552 resultados para ANEURYSM


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Computational fluid dynamic (CFD) studies of blood flow in cerebrovascular aneurysms have potential to improve patient treatment planning by enabling clinicians and engineers to model patient-specific geometries and compute predictors and risks prior to neurovascular intervention. However, the use of patient-specific computational models in clinical settings is unfeasible due to their complexity, computationally intensive and time-consuming nature. An important factor contributing to this challenge is the choice of outlet boundary conditions, which often involves a trade-off between physiological accuracy, patient-specificity, simplicity and speed. In this study, we analyze how resistance and impedance outlet boundary conditions affect blood flow velocities, wall shear stresses and pressure distributions in a patient-specific model of a cerebrovascular aneurysm. We also use geometrical manipulation techniques to obtain a model of the patient’s vasculature prior to aneurysm development, and study how forces and stresses may have been involved in the initiation of aneurysm growth. Our CFD results show that the nature of the prescribed outlet boundary conditions is not as important as the relative distributions of blood flow through each outlet branch. As long as the appropriate parameters are chosen to keep these flow distributions consistent with physiology, resistance boundary conditions, which are simpler, easier to use and more practical than their impedance counterparts, are sufficient to study aneurysm pathophysiology, since they predict very similar wall shear stresses, time-averaged wall shear stresses, time-averaged pressures, and blood flow patterns and velocities. The only situations where the use of impedance boundary conditions should be prioritized is if pressure waveforms are being analyzed, or if local pressure distributions are being evaluated at specific time points, especially at peak systole, where the use of resistance boundary conditions leads to unnaturally large pressure pulses. In addition, we show that in this specific patient, the region of the blood vessel where the neck of the aneurysm developed was subject to abnormally high wall shear stresses, and that regions surrounding blebs on the aneurysmal surface were subject to low, oscillatory wall shear stresses. Computational models using resistance outlet boundary conditions may be suitable to study patient-specific aneurysm progression in a clinical setting, although several other challenges must be addressed before these tools can be applied clinically.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND AIMS: Although it has become clear that aneurysmal and occlusive arterial disease represent two distinct etiologic entities, it is still unknown whether the two vascular pathologies are prognostically different. We aim to assess the long-term vital prognosis of patients with abdominal aortic aneurysmal disease (AAA) or peripheral artery disease (PAD), focusing on possible differences in survival, prognostic risk profiles and causes of death. METHODS: Patients undergoing elective surgery for isolated AAA or PAD between 2003 and 2011 were retrospectively included. Differences in postoperative survival were determined using Kaplan-Meier and Cox regression analysis. Prognostic risk profiles were also established with Cox regression analysis. RESULTS: 429 and 338 patients were included in the AAA and PAD groups, respectively. AAA patients were older (71.7 vs. 63.3 years, p < 0.001), yet overall survival following surgery did not differ (HR: 1.16, 95% CI: 0.87-1.54). Neither was type of vascular disease associated with postoperative cardiovascular nor cancer-related death. However, in comparison with age- and gender-matched general populations, cardiovascular mortality was higher in PAD than AAA patients (48.3% vs. 17.3%). Survival of AAA and PAD patients was negatively affected by age, history of cancer and renal insufficiency. Additional determinants in the PAD group were diabetes and ischemic heart disease. CONCLUSIONS: Long-term survival after surgery for PAD and AAA is similar. However, overall life expectancy is significantly worse among PAD patients. The contribution of cardiovascular disease towards mortality in PAD patients warrants more aggressive secondary prevention to reduce cardiovascular mortality and improve longevity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the case of a 82-year-old woman, asymptomatic, subject to chest computed tomography for trauma. Then the patient underwent surgery. Before sternotomy, femoro-femoral bypass was starter in order to decompress the aneurysm; using deep hypothermia and circulatory arrest, ascending aorta and hemiarch replacement were performed with a Dacron graft. Post-operative course was uneventful.