1000 resultados para statistical emission


Relevância:

20.00% 20.00%

Publicador:

Resumo:

2002 edition

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We explore in depth the validity of a recently proposed scaling law for earthquake inter-event time distributions in the case of the Southern California, using the waveform cross-correlation catalog of Shearer et al. Two statistical tests are used: on the one hand, the standard two-sample Kolmogorov-Smirnov test is in agreement with the scaling of the distributions. On the other hand, the one-sample Kolmogorov-Smirnov statistic complemented with Monte Carlo simulation of the inter-event times, as done by Clauset et al., supports the validity of the gamma distribution as a simple model of the scaling function appearing on the scaling law, for rescaled inter-event times above 0.01, except for the largest data set (magnitude greater than 2). A discussion of these results is provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the "DSM-IV(R)" was published in 1994, we've seen many advances in our knowledge of psychiatric illness. This "Text Revision" incorporates information culled from a comprehensive literature review of research about mental disorders published since "DSM-IV(R)" was completed in 1994. Updated information is included about the associated features, culture, age, and gender features, prevalence, course, and familial pattern of mental disorders. The "DSM-IV-TR(R)" brings this essential diagnostic tool up-to-date, to promote effective diagnosis, treatment, and quality of care. Now you can get all the essential diagnostic information you rely on from the "DSM-IV(R)" along with important updates not found in the 1994 edition. Stay current with important updates to the "DSM-IV-TR(R)": Benefit from new research into Schizophrenia, Asperger's Disorder, and other conditions Utilize additional information about the epidemiology and other facets of DSM conditions Update ICD-9-CM codes implemented since 1994 (including Conduct Disorder, Dementia, Somatoform Disorders) DSM-IV-TR(R), the handheld version of the "Diagnostic and Statistical Manual of Mental Disorders, "Fourth Edition, Text Revision, is now available for both Palm OS and PocketPC handhelds. This Text Revision incorporates information culled from a comprehensive literature review of research about mental disorders and includes associated features, culture, age, and gender features, prevalence, course, and familial pattern of mental disorders.This resource was contributed by The National Documentation Centre on Drug Use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Boundaries for delta, representing a "quantitatively significant" or "substantively impressive" distinction, have not been established, analogous to the boundary of alpha, usually set at 0.05, for the stochastic or probabilistic component of "statistical significance". To determine what boundaries are being used for the "quantitative" decisions, we reviewed pertinent articles in three general medical journals. For each contrast of two means, contrast of two rates, or correlation coefficient, we noted the investigators' decisions about stochastic significance, stated in P values or confidence intervals, and about quantitative significance, indicated by interpretive comments. The boundaries between impressive and unimpressive distinctions were best formed by a ratio of greater than or equal to 1.2 for the smaller to the larger mean in 546 comparisons, by a standardized increment of greater than or equal to 0.28 and odds ratio of greater than or equal to 2.2 in 392 comparisons of two rates; and by an r value of greater than or equal to 0.32 in 154 correlation coefficients. Additional boundaries were also identified for "substantially" and "highly" significant quantitative distinctions. Although the proposed boundaries should be kept flexible, indexes and boundaries for decisions about "quantitative significance" are particularly useful when a value of delta must be chosen for calculating sample size before the research is done, and when the "statistical significance" of completed research is appraised for its quantitative as well as stochastic components.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laser desorption ionisation mass spectrometry (LDI-MS) has demonstrated to be an excellent analytical method for the forensic analysis of inks on a questioned document. The ink can be analysed directly on its substrate (paper) and hence offers a fast method of analysis as sample preparation is kept to a minimum and more importantly, damage to the document is minimised. LDI-MS has also previously been reported to provide a high power of discrimination in the statistical comparison of ink samples and has the potential to be introduced as part of routine ink analysis. This paper looks into the methodology further and evaluates statistically the reproducibility and the influence of paper on black gel pen ink LDI-MS spectra; by comparing spectra of three different black gel pen inks on three different paper substrates. Although generally minimal, the influences of sample homogeneity and paper type were found to be sample dependent. This should be taken into account to avoid the risk of false differentiation of black gel pen ink samples. Other statistical approaches such as principal component analysis (PCA) proved to be a good alternative to correlation coefficients for the comparison of whole mass spectra.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Discriminant analysis was used to identify eggs of Capillaria spp. at specific level found in organic remains from an archaeological site in Patagonia, Argentina, dated of 6,540 ± 110 years before present. In order to distinguish eggshell morphology 149 eggs were measured and grouped into four arbitrary subsets. The analysis used on egg width and length discriminated them into different morphotypes (Wilks' lambda = 0.381, p < 0.05). The correlation analysis suggests that width was the most important variable to discriminate among the Capillaria spp. egg morphotypes (Pearson coefficient = 0.950, p < 0.05). The study of eggshell patterns, the relative frequency in the sample, and the morphometric data allowed us to correlate the four morphotypes with Capillaria species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to obtain a high-resolution Pleistocene stratigraphy, eleven continuouslycored boreholes, 100 to 220m deep were drilled in the northern part of the PoPlain by Regione Lombardia in the last five years. Quantitative provenanceanalysis (QPA, Weltje and von Eynatten, 2004) of Pleistocene sands was carriedout by using multivariate statistical analysis (principal component analysis, PCA,and similarity analysis) on an integrated data set, including high-resolution bulkpetrography and heavy-mineral analyses on Pleistocene sands and of 250 majorand minor modern rivers draining the southern flank of the Alps from West toEast (Garzanti et al, 2004; 2006). Prior to the onset of major Alpine glaciations,metamorphic and quartzofeldspathic detritus from the Western and Central Alpswas carried from the axial belt to the Po basin longitudinally parallel to theSouthAlpine belt by a trunk river (Vezzoli and Garzanti, 2008). This scenariorapidly changed during the marine isotope stage 22 (0.87 Ma), with the onset ofthe first major Pleistocene glaciation in the Alps (Muttoni et al, 2003). PCA andsimilarity analysis from core samples show that the longitudinal trunk river at thistime was shifted southward by the rapid southward and westward progradation oftransverse alluvial river systems fed from the Central and Southern Alps.Sediments were transported southward by braided river systems as well as glacialsediments transported by Alpine valley glaciers invaded the alluvial plain.Kew words: Detrital modes; Modern sands; Provenance; Principal ComponentsAnalysis; Similarity, Canberra Distance; palaeodrainage

