461 resultados para ramp metering
Resumo:
This study aimed to develop a scientific and practical tool to be used to assess horse welfare after commercial transport over long journeys. A set of physical, behavioural and environmental measures was selected, covering welfare aspects of both transport and unloading procedures. The protocol was field-tested on 51 intra-EU commercial transports arriving at different sites in Italy. Univariate analysis was implemented to look for associations between the input variables (environmental hazards potentially affecting the animal well-being during long transports) and the outcome variables (direct evaluation of the animal condition). No severe welfare impairments were recorded (ie dead on arrival, severe injuries, non-ambulatory animals), while milder ones were more frequent at unloading (eg slipping; 36.7%, reluctance to move; 9.6%). Correlations emerged between ramp slope and falling; type of ramp floor and slipping; fast gait and the presence of gaps between the ramp and the floor. The horses' behaviour was also related to the type of handling procedure used. The measures were repeatable and practical to apply and score during real-time unloading. This work provides a sound basis for a new and practical welfare assessment tool for horses travelling over long journeys. Careful and constant application of this protocol would provide stakeholders with the opportunity to track and monitor changes in the industry over time, as well as to identify high risk areas in transport routines.
Resumo:
Portugal é um dos países europeus com melhor cobertura espacial e populacional de rede de autoestradas (5º entre os 27 da UE). O acentuado crescimento desta rede nos últimos anos leva a que seja necessária a utilização de metodologias de análise e avaliação da qualidade do serviço que é prestado nestas infraestruturas, relativamente às condições de circulação. Usualmente, a avaliação da qualidade de serviço é efetuada por intermédio de metodologias internacionalmente aceites, das quais se destaca a preconizada no Highway Capacity Manual (HCM). É com esta última metodologia que são habitualmente determinados em Portugal, os níveis de serviço nas diversas componentes de uma autoestrada (secções correntes, ramos de ligação e segmentos de entrecruzamento). No entanto, a sua transposição direta para a realidade portuguesa levanta algumas reservas, uma vez que os elementos que compõem o ambiente rodoviário (infraestrutura, veículo e condutor) são distintos dos da realidade norte-americana para a qual foi desenvolvida. Assim, seria útil para os atores envolvidos no setor rodoviário dispor de metodologias desenvolvidas para as condições portuguesas, que possibilitassem uma caracterização mais realista da qualidade de serviço ao nível da operação em autoestradas. No entanto, importa referir que o desenvolvimento de metodologias deste género requer uma quantidade muito significativa de dados geométricos e de tráfego, o que acarreta uma enorme necessidade de meios, quer humanos, quer materiais. Esta abordagem é assim de difícil execução, sendo por isso necessário recorrer a metodologias alternativas para a persecução deste objetivo. Ultimamente tem-se verificado o uso cada vez mais generalizado de modelos de simulação microscópica de tráfego, que simulando o movimento individual dos veículos num ambiente virtual permitem realizar análises de tráfego. A presente dissertação apresenta os resultados obtidos no desenvolvimento de uma metodologia que procura recriar, através de simuladores microscópicos de tráfego, o comportamento das correntes de tráfego em secções correntes de autoestradas com o intuito de, posteriormente, se proceder à adaptação da metodologia preconizada no HCM (na sua edição de 2000) à realidade portuguesa. Para tal, com os simuladores microscópicos utilizados (AIMSUN e VISSIM) procurou-se reproduzir as condições de circulação numa autoestrada portuguesa, de modo a que fosse possível analisar as alterações sofridas no comportamento das correntes de tráfego após a modificação dos principais fatores geométricos e de tráfego envolvidos na metodologia do HCM 2000. Para o efeito, realizou-se uma análise de sensibilidade aos simuladores de forma a avaliar a sua capacidade para representar a influência desses fatores, com vista a, numa fase posterior, se quantificar o seu efeito para a realidade nacional e dessa forma se proceder à adequação da referida metodologia ao contexto português. Em resumo, o presente trabalho apresenta as principais vantagens e limitações dos microssimuladores AIMSUN e VISSIM na modelação do tráfego de uma autoestrada portuguesa, tendo-se concluído que estes simuladores não são capazes de representar de forma explícita alguns dos fatores considerados na metodologia do HCM 2000, o que impossibilita a sua utilização como ferramenta de quantificação dos seus efeitos e consequentemente inviabiliza a adaptação dessa metodologia à realidade nacional. São, no entanto, referidas algumas indicações de como essas limitações poderão vir a ser ultrapassadas, com vista à consecução futura dessa adequação.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização de Vias de Comunicação e Transportes
Resumo:
This paper presents a complete, quadratic programming formulation of the standard thermal unit commitment problem in power generation planning, together with a novel iterative optimisation algorithm for its solution. The algorithm, based on a mixed-integer formulation of the problem, considers piecewise linear approximations of the quadratic fuel cost function that are dynamically updated in an iterative way, converging to the optimum; this avoids the requirement of resorting to quadratic programming, making the solution process much quicker. From extensive computational tests on a broad set of benchmark instances of this problem, the algorithm was found to be flexible and capable of easily incorporating different problem constraints. Indeed, it is able to tackle ramp constraints, which although very important in practice were rarely considered in previous publications. Most importantly, optimal solutions were obtained for several well-known benchmark instances, including instances of practical relevance, that are not yet known to have been solved to optimality. Computational experiments and their results showed that the method proposed is both simple and extremely effective.
