321 resultados para removable
Resumo:
Introduction and Objective: Photoelasticity consists of an experimental technique of stress analysis. This technique is very used in most different areas including Dentistry. This literature review presents the several applications of photoelastic technique in Dentistry the several applications of photoelastic technique in Dentistry as well as its advantages and disadvantages. Literature review: Based on this method of analysis, it is possible the verification of the stress distribution and deformation in structures with complex geometry as maxilla and mandible. It can be used to evaluate the distribution of stress on several types of prosthesis as removable partial denture systems with different retention systems, conventional implant prosthesis, overdentures and Brånemark protocols. Moreover, photoelasticity can be used to assess the stress generated by various by various orthodontic movements, different orthodontic systems and different materials (orthodontic wires). In addition, it is used to analyze different defects of maxillectomy, splint types on traumatized tooth and post-core restoration methods. This technique can also be used to assess dental instruments such as evaluation of different designs of periodontal probe. Conclusion: The photoelastic analysis has been a technique of great importance in health area studies, more specifically in Dentistry. Based on this method of analysis, it is possible to measure the stress distribution and deformation in structures with complex geometry as maxilla and mandible.
Resumo:
Introduction: the oral rehabilitation in edentulous patients using removable complete dentures is a classic treatment, easily accessible, and presenting satisfactory results. However, to succeed in this type of treatment, stability is an extremely important factor. The neutral zone technique for the production of complete dentures determines the oral cavity space for the positioning of teeth and denture base that provide a neutralization of the forces delivered by lips, cheeks, and tongue, providing better stability and retention of prostheses, which is indicated in cases with history of difficulties in adapting the conventional mandibular denture. Objective and case report: this paper aimed to describe a clinical case report of the oral rehabilitation of a patient with paraprosthetic muscles hypertonicity through removable complete dentures produced by the neutral zone technique, using condensation silicone. Final considerations: the use of condensation silicone for the development of the neutral zone technique showed to be a good alternative for the development of this clinical case, providing satisfactory stability and retention of the complete mandibular denture.
Resumo:
Unilateral or bilateral distal-extension removable partial dentures present complex biomechanics. The movements in different directions, associated with the alveolar ridge shape and soft tissue resilience can lead to damaging forces on the supporting structures. The association between implants / removable partial denture aims to provide better mechanical and biological properties to the stomatognathic system. OBJECTIVE: The aim of this paper was to review the articles about the effect of implant support on distal extension removable partial dentures. LITERATURE REVIEW AND CONCLUSION: Studies have shown that this combination provides greater support, retention and stability to the prosthesis, thus limiting their approach movement toward supporting tissues and providing functional and psychological comfort to patients.
Resumo:
Introduction: Unilateral or bilateral distal-extension removable partial dentures present complex biomechanics. The movements in different directions, associated with the alveolar ridge shape and soft tissue resilience can lead to damaging forces on the supporting structures. The association between implants / removable partial denture aims to provide better mechanical and biological properties to the stomatognathic system. Objective: The aim of this paper was to review the articles about the effect of implant support on distal extension removable partial dentures. Literature review and conclusion: Studies have shown that this combination provides greater support, retention and stability to the prosthesis, thus limiting their approach movement toward supporting tissues and providing functional and psychological comfort to patients.
Resumo:
Nowadays, the fixed partial dentures and/or dental implants is the most requested treatmentby the majority of partially edentulous patients. However, depending on the periodontal condition of the remaining teeth, as well as the bone condition of the prosthetic space, the oral rehabilitation with these treatments may be limited or even contraindicated. In such cases, the use of removable partial dentures associated to attachments becomes an important alternative for aesthetic and functional rehabilitation. Attachments are mechanical devices consisted of two parts (patrix-matrix), one placed inside another, which act as direct retainer, providing retention, support and stability to the dentures. These devices can be classified as intra or extracoronal attachments, considering their position in relation to the abutment tooth. However, regardless the type of attachment, the association between fixed and removable partial dentures should be performed respecting the biomechanical principles of both. Therefore, the purpose of this study was to review and discuss the literature about the clinical and laboratory implications of the association between fixed and removable partial dentures by means of attachments.
Resumo:
Aim: The purpose of this study was to assess chlorhexidine effects on plaque index and salivary levels of mutans streptococci (MS) when used as the immersion solution for removable orthodontic appliances and added to their acrylic resin composition. Methods: Forty-five patients (6 to 12 years old) were randomly assigned into three groups with 15 patients each. Group I (control)—without orthodontic appliances disinfection; Group II—removable orthodontic appliances which had been immersed in 0.12% chlorhexidine digluconate overnight (8 hours), and Group III—orthodontic appliances in which 0.12% chlorhexidine digluconate solution had been incorporated into their resin composition. Saliva was collected for quantification of MS and evaluation of plaque index was performed before and after installation of orthodontic appliance at 0, 2, 4, 6, 8, and 10 weeks. Data were analyzed by using analysis of variance. Results: Number of MS colonies in saliva and plaque index showed no statistically differences among groups at the different periods (p > 0.05). Conclusions: It could be concluded that chlorhexidine incorporation into the acrylic resin of removable orthodontic appliances at 0.12% concentration and immersion of the appliance into 0.12% chlorhexidine solution were not effective in reducing plaque index and the number of MS in saliva.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Squamous cell carcinoma is a malignant epithelial neoplasm characterized by variable clinical manifestations. When located in the gingiva, this neoplasm may mimic common inflammatory lesions. The aim of this study was to report a case of atypical squamous cell carcinoma, in which the patient had no risk factors for the development of this neoplasm. A 61 year old Caucasian female was seen with a 3 month history of a rapidly growing, painful nodule in the gingiva adjacent to tooth #11. Clinical examination revealed a proliferative lesion in the vestibular marginal gingiva of teeth #11 and #12, presenting with purulent exudation. Thus, in view of the clinical symptoms and differential diagnosis of an infectious granulomatous process and malignant neoplasm, an incisional biopsy was obtained from the lesion. The diagnosis of squamous cell carcinoma was made and fourteen days after incisional biopsy, healing was found to be unsatisfactory. The patient was referred for treatment consisting of surgical excision of the tumour. A removable partial denture was fabricated for rehabilitation, one month after surgery of the maxilla; the patient was submitted to dissection of the regional lymph nodes and radiotherapy for an additional 3 months. Three years after the end of treatment, the patient continues to be followed-up and does not show any sign of recurrence. Gingival squamous cell carcinoma is a condition which chance of cure is higher when carcinomatous lesions are diagnosed and treated early. In this instance dentists play an important role in early detection of gingival squamous cell carcinoma.
