876 resultados para software quality assurance


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Due to growing urbanization and industrialization, the environment is suffering from pollution of rivers, degradation of soils and deteriorated air quality. Quality indices appear to be useful to evaluate the conditions of these media. The aim of this study was the development of a water quality index using a fuzzy inference system, since such an approach has proved advantageous in addressing problems that are subjective by nature or for which the data are uncertain. The methodology employed was based on this inference system, and considered the nine water quality parameters employed by CETESB (Companhia de Tecnologia de Saneamento Ambiental, São Paulo, Brazil) to evaluate water quality. After assessment of the data using the index, a comparison was made with the WQI (Water Quality Index), which is used for the monitoring of various water bodies, including in the study region. The results obtained using the index developed on the basis of fuzzy inference were found to be more useful than those derived from the method currently used by CETESB, since losses and/or omissions concerning individual parameters were minimized. © 2010 IEEE.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Soil is an essential resource for life and its properties are susceptible to be modified by tillage systems. The impact of management practices on soil functions can be assessed through a soil quality index. It is interesting to assess soil quality in different soil types. Therefore, the aim of this study was to determine the soil quality index of a Paleudult under different management conditions and sunflower culture. The experiment was carried out in Botucatu (SP, Brazil), in an 11-year non-tilled area used for growing soybean and maize during summer and black oat or triticale in winter. Four management systems were considered: no-tillage with a hoe planter (NTh), no-tillage with a double-disk planter (NTd), reduced tillage (RT) and conventional tillage (CT). Soil samples were taken from the planting lines at harvest time. To determine the soil quality indices, following the methodology proposed by Karlen and Stott (1994), three main soil functions were assessed: soil capacity for root development, water storage capacity of the soil and nutrient supply capacity of the soil. The studied Paleudult was considered a soil with good quality under all the observed management systems. However, the soil quality indices varied between treatments being 0.64, 0.68, 0.86 and 0.79 under NTh, NTd, RT and CT, respectively. Physical attributes such as resistance to penetration and macroporosity increased the soil quality index in RT and CT compared to NTh and NTd. The soil quality indices obtained suggested that the evaluated soil is adequate for sunflower production under our study conditions. In view of the SQI values, RT is the most suitable management for this site since it preserves soil quality and provides an acceptable sunflower yield. © 2011 Elsevier B.V.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The use of the Internet as a means of ensuring greater visibility for products, services and information offered by companies is gaining strength in recent decades. However, it is known that to ensure satisfaction and subsequent virtual customer loyalty, it is necessary to guarantee the quality of the websites, allowing indiscriminate access regardless of the resources used, as well as rapid responses to possible requests. In order to assist this process, this paper presents a set of guidelines for the development of websites having quality characteristics, efficiency and portability as per ISO 9126 norms. An observational analysis of e-commerce websites was done which showed that they are inadequate as to the proposed guidelines, making them difficult to access available content. Therefore, the adoption of the proposed guidelines can greatly contribute to increasing the quality of websites and, consequently, enable quick and effective access regardless of the resources used.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The software industry has become more and more concerned with the appropriate application of activities that composes requirement engineering as a way to improve the quality of its products. In order to support these activities, several computational tools have been available in the market, although it is still possible to find a lack of resources related to some activities. In this context, this paper proposes the inclusion of a module to aid in the requirements specification to a tool called Requirements Elicitation Support Tool. This module allows to specify requirements in accordance with IEEE 830 standard, thus contributing to the documentation of the requirements established for a software system, besides supporting the learning of concepts related to the requirements specification, which improves the skills of users of the tool. © 2012 IEEE.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The software quality represents a more and more important attribute for the survival and growth of software industries. In order to ensure the quality of products manufactured, various practices have been incorporated into the development process. In this context, some successful software organizations have invested in an approach to human resource management, which consists in integrating the management activities with a personal process called Personal Software Process - PSP, which has led to the maintenance of greater discipline and control over all development phases. Given this, this work presents a proposal for integration of techniques set out in the PSP with a web system previously developed, which is called System to Aid Project Management - SAPM.