Resumo:
Dissertação para obtenção do grau de Mestre em Engenharia Electrotécnica
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil - Área de especialização de Hidráulica
Resumo:
A forte preocupação ambiental, nomeadamente a emissão de Gases com Efeito de Estufa (GEE), aliada à constante ameaça do esgotamento dos combustíveis de origem fóssil, leva à necessidade de consumir energia de forma mais eficiente. Neste sentido, surge a promoção da eficiência energética nos diversos sectores consumidores de energia em todo o Mundo. Sabendo que passamos mais de 80% do nosso tempo dentro de edifícios, e que cerca de 40% da energia mundial é consumida nos mesmos [ADENE], é importante operar no sentido de promover a utilização racional de energia e incentivar ao consumo eficiente da mesma nos edifícios. Apesar do esforço que tem sido realizado a nível nacional, no sentido de melhorar a eficiência energética em edifícios de serviços, através da implementação de legislação diversa e de vários programas de incentivo, existem ainda várias lacunas a serem colmatadas e muito trabalho a fazer nesse sentido. Por tudo isto, e principalmente por ter constantemente em mente premissas como “a energia mais barata é aquela que não se consome” ou “não podemos gerir aquilo que não medimos”, surgiu a ideia de realizar esta dissertação, onde inicialmente através de dados provenientes de telecontagem se desenvolve uma tentativa de padronização/tipificação do consumo eléctrico em seis edifícios de escritórios, identificando-se assim algumas situações anómalas em diversos diagramas de carga construídos. Relaciona-se também o consumo eléctrico dos seis edifícios com algumas variáveis exógenas, de modo a perceber a influência das mesmas no consumo eléctrico de cada edifício. Numa vertente mais prática, foram identificadas e quantificadas potenciais medidas de melhoria, comportamentais e técnicas, num dos edifícios em estudo, de modo a poder contribuir para a redução do consumo energético do mesmo. Espera-se que este trabalho, possa eventualmente constituir uma ajuda na caracterização de consumos e detecção de medidas de melhoria em edifícios de escritórios, alcançando a eficiência energética neste tipo de instalações e facilitando assim o trabalho de vários profissionais do sector. Pretende-se igualmente demonstrar a importância da eficiência energética na gestão do uso da energia eléctrica em edifícios, e efectuar um paralelo entre a energia economizada por meio da implementação de medidas/acções de uso racional e eficiente, com a redução da queima de combustíveis fosseis na geração de energia eléctrica e a sua consequente redução nas emissões de dióxido de carbono (CO2), com o objectivo final de melhorar a qualidade de vida no nosso planeta.
