974 resultados para Abdominal Aortic Aneurism


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of the present research was to investigate the ultrastructural peculiarities of the aortic wall of the rat. Seven young adult rats were used, from which fragments of the infrarenal abdominal aorta were collected. After collection, the vascular segments were fixed and sent for analysis by scanning electron microscope. The elastic lamellae appear interposed with smooth muscular fibers; this pattern was verified mainly at the medial layer structure. Among the mural elements a well defined interrelationship was established through connective lamellae of the arterial wall. The collagen lamellae mainly provided anchoring among the elastic and smooth muscular constituents. The intimal layer showed special ultrastructural features, such as a non-continuous inner elastic lamina presented in certain sites of the vascular wall, followed by endothelial pores. This mural pattern of the abdominal aorta provided support to vascular functions such as shrinkage among the laminar composition of the arterial layers, also acting in mechanical properties of the vascular wall, such as viscoelasticity and contractility - essential actions to blood vessel hemodynamics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Smoking is the most relevant environmental factor that affects the development of aortic aneurysm. Smokers have elevated levels of elastase activity in the arterial wall, which leads to weakening of the aorta. The aim of this study was to verify whether cigarette smoke exposure itself is capable of altering the aortic wall. Methods: Forty-eight Wistar rats were divided into 2-, 4-, and 6-month experimental periods and into 2 groups: smokers (submitted to smoke exposure at a rate of 40 cigarettes/day) and nonsmokers. At the end of the experimental periods, the aortas were removed and cross-sectioned to obtain histologic specimens for light microscopic and morphometric analyses. The remaining longitudinal segments were stretched to rupture and mechanical parameters were determined. Results: A degenerative process (i.e., a reduction in elastic fibers, the loss of lamellar arrangement, and a reduction of smooth muscle cells) was observed, and this effect was proportional in intensity to the period of tobacco exposure. We observed a progressive reduction in the yield point of the thoracic aorta over time (P < 0.05). There was a decrease in stiffness (P < 0.05) and in failure load (P < 0.05) at 6 months in the abdominal aorta of rats in the smoking group. Conclusions: Chronic exposure to tobacco smoke can affect the mechanical properties of the aorta and can also provoke substantial structural changes of the arterial wall. © 2013 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Smoking is the most relevant environmental factor that affects the development of aortic aneurysm. Smokers have elevated levels of elastase activity in the arterial wall, which leads to weakening of the aorta. The aim of this study was to verify whether cigarette smoke exposure itself is capable of altering the aortic wall. Methods: Forty-eight Wistar rats were divided into 2-, 4-, and 6-month experimental periods and into 2 groups: smokers (submitted to smoke exposure at a rate of 40 cigarettes/day) and nonsmokers. At the end of the experimental periods, the aortas were removed and crosssectioned to obtain histologic specimens for light microscopic and morphometric analyses. The remaining longitudinal segments were stretched to rupture and mechanical parameters were determined. Results: A degenerative process (i.e., a reduction in elastic fibers, the loss of lamellar arrangement, and a reduction of smooth muscle cells) was observed, and this effect was proportional in intensity to the period of tobacco exposure. We observed a progressive reduction in the yield point of the thoracic aorta over time (P < 0.05). There was a decrease in stiffness (P < 0.05) and in failure load (P < 0.05) at 6 months in the abdominal aorta of rats in the smoking group. Conclusions: Chronic exposure to tobacco smoke can affect the mechanical properties of the aorta and can also provoke substantial structural changes of the arterial wall

