994 resultados para Angelucci, Liborio (17..-18..) -- Portraits
Resumo:
Poly(3,4-ethylenedioxy)thiophene (PEDOT) doped with tosylate ion (PEDOT-tosylate or VPP PEDOT) was synthesized by vapor phase polymerization (VPP) technique on glass as well as on glass/ITO and the electrochromic properties were investigated. Compared with that of PEDOT-PSS spin-coated on glass/ITO, the studies showed that VPP PEDOT has a lower work function and better electrochromic properties. The magneto and AC transport properties studies were done on VPP PEDOT coated on glass substrate. The system shows 2-dimensional variable range hopping and wave function shrinkage of charge carriers.
Resumo:
This work presents a numerical analysis of simultaneous mould filling and phase change for solidification in a two-dimensional rectangular cavity. The role of residual flow strength and temperature gradients within the solidifying domain, caused by the filling process, on the evolution of solidification interface are investigated. An implicit volume of fluid (VOF)-based algorithm has been employed for simulating the free surface flows during the filling process, while the model for solidification is based on a fixed-grid enthalpy-based control volume approach. Solidification modeling is coupled with VOF through User Defined Functions developed in the commercial computational fluid dynamics (CFD) code FLUENT 6.3.26. Comparison between results of the conventional analysis without filling effect and those of the present analysis shows that the residual flow resulting from the filling process significantly influences the progress of the solidification interface. A parametric study is also performed with variables such as cooling rate, filling velocity and filling configuration, in order to investigate the coupled effects of the buoyancy-driven flow and the residual flow on the solidification behavior.
Resumo:
The adequacy of anesthesia has been studied since the introduction of balanced general anesthesia. Commercial monitors based on electroencephalographic (EEG) signal analysis have been available for monitoring the hypnotic component of anesthesia from the beginning of the 1990s. Monitors measuring the depth of anesthesia assess the cortical function of the brain, and have gained acceptance during surgical anesthesia with most of the anesthetic agents used. However, due to frequent artifacts, they are considered unsuitable for monitoring consciousness in intensive care patients. The assessment of analgesia is one of the cornerstones of general anesthesia. Prolonged surgical stress may lead to increased morbidity and delayed postoperative recovery. However, no validated monitoring method is currently available for evaluating analgesia during general anesthesia. Awareness during anesthesia is caused by an inadequate level of hypnosis. This rare but severe complication of general anesthesia may lead to marked emotional stress and possibly posttraumatic stress disorder. In the present series of studies, the incidence of awareness and recall during outpatient anesthesia was evaluated and compared with that of in inpatient anesthesia. A total of 1500 outpatients and 2343 inpatients underwent a structured interview. Clear intraoperative recollections were rare the incidence being 0.07% in outpatients and 0.13% in inpatients. No significant differences emerged between outpatients and inpatients. However, significantly smaller doses of sevoflurane were administered to outpatients with awareness than those without recollections (p<0.05). EEG artifacts in 16 brain-dead organ donors were evaluated during organ harvest surgery in a prospective, open, nonselective study. The source of the frontotemporal biosignals in brain-dead subjects was studied, and the resistance of bispectral index (BIS) and Entropy to the signal artifacts was compared. The hypothesis was that in brain-dead subjects, most of the biosignals recorded from the forehead would consist of artifacts. The original EEG was recorded and State Entropy (SE), Response Entropy (RE), and BIS were calculated and monitored during solid organ harvest. SE differed from zero (inactive EEG) in 28%, RE in 29%, and BIS in 68% of the total recording time (p<0.0001 for all). The median values during the operation were SE 0.0, RE 0.0, and BIS 3.0. In four of the 16 organ donors, EEG was not inactive, and unphysiologically distributed, nonreactive rhythmic theta activity was present in the original EEG signal. After the results from subjects with persistent residual EEG activity were excluded, SE, RE, and BIS differed from zero in 17%, 18%, and 62% of the recorded time, respectively (p<0.0001 for all). Due to various artifacts, the highest readings in all indices were recorded