983 resultados para test cases generator
Resumo:
SUMMARY Leptospirosis is a febrile disease with a typically underestimated global incidence, especially in regions where dengue is endemic. Therefore, it is difficult to accurately determine the number of leptospirosis cases in these areas, which contributes to significant under-reporting this disease. In this study, we estimated the number of possible leptospirosis cases among dengue-like cases that were reported during 2008, 2010, and 2012 in the city of Fortaleza, northeast Brazil. Patients were evaluated for dengue and leptospirosis using immunoenzymatic tests for IgM antibodies that were specific to each pathogen. Among the suspected cases of dengue that resulted as negative in laboratory tests, 10.8% (2008), 19.2% (2010), and 30.8% (2012) were confirmed to be leptospirosis. Considering the cases reported by the surveillance authority as dengue that were subsequently discarded based on the laboratory test results, we estimate that the number of actual leptospirosis cases may be 26 to 49 times higher than those diagnosed and reported by the Health Services. Furthermore, we believe that approximately 20% of dengue-like cases may be leptospirosis cases in areas where the two diseases are endemic.
Resumo:
A two year follow-up of the first two volunteers vaccinated icith the live PF Trypanosoma cruzi strain demonstrated that the parasitological and clinical test were negative during and after that period. Of the serological tests employed, the CFT presented, in only one case, conflicting results, particulary in one laboratory and among different laboratories. However negative results were greater than all doubtful and positive one combined. The IFT icere negative in both patients. Some comments are made about the sensibility and specificity of these tests. The author concluded that the vaccine, in spite of the very large dose used in these cases, seems to be safe for human beings.
Resumo:
This study evaluated serum protein fractions, HDL-cholesterol, total immunoglobulin G and total immunoglobulin E levels in patients with acute and chronic paracoccidioidomycosis, by means of electrophoresis, enzymatic reaction and immunoenzymatic assay. The results demonstrated elevated levels of total immunoglobulin G, total immunoglobulin E, alpha-2 and gamma-globulins, which were more evident in acute than in chronic PCM, but no increase in HDL-cholesterol levels. There was a correlation between the levels of total immunoglobulin E and gamma-globulins and the alpha-2 and beta-globulin fractions in the acute form and between beta and gamma-globulins in both the acute and the chronic form. In conclusion, changes in total immunoglobulin G and immunoglobulin E levels and in the electrophoretic profile may be important markers for the prognosis and therapeutic follow-up of PCM cases, especially because protein electrophoresis is a simple laboratory test that can be applied when specific PCM serological tests are not available. In addition, levels of the gamma-globulin fraction greater than 2.0g/dl may suggest that the patient is developing a more severe form of PCM.
Resumo:
INTRODUCTION: HTLV-1/2 screening among blood donors commonly utilizes an enzyme-linked immunosorbent assay (EIA), followed by a confirmatory method such as Western blot (WB) if the EIA is positive. However, this algorithm yields a high rate of inconclusive results, and is expensive. METHODS: Two qualitative real-time PCR assays were developed to detect HTLV-1 and 2, and a total of 318 samples were tested (152 blood donors, 108 asymptomatic carriers, 26 HAM/TSP patients and 30 seronegative individuals). RESULTS: The sensitivity and specificity of PCR in comparison with WB results were 99.4% and 98.5%, respectively. PCR tests were more efficient for identifying the virus type, detecting HTLV-2 infection and defining inconclusive cases. CONCLUSIONS: Because real-time PCR is sensitive and practical and costs much less than WB, this technique can be used as a confirmatory test for HTLV in blood banks, as a replacement for WB.