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aortic aneurysms and aortic dissection represent a significant health risk due to the demographic developments and current life styles. The mortality of ruptured aortic aneurysms is up to 80 % and the prevalence of aneurysms varies depending on the localization (thoracic or abdominal). Most commonly affected is the infrarenal abdominal aorta; however, there is evidence that the prevalence is diminishing but in contrast the incidence of thoracic aortic aneurysms is increasing. Aortic dissection is often fatal and is the most common acute aortic disease but the incidence is presumed to be underestimated. The pathogenesis of aortic aneurysms is manifold and is based on an interplay between degenerative, proteolytic and inflammatory processes. An aortic dissection arises from a tear in the intima which results in a separation of the aortic wall layers with infiltration of bleeding and the danger of aortic rupture. Various genetic disorders of connective tissue promote degeneration of the aortic media, most notably Marfan syndrome. Risk factors for aortic aneurysms and aortic dissection are nicotine abuse, arterial hypertension, age and male gender. Aortic aneurysms initially have an uneventful course and as a consequence are mostly discovered incidentally. The clinical course and symptoms of aortic dissection are very much dependent on the section of the aorta affected and the manifestations are manifold. Acute aortic dissection is in 80 % of cases first manifested as sudden extremely severe pain. The diagnostics and subsequent course control can be achieved by a variety of imaging procedures but the modality of choice is computed tomography.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: The aim of this study was to measure the radiation dose of dual-energy and single-energy multidetector computed tomographic (CT) imaging using adult liver, renal, and aortic imaging protocols. MATERIALS AND METHODS: Dual-energy CT (DECT) imaging was performed on a conventional 64-detector CT scanner using a software upgrade (Volume Dual Energy) at tube voltages of 140 and 80 kVp (with tube currents of 385 and 675 mA, respectively), with a 0.8-second gantry revolution time in axial mode. Parameters for single-energy CT (SECT) imaging were a tube voltage of 140 kVp, a tube current of 385 mA, a 0.5-second gantry revolution time, helical mode, and pitch of 1.375:1. The volume CT dose index (CTDI(vol)) value displayed on the console for each scan was recorded. Organ doses were measured using metal oxide semiconductor field-effect transistor technology. Effective dose was calculated as the sum of 20 organ doses multiplied by a weighting factor found in International Commission on Radiological Protection Publication 60. Radiation dose saving with virtual noncontrast imaging reconstruction was also determined. RESULTS: The CTDI(vol) values were 49.4 mGy for DECT imaging and 16.2 mGy for SECT imaging. Effective dose ranged from 22.5 to 36.4 mSv for DECT imaging and from 9.4 to 13.8 mSv for SECT imaging. Virtual noncontrast imaging reconstruction reduced the total effective dose of multiphase DECT imaging by 19% to 28%. CONCLUSION: Using the current Volume Dual Energy software, radiation doses with DECT imaging were higher than those with SECT imaging. Substantial radiation dose savings are possible with DECT imaging if virtual noncontrast imaging reconstruction replaces precontrast imaging.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation (TAVI) is a disruptive technology as it satisfies a previously unmet need which is associated with a profound therapeutic benefit. In randomized clinical trials, TAVI has been shown to improve survival compared with medical treatment among patients considered not suitable candidates for surgical aortic valve replacement (SAVR), and to provide similar outcomes as SAVR in selected high-risk patients. Currently, TAVI is limited to selected elderly patients with symptomatic severe aortic stenosis. As this patient population frequently suffers from comorbid conditions, which may influence outcomes, the selection of patients to undergo TAVI underlies a complex decision process. Several clinical risk score algorithms are routinely used, although they fall short to fully appreciate the true risk among patients currently referred for TAVI. Beyond traditional risk scores, the clinical assessment by an interdisciplinary Heart Team as well as detailed imaging of the aortic valve, aortic root, descending and abdominal aorta as well as peripheral