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Colombian Reference National Laboratory, GENES LTDA, have organized and coordinated for the past two years (2009 and 2010) the Quality Control Exercise for laboratories undertaking paternity, maternity and forensic tests with DNA markers. Twenty-two laboratories have participated in 2009, increasing the number to 27 in 2010. Laboratories in Colombia, Brazil, Ecuador, Peru, Dominican Republic and Panama have participated in these exercises. There have been some similarities in the two controls: A practical exercise, three blood samples on FTA cards were sent to each participating laboratory to be genotyped for DNA markers using the routine methodologies in their laboratories; theoretical exercises including optional and obligatory cases. For the theoretical exercises, the participating laboratories should calculate the partial and final PI or BRI (Biological Relationship Index or Paternity Index). Forty-nine and 52 markers were under consensus for 2009 and 2010, respectively, distributed in autosomal, Y and X chromosomes STR. With respect to 2008, 12 and 15 additional markers were under consensus for 2009 and 2010, respectively. The rate of reporting error was 2.9% in 2009 while in 2010, 4.7% error was reported. The Proficiency Test conducted through the Colombian National Reference Laboratory has become a useful tool for quality assurance of all Colombian laboratories and some of Latin America that do DNA testing to establish biological relationships and an excellent opportunity for ongoing training of experts from the region.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In food industry, quality assurance requires low cost methods for the rapid assessment of the parameters that affect product stability. Foodstuffs are complex in their structure, mainly composed by gaseous, liquid and solid phases which often coexist in the same product. Special attention is given to water, concerned as natural component of the major food product or as added ingredient of a production process. Particularly water is structurally present in the matrix and not completely available. In this way, water can be present in foodstuff in many different states: as water of crystallization, bound to protein or starch molecules, entrapped in biopolymer networks or adsorbed on solid surfaces of porous food particles. The traditional technique for the assessment of food quality give reliable information but are destructive, time consuming and unsuitable for on line application. The techniques proposed answer to the limited disposition of time and could be able to characterize the main compositional parameters. Dielectric interaction response is mainly related to water and could be useful not only to provide information on the total content but also on the degree of mobility of this ubiquitous molecule in different complex food matrix. In this way the proposal of this thesis is to answer at this need. Dielectric and electric tool can be used for the scope and led us to describe the complex food matrix and predict food characteristic. The thesis is structured in three main part, in the first one some theoretical tools are recalled to well assess the food parameter involved in the quality definition and the techniques able to reply at the problem emerged. The second part explains the research conducted and the experimental plans are illustrated in detail. Finally the last section is left for rapid method easily implementable in an industrial process.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Magnetic Resonance Spectroscopy (MRS) is an advanced clinical and research application which guarantees a specific biochemical and metabolic characterization of tissues by the detection and quantification of key metabolites for diagnosis and disease staging. The "Associazione Italiana di Fisica Medica (AIFM)" has promoted the activity of the "Interconfronto di spettroscopia in RM" working group. The purpose of the study is to compare and analyze results obtained by perfoming MRS on scanners of different manufacturing in order to compile a robust protocol for spectroscopic examinations in clinical routines. This thesis takes part into this project by using the GE Signa HDxt 1.5 T at the Pavillion no. 11 of the S.Orsola-Malpighi hospital in Bologna. The spectral analyses have been performed with the jMRUI package, which includes a wide range of preprocessing and quantification algorithms for signal analysis in the time domain. After the quality assurance on the scanner with standard and innovative methods, both spectra with and without suppression of the water peak have been acquired on the GE test phantom. The comparison of the ratios of the metabolite amplitudes over Creatine computed by the workstation software, which works on the frequencies, and jMRUI shows good agreement, suggesting that quantifications in both domains may lead to consistent results. The characterization of an in-house phantom provided by the working group has achieved its goal of assessing the solution content and the metabolite concentrations with good accuracy. The goodness of the experimental procedure and data analysis has been demonstrated by the correct estimation of the T2 of water, the observed biexponential relaxation curve of Creatine and the correct TE value at which the modulation by J coupling causes the Lactate doublet to be inverted in the spectrum. The work of this thesis has demonstrated that it is possible to perform measurements and establish protocols for data analysis, based on the physical principles of NMR, which are able to provide robust values for the spectral parameters of clinical use.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Early detection of colorectal cancer through timely follow-up of positive Fecal Occult Blood Tests (FOBTs) remains a challenge. In our previous work, we found 40% of positive FOBT results eligible for colonoscopy had no documented response by a treating clinician at two weeks despite procedures for electronic result notification. We determined if technical and/or workflow-related aspects of automated communication in the electronic health record could lead to the lack of response. METHODS: Using both qualitative and quantitative methods, we evaluated positive FOBT communication in the electronic health record of a large, urban facility between May 2008 and March 2009. We identified the source of test result communication breakdown, and developed an intervention to fix the problem. Explicit medical record reviews measured timely follow-up (defined as response within 30 days of positive FOBT) pre- and post-intervention. RESULTS: Data from 11 interviews and tracking information from 490 FOBT alerts revealed that the software intended to alert primary care practitioners (PCPs) of positive FOBT results was not configured correctly and over a third of positive FOBTs were not transmitted to PCPs. Upon correction of the technical problem, lack of timely follow-up decreased immediately from 29.9% to 5.4% (p<0.01) and was sustained at month 4 following the intervention. CONCLUSION: Electronic communication of positive FOBT results should be monitored to avoid limiting colorectal cancer screening benefits. Robust quality assurance and oversight systems are needed to achieve this. Our methods may be useful for others seeking to improve follow-up of FOBTs in their systems.