893 resultados para 1084


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite recent advances, patients with malignant brain tumors still have a poor prognosis. Glioblastoma (WHO grade 4 astrocytoma), the most malignant brain tumor, represents 50% of all astrocytomas, with a median survival rate of <1 year. It is, therefore, extremely important to search for new diagnostic and therapeutic approaches for patients with glioblastoma. This study describes the application of superparamagnetic nano-particles of iron oxide, as well as monoclonal antibodies, of immunophenotypic significance, conjoined to quantum dots for the ultrastructural assessment of glioblastoma cells. For this proposal, an immunophenotypic study by flow cytometry was carried out, followed by transmission electron microscopy analysis. The process of tumor cell labeling using nanoparticles can successfully contribute to the identification of tumorigenic cells and consequently for better understanding of glioblastoma genesis and recurrence. In addition, this method may help further studies in tumor imaging, diagnosis, and prognostic markers detection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste estudo foi comparar a taxa de desenvolvimento de força (TDF) nas contrações isométrica e isocinética concêntrica a 60°.s-1 e 180°.s-1. Quatorze indivíduos do gênero masculino (idade = 23,1 ± 2,8 anos; estatura = 174 ± 31,3cm; massa corporal = 81 ± 12kg) realizaram inicialmente uma familiarização ao equipamento isocinético. Posteriormente, os indivíduos realizaram em ordem randômica cinco contrações isocinéticas máximas para os extensores do joelho a 60°.s-1 e 180°.s-1 para determinar o torque máximo concêntrico (TMC) e duas contrações isométricas máximas de 3s para determinar o torque máximo isométrico (TMI). O TMI (301,4 ± 56,0N.m) foi maior do que o TMC a 60°.s-1 (239,8 ± 42,2N.m) e 180°.s-1 (175,0 ± 32,5 N.m). O TMC a 60°.s-1 foi maior do que o TMC a 180°.s-1. Para os intervalos de 0-30ms e 0-50ms, a TDF na condição isométrica (1.196,6 ± 464,6 e 1.326,5 ± 514,2N.m.s-1, respectivamente) foi similar à TDF a 60°.s-1 (1.035,4 ± 446,2 e 1.134,3 ± 448,4N.m.s-1) e maior do que a 180°.s-1 (656,7 ± 246,6 e 475,2 ± 197,9N.m.s-1), sendo ainda que a TDF na contração concêntrica a 180°.s-1 foi menor do que a 60°.s-1. No intervalo de 0-100ms, a TDF da contração isométrica (1.248,8 ± 417,4N.m.s-1) foi maior que a obtida na contração isocinética rápida (909,2 ± 283,4N.m.s-1). A TDF obtida na contração isocinética lenta (1.005,4 ± 247,7N.m.s-1) foi similar à obtida na contração isométrica e na concêntrica isocinética rápida. No intervalo 0-150ms, a TDF isométrica (1.084,2 ± 332,1N.m.s-1) foi maior do que as concêntricas (60°.s-1 e 180°.s-1) (834,8 ± 184,2 e 767,6 ± 201,8N.m.s-1, respectivamente), não existindo diferenças entre estas duas últimas. Conclui-se que a TDF é dependente do tipo e da velocidade de contração, suportando a hipótese de que maiores velocidades de contração acarretam maior inibição do drive neural no início do movimento.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Running exercises are frequently related to muscular injuries, which may be a result of muscular imbalance. The present study aimed to verify the effects of heavy-intensity continuous running exercise on the functional and conventional hamstrings: quadriceps ratios, and also in the knee flexors and extensors EMG activity in active non-athletic individuals. Sixteen active males performed maximal isokinetic concentric and eccentric knee flexions and extensions at 60 degrees s(-1) and 180 degrees s(-1). In another session, the same procedure was conducted after a continuous running exercise at 95% onset of blood lactate accumulation. Torque and electromyographic ratios were calculated from peak torque and integrated electromyographic activity (knee flexor and extensors). Creatine kinase was measured before and 24 h after running exercise. Eccentric torque (knee flexion and extension) decreased significantly after running only at 180 degrees s(-1) (p < 0.05). No differences were found for the conventional torque ratios (p > 0.05), however, the functional torque ratios at 180 degrees s(-1) decreased significantly after running (p < 0.05). No effects on the electromyographic activity and electronnyographic ratios were found (p > 0.05). Creatine kinase increased slightly 24 h after running (p < 0.05). Heavy-intensity continuous running exercise decreased knee flexor and extensor eccentric torque, and functional torque ratios under fast velocities (180 degrees s(-1)), probably as result of peripheral fatigue. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Estudos relacionados ao perfil do consumidor colocam-se como importante subsídio à participação competitiva dos diferentes segmentos nas cadeias agroalimentares e para a própria organização da mesma. O objetivo do presente trabalho foi o de identificar o perfil dos consumidores de frutas em cidades do interior do Estado de São Paulo. A amostra foi constituída de 404 consumidores em pontos de venda previamente selecionados nas cidades de Botucatu, Avaré, Jaboticabal, Ilha Solteira e Tupã. Os resultados sobre o perfil do consumidor de frutas nas cidades pesquisadas sinalizam uma preocupação com as características do produto (saudáveis e saborosos), com o preço e com facilidades de acesso na compra. Os resultados apontam também para a necessidade de maiores estudos sobre a importância da informação relacionada aos aspectos mais valorizados (características do produto e preço) na estrutura de consumo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work it was investigated the effect of the exposure to different plasmas on the wettability of silicone samples. We have observed that oxygen. argon, and hydrogen glow discharges are quite effective in reducing the water contact angle of such polymer. However, indifferently to efficiency of the treatment, practically all the modified surfaces recovered great part of their original hydrophobicity. We have investigated this hydrophobic recovery using surface energy measurements and theoretical simulations based on the exponential decay of the population of polar groups on the surface. According to our results such recovery can be attributed to the decrease of polar species at the interface water-polymer surface.