1000 resultados para protocolo OPRA
Resumo:
[Exposition. Paris, Opéra national de Paris. 1938]
Resumo:
Calendrier des spectacles et des répétitions. - À partir du 28 octobre, jour de l'incendie de l'Opéra, rue Le Peletier, jusqu'au 31 décembre, le livre de régie mentionne les représentations de l'Opéra-Comique, du Théâtre-Italien, et d'autres théâtres de Paris. En date du 28 octobre, état général du personnel de l'Opéra, récit de l'incendie. - Contient 3 pièces additionnelles
Resumo:
Calendrier des spectacles et des répétitions. - Ne comporte plus la liste du personnel de la régie. Mentionne également les répétitions et les premières de l'Opéra-Comique et du Théâtre-Italien. - Contient 20 pièces additionnelles
Resumo:
Explantes de bananeira cv. Caipiras (AAA) foram cultivados in vitro. Nas subculturas de estabelecimento e multiplicação, o meio utilizado foi MS + 5 mg/l de BAP e, na de enraizamento, 50%MS sem BAP. Na avaliação das subculturas, a maior contaminação ocorreu no estabelecimento (74,7%), seguindo decrescente até o enraizamento, com 5,6%. O número de brotos por frasco diminui ao longo das subculturas, atingindo 3,7 brotos na subculturas 1 e 1,7 na subcultura 4. O tamanho dos brotos permaneceu entre 24 e 26 mm, nas subculturas de 1 a 3, diminuindo na subcultura 4, com 22 mm. Como conseqüência, a classe de brotos menores (x £ 20 mm) predominou, variando de 56% na subcultura 1 para 65% na subcultura 4. No enraizamento, a predominância (62%) foi de brotos na faixa entre 30 e 60 mm, com média de 4,6 brotos por frasco. A avaliação geral do processo indicou um rendimento real de 70,9 mudas/rizoma.
Resumo:
O trabalho teve como objetivo avaliar um sistema de micropropagação para a cultivar Prata-Anã, observando-se os principais fatores de eficiência e limitação no processo produtivo da muda. Os explantes foram estabelecidos em meio nutritivo MS, suplementado com 5mg/L de BAP (benzilaminopurina) e 30g/L de sacarose solidificado com 8g/L de ágar e pH ajustado em 5,7. A fase de multiplicação foi composta pelo mesmo meio de cultura e a de enraizamento constituída pela metade da concentração dos sais de MS e de sacarose, sem regulador de crescimento. Perdas por contaminação bacteriana foram maiores durante o estabelecimento in vitro e por fungos, nos dois últimos subcultivos. As maiores taxas de multiplicação ocorreram entre o 4º e o 5º subcultivos e, ao final do processo, observou-se maior proporção de brotos na classe entre 30 e 60mm. Com relação à eficiência da utilização da mão-de-obra no laboratório, observou-se que o processamento diário de frascos por operador foi baixo nas fases de estabelecimento, primeiro subcultivo e enraizamento, quando comparado com as fases de multiplicação exponencial dos explantes. Apesar de não terem sido constatadas perdas na fase de aclimatação, foi observada a ocorrência de 1% do total das plântulas com anomalias morfológicas.
Resumo:
Référence bibliographique : Rol, 59060
Resumo:
En este trabajo se presenta un protocolo para la zonificación intraparcelaria de la viña con la finalidad de vendimia selectiva. Se basa en la adquisición de una imagen multiespectral detallada en el momento del envero, a partir de la cual se obtiene el índice de vegetación de la diferencia normalizada (NDVI). Este índice se clasifica en áreas de vigor alto y bajo mediante un proceso de clasificación no supervisada (algoritmo ISODATA). Las zonas resultantes se generalizan y se transfieren al monitor de cosecha de una máquina vendimiadora para realizar la recolección selectiva. La uva recolectada según este protocolo en parcelas control ha mostrado diferenciación en cuanto a parámetros de calidad como el pH, la acidez total, el contenido de polifenoles y el color. La imagen multiespectral utilizada fue adquirida por el satélite Quickbird-2. Los datos de calidad de la uva fueron muestreados según una malla regular de 5 filas por 10 cepas, procediendo a un test estadístico de rangos múltiples para analizar la separación de medias de las variables analizadas en cada zona de NDVI.
Resumo:
Este proyecto desarrolla una aplicación sobre la placa LPC1769 para soportar las funcionalidades más comunes del protocolo Modbus RTU.