without neuromuscular blockade. The main sources of artifacts were electrocauterization, electromyography (EMG), 50-Hz artifact, handling of the donor, ballistocardiography, and electrocardiography. In a prospective, randomized study of 26 patients, the ability of Surgical Stress Index (SSI) to differentiate patients with two clinically different analgesic levels during shoulder surgery was evaluated. SSI values were lower in patients with an interscalene brachial plexus block than in patients without an additional plexus block. In all patients, anesthesia was maintained with desflurane, the concentration of which was targeted to maintain SE at 50. Increased blood pressure or heart rate (HR), movement, and coughing were considered signs of intraoperative nociception and treated with alfentanil. Photoplethysmographic waveforms were collected from the contralateral arm to the operated side, and SSI was calculated offline. Two minutes after skin incision, SSI was not increased in the brachial plexus block group and was lower (38 ± 13) than in the control group (58 ± 13, p<0.005). Among the controls, one minute prior to alfentanil administration, SSI value was higher than during periods of adequate antinociception, 59 ± 11 vs. 39 ± 12 (p<0.01). The total cumulative need for alfentanil was higher in controls (2.7 ± 1.2 mg) than in the brachial plexus block group (1.6 ± 0.5 mg, p=0.008). Tetanic stimulation to the ulnar region of the hand increased SSI significantly only among patients with a brachial plexus block not covering the site of stimulation. Prognostic value of EEG-derived indices was evaluated and compared with Transcranial Doppler Ultrasonography (TCD), serum neuron-specific enolase (NSE) and S-100B after cardiac arrest. Thirty patients resuscitated from out-of-hospital arrest and treated with induced mild hypothermia for 24 h were included. Original EEG signal was recorded, and burst suppression ratio (BSR), RE, SE, and wavelet subband entropy (WSE) were calculated. Neurological outcome during the six-month period after arrest was assessed with the Glasgow-Pittsburgh Cerebral Performance Categories (CPC). Twenty patients had a CPC of 1-2, one patient had a CPC of 3, and nine patients died (CPC 5). BSR, RE, and SE differed between good (CPC 1-2) and poor (CPC 3-5) outcome groups (p=0.011, p=0.011, p=0.008, respectively) during the first 24 h after arrest. WSE was borderline higher in the good outcome group between 24 and 48 h after arrest (p=0.050). All patients with status epilepticus died, and their WSE values were lower (p=0.022). S-100B was lower in the good outcome group upon arrival at the intensive care unit (p=0.010). After hypothermia treatment, NSE and S-100B values were lower (p=0.002 for both) in the good outcome group. The pulsatile index was also lower in the good outcome group (p=0.004). In conclusion, the incidence of awareness in outpatient anesthesia did not differ from that in inpatient anesthesia. Outpatients are not at increased risk for intraoperative awareness relative to inpatients undergoing general anesthesia. SE, RE, and BIS showed non-zero values that normally indicate cortical neuronal function, but were in these subjects mostly due to artifacts after clinical brain death diagnosis. Entropy was more resistant to artifacts than BIS. During general anesthesia and surgery, SSI values were lower in patients with interscalene brachial plexus block covering the sites of nociceptive stimuli. In detecting nociceptive stimuli, SSI performed better than HR, blood pressure, or RE. BSR, RE, and SE differed between the good and poor neurological outcome groups during the first 24 h after cardiac arrest, and they may be an aid in differentiating patients with good neurological outcomes from those with poor outcomes after out-of-hospital cardiac arrest.
Resumo:
The MIT Lincoln Laboratory IDS evaluation methodology is a practical solution in terms of evaluating the performance of Intrusion Detection Systems, which has contributed tremendously to the research progress in that field. The DARPA IDS evaluation dataset has been criticized and considered by many as a very outdated dataset, unable to accommodate the latest trend in attacks. Then naturally the question arises as to whether the detection systems have improved beyond detecting these old level of attacks. If not, is it worth thinking of this dataset as obsolete? The paper presented here tries to provide supporting facts for the use of the DARPA IDS evaluation dataset. The two commonly used signature-based IDSs, Snort and Cisco IDS, and two anomaly detectors, the PHAD and the ALAD, are made use of for this evaluation purpose and the results support the usefulness of DARPA dataset for IDS evaluation.