Resumo:
As centrais termoelétricas convencionais convertem apenas parte do combustível consumido na produção de energia elétrica, sendo que outra parte resulta em perdas sob a forma de calor. Neste sentido, surgiram as unidades de cogeração, ou Combined Heat and Power (CHP), que permitem reaproveitar a energia dissipada sob a forma de energia térmica e disponibilizá-la, em conjunto com a energia elétrica gerada, para consumo doméstico ou industrial, tornando-as mais eficientes que as unidades convencionais Os custos de produção de energia elétrica e de calor das unidades CHP são representados por uma função não-linear e apresentam uma região de operação admissível que pode ser convexa ou não-convexa, dependendo das caraterísticas de cada unidade. Por estas razões, a modelação de unidades CHP no âmbito do escalonamento de geradores elétricos (na literatura inglesa Unit Commitment Problem (UCP)) tem especial relevância para as empresas que possuem, também, este tipo de unidades. Estas empresas têm como objetivo definir, entre as unidades CHP e as unidades que apenas geram energia elétrica ou calor, quais devem ser ligadas e os respetivos níveis de produção para satisfazer a procura de energia elétrica e de calor a um custo mínimo. Neste documento são propostos dois modelos de programação inteira mista para o UCP com inclusão de unidades de cogeração: um modelo não-linear que inclui a função real de custo de produção das unidades CHP e um modelo que propõe uma linearização da referida função baseada na combinação convexa de um número pré-definido de pontos extremos. Em ambos os modelos a região de operação admissível não-convexa é modelada através da divisão desta àrea em duas àreas convexas distintas. Testes computacionais efetuados com ambos os modelos para várias instâncias permitiram verificar a eficiência do modelo linear proposto. Este modelo permitiu obter as soluções ótimas do modelo não-linear com tempos computationais significativamente menores. Para além disso, ambos os modelos foram testados com e sem a inclusão de restrições de tomada e deslastre de carga, permitindo concluir que este tipo de restrições aumenta a complexidade do problema sendo que o tempo computacional exigido para a resolução do mesmo cresce significativamente.
Resumo:
This Thesis has the main target to make a research about FPAA/dpASPs devices and technologies applied to control systems. These devices provide easy way to emulate analog circuits that can be reconfigurable by programming tools from manufactures and in case of dpASPs are able to be dynamically reconfigurable on the fly. It is described different kinds of technologies commercially available and also academic projects from researcher groups. These technologies are very recent and are in ramp up development to achieve a level of flexibility and integration to penetrate more easily the market. As occurs with CPLD/FPGAs, the FPAA/dpASPs technologies have the target to increase the productivity, reducing the development time and make easier future hardware reconfigurations reducing the costs. FPAA/dpAsps still have some limitations comparing with the classic analog circuits due to lower working frequencies and emulation of complex circuits that require more components inside the integrated circuit. However, they have great advantages in sensor signal condition, filter circuits and control systems. This thesis focuses practical implementations of these technologies to control system PID controllers. The result of the experiments confirms the efficacy of FPAA/dpASPs on signal condition and control systems.
Resumo:
Biopolttoaineet ovat tärkeä energianlähde suomalaisessa energiantuotannossa. Biopoltto- aineille on kuitenkin ominaista laadun vaihtelevuus. Yksi tärkeimmistä laatutekijöistä on kosteus, joka vaikuttaa myös polttoaineen energiasisältöön. Laatutekijät puolestaan vai- kuttavat polttoainekäsittelyyn, polttoprosessiin ja koko laitoksen hyötysuhteeseen. Tämän työn tarkoituksena oli tutkia voisiko biopolttoaineiden online-laadunmittaus tuoda lisäarvoa energiantuotantolaitokselle. Esimerkkinä käytettiin yhtä online-laadunmittaus- sovellusta, InrayFuel-röntgenmittausjärjestelmää. Sillä voidaan seurata biopolttoaineiden kosteutta ja polttoaineen sisältämiä vierasaineita. Työssä on laadittu kustannusanalyysi, jolla pyritään selvittämään, onko nykyisen kertaluontoisen mittausmenetelmän korvaami- nen jatkuvatoimisella kannattavaa. Esimerkkilaitoksena on Etelä-Savon Energian Pur- sialan voimalaitos, jossa röntgenmittausjärjestelmään on testattu. Saatujen tulosten mukaan investoiminen esimerkkimittausjärjestelmään maksaisi itsensä takaisin alle vuodessa. Kun laitoksella pystytään seuraamaan polttoaineen laatua jatkuva- toimisesti, laadunhallinta paranee ja sitä kautta voidaan saavuttaa kustannussäästöjä. Polt- toaineesta johtuvat häiriötilanteet vähenevät, polttoaine on mahdollista optimoida edulli- semmaksi polton kannalta ja poltto-olosuhteita voidaan säätää paremmin, jolloin päästöt vähenevät ja hyötysuhde kasvaa. Työssä käytetty laskenta analysoi kuitenkin hyvin ylei- sellä tasolla, sillä käytössä ei ollut laitoksen omaa taselaskentajärjestelmää. Laskenta siis sisältää paljon oletuksia. Tämän ja rohkaisevien tulosten vuoksi tutkimusta jatkuvatoimi- sen laadunmittauksen hyödyistä kannattaa tehdä enemmän.
