988 resultados para root canal length measurement


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The aim of this study was to evaluate the ability of Resilon (Resilon Research, LLC, North Branford, CT) and 2 types of gutta-percha to fill simulated lateral canals when using the Obtura II system (Model 823-700; Obtura Spartan, Fenton, MO). Methods: Forty-five human single-rooted teeth were selected and subjected to root canal preparation. After that, simulated lateral canals were made at 2, 5, and 8 mm from the working length (WL). The specimens were divided into 3 groups (n = 15) according to the filling material used: Obtura Flow 150 gutta-percha (Obtura flow), Odous Endo Flow gutta-percha (Odous; Odous de Deus Ind e Corn. Ltda Belo Horizonte, MG, Brazil), and Resilon pellets (Resilon). Root canals were filled using the Obtura II system with the tip inserted to 3 mm from the WL. No sealer was used for root canal obturation. Specimens were subjected to a tooth decalcification and clearing method, and filling of the lateral canals was analyzed by digital radiography and photographs. The measurement of lateral canal filling was done using Image Tool software (UTHSCSA Image Tool for Windows version 3.0, San Antonio, TX). Data were statistically analyzed with the Kruskal-Wallis test at 5% significance. Results: All materials showed an ability to penetrate into the simulated lateral canals, with a minimum percentage of 73% in all thirds of the root canal. Conclusions: It was concluded that gutta-percha and Resilon are solid core materials with a lateral canal filling ability when used with the Obtura II system. (J Endod 2012;38:676-679)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives. To evaluate the effects of intracanal medicaments on endotoxins in root canals.Methods. Seventy-five freshly extracted maxillary incisors were used in this study. The crowns of teeth were sectioned near the CEJ in order to standardize the root length to 14 mm. The root canals were instrumented to an apical size #50 file and irrigated with 1% sodium hypochlorite solution and sterilized with 60 Co gamma irradiation. Standardized suspension containing Escherichia coli endotoxin was inoculated into the 60 root canals. The specimens were randomly assigned to 5 groups (n=15), according to the intracanal medicament used: (G1) calcium hydroxide; (G2) polymyxin B; (0) combination neomycin-potymyxin B-hydrocortisone; (G4) positive control (no intracanal medicament); (G5) negative control (no endotoxin and no intracanal medicament). After 7 days, the detoxification of endotoxin was evaluated by Limulus lysate assay and antibody production in B-tymphocytes culture.Results. Groups 1, 2 and 5 presented the best results by Limulus lysate and were significantly different to groups 3 and 4 (p<0.05). Stimulation of antibodies production in cell culture by groups 1 and 6 was smaller and statistically different than groups 2, 3, 4 and 5 (p<0.05). Groups 2 and 5 induced a small increase in the antibodies production in relation to the groups 1 and 6. Groups 3 and 4 induced a significant increase of antibodies production (p<0.05).Conclusions. The calcium hydroxide and polymyxin B intracanal medicaments detoxified endotoxin in root canals and altered the properties of LPS to stimulate the antibody production by B-Lymphocytes. The combination neomycin-polymyxin B-hydrocortisone did not detoxified endotoxin. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: As opposed to the cementation metal posts, the cementation of fiber posts has several details that can significantly influence the success of post retention. This study evaluated the effect of the relining procedure, the cement type, and the luted length of the post on fiber posts retention. Methods: One hundred eighty bovine incisors were selected to assess post retention; after endodontic treatment, the canals were flared with diamonds burs. Post holes were prepared in lengths of 5, 7.5, and 10 mm; the fiber posts were relined with composite resin and luted with RelyX ARC, RelyX Unicem, or RelyX Luting 2. All cements are manufactured by 3M ESPE (St. Paul, MN). Samples were subjected to a pull-out bond strength test in a universal testing machine; the results (N) were submitted to a three-way analysis of variance and the Tukey post hoc test (alpha = 0.05). Results: The improvement of post retention occurred with the increase of the post length luted into the root canal; the relining procedure improved the pull-out bond strength. RelyX Unicem and RelyX ARC showed similar values of retention, both showing higher values than RelyX Luting 2. Conclusion: Post length, the reining procedure, and the cement type are all important factors for improving the retention of fiber posts. (J Endod 2010;36:1543-1546)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the influence of the brush type as a earner of priming adhesive solutions and the use of paper points as a remover of the excess of these solutions on the push-out bond strength of resin cement to bovine root dentin. The null hypotheses were that brush type and the use of paper points do not affect the bond