vehicle was administered by the same route randomly between any two of the doses. Intranasal hANP administration had no effect on either blood pressure, heart rate (HR), or hematocrit. Diuresis did not change consistently, whereas natriuresis tended to rise with vehicle as well as with hANP administration. This was attributed to the infusion of isotonic saline during the experiment. There was no significant increase in plasma ANP levels after intranasal administration of any of the different doses. Thus, no evidence that the atrial natriuretic peptide tested (4-28 hANP) can cross the nasal mucosal barrier was found.
Resumo:
Atrial septal defect (ASD) typically is asymptomatic in infancy and early childhood and elective defect closure usually is performed at an age between 4 - 6 years. Severe pulmonary hypertension (PHT) complicating an ASD is seen in adulthood and has only occasionally been reported in small children. A retrospective study was undertaken to evaluate the incidence of severe PHT complicating an isolated ASD and requiring early surgical correction in the fi rst year of life. 355 pediatric patients underwent treatment for an isolated ASD either surgically or by catheter intervention during a 10 year period (1996 - 2006) at two tertiary referral centers. 297 patients had secundum ASD and 58 primum ASD with mild to moderate mitral regurgitation. 8 infants were found with isolated ASD (six with secundum and two with primum ASD) associated with signifi cant PHT, accounting for 2.2% of all ASD patients in our centers. These 8 infants had invasively measured pulmonary artery pressures between 50 and 100% of systemic pressure. Median size of the ASD at the time of surgery was 14mm (7 - 20). They were operated in the fi rst year of life and had complicated postoperative courses requiring specifi c treatment for PHT for up to 16 weeks (median 12) postoperatively. Compared to ASD patients without PHT these infants had prolonged postoperative ICU stay of 5 - 9 days (median 8) and prolonged perioperative overall hospital stay of 8 - 32 days (median 15). Ultimate outcome in all 8 infants was good with persistent normalization of pulmonary pressures during mid-term follow-up of between 8 to 60 months (median 28). All other ASD patients had normal pulmonary pressures and mean age at defect closure was higher being 6.2 years for secundum ASD and 3.2 years for primum ASD. In conclusion, ASD is rarely associated with signifi cant PHT in infancy but then requires early surgery to normalize the prognosis of the patients.
Resumo:
Atrial septal defects (ASDs) are typically asymptomatic in infancy and early childhood, and elective defect closure is usually performed at ages of 4 to 6 years. Severe pulmonary hypertension (PH) complicating an ASD is seen in adulthood and has only occasionally been reported in small children. A retrospective study was undertaken to evaluate the incidence of severe PH complicating an isolated ASD and requiring early surgical correction. During a 10-year period (1996 to 2006), 355 pediatric patients underwent treatment for isolated ASDs either surgically or by catheter intervention at 2 tertiary referral centers. Two hundred ninety-seven patients had secundum ASDs, and 58 had primum ASDs with mild to moderate mitral regurgitation. Eight infants were found with isolated ASDs (6 with secundum ASDs and 2 with primum ASDs) associated with significant PH, accounting for 2.2% of all patients with ASDs at the centers. These 8 infants had invasively measured pulmonary artery pressures of 50% to 100% of systemic pressure. They were operated in the first year of life and had complicated postoperative courses requiring specific treatment for PH for up to 16 weeks postoperatively. The ultimate outcomes in all 8 infants were good, with persistent normalization of pulmonary pressures during midterm follow-up of up to 60 months (median 28). All other patients with ASDs had normal pulmonary pressures, and the mean age at defect closure was significantly older, at 6.2 years for secundum ASDs and 3.2 years for primum ASDs. In conclusion, ASDs were rarely associated with significant PH in infancy but then required early surgery and were associated with excellent midterm outcomes in these patients.
Resumo:
Atrial fibrillation (AF) is the most common cardiac arrhythmia. The risk of thromboembolic events is important, and at that time, there is no definite treatment for AF. Oral anticoagulation also represents a hemorrhagic risk factor. Ninety percent of atrial thrombi are located within the left atrial appendage. The percutaneous closure of this left atrial appendage with a device has been shown to decrease thromboembolic events even after interruption of oral anticoagulation as compared to warfarin in a recent randomized study. Recent data support this innovative technique as a reasonable alternative to long term anticoagulation in patients at high risk of bleeding.