984 resultados para tip credits


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A procedure is proposed to determine, for second-phase particles near a crack tip, the maximum particle stresses at the moment of void initiation by either particle fracture or particle/matrix interface separation. A digital image analysis system is applied to perform a quantitative analysis of corresponding fracture surface regions from stereo image pairs taken in the scanning electron microscope. The fracture surface analysis is used to measure, for individual particles, the crack tip opening displacement at the moment of void initiation and the particle location with respect to the crack tip. From these data, the stress tensor at the moment of void initiation is calculated from the Hutchinson–Rice–Rosengren (HRR) field theory. The corresponding average local stresses within the particle are evaluated by a non-linear Mori–Tanaka-type approach. These stresses are compared to estimates according to the models by Argon et al. [A.S. Argon, J. Im, R. Safoglu, Metall. Trans. 6 (1975) 825] and Beremin [F.M. Beremin, Metall. Trans. 12 (1981) 723]. The procedure is demonstrated on an Al6061–10% Al2O3 metal matrix composite.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Genotoxicity potential of soils taken from wastewater irrigation areas and bioremediation sites was assessed using the Vicia faba root tip micronucleus assay. Twenty five soils were tested, of which 8 were uncontaminated soils and taken as the control to examine the influence of soil properties; 6 soils were obtained from paddy rice fields with a history of long-term wastewater irrigation; 6 soils were obtained from bioremediation sites to examine effects of bioremediation; and 5 PAH-contaminated soils were used to examine methodological effects between direct soil exposure and exposure to aqueous soil extracts on micronuclei (MN) frequency () in the V. faba root tips. Results indicate that soil properties had no significant influences on MN frequencies (p > 0.05) when soil pH varied between 3.4 to 7.6 and organic carbon between 0.4% and 18.6%. The MN frequency measured in these control soils ranged from 1.6‰ to 5.8‰. MN frequencies in soils from wastewater irrigation areas showed 2- to 48-fold increase as compared with the control. Soils from bioremediation sites showed a mixed picture: MN frequencies in some soils decreased after bioremediation, possibly due to detoxification; whereas in other cases remediated soils induced higher MN frequencies, suggesting that genotoxic substances might be produced during bioremediation. Exposure to aqueous soil extracts gave a higher MN frequency than direct exposure in 3 soils. However, the opposite was observed in the other two soils, suggesting that both exposure routes should be tested in case of negative results from one route. Data obtained from this study indicate that the MN assay is a sensitive assay suitable for evaluating genotoxicity of soils.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although coordinate metrology has reached a very high state of development concerning versatility and accuracy for common engineering parts, a high precision capability with nano scale resolution and accuracy is often hard to achieve when it is required to measure very small parts and features. The limiting component is the bulky probing system of traditional CMMs (coordinate measuring machines). In order to satisfy increasing demand for highly accurate geometrical measurements on small parts and small structures, a new measuring probe of high sensitivity and small geometrical dimension with low contact forces needs to be developed. In this paper, a novel probing system, which combines a FBG (Fibre Bragg Grating) embedded optical fibre tactile probe with an optical sensing technique, has been proposed. With the sensor elements integrated into the probe tip directly, the system sensitivity can be increased significantly. A preliminary theoretical analysis of the sensitivity of the FBG fibre sensor under axial and lateral end point loading has been presented and the results show that this micro scale probe has great potential to realize a resolution of 1nanometer on geometrical measurement of small parts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diversity of the V3 loop tip motif sequences of HIV-1 subtype B was analyzed in patients from Botucatu (Brazil) and Montpellier (France). Overall, 37 tetrameric tip motifs were identified, 28 and 17 of them being recognized in Brazilian and French patients, respectively. The GPGR (P) motif was predominant in French but not in Brazilian patients (53.5% vs 31.0%), whereas the GWGR (W) motif was frequent in Brazilian patients (23.0%) and absent in French patients. Three tip motif groups were considered: P, W, and non-P non-W groups. The distribution of HIV-1 isolates into the three groups was significantly different between isolates from Botucatu and from Montpellier (P < 0.001). A higher proportion of CXCR4-using HIV-1 (X4 variants) was observed in the non-P non-W group as compared with the P group (37.5% vs 19.1%), and no X4 variant was identified in the W group (P < 0.001). The higher proportion of X4 variants in the non-P non-W group was essentially observed among the patients from Montpellier, who have been infected with HIV-1 for a longer period of time than those from Botucatu. Among patients from Montpellier, CD4+ cell counts were lower in patients belonging to the non-P non-W group than in those belonging to the P group (24 cells/µL vs 197 cells/µL; P = 0.005). Taken together, the results suggest that variability of the V3 loop tip motif may be related to HIV-1 coreceptor usage and to disease progression. However, as analyzed by a bioinformatic method, the substitution of the V3 loop tip motif of the subtype B consensus sequence with the different tip motifs identified in the present study was not sufficient to induce a change in HIV-1 coreceptor usage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: A giant fusiform aneurysm in the posterior cerebral artery (PCA) is rare, as is fenestration of the PCA and basilar apex variation. We describe the angiographic and surgical findings of a giant fusiform aneurysm in the P1-P2 PCA segment associated with PCA bilateral fenestration and superior cerebellar artery double origin.CLINICAL PRESENTATION: A 26-year-old woman presented with a 2-month history of visual blurring. Digital subtraction angiography showed a giant (2.5 cm) fusiform PCA aneurysm in the right P1-P2 segment. The 3-dimensional view showed a caudal fusion pattern from the upper portion of the basilar artery associated with a bilateral long fenestration of the P1 and P2 segments and superior cerebellar artery double origin.INTERVENTION: Surgical trapping of the right P1 -P2 segment, including the posterior communicating artery, was performed by a pretemporal approach. Angiograms performed 3 and 13 months after surgery showed complete aneurysm exclusion, and the PCA was permeated and filled the PCA territory. Clinical follow-up at 14 months showed the patient with no deficits and a return to normal life.CONCLUSION: To our knowledge, this is the first report of a giant fusiform aneurysm of the PCA associated with P1-P2 segment fenestration and other variations of the basilar apex (bilateral superior cerebellar artery duplication and caudal fusion). Comprehension of the embryology and anatomy of the PCA and its related vessels and branches is fundamental to the decision-making process for a PCA aneurysm, especially when parent vessel occlusion is planned.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo prospectivo avaliou os métodos semiquantitativo e qualitativo de cultura de cateter para o diagnóstico de infecção relacionada a cateter (IRC) em recém-nascidos (RN). Foram incluídas pontas de cateteres provenientes de recém-nascidos internados na Unidade Neonatal do Hospital das Clínicas da Faculdade de Medicina de Botucatu, UNESP. Foram utilizadas as técnicas semiquantitativa e qualitativa de cultura de cateter. Para o diagnóstico de IRC, os microrganismos isolados das culturas de cateteres e de hemoculturas periféricas foram identificados e submetidos ao teste de sensibilidade a antimicrobianos. O padrão ouro correspondeu ao diagnóstico de certeza de IRC, com o isolamento do mesmo microrganismo (espécie e perfil de sensibilidade a antimicrobianos) isolado em hemocultura periférica. Foram estudados 85 cateteres provenientes de 63 RN. A cultura semiquantitativa, embora tenha apresentado menor sensibilidade (90%), apresentou uma maior especificidade (71%) em comparação à sensibilidade de 100% e especificidade de 60% encontradas na cultura qualitativa. Através da identificação dos microrganismos obtidos nas culturas de cateteres, observou-se uma predominância de espécies de Estafilococos coagulase-negativa (ECN). A espécie Staphylococcus epidermidis foi a prevalente (77,5%) nos cateteres com culturas semiquantitativas positivas. Dos 11 episódios de IRC diagnosticados, 8 (72,7%) foram associados a espécies de ECN, dos quais 6 eram da espécie S. epidermidis. Também foram detectados dois casos de IRC por S. aureus e um caso por Candida parapsilosis. O método de cultura semiquantitativo cateter apresentou vantagens para o diagnóstico de IRC em RN quando comparado com o método qualitativo tradicional.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To determine the number of colony-forming units (CFU) that best correlates with catheter-related infections (CRI) in newborns.Methods: This was a prospective study of semiquantitative cultures of catheter tips obtained from newborns in the neonatal unit at Faculdade de Medicina de Botucatu, state of São Paulo, Brazil. The microorganisms isolated from catheter and peripheral blood cultures were identified and submitted to a drug susceptibility test. The optimal cutoff point was determined by the receiver operating characteristic (ROC) curve.Results: A total of 85 catheters obtained from 63 newborns were studied. Staphylococcus epidermidis was the predominant species in the catheters (75%). Eight of 11 (72.7%) CRI episodes were associated with coagulase-negative staphylococci, six of which were of the S. epidermidis type. ROC curve analysis indicated that the optimal cutoff point for the diagnosis of CRI was 122 CFU.Conclusions: The cutoff point of 122 CFU correlated best with the diagnosis of CRI in newborns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a new strategy for the label-free electrochemical detection of DNA hybridization for detecting hepatitis C virus based on electrostatic modulation of the ion-exchange kinetics of a polypyrrole film deposited at microelectrodes. Synthetic single-stranded 18-mer HCV genotype-1-specific probe DNA has been immobilized at a 2,5-bis(2-thienyl)-N-(3-phosphoryl-n-alkyl)pyrrole film established by electropolymerization at the previously formed polypyrrole layer. HCV DNA sequences (244-mer) resulting from the reverse transcriptase-linked polymerase chain reaction amplification of the original viral RNA were monitored by affecting the ion-exchange properties of the polypyrrole film. The performance of this miniaturized DNA sensor system was studied in respect to selectivity, sensitivity, and reproducibility. The limit of detection was determined at 1.82 x 10(-21) mol L-1. Control experiments were performed with cDNA from HCV genotypes 2a/c, 2b, and 3 and did not show any unspecific binding. Additionally, the influence of the spacer length of 2,5-bis(2-thienyl)-N-(3-phosphoryl-n-alkyl)pyrrole on the behavior of the DNA sensor was investigated. This biosensing scheme was finally extended to the electrochemical detection of DNA at submicrometer-sized DNA biosensors integrated into bifunctional atomic force scanning electrochemical microscopy probes. The 18-mer DNA target was again monitored by following the ion-exchange properties of the polypyrrole film. Control experiments were performed with 12-base pair mismatched sequences.