974 resultados para time sensitive window


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The recovery of sperm from the epididymal cauda may be the last chance to obtain genetic material when sudden death or serious injuries occur in valuable stallions. However, the lack of technical knowledge regarding the storage and transportation of the epididymis often prevents the preservation of the sperm. Therefore, the aim of this study was to compare sperm parameters of sperm obtained immediately after orchiectomy with sperm recovered from epididymal cauda at different times after storage at 5°C and at room temperature (RT). For that, 48 stallions of different breeds were used. In group 1 (control group), eight stallions were used, and the harvest of the epididymal sperm was performed immediately after orchiectomy. In group 2, 40 stallions were used, which were divided into five groups according to the storage time of the epididymis after orchiectomy (6, 12, 18, 24, or 30 hours), making a total of eight stallions per group. One epididymis of each stallion was stored at 5°C, and the contralateral epididymis was stored at RT, both for the same period. The sperm parameters of total motility, progressive motility, progressive linear velocity, curvilinear velocity, percentage of rapid sperm, and plasma membrane integrity were evaluated in all the groups after sperm recovery, resuspension in a sperm freezing diluent, and thawing. In conclusion, the storage of the testis-epididymis complex at 5°C provided better preservation of epididymal sperm than the storage at RT, and regardless of the temperature, the progressive motility is the sperm parameter that is most sensitive to storage time. © 2013 Elsevier Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Poor posture control has been associated with an increased risk of falls and mobility disability among older adults. This study was conducted to assess the test-retest reliability and sensitivity to group differences regarding the time-limit (TLimit) of one-leg standing and selected balance parameters obtained with a force platform in older and young adults. A secondary purpose was to assess the relationship between TLimit and these balance parameters. Twenty-eight healthy older adults (age: 69±5years) and thirty young adults (age: 21±4years) participated in this study. Two one-leg stance tasks were performed: (1) three trials of 30s maximum and (2) one TLimit trial. The following balance parameters were computed: center of pressure area, RMS sway amplitude, and mean velocity and mean frequency in both the anterio-posterior and medio-lateral directions. All balance parameters obtained with the force platform as well as the TLimit variable were sensitive to differences in balance performance between older and young adults. The test-retest reliability of these measures was found to be acceptable (ICC: 0.40-0.85), with better ICC scores observed for mean velocity and mean frequency in the older group. Pearson correlations coefficients (r) between balance parameters and TLimit ranged from -0.16 to -0.54. These results add to the current literature that can be used in the development of measurement tools for evaluating balance in older and young adults. © 2013 Elsevier Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This publication summarizes the "Report on application of the Brasilia Declaration and the Regional Strategy for the Implementation in Latin America and the Caribbean of the Madrid International Plan of Action on Ageing", which will be presented at the Third Regional Intergovernmental Conference on Ageing in Latin America and the Caribbean, to be held in San José from 8 to 11 May 2012.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Classification of Time-Use Activities for Latin America and the Caribbean (CAUTAL) is the outcome of an extensive working process undertaken by the Working Group on Gender Statistics of the Statistical Conference of the Americas (SCA) to meet the need of Latin American and Caribbean countries for a gender-sensitive instrument appropriate to the regional context that could be used to harmonize and standardize time-use surveys and produce statistics in this area.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Pneumoperitoneum during laparoscopy results in transient oliguria and decreased glomerular filtration and renal blood flow. The presence of oliguria and elevated serum creatinine is suggestive of acute renal injury. Serum cystatin C has been described as a new marker for the detection of this type of injury. In this study, our aim was to compare the glomerular filtration rate estimated using cystatin C levels with the rate estimated using serum creatinine in patients with normal renal function who were undergoing laparoscopic surgery. METHODS: In total, 41 patients undergoing laparoscopic cholecystectomy or hiatoplasty were recruited for the study. Blood samples were collected at three time intervals: first, before intubation (T1); second, 30 minutes after the establishment of pneumoperitoneum (T2); and third, 30 minutes after deflation of the pneumoperitoneum (T3). These blood samples were then analyzed for serum cystatin C, creatinine, and vasopressin. The Larsson formula was used to calculate the glomerular filtration rate based on the serum cystatin C levels, and the Cockcroft-Gault formula was used to calculate the glomerular filtration rate according to the serum creatinine levels. RESULTS: Serum cystatin C levels increased during the study (T1 = T2T3; p<0.05). The calculated eGlomerular filtration rate-Larsson decreased, whereas the eGlomerular filtration rate-Cockcroft-Gault increased. There was no correlation between cystatin C and serum