Resumo:
Tony Biernacki's rowing career began in 1950 in Ottawa with his first Henley medal in 1952 in the coxless four. Sculling became his real means to success. Since 1955 he has posted record times and had numerous wins in the single. He represented Canada at the National Team between 1958 and 1967 and raced in the single at the British Empire Games and Pan Am Games (Chicago, silver medal) and pair at the Worlds in Yugoslavia in 1966. He won the Olympic trials in 1960 in Rome, but was unable to go. Upon his retirement from competition Tony was hired as the Team Manager for the following Pan Am Games. Tony was hired by Brock University in 1965 as a technician in the Chemistry Department. He became the head rowing coach that same year and began women’s rowing at the university level in Ontario with the first women’s crew in 1967. As Brock's second coach ever, he led the teams to championship form and kept the athletes racing through the summer regatta season. Tony remained at Brock from 1965 to 1980. He was one of the founders of The Canadian Masters Rowing Committee and he helped to initiate master's racing at the Canadian Henley. In 1985 he won the single, double and quad at the World Masters Regatta in Toronto. For a number of years he was also the world record holder for his age category on the C2 ergometer. His last heartfelt project was the construction of a wheelchair ramp at Resurrection Lutheran Church where he was an active member. Mr. Biernacki passed away on January 9, 1998 at the age of 66 after a valiant battle with cancer only a month after being awarded the Canadian Coaching Provincial Coaching Award. He is survived by his wife Janet, daughters Tracy, Tammy Pauls, and Tory Phannenhour, and son, Tony Jr. He is also survived by several grandchildren.
Resumo:
On average approximately 13% of the water that is withdrawn by Canadian municipal water suppliers is lost before it reaches final users. This is an important topic for several reasons: water losses cost money, losses force water agencies to draw more water from lakes and streams thereby putting more stress on aquatic ecosystems, leaks reduce system reliability, leaks may contribute to future pipe failures, and leaks may allow contaminants to enter water systems thereby reducing water quality and threatening the health of water users. Some benefits of leak detection fall outside water agencies’ accounting purview (e.g. reduced health risks to households connected to public water supply systems) and, as a result, may not be considered adequately in water agency decision-making. Because of the regulatory environment in which Canadian water agencies operate, some of these benefits-especially those external to the agency or those that may accrue to the agency in future time periods- may not be fully counted when agencies decide on leak detection efforts. Our analysis suggests potential reforms to promote increased efforts for leak detection: adoption of a Canada-wide goal of universal water metering; development of full-cost accounting and, pricing for water supplies; and co-operation amongst the provinces to promulgate standards for leak detection efforts and provide incentives to promote improved efficiency and rational investment decision-making.
Resumo:
This thesis investigated the modulation of dynamic contractile function and energetics of work by posttetanic potentiation (PTP). Mechanical experiments were conducted in vitro using software-controlled protocols to stimulate/determine contractile function during ramp shortening, and muscles were frozen during parallel incubations for biochemical analysis. The central feature of this research was the comparison of fast hindlimb muscles from wildtype and skeletal myosin light chain kinase knockout (skMLCK-/-) mice that does not express the primary mechanism for PTP: myosin regulatory light chain (RLC) phosphorylation. In contrast to smooth/cardiac muscles where RLC phosphorylation is indispensable, its precise physiological role in skeletal muscle is unclear. It was initially determined that tetanic potentiation was shortening speed dependent, and this sensitivity of the PTP mechanism to muscle shortening extended the stimulation frequency domain over which PTP was manifest. Thus, the physiological utility of RLC phosphorylation to augment contractile function in vivo may be more extensive than previously considered. Subsequent experiments studied the contraction-type dependence for PTP and demonstrated that the enhancement of contractile function was dependent on force level. Surprisingly, in the absence of RLC phosphorylation, skMLCK-/- muscles exhibited significant concentric PTP; consequently, up to ~50% of the dynamic PTP response in wildtype muscle may be attributed to an alternate mechanism. When the interaction of PTP and the catchlike property (CLP) was examined, we determined that unlike the acute augmentation of peak force by the CLP, RLC phosphorylation produced a longer-lasting enhancement of force and work in the potentiated state. Nevertheless, despite the apparent interference between these mechanisms, both offer physiological utility and may be complementary in achieving optimal contractile function in vivo. Finally, when the energetic implications of PTP were explored, we determined that during a brief period of repetitive concentric activation, total work performed was ~60% greater in wildtype vs. skMLCK-/- muscles but there was no genotype difference in High-Energy Phosphate Consumption or Economy (i.e. HEPC: work). In summary, this thesis provides novel insight into the modulatory effects of PTP and RLC phosphorylation, and through the observation of alternative mechanisms for PTP we further develop our understanding of the history-dependence of fast skeletal muscle function.