vasculature are important prerequisites to plan a successful procedure. This review will familiarize the reader with the concepts of the interdisciplinary Heart team, risk scores as well as the most important imaging algorithms suited to select appropriate TAVI patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION Endograft deployment is a well-known cause of arterial stiffness increase as well as arterial stiffness increase represent a recognized cardiovascular risk factor. A harmful effect on cardiac function induced by the endograft deployment should be investigated. Aim of this study was to evaluate the impact of endograft deployment on the arterial stiffness and cardiac geometry of patients treated for aortic aneurysm in order to detect modifications that could justify an increased cardiac mortality at follow-up. MATHERIALS AND METHODS Over a period of 3 years, patients undergoing elective EVAR for infrarenal aortic pathologies in two university centers in Emilia Romagna were examined. All patients underwent pre-operative and six-months post-operative Pulse Wave Velocity (PWV) examination using an ultrasound-based method performed by vascular surgeons together with trans-thoracic echocardiography examination in order to evaluate cardiac chambers geometry before and after the treatment. RESULTS 69 patients were enrolled. After 36 months, 36 patients (52%) completed the 6 months follow-up examination.The ultrasound-based carotid-femoral PWV measurements performed preoperatively and 6 months after the procedure revealed a significant postoperative increase of cf-PWV (11,6±3,6 m/sec vs 12,3±8 m/sec; p.value:0,037).Postoperative LVtdV (90±28,3 ml/m2 vs 99,1±29,7 ml/m2; p.value:0.031) LVtdVi (47,4±15,9 ml/m2 vs 51,9±14,9 ml/m2; p.value:0.050), IVStd (12±1,5 mm vs 12,1±1,3 mm; p.value:0,027) were significantly increased if compared with preoperative measures.Postoperative E/A (0,76±0,26 vs 0,6±0,67; p.value:0,011), E’ lateral (9,5±2,6 vs 7,9±2,6; p.value:0,024) and A’ septal (10,8±1,5 vs 8,9±2; p.value0,005) were significantly reduced if compared with preoperative measurements CONCLUSION The endovascular treatment of the abdominal aorta causes an immediate and significant increase of the aortic stiffness.This increase reflects negatively on patients’ cardiac geometry inducing left ventricle hypertrophy and mild diastolic disfunction after just 6 months from endograft’s implantation.Further investigations and long-term results are necessary to access if this negative remodeling could affect the cardiac outcome of patient treated using the endovascular approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Ruthenium (Ru) tetraamines are being increasingly used as nitric oxide (NO) carriers. In this context, pharmacological studies have become highly relevant to better understand the mechanism of action involved. Objective: To evaluate the vascular response of the tetraamines trans-[RuII(NH3)4(Py)(NO)]3+, trans-[RuII(Cl)(NO) (cyclan)](PF6)2, and trans-[RuII(NH3)4(4-acPy)(NO)]3+. Methods: Aortic rings were contracted with noradrenaline (10-6 M). After voltage stabilization, a single concentration (10-6 M) of the compounds was added to the assay medium. The responses were recorded during 120 min. Vascular integrity was assessed functionally using acetylcholine at 10-6 M and sodium nitroprusside at 10-6 M as well as by histological examination. Results: Histological analysis confirmed the presence or absence of endothelial cells in those tissues. All tetraamine complexes altered the contractile response induced by norepinephrine, resulting in increased tone followed by relaxation. In rings with endothelium, the inhibition of endothelial NO caused a reduction of the contractile effect caused by pyridine NO. No significant responses were observed in rings with endothelium after treatment with cyclan NO. In contrast, in rings without endothelium, the inhibition of guanylate cyclase significantly reduced the contractile response caused by the pyridine NO and cyclan NO complexes, and both complexes caused a relaxing effect. Conclusion: The results indicate that the vascular effect of the evaluated complexes involved a decrease in the vascular tone induced by norepinephrine (10-6 M) at the end of the incubation period in aortic rings with and without endothelium, indicating the slow release of NO from these complexes and suggesting that the