creatinine. Additionally, Pearson's analysis showed a better correlation between serum cystatin C and the eGlomerular filtration rate than between serum creatinine and the eGlomerular filtration rate. CONCLUSION: This study demonstrates that serum cystatin C is a more sensitive indicator of changes in the glomerular filtration rate than serum creatinine is in patients with normal renal function who are undergoing laparoscopic procedures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The primary health care has been recognized as one of the key components of an effective health system. In its most developed form, the primary health care is the first contact with the health system and the site responsible for the organization of health care over time: individuals, their families and the general population; seeks to provide balance between the two goals of a national health system, which are improving the health of the population and provide equitable distribution of resources. Hospitalizations for primary care sensitive conditions (HPCSC) may be associated with deficiencies of service coverage primary health care or its effectiveness. Hospitalization rates can and should represent a warning sign, triggering mechanisms for analysis and search for explanations for these problems. The use of hospitalization data for HPCSC can serve as indicators of inequality in the health system, contributing to the evaluation of the deployment and implementation of health policies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new selective sensor based on molecularly imprinted polymers (MIPs) was developed for the determination of hexazinone (HXZ) in environmental samples. MIPs were synthesized using a non-covalent approach, and selection of the monomers employed in the polymerization reaction was carried out by molecular modeling. Three functional monomers with high (2-vinylpyridine (MP17)) and intermediate (methacrylic acid (MP12) and acrylamide (MP5)) energies of binding to the template (HXZ) were selected for preparation of the MIPs, in order to conduct comparative studies and validate the theoretical data. For sensor construction, carbon pastes were modified with each MIP or NIP (non-imprinted polymer), and HXZ determination was performed using differential pulse adsorptive cathodic stripping voltammetry (DPAdCSV). All parameters affecting the sensor response were optimized. In HCl at pH 2.5, the sensor prepared with MP17 (5% w/w in the paste) showed a dynamic linear range between 1.9 × 10−11 and 1.1 × 10−10 mol L−1, and a detection limit of 2.6 × 10−12 mol L−1, under the following conditions: accumulation time of 200 s at a potential of −0.5V, scan rate of 50 mVs−1, pulse amplitude of 60 mV, and pulse width of 50 ms. The sensor was selective in the presence of other similar compounds, and was successfully applied to the analysis of HXZ in river water samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A montmorillonite from Wyoming-USA was used to prepare an organo-clay complex, named 2-thiazoline-2-thiol-hexadecyltrimethylammonium-clay (TZT-HDTA-clay), for the purpose of the selective adsorption of the heavy metals ions and possible use as a chemically modified carbon paste electrode (CMCPE). Adsorption isotherms of Hg 2+, Pb 2+, Cd 2+, Cu 2+, and Zn 2+ from aqueous solutions as a function of the pH were studied at 298 K. Conditions for quantitative retention and elution were established for each metal by batch and column methods. The organo-clay complex was very selective to Hg(II) in aqueous solution in which other metals and ions were also present. The accumulation voltammetry of Hg(II) was studied at a carbon paste electrode chemically modified with this material. The mercury response was evaluated with respect to the pH, electrode composition, preconcentration time, mercury concentration, cleaning solution, possible interferences and other variables. A carbon paste electrode modified by TZT-HDTA-clay showed two peaks: one cathodic peak at about 0.0 V and an anodic peak at 0.25 V, scanning the potential from -0.2 to 0.8 V (0.05 M KNO 3 vs. Ag/AgCl). The anodic peak at 0.25 V presents excellent selectivity for Hg(II) ions in the presence of foreign ions. The detection limit was estimated as 0.1 μg L -1. The precision of determination was satisfactory for the respective concentration level. 2005 © The Japan Society for Analytical Chemistry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The conditioned rewarding effects of novelty compete with those of cocaine for control over choice behavior using a place conditioning task. The purpose of the present study was to use multiple doses of cocaine to determine the extent of this competition and to determine whether novelty’s impact on cocaine reward was maintained over an abstinence period. In Experiment 1, rats were conditioned with cocaine (7.5, 20, or 30 mg/kg ip) to prefer one side of an unbiased place conditioning apparatus relative to the other. In a subsequent phase, all rats received alternating daily confinements to the previously cocaine paired and unpaired sides of the apparatus. During this phase, half the rats had access to a novel object on their initially unpaired side; the remaining rats did not receive objects. The ability of novelty to compete with cocaine in a drug free and cocaine challenge test was sensitive to cocaine dose. In Experiment 2, a place preference was established with 10 mg/kg cocaine and testing occurred after 1, 14, or 28 day retention intervals. Findings indicate that choice behaviors mediated by cocaine conditioning are reduced with the passing of time. Taken together, competition between cocaine and novelty conditioned rewards are sensitive to drug dose and retention interval.