strength. Materials and Methods: The canals of 80 single-root bovine roots (16 mm in length) were prepared at 12 mm using the preparation drill (FRC Postec Plus, Ivoclar). Half of each root was embedded in acrylic resin and the specimens were divided into 8 groups, considering the factors brush type (4 levels) and paper point (2 levels) (n = 10): Gr 1: small microbrush (Cavi-Tip, SDI); Gr 2: Microbrush (Dentsply); Gr 3: Endobrush (Bisco); Gr 4: conventional brush (Bisco); Gr 5: Cavi-Tip (SDI) + paper points; Gr 6: Microbrush (Dentsply) + paper points; Gr 7: Endobrush (Bisco) + paper points; Gr 8: conventional brush (Bisco) + paper points. The root dentin was treated with a multistep total-etch adhesive system (All Bond 2). The adhesive system was applied using each microbrush, with and without using paper points. One fiber post was molded with addition silicon and 80 posts were made of resin cement (Duolink), The resin posts were luted (Duolink resin cement), and the specimens were stored for 24 h in water at 37°C. Each specimen was cut into 4 disk-shaped samples (1.8 mm in thickness), which were submitted to the push-out test. Results: The brush type (p < 0.0001) (small microbrush > microbrush = endobrush = conventional brush) and the use of paper points (p = 0.0001) (with > without) influenced the bond strength significantly (two-way ANOVA). The null hypotheses were rejected. Conclusion: The smallest brush (Cavi-Tip) and the use of paper points significantly improved the resin bond to bovine root dentin.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the effect of mechanical cycling on the bond strength of zirconia posts to root dentin. Thirty single-rooted human teeth were transversally sectioned to a length of 16 mm. The canal preparation was performed with zirconia post system drills (CosmoPost, Ivoclar) to a depth of 12 mm. For post cementation, the canals were treated with total-etch, 3-steps All-Bond 2 (Bisco), and the posts were cemented with Duolink dual resin cement (Bisco). Three groups were formed (n = 10): G1 - control, no mechanical cycling; G2 - 20,000 mechanical cycles; G3 - 2,000,000 mechanical cycles. A 1.6-mm-thick punch induced loads of 50 N, at a 45° angle to the long axis of the specimens and at a frequency of 8 Hz directly on the posts. To evaluate the bond strengths, the specimens were sectioned perpendicular to the long axis of the teeth, generating 2-mm-thick slices, approximately (5 sections per teeth), which were subjected to the push-out test in a universal testing machine at a 1 mm/min crosshead speed. The push-out bond strength was affected by the mechanical cycling (1-way ANOVA, p = .0001). The results of the control group (7.7 ± 1.3 MPa) were statistically higher than those of G2 (3.9 ± 2.2 MPa) and G3 (3.3 ± 2.3 MPa). It was concluded that the mechanical cycling damaged the bond strength of zirconia posts to root dentin.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim To assess the dimensional characteristics, flexibility and torsional behaviour of nickel-titanium retreatment instruments. Methodology Using image analysis software and high-resolution digital images, the instrument length, tip angle, diameter at 3mm from the tip and the distance between the blades (pitch length) of the following eight instruments were measured (n=12 for each measurement parameter): the ProTaper Universal retreatment (PTU-R) D1, D2 and D3 instruments; the R-Endo R1, R2 and R3 retreatment instruments; and the Mtwo retreatment (Mtwo-R) sizes 25 and 15 retreatment instruments. Maximum torque and the angular deflection at fracture as well as the bending moment at 45° were measured (n=12) according to the International Standards Organisation (ISO) specification number 3630-1. Data were analysed using the analysis of variance (α=0.05). Results The length of the active part of the instruments was found to vary according to the depth of the canal into which they were designed to reach. The pitch length also increased along the active length. The PTU-R D1 and the Mtwo-R instruments had active tips. Measurements of the bending moment at 45° revealed that the Mtwo-R 15 instrument was the most flexible, whereas the PTU-R D1 was the least flexible. The maximum torque tended to increase as the instrument diameter at 3mm from the tip increased, whereas the angular deflection at fracture varied in the opposite direction. Conclusions The geometrical characteristics of the retreatment instruments and their flexibility and torsion behaviour were consistent with their intended clinical application. © 2011 International Endodontic Journal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, curved maxillary molar root canals were instrumented with RaCe rotary system to evaluate: 1. the occurrence of canal transportation using a radiographic platform; 2. the action of the instruments on the dentin walls, centering ability and canal enlargement by analysis of digital images; and the percentage of regular dentin surfaces and debris within the canal by histological analysis. Ten mesiobuccal roots of extracted human maxillary molars were embedded in acrylic resin and sectioned at the