Resumo:
INTRODUCTION: The diagnosis of dengue and the differentiation between primary and secondary infections are important for monitoring the spread of the epidemic and identifying the risk of severe forms of the disease. The detection of immunoglobulin (Ig)M and IgG antibodies is the main technique for the laboratory diagnosis of dengue. The present study assessed the application of a rapid test for dengue concerning detection of new cases, reinfection recognition, and estimation of the epidemic attack rate. METHODS: This was a retrospective, cross-sectional, descriptive study on dengue using the Fortaleza Health Municipal Department database. The results from 1,530 tested samples, from 2005-2006, were compared with data from epidemiological studies of dengue outbreaks in 1996, 2003, and 2010. RESULTS: The rapid test confirmed 52% recent infections in the tested patients with clinical suspicion of dengue: 40% detected using IgM and 12% of new cases using IgG in the non-reactive IgM results. The positive IgM plus negative IgG (IgM+ plus IgG-) results showed that 38% of those patients had a recent primary dengue infection, while the positive IgG plus either positive or negative IgM (IgG+ plus IgM+/-) results indicated that 62% had dengue for at least a second time (recent secondary infections). This proportion of reinfections permitted us to estimate the attack rate as >62% of the population sample. CONCLUSIONS: The rapid test for dengue has enhanced our ability to detect new infections and to characterize them into primary and secondary infections, permitting the estimation of the minimal attack rate for a population during an outbreak.
Resumo:
The occurrence of tuberculosis with first-line multidrug resistance leads to the use of alternative medications, often at higher costs, longer treatment periods, and greater clinical complexity. Here, we report 3 patients with multidrug-resistant tuberculosis. One patient with human immunodeficiency virus died before the sensitivity test was performed. The early diagnosis of multidrug-resistant tuberculosis and appropriate treatment should be priorities of the National Tuberculosis Control Program in order to break the chain of transmission. In addition, the possibility of substituting the proportion method with more modern and faster techniques should be urgently evaluated.
Possible artemisinin-based combination therapy-resistant malaria in Nigeria: a report of three cases
Resumo:
Artemisinin-based combination therapy-resistant malaria is rare in Sub-Saharan Africa. The World Health Organization identifies monitoring and surveillance using day-3 parasitaemia post-treatment as the standard test for identifying suspected artemisinin resistance. We report three cases of early treatment failure due to possible artemisinin-based combination therapy-resistant Plasmodium falciparum malaria. All cases showed adequate clinical and parasitological responses to quinine. This study reveals a need to re-evaluate the quality and efficacy of artemisinin-based combination therapy agents in Nigeria and Sub-Saharan Africa.
Resumo:
Introduction Rapid diagnostic tests (RDTs) may improve the early detection of visceral leishmaniasis (VL), but their real-world performance requires additional study. Therefore, we evaluated the performance of an rK39-based RDT (Kalazar Detect™) for the detection of VL in an endemic, large urban area. Methods Data were collected from a registry of rK39 RDT performed at 11 emergency care units in Belo Horizonte, Brazil, and from a national database of reportable communicable diseases of the Sistema de Informação de Agravos de Notificação (SINAN). Results The rapid rK39 test was performed in 476 patients, with 114 (23.9%) positive results. The analysis of rK39 RDT performance was based on 381 (80%) cases reported to the SINAN database, of which 145 (38.1%) were confirmed cases. Estimates for sensitivity and specificity were 72.4% (95% CI: 64.6-79%) and 99.6% (95%CI: 97.6-99.9%), respectively. Positive and negative predictive values were estimated at 99.1% (95%CI: 94.9-99.8%) and 85.5% (95%CI: 80.8-89.1%), respectively. In addition, close agreement between the rK39 RDT and indirect immunofluorescence was observed. Conclusions In summary, the rK39 RDT showed a high specificity but only moderate sensitivity. In endemic areas for VL, treatment may be considered in cases with clinical manifestations and a positive rK39 RDT, but those with a negative test should be subjected to further investigation.
