991 resultados para Analytical Spectral Devices (ASD), FieldSpec Pro


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The dataset consists of spectra and photogrpahs of the surface (sea ice and melt ponds) obtained in the Central Arctic during the Polarstern cruise ARK-XXVII/3 at 6 ice stations. The spectra were measured with a portable spectroradiometer ASD FieldSpecPro 3. The photographs were taken with a digital camera Olympus C765 in the "Auto" mode. The measurements have been performed every 10 meters along 100 m ROV transects (transects used for underice ROV flights) where available. Otherwise the albedo measurements have been done at the selected cites complementary to point transmitance measurements or at cites featuring characteristic sea ice surface.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In recent years modern numerical methods have been employed in the design of Wave Energy Converters (WECs), however the high computational costs associated with their use makes it prohibitive to undertake simulations involving statistically relevant numbers of wave cycles. Experimental tests in wave tanks could also be performed more efficiently and economically if short time traces, consisting of only a few wave cycles, could be used to evaluate the hydrodynamic characteristics of a particular device or design modification. Ideally, accurate estimations of device performance could be made utilizing results obtained from investigations with a relatively small number of wave cycles. However the difficulty here is that many WECs, such as the Oscillating Wave Surge Converter (OWSC), exhibit significant non-linearity in their response. Thus it is challenging to make accurate predictions of annual energy yield for a given spectral sea state using short duration realisations of that sea. This is because the non-linear device response to particular phase couplings of sinusoidal components within those time traces might influence the estimate of mean power capture obtained. As a result it is generally accepted that the most appropriate estimate of mean power capture for a sea state be obtained over many hundreds (or thousands) of wave cycles. This ensures that the potential influence of phase locking is negligible in comparison to the predictions made. In this paper, potential methods of providing reasonable estimates of relative variations in device performance using short duration sea states are introduced. The aim of the work is to establish the shortness of sea state required to provide statistically significant estimations of the mean power capture of a particular type of Wave Energy Converter. The results show that carefully selected wave traces can be used to reliably assess variations in power output due to changes in the hydrodynamic design or wave climate. 

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report on the experimental characterisation of laser-driven ion beams using a Thomson Parabola Spectrometer (TPS) equipped with trapezoidally shaped electric plates, proposed by Gwynne et al. [Rev. Sci. Instrum. 85, 033304 (2014)]. While a pair of extended (30 cm long) electric plates was able to produce a significant increase in the separation between neighbouring ion species at high energies, deploying a trapezoidal design circumvented the spectral clipping at the low energy end of the ion spectra. The shape of the electric plate was chosen carefully considering, for the given spectrometer configuration, the range of detectable ion energies and species. Analytical tracing of the ion parabolas matches closely with the experimental data, which suggests a minimal effect of fringe fields on the escaping ions close to the wedged edge of the electrode. The analytical formulae were derived considering the relativistic correction required for the high energy ions to be characterised using such spectrometer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Among various optical sensing schemes, infrared spectroscopy is a powerful tool for detecting and determining the composition of complex organic samples since vibrational finger prints of all biomolecules and organic species are located in this window. This spectroscopic technique is simple, reliable, fast, non-destructive, cost-effective while having low sensitivity. Use of metallic nanoparticles in association with a good IR transparent sensing substrate, is one of the promising solutions to enhance the sensitivity. Chalcogenide glasses are promising substrate material because of their extended optical transmission window starting from the visible to the far infrared range up to 20 μm, high refractive index usually between 2 and 3 and high optical nonlinearity, which make them good candidates as IR sensors and optical ultrafast nonlinear devices. These glasses are favorable sensor materials for the infrared spectral range because of their high IR transparency to allow for low optical loss at wavelengths corresponding to the characteristic optical absorption bands of organic molecules, high refractive index for tight confinement of optical energy within the resonator structure, processibility into thin film form, chemical compatibility for adhesion of silver nano particles and thin films and resistance to the chemical environment to be sensed. Molecules adsorbed to silver island structures shows enhanced IR absorption spectra and the extent of enhancement is determined by many factors such as