middle and apical thirds. Root canal shaping was performed using the RaCe rotary system at 250 rpm and 1 Ncm torque. Each instrument set was used five times according to a crowndown technique in the following sequence: 40/0.10, 35/0.08, 25/0.06, 25/0.04, 25/0.02 (working length - WL), 30/0.02 (WL) and 35/0.02 (WL). Each instrument was inserted until resistance was felt and then pulled back, followed by brushing movements towards all canal walls. Each specimen was assessed by three study methods: radiographic platform, digitized image assessment and histological analysis. The radiographic platform showed lack of apical transportation. No statistically significant difference (Wilcoxon test, p>0.05) was found between the middle and apical thirds regarding instrument action on dentin walls, centering ability, area of root canal enlargement, percentage of regular dentin surfaces and debris within the root canal. It may be concluded that RaCe system is a suitable method for the preparation of curved root canals, regarding the maintenance of root canal original path, action on dentin walls, canal enlargement and removal of debris from the root canal lumen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study is to evaluate the measurement accuracy of endodontic files obtained by digital and conventional radiographies in primary teeth. Kerr and Hedströen files (# 20), with the reference as the apparent length of tooth, were inserted in the root canal of 18 extracted primary teeth, which were x-rayed by digital and conventional techniques. Measurements from a reference point to the apical end were carried out by an experienced operator twice in a week. An electronic ruler was used for the digital method and a caliper was used for the conventional method. The data were subjected to Pearson correlation test and Student´s t test (p = 0.05). The correlation between the first and the second measurements was r = 0.99, regardless the type of file and method. Comparing the measurements within the methods, the agreement was r = 0.96 for Kerr and r = 0.95 for Hedströen files. The values of length files in the digital radiographies were statistically lower than that obtained in the conventional radiographies (p = 0.02). However, the values obtained by the two methods were statistically similar to real length of teeth for Kerr files (p = 0.29) and for Hedströen files (p = 0.18). The digital radiography was a more trustful method to obtain the lengths of endodontic files.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to assess, in vivo, the accuracy of the NovApex (R) electronic foramen locator in determining working length (WL) in vital and necrotic posterior teeth. The NovApex (R) was used in 144 canals: 35 teeth with vital pulps (68 canals) and 42 teeth with necrotic pulps (76 canals). WL was measured with the NovApex (R) locator and confirmed using the radiographic method. Differences between electronic and radiographic measurements ranging between 0.0 and 0.4 millimeters were classified as acceptable; differences equal to or greater than 0.5 millimeter were considered unacceptable. Pearson's chi-square test was used to assess the influence of pulp condition on the accuracy of NovApex (R) (alpha = 0.05). Regardless of pulp condition, differences between electronic and radiographic WL measurements were acceptable in 73.61% of the canals. No statistically significant differences in accuracy were observed when comparing vital and necrotic canals (p > 0.05). There were 38 unacceptable measurements. In none of these cases was the file tip located beyond the radiographic apex; in 32, it was located short of the NovApex (R) measurement. Pulp condition had no significant effect on the accuracy of NovApex (R).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: This study aimed to describe the anatomy of mandibular premolars with type IX canal configuration by using micro–computed tomography. Methods: Mandibular premolars with radicular grooves (n = 105) were scanned, and 16 teeth with type IX configuration were selected. Number and location of canals, distances between anatomic landmarks, occurrence of apical delta, root canal fusion, and furcation canals, as well as 2-dimensional (area, perimeter, roundness, major and minor diameters) and 3-dimensional (volume, surface area, and structuremodel index) analysis were performed. Data were statistically compared by using analysis of variance and Kruskal-Wallis tests (a = 0.05). Results: Overall, specimens had 1 root with a main canal that divided into mesiobuccal, distobuccal, and lingual canals at the furcation level. Mean length of the teeth was 22.9 2.06 mm, and the configuration of the pulp chamber was mostly triangle-shaped. Mean distances from the furcation to the apex and cementoenamel junction were 9.14 2.07 and 5.59 2.19 mm, respectively. Apical delta, root canal fusion, and furcation canals were present in 4, 5, and 10 specimens, respectively. No statistical differences were found in the 2-dimensional and 3-dimensional analyses between root canals (P > .05). Conclusions: Type IX configuration of the root canal system was found in 16 of 105 mandibular premolars with radicular grooves. Most of the specimens had a triangle-shaped pulp chamber. Within this anatomic configuration, complexities of the root canal systems such as the presence of furcation canals, fusion of canals, oval-shaped canals in the apical third, small orifices at the pulp chamber level, and apical delta were also observed