Resumo:
Abstract: INTRODUCTION: Despite multidrug therapy, leprosy remains a public health issue. The intradermal Bacillus Calmette-Guérin (BCG) vaccine, Mitsuda test (lepromin skin test), and anti-phenolic glycolipid I (PGL-I) serology are widely used in leprosy studies and have shown great epidemiological value. METHODS: This longitudinal study evaluated the relative risks and benefits of these three tools by comparing results observed in household contacts (HHCs) of leprosy patients who developed leprosy with those of HHCs who did not in a population of 2,992 individuals monitored during a 10-year period. RESULTS : Seventy-five (2.5%) new leprosy cases were diagnosed, including 28 (0.9%) co-prevalent cases. Therefore, for the risk-benefit assessment, 47 (1.6%) HHCs were considered as truly diagnosed during follow-up. The comparison between healthy and affected contacts demonstrated that not only did BCG vaccination increase protection, but boosters also increased to 95% relative risk (RR) reduction when results for having two or more scars were compared with having no scars [RR, 0.0459; 95% confidence interval (CI), 0.006-0.338]. Similarly, Mitsuda reactions >7mm in induration presented 7-fold greater protection against disease development compared to reactions of 0-3mm (RR, 0.1446; 95% CI, 0.0566-0.3696). In contrast, anti-PGL-I ELISA seropositivity indicated a 5-fold RR increase for disease outcome (RR, 5.688; 95% CI, 3.2412-9.9824). The combined effect of no BCG scars, Mitsuda reaction of <7mm, and seropositivity to anti-PGL-I increased the risk for leprosy onset 8-fold (RR, 8.109; 95% CI, 5.1167-12.8511). CONCLUSIONS: The adoption of these combined assays may impose measures for leprosy control strategies.
Resumo:
INTRODUCTION: Friedreich's ataxia is a neurodegenerative disorder whose clinical diagnostic criteria for typical cases basically include: a) early age of onset (< 20 or 25 years), b) autosomal recessive inheritance, c) progressive ataxia of limbs and gait, and d) absence of lower limb tendon reflexes. METHODS: We studied the frequency and the size of expanded GAA and their influence on neurologic findings, age at onset, and disease progression in 25 Brazilian patients with clinical diagnosis of Friedreich's ataxia - 19 typical and 6 atypical - using a long-range PCR test. RESULTS: Abnormalities in cerebellar signs, in electrocardiography, and pes cavus occurred more frequently in typical cases; however, plantar response and speech were more frequently normal in this group when the both typical and atypical cases were compared. Homozygous GAA expansion repeats were detected in 17 cases (68%) - all typical cases. In 8 patients (32%) (6 atypical and 2 typical), no expansion was observed, ruling out the diagnosis of Friedreich's ataxia. In cases with GAA expansions, foot deformity, cardiac abnormalities, and some neurologic findings occurred more frequently; however, abnormalities in cranial nerves and in tomographic findings were detected less frequently than in patients without GAA expansions. DISCUSSION: Molecular analysis was imperative for the diagnosis of Friedreich's ataxia, not only for typical cases but also for atypical ones. There was no genotype-phenotype correlation. Diagnosis based only on clinical findings is limited; however, it aids in better screening for suspected cases that should be tested. Evaluation for vitamin E deficiency is recommended, especially in cases without GAA expansion.
Resumo:
PURPOSE: To review the medical literature regarding the histopathologic and biochemical liver test abnormalities in chronic asymptomatic or oligosymptomatic alcoholics. METHODS: Review of articles in the MEDLINE and LILACS databases regarding serum levels and prevalence of alterations in aspartate-aminotransferase, alanine-aminotransferase, alkaline phosphatase, and total bilirubin, in relation to liver histopathology, with or without discrimination of types of histopathologic alteration. RESULTS: Global mean prevalence rates of aspartate-aminotransferase and alanine-aminotransferase alterations were 86.3% and 51.1%; in cases with steatosis they were 79.1% and 38.5%; and in cases of hepatitis, 90.1% and 58%. In all studies, prevalence rates of aspartate-aminotransferase alterations were significantly higher with lower variability than those of alanine-aminotransferase. Mean aspartate-aminotransferase levels were higher than 2N (N is the upper normal limit of the method employed) in all cases with hepatitis histopathology, while those of alanine-aminotransferase were 1.48N, in the same cases. Prevalence of alkaline phosphatase and total bilirubin abnormalities were 74.5% and 74.9% globally; in cases of steatosis, they were 70.9% and 67.9%; and in cases of hepatitis, 75.9% and 77.7%. Mean alkaline phosphatase levels were above the upper normal limit in all cases, but those of total bilirubin were above normal in 4 of 7 hepatitis studies. CONCLUSIONS: Prevalence of aspartate-aminotransferase alteration was consistently related to presence of histopathologic abnormalities; an enzyme level higher than 2N suggests the diagnosis of alcoholic hepatitis.