ligands promoted chemical stability to the molecule. Moreover, we demonstrated that the association of Ru with NO is more stable when the ligands pyridine and cyclan are used in the formulation of the compound.Fundamento: As tetra-aminas de rutênio cada vez mais se destacam como carreadoras da molécula de óxido nítrico. Desse modo, estudos farmacológicos tornam-se altamente relevantes, afim de melhor compreender o mecanismo de ação envolvido. Objetivo: Avaliar a resposta vascular das tetra-aminas trans-[RuII(NH3)4(Py)(NO)]3+, trans-[RuII(Cl)(NO)(Cyclan)](PF6)2 e trans-[RuII(NH3)4(4-acPy)(NO)]3+. Métodos: Anéis de aorta foram pré-contraídos com noradrenalina (10-6M). Após estabilização da tensão, concentração única (10-6M) dos compostos foi adicionada ao banho de incubação. As respostas foram registradas ao longo de 120 minutos. A integridade vascular foi avaliada funcionalmente (acetilcolina 10-6M; nitroprussiato de sódio 10-6M) e histologicamente Resultados: A análise histológica confirmou a presença ou não de células endoteliais nos tecidos analisados. Todos os complexos alteraram a resposta contrátil induzida pela noradrenalina, resultando em aumento de tônus seguido de efeito relaxante. Em anéis com endotélio, a inibição do óxido nítrico endotelial causou redução do efeito contrátil da piridina óxido nítrico. Não foram observadas respostas significativas em anéis com endotélio referente ao composto cyclan óxido nítrico. Por outro lado, em anéis sem endotélio, a inibição da guanilato ciclase reduziu significativamente a resposta contrátil dos complexos piridina óxido nítrico e cyclan óxido nítrico, levando ambos os compostos a um efeito relaxante. Conclusão: Os resultados obtidos demonstram que o efeito vascular dos complexos avaliados apresentaram diminuição no tônus vascular induzido pela noradrenalina (10-6M) ao final do tempo de incubação, em anéis com e sem endotélio, indicando liberação lenta da molécula de óxido nítrico do composto estudado e sugerindo que os ligantes causaram estabilidade química à molécula. Demonstramos que a ligação rutênio óxido nítrico é mais estável quando utilizamos os ligantes piridina e cyclan para a formulação do composto.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdution: The transcatheter aortic valve implantation in the treatment of high-risk symptomatic aortic stenosis has increased the number of implants every year. The learning curve for transcatheter aortic valve implantation has improved since the last 12 years, allowing access alternatives. The aim of this study is to approach the implantation of transcatheter aortic valve through transaortic via associated with off-pump cardiopulmonary bypass surgery in a 67-year-old man, with chronic obstructive pulmonary disease, arterial hypertension and kidney transplant. Off-pump coronary artery bypass surgery was performed and the valve in the aortic position was released successfully. There were no complications in the intraoperative and postoperative period. Gradient reduction, effective orifice increasing of the prosthesis and absence of valvular regurgitation after implantation were observed by transesophageal echocardiography. Procedural success demonstrates that implantation of transcatheter aortic valve through the ascending aorta associated with coronary artery bypass surgery without CPB is a new option for these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar as características demográficas e de imagens da trombose endoluminal em uma série de pacientes submetidos a tratamento endovascular do aneurisma de aorta abdominal (TEAAA). MÉTODOS: Avaliamos as características de imagem que permitiram o diagnóstico da trombose endoluminal em uma série de 30 pacientes submetidos ao TEAAA, com seguimento de 5 a 29 meses, através de exames de tomografia computadorizada multidetectores (TCMD) de 64 canais. RESULTADOS: Foram diagnosticados dez casos de trombose luminal (33,3%), sendo que em três pacientes a trombose foi total de um ramo ilíaco. CONCLUSÃO: A TCMD permitiu o diagnóstico de diferentes tipos de trombose endoluminal em pacientes submetidos ao TEAAA. O uso desta modalidade diagnóstica minimamente invasiva deverá ser encorajado na prática clínica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os avanços nos cuidados com o paciente traumatizado e com infecções abdominais graves são responsáveis por um número crescente de peritoneostomias. O