Resumo:
ABSTRACT Proposal for an evaluation protocol of the ecological quality of Andean rivers (CERA) and its use in two basins in Ecuador and Peru A Rapid Protocol is presented for Evaluation of the Ecological Status of Andean Rivers (CERA) localized over 2000 m.a.s.l. from the Northern Andes (Venezuela) through the Altiplano in the Central Andes (Bolivia). This protocol was used in 45 sampling sites in the Guayllabamba River Basin in Ecuador and in 42 sampling sites in the Ca nete River Basin in Peru. Previously, and in order to test if the sampling stations may or not be considered reference stations, we constructed a method that assesses 24 basin attributes, hydrology, reach and riverbed and that uctuates from 24 to 120 points; sites with values higher than 100 were considered as potential reference sites. Besides the benthic macroinvertebrats" evaluation, the river habitat and riparian vegetation were also evaluated through of the application of the indices ABI (R´ os et al., submitted), IHF (Pardo et al., 2002) and QBR-And, respectively. The convenience of the initial allocation of the reference sites was evaluated as well. These indices have been properly adapted to the conditions and characteristics of the high Andes rivers. The results obtained for both basins were compared and discussed. Through the use of the CERA protocol, the particular perturbation gradients and the natural variability of the reference sites in both countries were recognized. RESUMEN Propuesta de un protocolo de evaluación de la calidad ecológica de ríos andinos (CERA) y su aplicaci´on a dos cuencas en Ecuador y Perú Se presenta un protocolo rápido de evaluación de la Calidad Ecológica de Ríos Andinos (CERA), situados sobre los 2000 m.s.n.m, desde los Andes del Norte (Venezuela) hasta el Altiplano de los Andes Centrales (Bolivia). Este protocolo ha sido aplicado en 45 estaciones de muestreo en la cuenca del río Guayllabamba en Ecuador y en 42 estaciones de muestreo en la cuenca del río Cañete en Perú. Previamente, para probar si las estaciones de muestreo pueden o no ser estaciones de referencia construimos un método que valora 24 atributos de cuenca, hidrología, tramo y lecho y que fluctúa de 24 a 120 puntos; valores superiores a 100 fueron considerados como sitios potencialmente de referencia. Además del estudio de los macroinvertebrados bentónicos, se evaluó el hábitat fluvial y la comunidad vegetal de ribera a través de la aplicación de los índices ABI (Ríos et al., sometido), IHF (Pardo et al., 2002) y QBR-And respectivamente; así como la conveniencia de la asignación inicial de las estaciones de referencia. Estos índices han sido adecuadamente adaptados a las condiciones y características propias de los ríos altoandinos. Los resultados obtenidos fueron comparados y discutidos entre ambas cuencas. Mediante la aplicación del protocolo CERA se han reconocido los respectivos gradientes de perturbación y la variabilidad natural de las estaciones de referencia en ambos países.
Resumo:
OBJETIVO: Este trabalho tem como objetivo criar um protocolo de testes de aceitação para equipamentos de imagem por ressonância magnética e demonstrar como e quais tipos de dispositivos de teste podem ser usados para a coleta de dados. MATERIAIS E MÉTODOS: Para cada um dos 15 testes selecionados foram elaborados a definição, o procedimento, a forma de análise e o critério de aceitação. RESULTADOS: Através dos testes de aceitação descritos é possível verificar características técnicas que constam nas propostas de venda dos fabricantes, assim como estabelecer valores de referências para serem utilizados em posteriores testes de constância. CONCLUSÃO: Futuros programas de garantia da qualidade em imagem por ressonância magnética devem considerar testes semelhantes ou iguais aos descritos neste trabalho.
Resumo:
OBJETIVO: A fim de simplificar a utilização das tabelas correspondentes aos fatores de qualidade no TRS-398 da International Atomic Energy Agency na calibração cruzada da câmara de placas paralelas por comparação com uma câmara cilíndrica calibrada em um feixe de elétrons de qualidade Qcross, é introduzida uma energia intermediária e arbitrária Qint na qual a câmara de placas paralelas deverá ser calibrada. O objetivo deste trabalho consiste em avaliar a escolha desta energia intermediária. MATERIAIS E MÉTODOS: Uma câmara de placas paralelas da Scanditronix, modelo NACP-02, e uma câmara PTW Markus foram calibradas em dois aceleradores lineares da Varian, Clinac 2100C e Clinac 23EX, nas energias de 16 e 20 MeV, respectivamente. Como câmara de referência foi utilizada uma câmara da Nuclear Enterprises, modelo 2571, previamente calibrada em termos de Dw no Instituto de Pesquisas Energéticas e Nucleares, para um feixe de 60Co. RESULTADOS: Os fatores de calibração N D,w assim obtidos apresentam uma variação de 0,07%, o que pode ser considerado desprezível. Os valores de dose absorvida na água determinados no Clinac 2100C para uma Qint de 16 MeV apresentam uma variação de 0,04% para a menor energia (4 MeV) e de 2,6% para a maior energia (16 MeV), em relação ao protocolo TRS-381. Já para uma Qint de 20 MeV, as variações observadas são de 1,3% e 3,5%. Por outro lado, as doses determinadas no Clinac 23EX para as Qint de 16 MeV e de 20 MeV são de 1,9% e 2,0% e de 2,8% e 3,0%, respectivamente. CONCLUSÃO: A escolha de Qint não é tão crítica assim, principalmente quando não de dispõem de feixes de elétrons que tenham na prática um valor de R50 exatamente igual a 7,5 g.cm-2.