923 resultados para Amphibole (Intensity, 8.45Å)


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Dunite and gabbroic materials recovered from Hole 1271B, Ocean Drilling Program (ODP) Leg 209, were examined for mineral chemistry to understand melt flow and melt-mantle reactions in the shallowest upper mantle of the Mid-Atlantic Ridge near the 15°20' Fracture Zone. Hole 1271B was drilled to 103.8 meters below seafloor on the inner corner high along the south wall of the 15°20' Fracture Zone. The total length of core collected was 15.9 m (recovery = ~15%). The dominant rock type in Hole 1271B is dunite, followed by brown amphibole gabbro, olivine gabbro, and troctolite, along with minor amounts of harzburgite and olivine gabbronorite. A large proportion of the dunite is associated with gabbroic rocks in Hole 1271B, similar to those observed in the Mohorovicic (Moho) transition zone of the Oman ophiolite, indicating significant magmatic activity in this region near the 15°20' Fracture Zone. Olivine Fo content varies from 89.2 to 91.2 in impregnated dunite and from 85.6 to 88.6 in troctolite, olivine gabbro, and olivine gabbronorite. Spinel Cr# (= 100 x Cr/[Cr + Al] molar ratio) ranges from 38.9 to 62.7 in dunite and from 46.3 to 57.6 in troctolites, olivine gabbro, and olivine gabbronorite. Compositional trends for spinel from dunite through troctolite toward olivine gabbro/gabbronorite are characterized by increases in TiO2, Cr#, and Fe3+#, very similar to those reported from Hess Deep Site 895. Olivine gabbro, olivine gabbronorite, and troctolite in Hole 1271B are considered to have formed as hybrid rocks between dunite and an evolved melt in the walls of a melt channel in the shallowest upper mantle that is tens of meters wide. The melt trapped in the wall rock crystallized plagioclase and clinopyroxene. On the other hand, dunite in the center of the melt channel became more refractory by melt-mantle reactions, increasing spinel Cr# to 62.5.

Relevância:

40.00% 40.00%

Publicador:

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We experimentally demonstrated a highly sensitive twist sensor system based on a 45° and an 81° tilted fibre grating (TFG). The 81°-TFG has a set of dual-peaks that are due to the birefringence induced by its extremely tilted structure. When the 81°-TFG subjected to twist, the coupling to the two peaks would interchange from each other, providing a mechanism to measure and monitor the twist. We have investigated the performance of the sensor system by three interrogation methods (spectral, power-measurement and voltage-measurement). The experimental results clearly show that the 81°-TFG and the 45°-TFG could be combined forming a full fibre twist sensor system capable of not just measuring the magnitude but also recognising the direction of the applied twist.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Although numerous studies and metanalysis have shown the beneficial effect of statin therapy in CVD secondary prevention, there is still controversy such the use of statins for primary CVD prevention in patients with DM. The purpose of this study was to evaluate the occurrence of total major adverse cardio-vascular events (MACE) in a cohort of patients with type 2 diabetes complicated by nephropathy treated with statins, in order to verify real life effect of statin on CVD primary prevention. Methods: We conducted an observational prospective multicenter study on 564 patients with type 2 diabetic nephropathy free of cardiovascular disease attending 21 national outpatient diabetes clinics and followed them up for 8 years. 169 of them were treated with statins (group A) while 395 were not on statins (group B). Results: Notably, none of the patients was treated with a high-intensity statin therapy according to last ADA position statement. Total MACE occurred in 32 patients from group A and in 68 patients from group B. Fatal MACE occurred in 13 patients from group A and in 30 from group B; nonfatal MACE occurred in 19 patients from group A and in 38 patients from group B. The analysis of the Kaplan-Meier survival curves showed a not statistically significant difference in the incidence of total (p 0.758), fatal (p 0.474) and nonfatal (p 0.812) MACE between the two groups. HbA1c only showed a significant difference in the incidence of MACE between the two groups (HR 1.201, CI 1.041-1.387, p 0.012). Conclusions: These findings suggest that, in a real clinical setting, moderate-intensity statin treatment is ineffective in cardiovascular primary prevention for patients with diabetic nephropathy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: In the majority of exercise intervention studies, the aggregate reported weight loss is often small. The efficacy of exercise as a weight loss tool remains in question. The aim of the present study was to investigate the variability in appetite and body weight when participants engaged in a supervised and monitored exercise programme. ---------- Design: Fifty-eight obese men and women (BMI = 31·8 ± 4·5 kg/m2) were prescribed exercise to expend approximately 2092 kJ (500 kcal) per session, five times a week at an intensity of 70 % maximum heart rate for 12 weeks under supervised conditions in the research unit. Body weight and composition, total daily energy intake and various health markers were measured at weeks 0, 4, 8 and 12. ---------- Results: Mean reduction in body weight (3·2 ± 1·98 kg) was significant (P < 0·001); however, there was large individual variability (−14·7 to +2·7 kg). This large variability could be largely attributed to the differences in energy intake over the 12-week intervention. Those participants who failed to lose meaningful weight increased their food intake and reduced intake of fruits and vegetables. ---------- Conclusion: These data have demonstrated that even when exercise energy expenditure is high, a healthy diet is still required for weight loss to occur in many people.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To examine the influence of two different fast-start pacing strategies on performance and oxygen consumption (V˙O2) during cycle ergometer time trials lasting ∼5 min. Methods: Eight trained male cyclists performed four cycle ergometer time trials whereby the total work completed (113 ± 11.5 kJ; mean ± SD) was identical to the better of two 5-min self-paced familiarization trials. During the performance trials, initial power output was manipulated to induce either an all-out or a fast start. Power output during the first 60 s of the fast-start trial was maintained at 471.0 ± 48.0 W, whereas the all-out start approximated a maximal starting effort for the first 15 s (mean power: 753.6 ± 76.5 W) followed by 45 s at a constant power output (376.8 ± 38.5 W). Irrespective of starting strategy, power output was controlled so that participants would complete the first quarter of the trial (28.3 ± 2.9 kJ) in 60 s. Participants performed two trials using each condition, with their fastest time trial compared. Results: Performance time was significantly faster when cyclists adopted the all-out start (4 min 48 s ± 8 s) compared with the fast start (4 min 51 s ± 8 s; P < 0.05). The first-quarter V˙O2 during the all-out start trial (3.4 ± 0.4 L·min-1) was significantly higher than during the fast-start trial (3.1 ± 0.4 L·min-1; P < 0.05). After removal of an outlier, the percentage increase in first-quarter V˙O2 was significantly correlated (r = -0.86, P < 0.05) with the relative difference in finishing time. Conclusions: An all-out start produces superior middle distance cycling performance when compared with a fast start. The improvement in performance may be due to a faster V˙O2 response rather than time saved due to a rapid acceleration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background The preservation of meniscal tissue is important to protect joint surfaces. Purpose We have an aggressive approach to meniscal repair, including repairing tears other than those classically suited to repair. Here we present the medium- to long-term outcome of meniscal repair (inside-out) in elite athletes. Study Design Case series; Level of evidence, 4. Methods Forty-two elite athletes underwent 45 meniscal repairs. All repairs were performed using an arthroscopically assisted inside-out technique. Eighty-three percent of these athletes had ACL reconstruction at the same time. Patients returned a completed questionnaire (including Lysholm and International Knee Documentation Committee [IKDC] scores). Mean follow-up was 8.5 years. Failure was defined by patients developing symptoms of joint line pain and/or locking or swelling requiring repeat arthroscopy and partial meniscectomy. Results The average Lysholm and subjective IKDC scores were 89.6 and 85.4, respectively. Eighty-one percent of patients returned to their main sport and most to a similar level at a mean time of 10.4 months after repair, reflecting the high level of ACL reconstruction in this group. We identified 11 definite failures, 10 medial and 1 lateral meniscus, that required excision; this represents a 24% failure rate. We identified 1 further patient who had possible failed repairs, giving a worst-case failure rate of 26.7% at a mean of 42 months after surgery. However, 7 of these failures were associated with a further injury. Therefore, the atraumatic failure rate was 11%. Age and size and location of the tears were not associated with a higher failure rate. Medial meniscal repairs were significantly more likely to fail than lateral meniscal repairs, with a failure rate of 36.4% and 5.6%, respectively (P < .05). Conclusion Meniscal repair and healing are possible, and most elite athletes can return to their preinjury level of activity.