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The preceding two editions of CoDaWork included talks on the possible considerationof densities as infinite compositions: Egozcue and D´ıaz-Barrero (2003) extended theEuclidean structure of the simplex to a Hilbert space structure of the set of densitieswithin a bounded interval, and van den Boogaart (2005) generalized this to the setof densities bounded by an arbitrary reference density. From the many variations ofthe Hilbert structures available, we work with three cases. For bounded variables, abasis derived from Legendre polynomials is used. For variables with a lower bound, westandardize them with respect to an exponential distribution and express their densitiesas coordinates in a basis derived from Laguerre polynomials. Finally, for unboundedvariables, a normal distribution is used as reference, and coordinates are obtained withrespect to a Hermite-polynomials-based basis.To get the coordinates, several approaches can be considered. A numerical accuracyproblem occurs if one estimates the coordinates directly by using discretized scalarproducts. Thus we propose to use a weighted linear regression approach, where all k-order polynomials are used as predictand variables and weights are proportional to thereference density. Finally, for the case of 2-order Hermite polinomials (normal reference)and 1-order Laguerre polinomials (exponential), one can also derive the coordinatesfrom their relationships to the classical mean and variance.Apart of these theoretical issues, this contribution focuses on the application of thistheory to two main problems in sedimentary geology: the comparison of several grainsize distributions, and the comparison among different rocks of the empirical distribution of a property measured on a batch of individual grains from the same rock orsediment, like their composition

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: We aim to investigate the possibility of using 18F-positron emission tomography/computer tomography (PET-CT) to predict the histopathologic response in locally advanced rectal cancer (LARC) treated with preoperative chemoradiation (CRT). Methods: The study included 50 patients with LARC treated with preoperative CRT. All patients were evaluated by PET-CT before and after CRT, and results were compared to histopathologic response quantified by tumour regression grade (patients with TRG 1-2 being defined as responders and patients with grade 3-5 as non-responders). Furthermore, the predictive value of metabolic imaging for pathologic complete response (ypCR) was investigated. Results: Responders and non-responders showed statistically significant differences according to Mandard's criteria for maximum standardized uptake value (SUVmax) before and after CRT with a specificity of 76,6% and a positive predictive value of 66,7%. Furthermore, SUVmax values after CRT were able to differentiate patients with ypCR with a sensitivity of 63% and a specificity of 74,4% (positive predictive value 41,2% and negative predictive value 87,9%); This rather low sensitivity and specificity determined that PET-CT was only able to distinguish 7 cases of ypCR from a total of 11 patients. Conclusions: We conclude that 18-F PET-CT performed five to seven weeks after the end of CRT can visualise functional tumour response in LARC. In contrast, metabolic imaging with 18-F PET-CT is not able to predict patients with ypCR accurately