manejo desta entidade é complexo e várias técnicas foram descritas para seu tratamento. Recentemente foi introduzido na literatura o conceito de fechamento dinâmico da parede abdominal, com elevadas taxas de sucesso. O objetivo deste trabalho é de servir como nota prévia de uma nova abordagem para o tratamento das peritoneostomias, desenvolvida no Hospital Universitário da Universidade de São Paulo. Trata-se de um procedimento simples e de baixo custo, facilmente realizado por cirurgião geral. O procedimento também foi utilizado como reforço em fechamentos abdominais tensos, de maneira profilática. O procedimento é descrito em detalhes, assim como os resultados nos primeiros pacientes. Apesar de promissora, refinamentos técnicos e estudos complementares são necessários para a validação da técnica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: Hipotermia intra-operatória é complicação frequente, favorecida por operação abdominal. A eficácia da associação dos métodos de aquecimento por condução e convecção na prevenção de hipotermia e seus efeitos no período de recuperação pós-operatória foram os objetivos deste estudo. MÉTODO: Quarenta e três pacientes de ambos os sexos de 18 a 88 anos de idade, submetidos à laparotomia xifopúbica sob anestesia geral e monitorização da temperatura esofágica, foram distribuídos de modo aleatório em dois grupos de aquecimento: COND (n = 24), com colchão de circulação de água a 37°C no dorso e COND + CONV (n = 19), com a mesma condição associada à manta de ar aquecido a 42°C sobre o tórax e membros superiores. Analisados peso, sexo, idade, duração da operação e anestesia, temperaturas na indução anestésica (Mi), horas consecutiva (M1, M2), final da operação (Mfo) e anestesia (Mfa), entrada (Me-REC) e saída (Ms-REC) da recuperação pós-anestésica (SRPA), além das incidências de tremores e queixas de frio no pós-operatório. RESULTADOS: Os grupos foram semelhantes em todas as variáveis analisadas, exceto nas temperaturas em M2, M3, M4, Mfo e Mfa. O grupo COND reduziu a temperatura a partir da segunda hora da indução anestésica, mas o grupo COND + CONV só na quarta hora. Em COND, observou-se hipotermia na entrada e saída da SRPA. CONCLUSÕES: Associar métodos de aquecimento retardou a instalação e diminui a intensidade da hipotermia intra-operatória, mas não reduziu a incidência das queixas de frio e tremores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The antibacterial effect of ozone (O3) has been described in the extant literature, but the role of O3 therapy in the treatment of certain types of infection remains controversial. OBJECTIVES: To evaluate the effect of intraperitoneal (i.p.) O3 application in a cecal ligation/puncture rat model on interleukins (IL-6, IL-10) and cytokine-induced neutrophil chemoattractant (CINC)-1 serum levels, acute lung injury and survival rates. METHODS: Four animal groups were used for the study: a) the SHAM group underwent laparotomy; b) the cecal ligation/puncture group underwent cecal ligation/puncture procedures; and c) the CLP+O2 and CLP+O3 groups underwent CLP+ corresponding gas mixture infusions (i.p.) throughout the observation period. IL-6, CINC-1 and IL-10 concentrations were determined by enzyme-linked immunosorbent assay (ELISA). Acute lung injury was evaluated with the Evans blue dye lung leakage method and by lung histology. P<0.05 was considered significant. RESULTS: CINC-1 was at the lowest level in the SHAM group and was lower for the CLP+O3 group vs. the CLP+O2 group and the cecal ligation/puncture group. IL-10 was lower for the SHAM group vs. the other three groups, which were similar compared to each other. IL-6 was lower for the SHAM group vs. all other groups, was lower for the CLP+O3 or CLP+O2 group vs. the cecal ligation/puncture group, and was similar for the CLP+O3 group vs. the CLP+O2 group. The lung histology score was lower for the SHAM group vs. the other groups. The Evans blue dye result was lower for the CLP+O3 group vs. the CLP+O2 group and the cecal ligation/puncture group but similar to that of the SHAM group. The survival rate for the CLP+O3 group was lower than for the SHAM group and similar to that for the other 2 groups (CLP and CLP+O2). CONCLUSION: Ozone therapy modulated the inflammatory response and acute lung injury in the cecal ligation/puncture infection model in rats, although there was no improvement on survival rates.