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The limitation of photoactivation of dual-polymerized resin cements along the margins of metal restorations may adversely affect the mechanical properties of these cements, thus impairing the retention of restorations. The aim of this study was to assess the bond strength of cast metal crowns cemented with three dual-polymerized resin cements, using a chemically-activated resin cement and zinc phosphate as controls. Fifty nickel-chromium alloy crowns were cast and randomly assigned to five groups of equal size. Castings were cemented on their corresponding metal dies with one of the tested luting agents: Scotchbond Resin Cement, Enforce and Panavia F (dual-polymerized resin cements), Cement-It (chemically-activated resin cement) and Zinc Phosphate Cement (zinc phosphate cement). Specimens were stored in distilled water at 37 degreesC for 24 h and then loaded in tension until failure. Panavia F and Zinc Phosphate Cement provided the highest and lowest bond strength means, respectively. Scotchbond Resin Cement, Enforce and Cement-It cements exhibited similar intermediate values, but with statistically significant difference compared to the other materials (P < 0.05). Even with the restriction or absence of light activation, all tested dual-polymerized resin cements produced significantly higher bond strength than did the zinc phosphate cement and yielded similar or better results than the chemically activated cement. It should be pointed out that the findings of this study relate to a test scenario which does not mimic clinical circumstances and that further work is required to identify the clinical significance of the reported tensile bond strength differences between the different luting materials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Zirconia-ceria powders with ceria concentration varying from 0 to 12 mol% were synthesized using a polymeric precursor route based on the Pechini process. Powder characteristics were evaluated with regard to the crystallite size, BET surface area, phase distribution, nitrogen adsorption/desorption behavior, and agglomeration state. Sintering was studied considering the shrinkage rate, densification, grain size, and phase evolution. It was demonstrated that the synthesis method is effective to prepare nanosized powders of tetragonal zirconia single-phase. Sinterability mainly depended on the agglomeration state of powders and the monoclinic phase content, fully tetragonal zirconia ceramic, with grain size of 2.4 mu m, was obtained after addition of at least 9 mol% ceria and sintering at 1500 degrees C for 4 h. (C) 2000 Elsevier B.V. Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We studied the use of multiwavelength diode lasers for surface profilometry through holographic recording in sillenite Bi(12)TiO(20) crystals. When such lasers are used, the holographic image from single-exposure recordings appears covered with interference fringes providing information on the surface relief of the object. By taking advantage of the narrow interference fringes due to the multiwavelength emission of the laser, we obtained interferograms by holographic recording with two reference beams, which improves the surface analysis by visual inspection and enhances the profilometry sensitivity. (c) 2005 Optical Society of America.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Commercial polyvinylchloride (PVC) sheets were treated by plasma immersion ion implantation, PIII. Samples were immersed in argon glow discharges and biased with 25 kV negative pulses. Exposure time to the bombardment plasma changed from 900 to 10,800 s. Through contact angle measurements, the effect of the exposure time on the PVC wettability was investigated. Independent of t, all samples presented contact angles, theta, equal to zero after the treatment. However, in some cases, surface hydrophilization was not stable, as revealed by the temporal evolution of theta. Samples bombarded for shorter periods recovered partially or totally the hydrophobic character while the one exposed for the longest time stayed highly hydrophilic. These modifications are ascribed to the Cl loss and O incorporation as shown by XPS measurements. Furthermore, the mobility of surface polar groups and the variation in the cross-linking degree can also affect the PVC wettability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pure and Nb doped PbZr0.4Ti0.603 thin films was prepared by the polymeric precursor method and deposited by spin coating on Pt/Ti/SiO2/Si (100) substrates and annealed at 700 degreesC. The films are oriented in (1 1 0) and (1 0 0) direction. The electric properties of PZT thin films show strong dependence of the crystallographic orientation. The P-E hysteresis loops for the thin film with composition PbZr0.39Ti0.6Nb0.103 showed good saturation, with values for coercive field (E-c) equal to 60 KV cm(-1) and for remanent polarization (P-r) equal to 20 muC cm(-2). The measured dielectric constant (epsilon) is 1084 for this film. These results show good potential for application in FERAM. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)