Resumo:
Background: Studies have demonstrated the diagnostic accuracy and prognostic value of physical stress echocardiography in coronary artery disease. However, the prediction of mortality and major cardiac events in patients with exercise test positive for myocardial ischemia is limited. Objective: To evaluate the effectiveness of physical stress echocardiography in the prediction of mortality and major cardiac events in patients with exercise test positive for myocardial ischemia. Methods: This is a retrospective cohort in which 866 consecutive patients with exercise test positive for myocardial ischemia, and who underwent physical stress echocardiography were studied. Patients were divided into two groups: with physical stress echocardiography negative (G1) or positive (G2) for myocardial ischemia. The endpoints analyzed were all-cause mortality and major cardiac events, defined as cardiac death and non-fatal acute myocardial infarction. Results: G2 comprised 205 patients (23.7%). During the mean 85.6 ± 15.0-month follow-up, there were 26 deaths, of which six were cardiac deaths, and 25 non-fatal myocardial infarction cases. The independent predictors of mortality were: age, diabetes mellitus, and positive physical stress echocardiography (hazard ratio: 2.69; 95% confidence interval: 1.20 - 6.01; p = 0.016). The independent predictors of major cardiac events were: age, previous coronary artery disease, positive physical stress echocardiography (hazard ratio: 2.75; 95% confidence interval: 1.15 - 6.53; p = 0.022) and absence of a 10% increase in ejection fraction. All-cause mortality and the incidence of major cardiac events were significantly higher in G2 (p < 0. 001 and p = 0.001, respectively). Conclusion: Physical stress echocardiography provides additional prognostic information in patients with exercise test positive for myocardial ischemia.
Resumo:
Wireless mesh networks present an attractive communication solution for various research and industrial projects. However, in many cases, the appropriate preliminary calculations which allow predicting the network behavior have to be made before the actual deployment. For such purposes, network simulation environments emulating the real network operation are often used. Within this paper, a behavior comparison of real wireless mesh network (based on 802.11s amendment) and the simulated one has been performed. The main objective of this work is to measure performance parameters of a real 802.11s wireless mesh network (average UDP throughput and average one-way delay) and compare the derived results with characteristics of a simulated wireless mesh network created with the NS-3 network simulation tool. Then, the results from both networks are compared and the corresponding conclusion is made. The corresponding results were derived from simulation model and real-worldtest-bed, showing that the behavior of both networks is similar. It confirms that the NS-3 simulation model is accurate and can be used in further research studies.
Resumo:
This paper proposes a novel way of testing exogeneity of an explanatory variable without any parametric assumptions in the presence of a "conditional" instrumental variable. A testable implication is derived that if an explanatory variable is endogenous, the conditional distribution of the outcome given the endogenous variable is not independent of its instrumental variable(s). The test rejects the null hypothesis with probability one if the explanatory variable is endogenous and it detects alternatives converging to the null at a rate n..1=2:We propose a consistent nonparametric bootstrap test to implement this testable implication. We show that the proposed bootstrap test can be asymptotically justi.ed in the sense that it produces asymptotically correct size under the null of exogeneity, and it has unit power asymptotically. Our nonparametric test can be applied to the cases in which the outcome is generated by an additively non-separable structural relation or in which the outcome is discrete, which has not been studied in the literature.
Resumo:
An indirect haemagglutination (IH) test is described for the detection of Clostridium perfringens type A enterotoxin, produced by strains isolated from human cases of food poisoning and from contaminated food. Though no strict relationship could be observed between titers in the IH test and the time it took mice to die from the intravenous inoculation of mice (IIM), results of the supernatants examined by both methods demonstrated that the IH test was more sensitive than the ILM one. No unspecific reaction was obtanined int he IH wirh a negative control and the inhibitions of the IH and IIM tests by specific antiserum against C. perfringens enterotoxin showed that the IH test is very spcific. The IH assay is recommended for its sensitivity and easy performance by less-equipped laboratories, by these and other data.