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introduction To meet the quality standards for high-stakes OSCEs, it is necessary to ensure high quality standardized performance of the SPs involved.[1] One of the ways this can be assured is through the assessment of the quality of SPs` performance in training and during the assessment. There is some literature concerning validated instruments that have been used to assess SP performance in formative contexts but very little related to high stakes contexts.[2], [3], [4]. Content and structure During this workshop different approaches to quality control for SPs` performance, developed in medicine, pharmacy and nursing OSCEs, will be introduced. Participants will have the opportunity to use these approaches in simulated interactions. Advantages and disadvantages of these approaches will be discussed. Anticipated outcomes By the end of this session, participants will be able to discuss the rationale for quality control of SPs` performance in high stakes OSCEs, outline key factors in creating strategies for quality control, identify various strategies for assuring quality control, and reflect on applications to their own practice. Who should attend The workshop is designed for those interested in quality assurance of SP performance in high stakes OSCEs. Level All levels are welcome. References Adamo G. 2003. Simulated and standardized patients in OSCEs: achievements and challenges:1992-2003. Med Teach. 25(3), 262- 270. Wind LA, Van Dalen J, Muijtjens AM, Rethans JJ. Assessing simulated patients in an educational setting: the MaSP (Maastricht Assessment of Simulated Patients). Med Educ 2004, 38(1):39-44. Bouter S, van Weel-Baumgarten E, Bolhuis S. Construction and validation of the Nijmegen Evaluation of the Simulated Patient (NESP): Assessing Simulated Patients' ability to role-play and provide feedback to students. Acad Med: Journal of the Association of American Medical Colleges 2012. May W, Fisher D, Souder D: Development of an instrument to measure the quality of standardized/simulated patient verbal feedback. Med Educ 2012, 2(1).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Sample preparation procedures for AMS measurements of 129I and 127I in environmental materials and some methodological aspects of quality assurance are discussed. Measurements from analyses of some pre-nuclear soil and thyroid gland samples and of a systematic investigation of natural waters in Lower Saxony, Germany, are described. Although the up-to-now lowest 129I/127I ratios in soils and thyroid glands were observed, they are still suspect to contamination since they are significantly higher than the pre-nuclear equilibrium ratio in the marine hydrosphere. A survey on all available 129I/127I isotopic ratios in precipitation shows a dramatic increase until the middle of the 1980s and a stabilization since 1987 at high isotopic ratios of about (3.6–8.3)×10−7. In surface waters, ratios of (57–380)×10−10 are measured while shallow ground waters show with ratios of (1.3–200)×10−10 significantly lower values with a much larger spread. The data for 129I in soils and in precipitation are used to estimate pre-nuclear and modern 129I deposition densities.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The usage of intensity modulated radiotherapy (IMRT) treatments necessitates a significant amount of patient-specific quality assurance (QA). This research has investigated the precision and accuracy of Kodak EDR2 film measurements for IMRT verifications, the use of comparisons between 2D dose calculations and measurements to improve treatment plan beam models, and the dosimetric impact of delivery errors. New measurement techniques and software were developed and used clinically at M. D. Anderson Cancer Center. The software implemented two new dose comparison parameters, the 2D normalized agreement test (NAT) and the scalar NAT index. A single-film calibration technique using multileaf collimator (MLC) delivery was developed. EDR2 film's optical density response was found to be sensitive to several factors: radiation time, length of time between exposure and processing, and phantom material. Precision of EDR2 film measurements was found to be better than 1%. For IMRT verification, EDR2 film measurements agreed with ion chamber results to 2%/2mm accuracy for single-beam fluence map verifications and to 5%/2mm for transverse plane measurements of complete plan dose distributions. The same system was used to quantitatively optimize the radiation field offset and MLC transmission beam modeling parameters for Varian MLCs. While scalar dose comparison metrics can work well for optimization purposes, the influence of external parameters on the dose discrepancies must be minimized. The ability of 2D verifications to detect delivery errors was tested with simulated data. The dosimetric characteristics of delivery errors were compared to patient-specific clinical IMRT verifications. For the clinical verifications, the NAT index and percent of pixels failing the gamma index were exponentially distributed and dependent upon the measurement phantom but not the treatment site. Delivery errors affecting all beams in the treatment plan were flagged by the NAT index, although delivery errors impacting only one beam could not be differentiated from routine clinical verification discrepancies. Clinical use of this system will flag outliers, allow physicists to examine their causes, and perhaps improve the level of agreement between radiation dose distribution measurements and calculations. The principles used to design and evaluate this system are extensible to future multidimensional dose measurements and comparisons. ^