Resumo:
The treatment of orofacial tumors may cause facial deformities by losses of structures that affect basic functions, i.e. feeding, speech, and the reduction of patient self-steam. A white male patient was diagnosed with epidermoid cancer on the mandibular alveolar ridge with infiltration staging IV A. The patient was submitted to a mandibulectomy associated with a complete extraction of mandibular teeth. For rehabilitation, a conventional denture for the mandibular arch and a removable partial denture for the maxillary arch were fabricated. A correct occlusal adjustment and a satisfactory amount of alveolar bone was favorable for conventional dentures of the prostheses bases improve their retention and stability. After one year of follow-up, the patient was adapted to the prostheses, satisfied with their retention, and reported an improvement on his feeding. The prosthetic rehabilitation of patients after a partial mandibulectomy is essential for their self-steam. Conventional dentures may have their retention and stability improved if they are well fabricated, recorded and have a balanced occlusion. A correct occlusal adjustment and an adequate retention of the prostheses bases may improve their retention and stability. Patients without xerostomy and with a satisfactory amount of alveolar bone may have a favorable prognosis for conventional dentures.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
To evaluate the change in masticatory efficiency and quality of life of patients treated with mandibular Kennedy class I removable partial dentures (RPDs) and maxillary complete dentures at the Department of Dentistry of the Federal University of Rio Grande do Norte. A total of 33 Kennedy class I patients were rehabilitated with maxillary complete dentures, and mandibular RPDs were selected for this non-randomized prospective intervention study. The patients had a mean age of 59.1 years. Masticatory efficiency was evaluated by colorimetric assay using fuchsin capsules. The measurements were conducted at baseline and 2 and 6 months after prosthesis insertion. Quality of life was evaluated using the Oral Health Impact Profile (OHIP-14) at baseline and 6 months after denture insertion. The Kolmogorov-Smirnov normality test was applied. Masticatory efficiency was evaluated by repeated measures ANOVA. Oral health-related quality of life was compared using the paired t test. There was no statistically significant difference in masticatory efficiency after denture insertion (p = 0.101). Significant differences were found (p = 0.010) for oral health-related quality of life. A significant improvement in psychological discomfort (p < 0.01) and psychological disability (p < 0.01) was observed. Mean difference value (95 % confidence interval) was 6.8 (3.8 to 9.7) points, reflecting a low impact of oral health on quality of life, considering the 0-56 range of variation of the OHIP-14 and a Cohen's d of 1.13. According to the results of the present study, rehabilitation with Kennedy class I RPDs and complete dentures did not influence masticatory efficiency but improved oral health-related quality of life. The association between the patient's quality of life and the masticatory efficiency is important for treatment predictability.
Resumo:
An experimental study was undertaken in arder to find out lhe behavior of the required force to yield dislodgement of circumierential clasps of removable partial dentures ou two groups of samples. 1 with retentive terminais engaging and acting ou enamel 2 with retentive terminais engaging on enamel and acting on composite resm With this aim a device was designed based on a sewing machine (brand name Elgin) that could repeatedly simulate lhe introduction-removal movement of circunferencial clasps ou the samples. ln addiction the device had a platform to sustain the samples and permit measurements, a cycle counter and a dynamometer. The samples were constructed by inclusion in dental stone of extracted natural molar teeth whose retentive areas were ou natural enamel or composite resin addictions.The clasps were fabricated from wax ups of resin and wax and were cast with chromium cobalt alloy. The composite resin used was one of the last generation, monomodal type, photopolymerized and binded to the enamel by the acid etching technique. Tests were carried out in aqueous enviroment. Is was established a maximum of 5.000 cycles for each of the samples. Observatins were made from 100 to 100 cycles until 2.000 and from 200 to 200 cycles to 5.000. Results showed that variations in the amount of the required force for dislodgement of the clasps from the samples during the test periods had no significancy eather to those with retentive areas on the enamel or to those with retentive fabricated with addictions of composite resin
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Reconstrução imediata de fenestração peri-implantar com enxerto autógeno em bloco de ramo mandibular
Resumo:
Alveolar wall fenestrations are common during implant placement. The aim of this paper is to report a case where a peri-implant bone fenestration was reconstructed immediately after implant placement by an autogenous mandibular bone block. A male patient was referred to the Department of Surgical and Integrated Clinics to substitute his Kennedy´s Class IV removable partial denture for an implantsupported fixed prosthesis. A peri-implant bone fenestration at the buccal wall was seen at the region of 12, being reconstructed by a mandibular bone block secured by a bicortical screw. Six months later the surgical procedures, an implant-supported complete fixed partial prosthesis was developed. The autogenous bone block harvested from the mandibular ramus was a safe alternative to reconstruct the peri-implant bone defect such as fenestration types.