the size, density and morphology of silver structures, optical and dielectric properties of the substrate material etc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We evaluate whether society can adequately be conceptualized as a component of social-ecological systems, given social theory and the current outputs of systems-based research. A mounting critique from the social sciences posits that resilience theory has undertheorized social entities with the concept of social-ecological systems. We trace the way that use of the term has evolved, relating to social science theory. Scientometic and network analysis provide a wide range of empirical data about the origin, growth, and use of this term in academic literature. A content analysis of papers in Ecology and Society demonstrates a marked emphasis in research on institutions, economic incentives, land use, population, social networks, and social learning. These findings are supported by a review of systems science in 18 coastal assessments. This reveals that a systems-based conceptualization tends to limit the kinds of social science research favoring quantitative couplings of social and ecological components and downplaying interpretive traditions of social research. However, the concept of social-ecological systems remains relevant because of the central insights concerning the dynamic coupling between humans and the environment, and its salient critique about the need for multidisciplinary approaches to solve real world problems, drawing on heuristic devices. The findings of this study should lead to more circumspection about whether a systems approach warrants such claims to comprehensiveness. Further methodological advances are required for interdisciplinarity. Yet there is evidence that systems approaches remain highly productive and useful for considering certain social components such as land use and hybrid ecological networks. We clarify advantages and restrictions of utilizing such a concept, and propose a reformulation that supports engagement with wider traditions of research in the social sciences.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper reports the thermomechanical sensitivity of bimaterial cantilevers over a mid-infrared (IR) spectral range (5-10 µm) that is critical both for chemical analysis via vibrational spectroscopy and for direct thermal detection in the 300-700 K range. Mechanical bending sensitivity and noise were measured and modeled for six commercially available microcantilevers, which consist of either an aluminum film on a silicon cantilever or a gold film on a silicon nitride cantilever. The spectral sensitivity of each cantilever was determined by recording cantilever deflection when illuminated with IR light from a monochromator. Rigorous modeling and systematic characterization of the optical system allowed for a quantitative estimate of IR energy incident upon the cantilever. Separately, spectral absorptance of the cantilever was measured using Fourier transform infrared (FT-IR) microscopy, which was compared with analytical models of radiation onto the cantilever and heat flow within the cantilever. The predictions of microcantilever thermomechanical bending sensitivity and noise agree well with measurements, resulting in a ranking of these cantilevers for their potential use in IR measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this thesis was to examine the role of environmental sustainability in the procurement of medical devices in health care sector. Current literature is mainly focused on other product groups and medical devices have been left without sufficient attention. Nevertheless, EU has recently developed green public procurement criteria for medical devices (EU GPP criteria for health care EEE) in order to support and offer guidelines for purchasers in hospitals. In this study, the criteria were used as a framework in order to examine the most significant environmental aspects for medical devices. The empirical research was executed in Finnish public hospitals with mixed method approach; quantitative data was collected by a survey and qualitative data was collected by interviews held for procurement specialists. The focus was on understanding the importance of environmental sustainability in the procurement of medical devices and which environmentally sustainable features would be the most significant. Of interest was also the medical device supplier view and how they could take environmental sustainability into consideration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Charge carrier lifetime measurements in bulk or unfinished photovoltaic (PV) materials allow for a more accurate estimate of power conversion efficiency in completed solar cells. In this work, carrier lifetimes in PV- grade silicon wafers are obtained by way of quasi-steady state photoconductance measurements. These measurements use a contactless RF system coupled with varying narrow spectrum input LEDs, ranging in wavelength from 460 nm to 1030 nm. Spectral dependent lifetime measurements allow for determination of bulk and surface properties of the material, including the intrinsic bulk lifetime and the surface recombination velocity. The effective lifetimes are fit to an analytical physics-based model to determine the desired parameters. Passivated and non-passivated samples are both studied and are shown to have good agreement with the theoretical model.