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. We report a case of ulnar and palmar arch artery aneurysm in a 77 years old man without history of any occupational or recreational trauma, vasculitis, infections or congenital anatomic abnormalities. We also performed a computed search of literature in PUBMED using the keywords “ulnar artery aneurysm” and “palmar arch aneurysm”. Case report. A 77 years old male patient was admitted to hospital with a pulsing mass at distal right ulnar artery and deep palmar arch; at ultrasound and CT examination a saccular aneurysm of 35 millimeters at right ulnar artery and a 15 millimeters dilatation at deep palmar arch were detected. He was asymptomatic for distal embolization and pain. In local anesthesia ulnar artery and deep palmar arch dilatations were resected. Reconstruction of vessels was performed through an end-to-end microvascular repair. Histological examination confirmed the absence of vasculitis and collagenopaties. In postoperative period there were no clinical signs of peripheral ischemia, Allen’s test and ultrasound examination were normal. At follow-up of six months, the patient was still asymptomatic with a normal Allen test, no signs of distal digital ischemia and patency of treated vessel with normal flow at duplex ultrasound. Conclusion. True spontaneous aneurysms of ulnar artery and palmar arch are rare and can be successfully treated with resection and microvascular reconstruction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives CO2-EVAR was proposed for treatment of AAA especially in patients with CKD. Issues regarding standardization, such as visualization of lowest renal artery (LoRA) and quality image in angiographies performed from pigtail or introducer-sheath, are still unsolved. Aim of the study was to analyze different steps of CO2-EVAR to create an operative protocol to standardize the procedure. Methods Patients undergoing CO2-EVAR were prospectively enrolled in 5 European centers (2018-2021). CO2-EVAR was performed using an automated injector. LoRA visualization and image quality (1-4) were analyzed and compared at different procedure steps: preoperative CO2-angiography from Pigtail/Introducer-sheath (1st Step), angiographies from Pigtail at 0%,50%,100% main body (MB) deployment (2nd Step), contralateral hypogastric artery (CHA) visualization with CO2 injection from femoral Introducer-sheath (3rd Step) and completion angiogram from Pigtail/Introducer-sheath (4th Step). Intra-/postoperative adverse events were evaluated. Results Sixty-five patients undergoing CO2-EVAR were enrolled, 55/65(84.5%) male, median age 75(11.5) years. Median ICM was 20(54)cc; 19/65(29.2%) procedures were performed with 0-iodine. 1st Step: median image quality was significantly higher with CO2 injected from femoral introducer [Pigtail2(3)vs.3(3)Introducer,p=.008]. 2nd Step: LoRA was more frequently detected at 50% (93%vs.73.2%, p=.002) and 100% (94.1%vs.78.4%, p=.01) of MB deployment compared with first angiography from Pigtail; image quality was significantly higher at 50% [3(3)vs.2(3),p=<.001] and 100% [4(3) vs.2(3),p=.001] of MB deployment. CHA was detected in 93% cases (3rd Step). Mean image quality was significantly higher when final angiogram (4th Step) was performed from introducer (Pigtail2.6±1.1vs.3.1±0.9Introducer,p=<.001). Rates of intra-/postoperative adverse events (pain,vomit,diarrhea) were 7.7% and 12.5%. Conclusions Preimplant CO2-angiography should be performed from Introducer-sheath. MB steric bulk during its deployment should be used to improve image quality and LoRA visualization with CO2. CHA can be satisfactorily visualized with CO2. Completion CO2-angiogram should be performed from femoral Introducer-sheath. This operative protocol allows to perform CO2-EVAR with minimal ICM and low rate of mild complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study is to evaluate if spinal cord ischemia (SCI), especially its late presentation, and can be correlated to the results of intraoperative evoked potential monitoring (IOM). Methods. This study is a physician-initiated, retrospective, single-center, non-randomized study. Data from all patients undergoing a thoracoabdominal aortic aneurysm surgical repair (TAAA SR) between January 2016 and March 2020 IOM was collected and analyzed. Results. During the study period, 261 patients underwent TAAA SR with MEP/SSEPs monitoring [190 males, 73%; median age 65 (57-71)]. Thirty-seven patients suffered from SCI, for an overall rate of 14% (permanent 9%). When stratifying patients according to the SCI onset, 18 patients presented with an early (11 permanent) and 19 with a late SCI (<24h) (11 permanent). Of 261 patients undergoing TAAA SR with IOM, 15 were excluded due to changes in the upper extremity motor evoked potentials. For the remaining 246, the association between SCI and IOM was investigated: only irreversible IOM loss without peripheral changes have been found to be a risk factor for late onset SCI (p=.006). Furthermore, given that no statistical differences were found between the two groups when no IOM changes were recorded (p=.679), this situation cannot reliably rule out any SCI in our cohort. Independent risk factors for late spinal cord ischemia onset found at multivariate analysis were smoking history (p=.008), BMI>28 (p=.048) and TAAA extent II (p=.009). The irreversible MEP change without peripheral showed a trend of significance (p=.052). Conclusions. Evoked potential intraoperative monitoring is an important adjunct during thoracoabdominal aortic open repair to predict and possibly prevent spinal cord ischemia. Irreversible IOM loss without peripheral changes was predictive of late SCI, therefore more attention should be paid to the postoperative management of this subgroup of patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abdominal aortic aneurysm is the pathological dilation of the abdominal tract of the aorta and, if left untreated, could undergo rupture with a mortality rate of up to 90%. EVAR is the most common method for AAA treatment consisting in the internal coverage of the aorta with a metallic stent to isolate the aneurysmatic segment from the systemic circulation. Although EVAR technical success rate is high, reinterventions are common. Among the causes of reinterventions typeII endoleaks are the most frequent and consist in retrograde blood flow into the aneurysmal sac from collateral aortic branches. Continued perfusion of the aneurysm sac may lead to aneurysm rupture, therefore AAA sac embolization is performed using metallic coils. However, the presence of artifacts caused by the presence of metallic coils is a limitation because they are radiopaque and can hamper the endoleak during imaging follow-up. This study is aimed at developing a biocompatible hydrogel that could be injected into the aneurysmal sac and may allow a selective intraprocedural sac embolization to reduce post procedural typeII endoleak and eventual AAA rupture. P(BT75BSI25) was synthesized by polycondensation and its biocompatibility tested to assess whether the polymers had no toxic effects. HUVEC cell line was used to mimic the environment in which the polymer would be in contact with, PBS was used as a positive control and MTT assay was performed to evaluate cellular viability after being in contact with the hydrogel. MTT assay showed no significant difference between PBS and P(BT75BSI25), thus the polymer is biocompatible, as confirmed by the analysis of apoptosis by flow cytometry. An aromatic copolymer was obtained via polycondensation and was found to be biocompatible in contact with endothelial cells. This suggests that the hydrogel could be potentially used in the clinical setting for the treatment of type II endoleak after EVAR.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two cases of giant intracavernous aneurysms treated by high flow bypass with saphenous vein graft between the external carotid artery (ECA) and branches of the middle cerebral artery (MCA) are presented. Very often these aneurysms are unclippable because they are fusiform or have a large neck. Occlusion of the internal carotid artery (ICA) is the treatment of choice in many cases. This procedure has however a high risk of brain infarction. Revascularization of the brain by extra-intracranial anastomosis between the superficial temporal artery (STA) and branches of the MCA is frequently performed. This procedure provides however a low flow bypass and brain infarction may occur. We report two cases of giant cavernous sinus aneurysms treated by high flow bypass and endovascular balloon occlusion of the ICA. Immediate high flow revascularization of MCA branches was achieved and the patients showed no ischemic events. Follow-up of 8 and 14 months after operation shows patency of the venous graft and no neurological deficits. Angiographic control examination showed complete aneurysm occlusion in both cases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A case of giant aneurysm of the left middle cerebral artery, in a 28-year-old right-handed woman, successfuly operated is reported. The aneurysm measur- ing 35 x 27 x 23 mm showed clinical manifestations as a space-occupying lesion. The patient recovered completely after the total excision of the aneurysm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliar as características demográficas e de imagens da trombose endoluminal em uma série de pacientes submetidos a tratamento endovascular do aneurisma de aorta abdominal (TEAAA). MÉTODOS: Avaliamos as características de imagem que permitiram o diagnóstico da trombose endoluminal em uma série de 30 pacientes submetidos ao TEAAA, com seguimento de 5 a 29 meses, através de exames de tomografia computadorizada multidetectores (TCMD) de 64 canais. RESULTADOS: Foram diagnosticados dez casos de trombose luminal (33,3%), sendo que em três pacientes a trombose foi total de um ramo ilíaco. CONCLUSÃO: A TCMD permitiu o diagnóstico de diferentes tipos de trombose endoluminal em pacientes submetidos ao TEAAA. O uso desta modalidade diagnóstica minimamente invasiva deverá ser encorajado na prática clínica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: A doença de Kawasaki é uma vasculite sistêmica aguda de etiologia desconhecida. Seu diagnóstico baseia-se em critérios clínicos. O objetivo deste estudo foi descrever os casos de pacientes com doença de Kawasaki internados no Hospital Universitário da Universidade de São Paulo entre janeiro/2000 e junho/2008. MÉTODOS: Dentre todos os pacientes internados na Enfermaria de Pediatria no período acima, foram selecionados aqueles cujo CID de alta foi doença de Kawasaki. Realizou-se estudo descritivo por meio da análise dos prontuários dessas crianças. RESULTADOS: Foram encontrados 18 casos. A média de internações foi de 2,1 casos/ano. A idade variou de três meses a nove anos. A proporção meninos:meninas foi 1:1,25. Receberam outros diagnósticos prévios 17 pacientes, sendo escarlatina em 2/3 dos casos. O tempo de febre antes do diagnóstico variou de cinco a 11 dias. Nove crianças apresentaram quatro sinais sugestivos de