Resumo:
Les récepteurs couplés aux protéines G (RCPGs) constituent la plus grande classe de récepteurs membranaires impliqués dans la transmission des signaux extracellulaires. Traditionnellement, la transmission de la signalisation par les RCPGs implique l’activation d’une protéine G hétéro-trimérique qui pourra à son tour moduler l’activité de divers effecteurs intracellulaires. Ce schéma classique de signalisation s’est complexifié au fils des années et l’on sait maintenant qu’en plus d’interagir avec les protéines G, les RCPGs s’associent avec une panoplie d’autres protéines afin de transmettre adéquatement les signaux extracellulaires. En particulier, la découverte d’une famille de protéines transmembranaires modulant la fonction des RCPGs, baptisées protéines modifiant l’activité des récepteurs (« receptor activity-modifying proteins » ; RAMPs), a changé la façon de concevoir la signalisation par certains RCPGs. Dans le cas du récepteur similaire au récepteur de la calcitonine (« calcitonin-like receptor » ; CLR), l’association avec les RAMPs permet l’acheminement à la surface cellulaire du récepteur tout en modulant ses propriétés pharmacologiques. Lorsqu’il est associé avec RAMP1, le CLR fonctionne comme un récepteur du peptide relié au gène de la calcitonine (« calcitonin gene-related peptide » ; CGRP), alors qu’il devient un récepteur de l’adrénomedulline lorsqu’il interagit avec RAMP2 ou RAMP3. D’autre part, en plus d’interagir avec des protéines accessoires transmembranaires telles les RAMPs, les RCPGs peuvent aussi s’associer entre eux pour former des oligomères de récepteurs. Dans cette thèse, nous nous sommes penchés sur les interactions entre les RCPGs et les RAMPs, et plus particulièrement sur l’interrelation entre ce type d’association RCPG/RAMP et l’assemblage en oligomères de récepteurs, en utilisant le récepteur du CGRP comme modèle d’étude. Une première étude nous a tout d’abord permis de confirmer l’interaction entre le récepteur CLR et RAMP1, dans un contexte de cellules vivantes. Nous avons démontré que ce complexe CLR/RAMP1 active la protéine G et recrute la protéine de signalisation -arrestine suite à une stimulation par le CGRP. Ensuite, nous avons déterminé que même s’il doit obligatoirement former un hétéro-oligomère avec les RAMPs pour être actif, le CLR conserve malgré tout sa capacité à interagir avec d’autres RCPGs. En plus d’observer la présence d’homo-oligomère de CLR, nous avons constaté que tout comme les RCPGs, les RAMPs peuvent eux-aussi s’associer entre eux pour former des complexes oligomériques pouvant comprendre différents sous-types (RAMP1/RAMP2 et RAMP1/RAMP3). Cette observation de la présence d’homo-oligomères de CLR et de RAMP1, nous a amené à nous questionner sur la stœchiométrie d’interaction du complexe CLR/RAMP1. Dans une deuxième étude ayant pour but d’établir la composition moléculaire du récepteur CGRP1 in vivo, nous avons développé une nouvelle approche permettant l’étude de l’interaction entre trois protéines dans un contexte de cellules vivantes. Cette technique baptisée BRET/BiFC, est basée sur le transfert d’énergie de résonance de bioluminescence entre un donneur luminescent, la Renilla luciférase, et un accepteur fluorescent, la protéine fluorescente jaune (YFP), reconstituée suite au ré-assemblage de ces deux fragments. En utilisant cette approche, nous avons pu déterminer que le récepteur CGRP1 est constitué d’un homo-oligomère de CLR interagissant avec un monomère de RAMP1. En démontrant un assemblage oligomérique asymétrique pour le récepteur CGRP1 à partir d’une nouvelle approche biophysique, nous croyons que les travaux présentés dans cette thèse ont contribué à élargir nos connaissances sur le fonctionnement de la grande famille des RCPGs, et seront utile à la poursuite des recherches sur les complexes protéiques impliqués dans la signalisation.