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the diagnostic value and image quality of CT with filtered back projection (FBP) compared with adaptive statistical iterative reconstructed images (ASIR) in body stuffers with ingested cocaine-filled packets.Methods and Materials: Twenty-nine body stuffers (mean age 31.9 years, 3 women) suspected for ingestion of cocaine-filled packets underwent routine-dose 64-row multidetector CT with FBP (120kV, pitch 1.375, 100-300 mA and automatic tube current modulation (auto mA), rotation time 0.7sec, collimation 2.5mm), secondarily reconstructed with 30 % and 60 % ASIR. In 13 (44.83%) out of the body stuffers cocaine-filled packets were detected, confirmed by exact analysis of the faecal content including verification of the number (range 1-25). Three radiologists independently and blindly evaluated anonymous CT examinations (29 FBP-CT and 68 ASIR-CT) for the presence and number of cocaine-filled packets indicating observers' confidence, and graded them for diagnostic quality, image noise, and sharpness. Sensitivity, specificity, area under the receiver operating curve (ROC) Az and interobserver agreement between the 3 radiologists for FBP-CT and ASIR-CT were calculated.Results: The increase of the percentage of ASIR significantly diminished the objective image noise (p<0.001). Overall sensitivity and specificity for the detection of the cocaine-filled packets were 87.72% and 76.15%, respectively. The difference of ROC area Az between the different reconstruction techniques was significant (p= 0.0101), that is 0.938 for FBP-CT, 0.916 for 30 % ASIR-CT, and 0.894 for 60 % ASIR-CT.Conclusion: Despite the evident image noise reduction obtained by ASIR, the diagnostic value for detecting cocaine-filled packets decreases, depending on the applied ASIR percentage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Observations in daily practice are sometimes registered as positive values larger then a given threshold α. The sample space is in this case the interval (α,+∞), α & 0, which can be structured as a real Euclidean space in different ways. This fact opens the door to alternative statistical models depending not only on the assumed distribution function, but also on the metric which is considered as appropriate, i.e. the way differences are measured, and thus variability

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is a first draft of the principle of statistical modelling on coordinates. Several causes —which would be long to detail—have led to this situation close to the deadline for submitting papers to CODAWORK’03. The main of them is the fast development of the approach along thelast months, which let appear previous drafts as obsolete. The present paper contains the essential parts of the state of the art of this approach from my point of view. I would like to acknowledge many clarifying discussions with the group of people working in this field in Girona, Barcelona, Carrick Castle, Firenze, Berlin, G¨ottingen, and Freiberg. They have given a lot of suggestions and ideas. Nevertheless, there might be still errors or unclear aspects which are exclusively my fault. I hope this contribution serves as a basis for further discussions and new developments

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Positron emission tomography (PET) during the cold pressor test (CPT) has been used to assess endothelium-dependent coronary vasoreactivity, a surrogate marker of cardiovascular events. However, its use remains limited by cardiac PET availability. As multidetector computed tomography (MDCT) is more widely available, we aimed to develop a measurement of endothelium-dependent coronary vasoreactivity with MDCT and similar radiation burden as with PET. METHODS AND RESULTS: A study group of 18 participants without known cardiovascular risk factor (9F/9M; age 60±6 years) underwent cardiac PET with (82)Rb and unenhanced ECG-gated MDCT within 4h, each time at rest and during CPT. The relation between absolute myocardial blood flow (MBF) response to CPT by PET (ml·min(-1)·g(1)) and relative changes in MDCT-measured coronary artery surface were assessed using linear regression analysis and Spearman's correlation. MDCT and PET/CT were analyzed in all participants. Hemodynamic conditions during CPT at MDCT and PET were similar (P>0.3). Relative changes in coronary artery surface because of CPT (2.0-21.2%) correlated to changes in MBF (-0.10-0.52ml·min(-1)·g(1)) (ρ=0.68, P=0.02). Effective dose was 1.3±0.2mSv for MDCT and 3.1mSv for PET/CT. CONCLUSIONS: Assessment of endothelium-dependent coronary vasoreactivity using MDCT CPT appears feasible. Because of its wider availability, shorter examination time and similar radiation burden, MDCT could be attractive in clinical research for coronary status assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Functional imaging studies of addiction following protracted abstinence have not been systematically conducted to look at the associations between severity of use of different drugs and brain dysfunction. Findings from such studies may be relevant to implement specific interventions for treatment. The aim of this study was to examine the association between resting-state regional brain metabolism (measured with 18F-fluorodeoxyglucose Positron Emission Tomography (FDG-PET) and the severity of use of cocaine, heroin, alcohol, MDMA and cannabis in a sample of polysubstance users with prolonged abstinence from all drugs used. METHODS Our sample consisted of 49 polysubstance users enrolled in residential treatment. We conducted correlation analyses between estimates of use of cocaine, heroin, alcohol, MDMA and cannabis and brain metabolism (BM) (using Statistical Parametric Mapping voxel-based (VB) whole-brain analyses). In all correlation analyses conducted for each of the drugs we controlled for the co-abuse of the other drugs used. RESULTS The analysis showed significant negative correlations between severity of heroin, alcohol, MDMA and cannabis use and BM in the dorsolateral prefrontal cortex (DLPFC) and temporal cortex. Alcohol use was further associated with lower metabolism in frontal premotor cortex and putamen, and stimulants use with parietal cortex. CONCLUSIONS Duration of use of different drugs negatively correlated with overlapping regions in the DLPFC, whereas severity of cocaine, heroin and alcohol use selectively impact parietal, temporal, and frontal-premotor/basal ganglia regions respectively. The knowledge of these associations could be useful in the clinical practice since different brain alterations have been associated with different patterns of execution that may affect the rehabilitation of these patients.