Resumo:
Ionic conductivity and other physico-chemical properties of a soft matter composite electrolyte comprising of a polymer-sodium salt complex and a non-ionic plastic crystal are discussed here. The electrolyte under discussion comprises of polyethyleneoxide (PEO)-sodium triflate (NaCF3SO3) and succinonitrile (SN). Addition of SN to PEO-NaCF3SO3 resulted in significant enhancement in ionic conductivity. At 50% SN concentration (with respect to weight of polymer), the polymer-plastic composite electrolyte room temperature (= 25 degrees C) ionic conductivity was similar to 1.1 x 10(-4) Omega(-1) cm(-1), approximately 45 times higher than PEO-NaCF3SO3. Observations from ac-impedance spectroscopy along with X-ray diffraction, differential scanning calorimetry and Fourier transform inrared spectroscopy strongly suggest the enhancement in the composite is ionicconductivity due to enhanced ion mobility via decrease in crystallinity of PEO. The free standing composite polymer-plastic electrolytes were more compliable than PEO-NaCF3SO3 thus exhibiting no detrimental effects of succinonitrile addition on the mechanical stability of PEO-NaCF3SO3. We propose that the exploratory PEO-NaCF3SO3-SN system.discussed here will eventually be developed as a prototype electrolyte.for sodium-sulfur batteries capable of operating at ambient and.sub-ambient conditions. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Polymorphic forms of the DNA duplex with long stretches of structural monotony are known. Several alternating purine-pyrimidine sequences have been shown to adopt left-handed Z-conformation. We report a DNA sequence d(CGCGCGATCGAT)n exhibiting alternating right-handed B and left-handed Z helical conformation after every half a turn. Further, this unusual conformation with change in handedness after every six base pairs was induced at physiological superhelical density.
Resumo:
The free-base, copper(II) and zinc(II) derivatives of 5,10,15,20-tetraarylporphyrin (aryl = phenyl, 4-methylphenyl or 4-chlorophenyl) and the corresponding brominated 2,3,7,8,12,13,17,18-octabromo-5,10,15,20-tetraarylporphyrin derivatives have been synthesized and their spectral and redox properties compared by UV/VIS, H-1 NMR, ESR and cyclic voltammetric methods. Substitution with the electron-withdrawing bromine groups at the pyrrole carbons has a profound influence on the UV/VIS and H-1 NMR spectral features and also on the redox potentials of these systems. On the other hand, electron-withdrawing chloro or electron-donating methyl groups at the para positions of the four phenyl rings have only a marginal effect on the spectra and redox potentials of both the brominated and the non-brominated derivatives. The ESR data for the copper(II) derivatives of ail these systems reveal that substitution at either the beta-pyrrole carbons and/or the para positions of the meso-phenyl groups does not significantly affect the spin-Hamiltonian parameters that describe the metal centre in each case. Collectively, these observations suggest that the highest-occupied (HOMO) and lowest-unoccupied molecular orbitals (LUMO) of the octabromoporphyrins involve the porphyrin pi-ring system as is the case with the non-brominated derivatives.-Investigations have been carried out to probe the electronic structures of these systems by three different approaches involving spectral and redox potential data as well as AMI calculations. The results obtained suggest that the electron-withdrawing beta-bromine substituents stabilize the LUMOs and, to a lesser degree, the HOMOs and that the extent of these changes can be fine-tuned, in a subtle way, by substituting at the meso-aryl rings of a given porphyrin.
Resumo:
We present a method to statically balance a general treestructured,planar revolute-joint linkage loaded with linear springs or constant forces without using auxiliary links. The balancing methods currently documented in the literature use extra links; some do not apply when there are spring loads and some are restricted to only two-link serial chains. In our method, we suitably combine any non-zero-free-length load spring with another spring to result in an effective zero-free-length spring load. If a link has a single joint (with the parent link), we give a procedure to attach extra zero-free-length springs to it so that forces and moments are balanced for the link. Another consequence of this attachment is that the constraint force of the joint on the parent link becomes equivalent to a zero-free-length spring load. Hence, conceptually,for the parent link, the joint with its child is removed and replaced with the zero-free-length spring. This feature allows recursive application of this procedure from the end-branches of the tree down to the root, satisfying force and moment balance of all the links in the process. Furthermore, this method can easily be extended to the closed-loop revolute-joint linkages, which is also illustrated in the paper.