Resumo:
Les agents anti-infectieux sont utilisés pour traiter ou prévenir les infections chez les humains, les animaux, les insectes et les plantes. L’apparition de traces de ces substances dans les eaux usées, les eaux naturelles et même l’eau potable dans plusieurs pays du monde soulève l’inquiétude de la communauté scientifique surtout à cause de leur activité biologique. Le but de ces travaux de recherche a été d’étudier la présence d’anti-infectieux dans les eaux environnementales contaminées (c.-à-d. eaux usées, eaux naturelles et eau potable) ainsi que de développer de nouvelles méthodes analytiques capables de quantifier et confirmer leur présence dans ces matrices. Une méta-analyse sur l’occurrence des anti-infectieux dans les eaux environnementales contaminées a démontré qu’au moins 68 composés et 10 de leurs produits de transformation ont été quantifiés à ce jour. Les concentrations environnementales varient entre 0.1 ng/L et 1 mg/L, selon le composé, la matrice et la source de contamination. D’après cette étude, les effets nuisibles des anti-infectieux sur le biote aquatique sont possibles et ces substances peuvent aussi avoir un effet indirect sur la santé humaine à cause de sa possible contribution à la dissémination de la résistance aux anti-infecteiux chez les bactéries. Les premiers tests préliminaires de développement d’une méthode de détermination des anti-infectieux dans les eaux usées ont montré les difficultés à surmonter lors de l’extraction sur phase solide (SPE) ainsi que l’importance de la sélectivité du détecteur. On a décrit une nouvelle méthode de quantification des anti-infectieux utilisant la SPE en tandem dans le mode manuel et la chromatographie liquide couplée à la spectrométrie de masse en tandem (LC-MS/MS). Les six anti-infectieux ciblés (sulfaméthoxazole, triméthoprime, ciprofloxacin, levofloxacin, clarithromycin et azithromycin) ont été quantifiés à des concentrations entre 39 et 276 ng/L dans les échantillons d’affluent et d’effluent provenant d’une station d’épuration appliquant un traitement primaire et physico- chimique. Les concentrations retrouvées dans les effluents indiquent que la masse moyenne totale de ces substances, déversées hebdomadairement dans le fleuve St. Laurent, était de ~ 2 kg. En vue de réduire le temps total d’analyse et simplifier les manipulations, on a travaillé sur une nouvelle méthode de SPE couplée-LC-MS/MS. Cette méthode a utilisé une technique de permutation de colonnes pour préconcentrer 1.00 mL d’échantillon dans une colonne de SPE couplée. La performance analytique de la méthode a permis la quantification des six anti-infectieux dans les eaux usées municipales et les limites de détection étaient du même ordre de grandeur (13-60 ng/L) que les méthodes basées sur la SPE manuelle. Ensuite, l’application des colonnes de SPE couplée de chromatographie à débit turbulent pour la préconcentration de six anti-infectieux dans les eaux usées a été explorée pour diminuer les effets de matrice. Les résultats obtenus ont indiqué que ces colonnes sont une solution de réchange intéressante aux colonnes de SPE couplée traditionnelles. Finalement, en vue de permettre l’analyse des anti-infectieux dans les eaux de surface et l’eau potable, une méthode SPE couplée-LC-MS/MS utilisant des injections de grand volume (10 mL) a été développée. Le volume de fuite de plusieurs colonnes de SPE couplée a été estimé et la colonne ayant la meilleure rétention a été choisie. Les limites de détection et de confirmation de la méthode ont été entre 1 à 6 ng/L. L’analyse des échantillons réels a démontré que la concentration des trois anti-infectieux ciblés (sulfaméthoxazole, triméthoprime et clarithromycine) était au dessous de la limite de détection de la méthode. La mesure des masses exactes par spectrométrie de masse à temps d’envol et les spectres des ions produits utilisant une pente d’énergie de collision inverse dans un spectromètre de masse à triple quadripôle ont été explorés comme des méthodes de confirmation possibles.