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION If a surgical approach is chosen to treat a multirooted tooth affected by persistent periapical pathosis, usually only the affected roots are operated on. The present study assessed the periapical status of the nonoperated root 5 years after apical surgery of the other root in mandibular molars. METHODS Patients treated with apical surgery of mandibular molars with a follow-up of 5 years were selected. Patient-related and clinical parameters (sex, age, smoking, symptoms, and signs of infection) before surgery were recorded. Preoperative intraoral periapical radiographs and radiographs 5 years after surgery were examined. The following data were collected: tooth, operated root, type and quality of the coronal restoration, marginal bone level, length and homogeneity of the root canal filling, presence of a post/screw, periapical index (PAI) of each root, and radiographic healing of the operated root. The presence of apical pathosis of the nonoperated root was analyzed statistically in relation to the recorded variables. RESULTS Thirty-seven patients fulfilled the inclusion criteria. Signs of periapical pathosis in the nonoperated root 5 years after surgery (PAI ≥ 3) could be observed in only 3 cases (8.1%). Therefore, statistical analysis in relation to the variables was not possible. The PAI of the nonoperated root before surgery had a weak correlation with signs of apical pathosis 5 years after surgery. CONCLUSIONS Nonoperated roots rarely developed signs of new apical pathosis 5 years after apical surgery of the other root in mandibular molars. It appears reasonable to resect and fill only roots with a radiographically evident periapical lesion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes bibliographical references.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The cleaning capacity of Hero 642 nickel-titanium files, complemented by the Hero Apical instruments in flattened roots, was determined by histological analysis, considering the area of action of the instruments on the coronal walls and the presence of remaining debris. Twenty-four single-canal, human mandibular incisors were divided into three groups and prepared as follows: GI, instrumented with Hero 642 NiTi files 30/.06, 25/.06, 20/.06, 25/.06, and 30/.06; GII, instrumented as GI followed by Hero Apical size 30/.06; GIII, instrumented as GI followed by Hero Apical sizes 30/.06 and 30/.08, then returning to 30/.06 with pendulum movements. The apical thirds were prepared for histological processing, analyzed at 40× magnification and the images were examined morphometrically. Statistical analysis showed that GIII presented the best results for removing debris (5.22% ± 4.13), with more contact between the instruments and the root canal walls (19.31% ± 0.15). This differed statistically from GI (14.04% ± 4.96 debris removal, with 42.96% ± 7.11 instrument contact) and GII (12.62% ± 5.76 debris removal, with 35.01% ± 0.15 instrument contact). Root canal preparation with Hero 642, complemented by Hero Apical instruments (30/.06 and 30/.08, then re-instrumented with Hero Apical 30/.06 using pendulum movements), was more efficient for debris removal and allowed more contact of the instruments with the root canal walls. GII presented the worst results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The determination of the success of endodontic treatment has been often discussed based on outcome obtained by periapical radiography. The aim of this study was to verify the influence of intracanal post on apical periodontitis detected by cone-beam computed tomography (CBCT). A consecutive sample of 1020 images (periapical radiographs and CBCT scans) taken from 619 patients (245 men; mean age, 50.1 years) between February 2008 and September 2009 were used in this study. Presence and intracanal post length (short, medium and long) were associated with apical periodontitis (AP). Chi-square test was used for statistical analyses. Significance level was set at p<0.01. The kappa value was used to assess examiner variability. From a total of 591 intracanal posts, AP was observed in 15.06%, 18.78% and 7.95% using periapical radiographs, into the different lengths, short, medium and long, respectively (p=0.466). Considering the same posts length it was verified AP in 24.20%, 26.40% and 11.84% observed by CBCT scans, respectively (p=0.154). From a total of 1,020 teeth used in this study, AP was detected in 397 (38.92%) by periapical radiography and in 614 (60.19%) by CBCT scans (p<0.001). The distribution of intracanal posts in different dental groups showed higher prevalence in maxillary anterior teeth (54.79%). Intracanal posts lengths did not influenced AP. AP was detected more frequently when CBCT method was used.