Resumo:
This paper presents concepts, designs, and working prototypes of enhanced laparoscopic surgical tools. The enhancements are in equipping the tool with force and temperature sensing as well as image acquisition for stereo vision. Just as the pupils of our eyes are adequately spaced out and the distance between them is adjustable, two minute cameras mounted on a mechanism in our design can be moved closer or farther apart inside the inflated abdomen during the surgery. The cameras are fitted to a deployable mechanism consisting of flexural joints so that they can be inserted through a small incision and then deployed and moved as needed.A temperature sensor and a force sensor are mounted on either of the gripping faces of the surgical grasping tool to measure the temperature and gripping force, which need to be controlled for safe laparoscopic surgery. The sensors are small enough and hence they do not cause interference during surgery and insertion.Prototyping and working of the enhanced laparoscopic tool are presented with details
Resumo:
An external pipe-crawling device presented in this paper aids the inspection of pipes in hazardous environments and areas inaccessible to humans. The principal component of our design, which uses inchworm type motion, is a compliant ring mechanism actuated using shape memory alloy (SMA) wire. It was fabricated and tested and was reported in our earlier work. But this device had a drawback of low crawling speed (about 1 mm/min) owing to the delay in heating and cooling of the SMA strips in the linear actuation. Additionally, that design also had the difficulties of mounting on pipes with closed ends, large radial span, and the need for housing for electrical insulation and guiding of the SMA wire. In this paper we present a compact design that overcomes the difficulties of the earlier design. In particular, we present a compact compliant mechanism with two halves so as to enable mounting and un-mounting on any closed or open pipe. Another feature is the presence of insulation and guiding of the SMA wire without housing. This design results in a reduction of the radial span of the ring from 22 mm to 12 mm, and the stiffness of the mechanism and the SMA wire are matched. An SMA helical spring is to used in the place of an SMA strip to increase the crawling speed of the device. A microcontroller-based circuitry is also fitted to cyclically.activate the SMA wires and springs.
Resumo:
We present the concept, prototypes, and an optimal design method for a compliant mechanism kit as a parallel to the kits available for rigid-body mechanisms. The kit consists of flexible beams and connectors that can be easily hand-assembled using snap fits. It enables users, using their creativity and mechanics intuition, to quickly realize a compliant mechanism. The mechanisms assembled in this manner accurately capture the essential behavior of the topology, shape, size and material aspects and thereby can lead the way for a real compliant mechanism for practical use. Also described in this paper are the design of the connector to which flexible beams can be added in eight different directions; and prototyping of the spring steel connectors as well as beams using wire-cut electro discharge machining. It is noted in this paper that the concept of the kit also resolves a discrepancy in the finite element (FE) modeling of beam-based compliant mechanisms. The discrepancy arises when two or more beams are joining at one point and thus leading to increased stiffness. After resolving this discrepancy, this work extends the topology optimization to automatically generate designs that can be assembled with the kit. Thus, the kit and the accompanying analysis and optimal synthesis procedures comprise a self-contained educational as well as a research and pragmatic toolset for compliant mechanisms. The paper also illustrates how human creativity finds new ways of using the kit beyond the original intended use and how it is useful even for a novice to design compliant mechanisms.
Resumo:
We present a real-time haptics-aided injection technique for biological cells using miniature compliant mechanisms. Our system consists of a haptic robot operated by a human hand, an XYZ stage for micro-positioning, a camera for image capture, and a polydimethylsiloxane (PDMS) miniature compliant device that serves the dual purpose of an injecting tool and a force-sensor. In contrast to existing haptics-based micromanipulation techniques where an external force sensor is used, we use visually captured displacements of the compliant mechanism to compute the applied and reaction forces. The human hand can feel the magnified manipulation force through the haptic device in real-time while the motion of the human hand is replicated on the mechanism side. The images are captured using a camera at the rate of 30 frames per second for extracting the displacement data. This is used to compute the forces at the rate of 30 Hz. The force computed in this manner is sent at the rate of 1000 Hz to ensure stable haptic interaction. The haptic cell-manipulation system was tested by injecting into a zebrafish egg cell after validating the technique at a size larger than that of the cell.