doença de Kawasaki; oito apresentaram cinco sinais e uma apresentou dois sinais, o que foi considerado doença de Kawasaki incompleta. Receberam gamaglobulina 15 crianças (entre o sexto e o décimo dias de evolução) e 11 (73%) ficaram afebris após infusão da medicação. Os demais tiveram febre até 24 horas após a administração. Todos os pacientes realizaram ecocardiograma e três apresentaram aneurisma leve da coronária. CONCLUSÕES: A doença de Kawasaki é habitualmente confundida com outras doenças, o que causa retardo no tratamento e aumento no risco de complicações cardíacas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hemorrhage in regions remote from the site of initial intracranial operations is rare, but may be fatal. Postoperative cerebellar hemorrhage as a complication of supratentorial surgery, with a radiological appearance known as zebra sign, is an increasingly recognized clinical entity and is associated mainly with vascular neurosurgery or temporal lobe resection. The pathophysiology remains unclear. Three cases of remote cerebellar hematoma occurred after neck clipping of anterior communicating artery aneurysms. All patients had similar clinical findings and underwent pterional craniotomy with the head in accentuated extension. One patient died and the two were discharged without symptoms. Cerebellar hemorrhage probably has a multifactorial origin involving positioning associated with abundant cerebrospinal fluid drainage causing cerebellar sag with resultant vein stretching and bleeding, and use of aspirin or other antiplatelet agents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Evidence of infection with spirorchid flukes (Digenea: Spirorchidae) was sought at necropsy of 96 stranded green turtles, Chelonia mydas, that were examined during the course of a survey of marine turtle mortality in southeastern Queensland, Australia. Three species of spirorchid (Hapalotrema mehrai, H. postorchis, and Neospirorchis schistosomatoides) were identified. Severe disease due to spirorchid fluke infection (spirorchidiasis) was implicated as the principal cause of mortality in 10 turtles (10%), and appeared to be one of multiple severe problems in an additional 29 turtles (30%). Although flukes were observed in only 45% of stranded C. mydas in this study, presumed spirorchid fluke infection was diagnosed in an additional 53% of turtles, based principally on characteristic necropsy lesions and to a lesser extent on the histopathological detection of spirorchid eggs. Characteristic necropsy lesions included miliary spirorchid egg granulomas, which were observed most readily on serosal surfaces, particularly of the small intestine. Cardiovascular lesions included mural endocarditis, arteritis, and thrombosis, frequently accompanied by aneurysm formation. Resolution of thrombi was observed to occur via a combination of granuloma formation about indigestible components (spirorchid fluke egg shells) and exteriorization through the vessel wall, which resulted in granulomatous nodules on the adventitial surface. Septic aortic thrombosis complicated by disseminated bacterial infection, observed in five turtles, was recorded for the first time. Egg granulomas were ubiquitous in turtle tissues throughout this study. Although they generally appeared to be mild or incidental lesions, they were occasionally associated with severe multifocal granulomatous pneumonia or meningitis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method by which to overcome the clinical symptoms of atherosclerosis is the insertion of a graft to bypass an artery blocked or impeded by plaque. However, there may be insufficient autologous mammary artery for multiple or repeat bypass, saphenous vein may have varicose degenerative alterations that can lead to aneurysm in high-pressure sites, and small-caliber synthetic grafts are prone to thrombus induction and occlusion. Therefore, the aim of the present study was to develop an artificial blood conduit of any required length and diameter from the cells of the host for autologous transplantation. Silastic tubing, of variable length and diameter, was inserted into the peritoneal cavity of rats or rabbits. By 2 weeks, it had become covered by several layers of myofibroblasts, collagen matrix, and a single layer of mesothelium. The Silastic tubing was removed from the harvested implants, and the tube of living tissue was everted such that it now resembled a blood vessel with an inner lining of nonthrombotic mesothelial cells (the intima), with a media of smooth muscle-like cells (myofibroblasts), collagen, and elastin, and with an outer collagenous adventitia. The tube of tissue (10 to 20 mm long) was successfully grafted by end-to-end anastomoses into the severed carotid artery or abdominal aorta of the same animal in which they were grown. The transplant remained patent for at least 4 months and developed structures resembling elastic lamellae. The myofibroblasts gained a higher volume fraction of myofilaments and became responsive to contractile agonists, similar to the vessel into which they had been grafted. It is suggested that these nonthrombogenic tubes of living tissue, grown in the peritoneal cavity of the host, may be developed as autologous coronary artery bypass grafts or as arteriovenous access fistulae for hemodialysis patients.